17591_Brochure.qxd 11/1/06 10:46 AM Page 2 The cobas e 411 analyzer offers... Accurate Results ECL technology delivers excellent low-end sensitivity and broad dynamic ranges Quality Results Assay-specific QC confidence intervals to determine calibration Improved tracking capabilities for QC patient samples and calibrator materials Disposable tips and cups reduce the potential for carryover Standardization Uniform reagent carriers, applications, analytical technologies, and software interface with cobas analyzers Control Improve your labs financial performance, enhance efficiency, and make a difference for the doctors and patients who rely on the critical information to make vital decisions about healthcare, every day. cobas e 411 analyzer Confidence in every result.
cobas e 411 analyzer operator interface Reduced complexity Results in real time Programmable for customization 5-position sample rack Universal, color-coded with other Roche syste Accommodates multip without adapters Provides efficient rout of samples Control Unit Microsoft Windows XP based user-interface Color LCD touch-screen Pentium processor cobas e 411 Analyzer ECL technology Throughput: up to 86 tests per hour 18 channels (reagent slots), temperature controlled at 20 C Clot detection (pressure sensor) and liquid level detection (capacitance) Disposable AssayTip for carry-over free sample pipetting Disposable AssayCup utilized as reaction vessel Automatic sample dilution upon operator request 100 / 200 test packs
compatible s le tube sizes ng sample process Disposable assay tips Clot detection Liquid level detection e pack reagents 100-200 tests per e pack Ready-to-use; 60-day mean onboard stability Unique package design reduces inventory, eliminates reagent preparation and minimizes calibration time 2-D barcodes eliminate the need for manual entry of application and reagent data reagent compartment 18 reagent channels Temperature controlled Random reagent placement Automatic reagent registration Automatic bottle changeover Automatic calibration notification Up to 8 weeks stability
ECL extended measuring range Chemiluminescence measuring range Roche ECL measuring range Roche Diagnostics Electrochemiluminescence (ECL) Chemiluminescence (CL) ECL technology for accurate results the first time Electrochemiluminescence (ECL), a sophisticated technology used in Roche immunoassays, delivers excellent low-end sensitivity and broad dynamic ranges. The measuring cell uses an amplified signal to detect ultra-low concentrations of analyte. By precisely controlling electrically-initiated reactions, ECL technology virtually eliminates unnecessary repeats and reruns, providing accurate results the first time. cobas e 411 analyzer user interface The user interface provides specimen control and data management from an easy-to-navigate, Microsoft Widows XP based LCD touch-screen. STAT turnaround time Results in 9 minutes for critical tests such as Troponin T, CK-MB, Myoglobin, and HCG 33% faster than other systems. Unique no-prep reagent concept delivers greater convenience The cobas e packs are ready-to-use, eliminating hands-on time, and are common to other Roche systems, reducing storage and inventory requirements. Closed for protection against environmental elements, the cobas e packs have self-sealing lids that increase onboard stability.
17591_Brochure.qxd 11/1/06 10:46 AM Page 2 The cobas e 411 analyzer offers... Accurate Results ECL technology delivers excellent low-end sensitivity and broad dynamic ranges Quality Results Assay-specific QC confidence intervals to determine calibration Improved tracking capabilities for QC patient samples and calibrator materials Disposable tips and cups reduce the potential for carryover Standardization Uniform reagent carriers, applications, analytical technologies, and software interface with cobas analyzers Control Improve your labs financial performance, enhance efficiency, and make a difference for the doctors and patients who rely on the critical information to make vital decisions about healthcare, every day. cobas e 411 analyzer Confidence in every result.
cobas e 411 analyzer Technical Specifications System System Components Sample Throughput Test Throughput (theoretical max) Number of Channels Programmable Parameters Sample Material Fully automated, multi-channel immunoassay analyzer for random access processing of ECL based immuno assays (Elecsys system format) Self contained bench top analyzer comprising an analytical unit and a customized user interface Up to 86 samples per hour 86 results per hour (steady state mode, only 18 min assays) 18 channels (reagent slots) for maximum of 18 different chemistries N/A, programming-by-loading (PBT) concept, application data are transferred without operator intervention from the 2D barcode of the reagent pack (RP) into the instrument database Serum/plasma, urine, others Sample Input/Output Disk: 30 positions for samples, calibrators and controls Rack: 15 racks with 5 samples each (= 75 samples in/out) STAT port: STAT samples are processed with priority Sample Volume 10 50 µl Sample Dilution Onboard, user definable, 1 or 2 step, max 1:400 Sample Clot Detection Available (pressure sensor) Sample Barcode Types Code 128 Codabar (NW 7) Interleaved 2 of 5 Code 39 Control Unit Panel PC System Interfaces RS 232 serial interface, bi-directional Sample Data Base 2,000 results (samples and QC) Calibrator/QC Input Elecsys system specific barcoded CalSet vials on disk or racks Calibration Methods Lot calibration (L-cal) Reagent Pack (RP) calibration (R-Cal) QC Methods Individual QC and cumulative QC Up to 100 controls pre-programmable Preventive QC after calibration of the stand-by cobas e packs Rerun/Reflex Function Manual rerun Electrical Requirements Power requirements: 230 Volts AC 110 Volts AC 1,000 kva (disk), 1,250 kva (rack) Frequency: 50 Hz or 60 Hz +/- 0.5 % Water/Waste Water: Bacteria free, deionised water Requirements supply, resistance of < 10 µs/cm Water consumption: Liquid waste: Onboard waste container (4 liter), direct drain optional Regulatory and Safety GS, CE, UL, c-ul, EN/IEC 61010-2-101, Requirements CB certificate Operating Conditions Ambient temperature: 18 to 32º C Ambient humidity: 20 to 80% (RH, without condensation) Heat Output: 2,879 kj/hr (analyzer unit) Noise Output: 60 dba (stand-by), 63 dba (operation avg.) Physical Dimensions Width (disk/rack): 120 cm / 170 cm 47.2 in / 67 in Depth (disk/rack): 73 cm / 95 cm 28.7 in / 37.4 in Height: 80 cm / 31.4 in (closed top cover) 109 cm / 43 in (opened top cover) Weight Disk: 180 kg / 397 lbs Rack: 250 kg / 551 lbs Microsoft is a trademark of Microsoft Corporation. Pentium is a trademark of Intel Corporation. COBAS, COBAS E, ELECSYS and LIFE NEEDS ANSWERS are trademarks of Roche. Roche Diagnostics 9115 Hague Road Indianapolis, IN 46256 http://us.labsystems.roche.com 2006 Roche Diagnostics. All rights reserved. 491_29744_1006