Molecular depth profiling with reactive ions, or why chemistry matters in sputtering.

Similar documents
Surface and Interface Analysis. Investigations of Molecular Depth Profiling with Dual Beam Sputtering. Journal: Surface and Interface Analysis

Secondaryionmassspectrometry

Secondary Ion Mass Spectrometry (SIMS) Thomas Sky

Secondary Ion Mass Spectrometry (SIMS)

Surface and Interface Characterization of Polymer Films

RESEARCH ARTICLE. Hybrid Organic/Inorganic Materials Depth Profiling Using Low Energy Cesium Ions

Secondary ion mass spectrometry (SIMS)

( 1+ A) 2 cos2 θ Incident Ion Techniques for Surface Composition Analysis Ion Scattering Spectroscopy (ISS)

Characterization of Ultra-Shallow Implants Using Low-Energy Secondary Ion Mass Spectrometry: Surface Roughening under Cesium Bombardment

Secondary-Ion Mass Spectrometry

PHI Model 06-C60 Sputter Ion Gun

Molecular Depth Profiling with Cluster Ion Beams

ToF-SIMS or XPS? Xinqi Chen Keck-II

Etching Issues - Anisotropy. Dry Etching. Dry Etching Overview. Etching Issues - Selectivity

SIMS: Secondary Ion Mass Spectrometry

A noble gas electronic configuration is highly desirable energetically

Interfacial Chemistry and Adhesion Phenomena: How to Analyse and How to Optimise

Enhancing Secondary Ion Yields in Time of Flight-Secondary Ion Mass Spectrometry Using Water Cluster Primary Beams

IONTOF. Latest Developments in 2D and 3D TOF-SIMS Analysis. Surface Analysis Innovations and Solutions for Industry 2017 Coventry

Effect of Spiral Microwave Antenna Configuration on the Production of Nano-crystalline Film by Chemical Sputtering in ECR Plasma

Secondary ion mass spectrometry (SIMS)

Lecture 11 Surface Characterization of Biomaterials in Vacuum

Comparisons of DFT-MD, TB- MD and classical MD calculations of radiation damage and plasmawallinteractions

Ion Beam Induced Luminescence (IBIL) for scintillator analysis

High-Precision Evaluation of Ultra-Shallow Impurity Profiles by Secondary Ion Mass Spectrometry

A mixed cluster ion beam to enhance the ionization efficiency in molecular secondary ion mass spectrometry

Secondary Ion Mass Spectroscopy (SIMS)

Lecture 22 Ion Beam Techniques

Computer-Simulation Studies of Plasma- Surface Interactions

In-situ Ar Plasma Cleaning of Samples Prior to Surface Analysis

A DIVISION OF ULVAC-PHI. Time-of-Flight Secondary Ion Mass Spectrometer with Parallel Imaging MS/MS for Confident Molecular Identification

Nova 600 NanoLab Dual beam Focused Ion Beam IITKanpur

Survey of Elements. 1s - very small atom All noble gases have very high first I.E. s which is in line with their chemical inertness

Introduction to SIMS Basic principles Components Techniques Drawbacks Figures of Merit Variations Resources

Molecular sputter depth profiling using carbon cluster beams

Sputtering by Particle Bombardment

In the last two decades, static SIMS has become one

CLUSTER SIZE DEPENDENCE OF SPUTTERING YIELD BY CLUSTER ION BEAM IRRADIATION

SURFACE PROCESSING WITH HIGH-ENERGY GAS CLUSTER ION BEAMS

Secondary Ion Mass Spectrometry (SIMS) for Surface Analysis

TMT4320 Nanomaterials November 10 th, Thin films by physical/chemical methods (From chapter 24 and 25)

Secondary Ion Mass Spectrometry (SIMS) for Surface Analysis

Surface Chemistry and Reaction Dynamics of Electron Beam Induced Deposition Processes

Control of Optical Properties by the Stepwise Chemical and Plasma Spray Treatment of Polycarbonate

Chapter 3. Stoichiometry: Calculations with Chemical Formulas and Equations

Chemical Reactions Induced by Ionizing and Electron-beam Irradiation in Freon/Water (Ice) Films

Secondary Ion Mass Spectrometry

Secondary Ion-Mass Spectroscopy (SIMS)

Development of a Standards Base for Static SIMS

PHI 5000 Versaprobe-II Focus X-ray Photo-electron Spectroscopy

Multiscale modelling of D trapping in W

Radioresistance of adenine to cosmic rays

L.7. Mass Spectrum Interpretation

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Re: Understanding Heterogeneity in Genesis Diamond like Carbon Film Using SIMS Analysis of Implants (Jurewicz et. al)

1) In what pressure range are mass spectrometers normally operated?

Secondary Ion Mass Spectrometry (SIMS)

Secondary ion emission from kev energy atomic and polyatomic projectile impacts on sodium iodate

Various approximations for describing electrons in metals, starting with the simplest: E=0 jellium model = particle in a box

Analysis of Poly(dimethylsiloxane) on Solid Surfaces Using Silver Deposition/TOF-SIMS

Progress Report on Chamber Dynamics and Clearing

3 Stoichiometry: Calculations with Chemical Formulas and Equations

Simulation of the cathode surface damages in a HOPFED during ion bombardment

In Situ Observation of Damage Evolution in Polycarbonate under Ion Irradiation with Positrons

Ionizing radiation produces tracks defined by the geometry of the energy deposition events. An incident ion loses energy by Coulombic interactions

Sputtering of Glass Dust Grain by Ions and Electrons

Mass Spectrometry. General Principles

Advanced Materials Characterization Workshop June 3 and 4, 2013

X-Ray Photoelectron Spectroscopy (XPS) Prof. Paul K. Chu

I. 16. Coloration of Polyethylene Terephthalate (PET) Film by 3MeV Proton Beams

Applications of Micro-Area Analysis Used by JPS-9200 X-ray Photoelectron Spectrometer

TECHNIC A L WORK ING GROUP ITWG GUIDELINE ON SECONDARY ION MASS SPECTROMETRY (SIMS)

S1. X-ray photoelectron spectroscopy (XPS) survey spectrum of

Atomic structure, Periodic Table Language of Chemistry

The Basics of General, Organic, and Biological Chemistry

Applications of ion beams in materials science

RESEARCH ARTICLE. Dynamic Reactive Ionization with Cluster Secondary Ion Mass Spectrometry

Structural Determination Of Compounds

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n

Chemical Bonds, Lewis Structures, Bond Order, and Formal Charge

Plasma-Surface Interactions and Impact on Electron Energy Distribution Function

SIMS XVIII SIMS Course Depth Profiling

Lecture Interp-3: The Molecular Ion (McLafferty & Turecek 1993, Chapter 3)

Methods of surface analysis

Application of Surface Analysis for Root Cause Failure Analysis

Chapter 4. Surface defects created by kev Xe ion irradiation on Ge

ABNORMAL X-RAY EMISSION FROM INSULATORS BOMBARDED WITH LOW ENERGY IONS

ATOMS, MOLECULES and IONS

UNIT 3. By: Ajay Kumar Gautam Asst. Prof. Dev Bhoomi Institute of Technology & Engineering, Dehradun

Depth Profiling of Peptide Films with TOF-SIMS and ac 60 Probe

An ion source performs the following two functions:

EROSION AND DEPOSITION MECHANISMS IN FUSION PLASMAS. A. Kirschner

Radiation Processing. Chemical Effects

NUCLEAR MAGNETIC RESONANCE AND INTRODUCTION TO MASS SPECTROMETRY

Supplementary Figure 1: AFM topography of the graphene/sio 2 [(a) and (c)] and graphene/h BN [(b) and (d)] surfaces acquired before [(a) and (b)],

POINT SOURCES OF POLLUTION: LOCAL EFFECTS AND IT S CONTROL Vol. II - Contaminant Fate and Transport Process - Xi Yang and Gang Yu

Polymer Chemistry Prof. Dibakar Dhara Department of Chemistry Indian Institute of Technology, Kharagpur

PHI nanotof II TOF-SIMS. 1

Understanding electron energy loss mechanisms in EUV resists using EELS and first-principles calculations

sample was a solution that was evaporated in the spectrometer (such as with ESI-MS) ions such as H +, Na +, K +, or NH 4

Transcription:

Molecular depth profiling with reactive ions, or why chemistry matters in sputtering. L. Houssiau, N. Mine, N. Wehbe Research Centre in Physics of Matter and Radiation (PMR), University of Namur (FUNDP), Rue de Bruxelles 61, B5000 Namur, Belgium Important notice: this document is not in a proceeding format yet. It only shows some figures with short comments. It should be used as an extended abstract, only intended for conference attendees, in order to prepare for the discussion day. Abstract Depth profiling of organics has long been considered as a dream impossible to reach, owing to fast molecular degradation upon ion irradiation. The advent of polyatomic ion sources has dramatically defeated this assumption and spectacular advances in the field have occurred over the last five years. More recently, we have shown that low energy reactive ions, like Cs + or O 2 +, can also be used quite successfully for organic depth profiling. In this paper, we will review the recent knowledge on cesium and, to a lesser extent, oxygen depth profiling of organics. We will show that most polymers, but also smaller organic molecules, like amino acids, sugars or vitamins, are amenable to molecular depth profiling with reactive ions. We will discuss how the ion energy, the enhanced ionization and the high chemical activity of the ions work together to preserve the molecular integrity of the analyzed species. In contrast with cluster depth profiling, in which the mechanistic aspects of the cluster surface interaction are dominant, leading to very high sputtering yields, we show how chemical effects dominate in reactive ion sputtering. Two mechanically identical ions such as cesium and xenon, at identical experimental conditions, lead to extremely different results: stable molecular signals with cesium, but an immediate degradation with xenon. Only the ion chemistry changes, proving that cesium reactivity plays a major role in organic depth profiling, most likely by preventing crosslinking reactions. Quite surprisingly, we also show that low energy (below 1 kev) Xe + ions can be used to perform molecular depth profiling on some organic compounds with high yields and very limited damages. Short introduction We will discuss in the paper the major role played by the sputtering ion s chemistry on molecular depth profiling. Two types of organic materials will be considered: polymers and (nonpolymerized) organic compounds. First we will recall some recent data obtained with low energy Cs + ions on polymers. We will then concentrate on sputtering yields measurements on three polymers (PMMA, PC and PS) obtained with Xe + and Cs + ions. The role of the energy will also be discussed. From those measurements, a model explaining why Cs is so successful on polymers will be given. In the second part of the paper, we will show our newest data on various organic solids (amino acids, vitamins) obtained with low energy Cs +, Xe + and O + 2 ions. We will finally summarize those observations, comparing the pros and cons of different projectiles.

Experimental TOF SIMS IV (IONTOF) in a dual beam mode: analysis: Ga +, 15 kev, 1 pa sputtering: Cs +, Xe +, O 2 +, 1500 ev, 50 na noninterlaced mode to limit the Ga fluence Part I: Polymers Several polymers were successfully depth profiled with low energy Cs + ions: PMMA, PC, PS, PET, PEO, PP, PE, PPS This paper will focus on PMMA, PC and PS. It is know that PMMA is a polymer of the degrading type, meaning that it fragments upon irradiation, whereas PC and PS are of the crosslinking type, meaning that they crosslink upon irradiation. 00 0 93 117 Cs 133 SiO 2 Fig.1. 200 ev Cs + on polycarbonate (50 nm/si), negative depth profile. Specific molecular fragments (m/z 93, 117, 133) are measured throughout the depth profile. In the initial transient, the molecular signals decrease first rapidly then recover when the implanted Cs subsurface layer is reached. 200 0 200 400 600 800 0 1200 1400 1600 1800 Time (s) 0 Cs C 8 H 5 H 5 C 9 C 7 0 0 2000 3000 4000 Sputtering time (s) Fig. 2. 200 ev Cs + on polystyrene (50 nm/si), negative depth profile. Many hydrocarbon fragments were measured in the negative mode, such as C 8 H 5 (likely H 5 C C ) indicating that the polymer keeps its molecular integrity upon Cs irradiation. Other evidences come from XPS measurements in the steady state, showing that the aromatic shakeup peak remains. Similar depth profiles will be shown at the conference on PET and PMMA. When 200 ev Xe + ions are used on PC and PS, no molecular depth profiling is possible since molecular signals disappear after a few seconds of sputtering. However, some molecular information persists on PMMA. This is not really surprising as PMMA fragments easily upon irradiation. In order to understand the role of the projectile s chemistry on sputtering, sputtering yields were measured on PS, PC and PMMA with 250 ev Xe + and Cs + ions. The data are summarized in table 1:

Sputter Ion Sputtering yield (atoms/ion) PS PC PMMA 250 ev Xe + 0.61 0.63 17 250 ev Cs + 4.9 3.4 23 Table 1: Sputtering yields obtained with Xe + and Cs + ions on PS, PC and PMMA The sputtering yield on PS and PC (crosslinking type) are much higher with Cs than with Xe. The sputtering yield on PMMA (degrading type) is much higher than on PS and PC with both projectiles. On PS and PC, Xe ions rapidly produce crosslinking reactions, degrading the polymer into a graphitized structure, with a very low sputtering yield. When a reactive ion like Cs is used, the implanted Cs atoms react with the free radicals created in the polymer, which prevents the crosslinking (Please note: this will be discussed in detail at the conference). The sputtering yields were also measured at six different energies: the data are summarized in figure 3: Sputtering yields (at./primary ion) 1 PMMA (Cs) PC (Cs) PS (Cs) PS (Xe) Fig. 3. sputtering yields on PC, PS and PMMA with 1500 ev Cs + ions. The Xe + sputtering yields on PS are also shown. Sputtering yields increase rapidly up to 500 ev then start to saturate. Crosslinking polymers (PS, PC) behave in a similar way, whereas sputtering yields on PMMA are always much higher, due to the easy fragmentation of such polymer. 0 200 400 600 800 0 Cesium primary ions energy (ev) Sputtering Yields (at./primary ion) 17 16 15 14 13 12 11 9 8 7 6 5 4 3 2 1 Xe / O 2 PS Xe PS 0 200 300 400 500 600 700 800 900 0 1 Cesium ions energy (ev) Fig. 4. Sputtering yields on PS obtained with Xe + and Xe + with O 2 flooding. The sputtering yields are remarkably increased just by the presence of O 2 molecules at the surface. The oxygen plays a role similar to Cs, reacting with the free radicals and inhibiting crosslinking. In this case however, the aromaticity of the polymer seems to be destroyed.

As a first conclusion, Cs + ions allow true molecular depth profiling on polymers owing to three factors: 1. The low energy (counts) 00 0 150eV 200eV 250eV 500eV 750eV 0eV 0 20 30 40 50 60 70 depth (nm) Fig. 5. Depth profiles on PC layers obtained with 1500 ev Cs + ions. The best profiles are obtained at low energy and severe polymer damages are measured at 1 kev. The steady state signals decrease with the energy and the transient becomes longer with the energy. The latter effect is due to the implantation depth of Cs, which increases with the energy. 2. The ionization enhancement Cs is the most electropositive element (0.79 Pauling electronegativity) and a very strong reducer (redox potential 3.026 V). Polymer fragments are easily ionized in the presence of implanted Cs through electron transfer from the Cs (reduction): M + Cs M + Cs + 3. Chemical effects Crosslinking reactions in polymers constitute a major limitation for depth profiling with ions. The extreme reactivity of Cs hinders the crosslinking reactions and help fragmenting the polymer. Xe + ions have similar masses but are inert: in this case, the polymer turns immediately into a heavily crosslinked, irreversibly damaged, material. Part II: Organic compounds Cs, Xe and O 2 depth profiles were obtained on various amino acids, sugars and vitamines. Only data on arginine and ascorbic acid are briefly reviewed in this extended abstract. a) arginine (~ nm layers): Depth profiles were obtained with Cs + and Xe + at different energies. The molecular ion (M1) can be followed with 250 ev Cs + throughout the depth profile (Fig. 6.), but no steady state is reached and the signal drops beyond a critical Cs dose. Large molecular fragments (m/z 58 and 116) remain, with relatively constant intensities. With 200 ev Xe + (Fig. 7.), a steady state

was surprisingly obtained, proving that molecular depth profiling is indeed possible with low energy Xe, with limited molecular damage. 00 Xe Depth Profile Arginine 0 M1 116 58 Si 00 0 200 ev Si + CH 5 N + 3 C 3 H 9 N + 3 C 5 H N + 3 C 5 H 11 N + 4 H 15 N 4 O + 2 positive ions 0,0 2,0x 16 Cs fluence (ions/cm 2 ) 1 0 1x 16 2x 16 3x 16 4x 16 5x 16 Xe fluence Fig. 6. 250 ev Cs + on arginine Fig. 7. 200 ev Xe + on arginine b) ascorbic acid H 8 0 6 (~70 nm layers) On this compound, the molecular depth profiling with 200 ev Cs was unsuccessful, with all molecular signals dropping rapidly (Fig. 8.). On the other hand, an excellent depth profile was obtained with 200 ev Xe (not shown) and was even improved with O 2 flooding (Fig. 9.). This result again confirms that low energy Xe + can be used to depth profile organic compounds. Similar results were obtained on other amino acids and sugars. 00 0 Si SiO 2 Cs O 6 C 4 H 3 O 4 H 6 O 6 O 5 C 5 H 3 O 5 Fig. 8. 200 ev Cs + depth profile on ascorbic acid: molecular signals are rapidly lost and no steady state can be reached. The molecule is destroyed by the impinging Cs + ions. 0,0 4,0x 16 8,0x 16 Cs fluence (ions/cm 2 ) 00 0 [M1] SiO 2 Fig. 9. 200 ev Xe + (plus O 2 flooding) depth profile on ascorbic acid: a high steady state value is measured on the molecular ion (M1), proving that the molecule is only weakly damaged by low energy Xe + ions. 0 1x 16 2x 16 Xe fluence (ions/cm 2 )

The results measured with Xe + will be discussed at the conference with damage accumulation and erosion models. Our measurements on different organic compounds generally indicate that a steady state is obtained with low energy Xe + ions but not always with Cs + ions. It appears that the compounds are more fragmented with Cs, which could again be explained by the high Cs reactivity. In addition to ion bombardment damages, implanted Cs atoms react directly with the molecules, what triggers fragmentation and sometimes destruction of the molecules. Conclusions As a short general conclusion, it turns out that the reactivity of implanted Cs atoms plays a dominant role in organic depth profiling. In the case of polymers, this reactivity is strongly beneficial as it promotes negative ionization and inhibits crosslinking reactions. In the case of organic compounds, while molecular depth profiling is still possible in most cases, the Cs reactivity induces fragmentation of the molecules. The molecular ion is often lost throughout the depth profile, but large fragments are still present in the profile. Surprisingly, Xe + ions can be used at low energy (<1 kev) to obtain molecular depth profiles on organic compounds. The following table attempts to summarize the use of different projectiles on different classes of organic materials. This is of course extremely simplified and could be a starting point for further discussions at the conference. Cs + Xe + + O 2 Cluster beams PS, PC, PET ++ ( crosslinking type) PMMA ++ + + +(+) ( degrading type) Organic compounds + / +(+) + ++ Table 2: a comparison between different projectiles. : no molecular depth profiling + : molecular depth profiling possible ++ : recommended for molecular depth profiling Bibliography A complete bibliography will be given in the proceedings paper. Part of this work is or will be published in the following references: 1. Mine N, Douhard B, Brison J, Houssiau L, Rapid Commun. Mass Spectrom. 2007; 21: 2680. 2. Houssiau L, Douhard B, Mine N, Appl. Surf. Sci. 2008 ; 255 : 970 3. Mine N, Douhard B, Houssiau L, Appl. Surf. Sci. 2008 ; 255 : 973 4. L. Houssiau, N. Mine, Surface Interface Analysis, accepted with minor revisions