A Discussion on Contact Condition in Simulation of RCFT Columns Alifujiang XIAMUXI 1, a, *, Akenjiang TUOHUTI 1, b, Akira HASEGAWA 2, c

Similar documents
EFFECTS OF CONFINED CONCRETE MODELS ON SIMULATING RC COLUMNS UNDER LOW-CYCLIC LOADING

Modeling of Interfacial Debonding Induced by IC Crack for Concrete Beam-bonded with CFRP

EFFECT OF SHEAR REINFORCEMENT ON FAILURE MODE OF RC BRIDGE PIERS SUBJECTED TO STRONG EARTHQUAKE MOTIONS

FE analysis of steel-concrete composite structure with partial interactions

The Ultimate Load-Carrying Capacity of a Thin-Walled Shuttle Cylinder Structure with Cracks under Eccentric Compressive Force

Moment redistribution of continuous composite I-girders with high strength steel

Durability of Steel Fiber Reinforced Concrete Filled Steel Tubes under Eccentric Loads

AN UNLOADING AND RELOADING STRESS-STRAIN MODEL FOR CONCRETE CONFINED BY TIE REINFORCEMENTS

Lap splice length and details of column longitudinal reinforcement at plastic hinge region

Mesh-sensitivity analysis of seismic damage index for reinforced concrete columns

Nonlinear Analysis of Axially Loaded Concrete-Filled Tube Columns with Confinement Effect

Behavior and calculation on concrete-filled steel CHS (Circular Hollow Section) beam-columns

Estimation of the Residual Stiffness of Fire-Damaged Concrete Members

Seismic Pushover Analysis Using AASHTO Guide Specifications for LRFD Seismic Bridge Design

1. ARRANGEMENT. a. Frame A1-P3. L 1 = 20 m H = 5.23 m L 2 = 20 m H 1 = 8.29 m L 3 = 20 m H 2 = 8.29 m H 3 = 8.39 m. b. Frame P3-P6

Nonlinear numerical simulation of RC frame-shear wall system

Influence of residual stresses in the structural behavior of. tubular columns and arches. Nuno Rocha Cima Gomes

SEISMIC PERFORMANCE EVALUATION METHOD FOR A BUILDING WITH CENTER CORE REINFORCED CONCRETE WALLS AND EXTERIOR STEEL FLAME

Engineering Structures. Nonlinear finite element analysis of CFT-to-bracing connections subjected to axial compressive forces

The Simulation of Dropped Objects on the Offshore Structure Liping SUN 1,a, Gang MA 1,b, Chunyong NIE 2,c, Zihan WANG 1,d

SIMPLIFIED MODELING OF THIN-WALLED TUBES WITH OCTAGONAL CROSS SECTION AXIAL CRUSHING. Authors and Correspondance: Abstract:

Contact analysis - theory and concepts

FE analysis of circular CFT columns considering bond-slip effect: A numerical formulation

Application of Capacity Spectrum Method to timber houses considering shear deformation of horizontal frames

Engineering Science OUTCOME 1 - TUTORIAL 4 COLUMNS

Analysis of a portal steel frame subject to fire by use of a truss model

EARTHQUAKE SIMULATION TESTS OF BRIDGE COLUMN MODELS DAMAGED DURING 1995 KOBE EARTHQUAKE

FLEXURAL RESPONSE OF FIBER RENFORCED PLASTIC DECKS USING HIGHER-ORDER SHEAR DEFORMABLE PLATE THEORY

Determination of Poisson s Ratio of Rock Material by Changing Axial Stress and Unloading Lateral Stress Test

Experimental investigation on monotonic performance of steel curved knee braces for weld-free beam-to-column connections

MSC Nastran N is for NonLinear as in SOL400. Shekhar Kanetkar, PhD

Comparison of Structural Models for Seismic Analysis of Multi-Storey Frame Buildings

Numerical methods of multiaxial fatigue life prediction for elastomers under variable amplitude loadings

OP-023. INTERPRETATION OF INSTRUMENTED TEST PILE RESULT

Extension of the fiber-free approach to complex stress-strain models for concrete

Research of concrete cracking propagation based on information entropy evolution

Análisis Computacional del Comportamiento de Falla de Hormigón Reforzado con Fibras Metálicas

University of Sheffield The development of finite elements for 3D structural analysis in fire

A PROPOSAL OF DESIGN PROCEDURE FOR FLEXURAL STRENGTHENING RC BEAMS WITH FRP SHEET

Particle flow simulation of sand under biaxial test

Shear Behaviour of Fin Plates to Tubular Columns at Ambient and Elevated Temperatures

THERMAL FIELD OF CFST STRUCTURAL COMPONENT UNDER CEMENT HYDRATION

MODELING OF NONLINEAR BEHAVIOR OF RC SHEAR WALLS UNDER COMBINED AXIAL, SHEAR AND FLEXURAL LOADING

Drucker-Prager yield criterion application to study the behavior of CFRP confined concrete under compression

Elastic parameters prediction under dynamic loading based on the. unit cell of composites considering end constraint effect

Nonlinear Analysis of Reinforced Concrete Bridges under Earthquakes

Dynamic and buckling analysis of FRP portal frames using a locking-free finite element

Effect of eccentric moments on seismic ratcheting of single-degree-of-freedom structures

SIMULATION OF STRUCTURAL NONLINEAR SEISMIC RESPONSES BASED ON SIMULINK

A NEW SIMPLIFIED AND EFFICIENT TECHNIQUE FOR FRACTURE BEHAVIOR ANALYSIS OF CONCRETE STRUCTURES

Multi Linear Elastic and Plastic Link in SAP2000

Design of a Multi-Storied RC Building

Finite Element Modeling of the Load Transfer Mechanism in Adjacent Prestressed. Concrete Box-Beams. a thesis presented to.

Calculating Method for the Axial Force of Washover String During Extracting Casing in Directional Well

NONLINEAR ANALYSIS OF A DAM-RESERVOIR-FOUNDATION SYSTEM UNDER SPATIALLY VARIABLE SEISMIC EXCITATIONS

POST-PEAK BEHAVIOR OF FRP-JACKETED REINFORCED CONCRETE COLUMNS

Lecture-04 Design of RC Members for Shear and Torsion

ANALYSIS OF REINFORCED CONCRETE KNEE JOINTS BASED ON QUADRUPLE FLEXURAL RESITANCE. Hitoshi Shiohara 1 and Yong Woo Shin 2.

Fire Analysis of Reinforced Concrete Beams with 2-D Plane Stress Concrete Model

Strain-Based Design Model for FRP-Confined Concrete Columns

Chapter 5 Torsion STRUCTURAL MECHANICS: CE203. Notes are based on Mechanics of Materials: by R. C. Hibbeler, 7th Edition, Pearson

Kinetics of Particles

FRACTURE MECHANICS APPROACHES STRENGTHENING USING FRP MATERIALS

Towards The. Design of Super Columns. Prof. AbdulQader Najmi

Model for predicting the UHPFRC tensile hardening response

ME Final Exam. PROBLEM NO. 4 Part A (2 points max.) M (x) y. z (neutral axis) beam cross-sec+on. 20 kip ft. 0.2 ft. 10 ft. 0.1 ft.

FRICTION SLIPPING BEHAVIOR BETWEEN CONCRETE AND STEEL -AIMING THE DEVELOPMENT OF BOLTED FRICTION- SLIPPING JOINT -

Neuro -Finite Element Static Analysis of Structures by Assembling Elemental Neuro -Modelers

Analysis of Load-Settlement Relationship for Unpaved Road Reinforced with Geogrid

NEW DOWN-HOLE PENETROMETER (DHP-CIGMAT) FOR CONSTRUCTION APPLICATIONS

PLASTIC DEFORMATION CAPACITY OF H-SHAPED STEEL BEAM CONNECTED TO CONCRETE FILLED STEEL TUBULAR COLUMN

Generation of Biaxial Interaction Surfaces

ENGINEERING SCIENCE H1 OUTCOME 1 - TUTORIAL 4 COLUMNS EDEXCEL HNC/D ENGINEERING SCIENCE LEVEL 4 H1 FORMERLY UNIT 21718P

EDEM DISCRETIZATION (Phase II) Normal Direction Structure Idealization Tangential Direction Pore spring Contact spring SPRING TYPES Inner edge Inner d

A numerical parametric study on the plate inclination angle of steel plate shear walls

UNIVERSITY OF SASKATCHEWAN ME MECHANICS OF MATERIALS I FINAL EXAM DECEMBER 13, 2008 Professor A. Dolovich

D : SOLID MECHANICS. Q. 1 Q. 9 carry one mark each. Q.1 Find the force (in kn) in the member BH of the truss shown.

COMPARISON OF EXPERIMENTAL RESULTS WITH FEM ONES OF RECTANGULAR CFRP TUBES FOR FRONT SIDE MEMBERS OF AUTOMOBILES

2005 OpenSees Symposium OpenSees

Lecture-08 Gravity Load Analysis of RC Structures

FURTHER RESEARCH ON CHORD LENGTH AND BOUNDARY CONDITIONS OF CHS T- AND X-JOINTS

CHAPTER 5. T a = 0.03 (180) 0.75 = 1.47 sec 5.12 Steel moment frame. h n = = 260 ft. T a = (260) 0.80 = 2.39 sec. Question No.

CE5510 Advanced Structural Concrete Design - Design & Detailing of Openings in RC Flexural Members-

Multi-level seismic damage analysis of RC framed structures. *Jianguang Yue 1)

SHEAR CAPACITY OF REINFORCED CONCRETE COLUMNS RETROFITTED WITH VERY FLEXIBLE FIBER REINFORCED POLYMER WITH VERY LOW YOUNG S MODULUS

Entrance exam Master Course

A STUDY ON IMPROVEMENT OF PUSHOVER ANALYSIS

999 TOWN & COUNTRY ROAD ORANGE, CALIFORNIA TITLE PUSHOVER ANALYSIS EXAMPLE BY R. MATTHEWS DATE 5/21/01

SHEAR DESIGN EQUATIONS FOR FRP RC BEAMS

Seismic Performance of High-rise RC Wall-type Buildings in Korea

NUMERICAL SIMULATION OF THE INELASTIC SEISMIC RESPONSE OF RC STRUCTURES WITH ENERGY DISSIPATORS

Mechanics of Solids. Mechanics Of Solids. Suraj kr. Ray Department of Civil Engineering

SPREAD OF PLASTICITY ANALYSIS OF R/C BUILDINGS, SUBJECTED TO MONOTONIC SEISMIC LOADING

FLEXURAL ANALYSIS AND DESIGN METHODS FOR SRC BEAM SECTIONS WITH COMPLETE COMPOSITE ACTION

and F NAME: ME rd Sample Final Exam PROBLEM 1 (25 points) Prob. 1 questions are all or nothing. PROBLEM 1A. (5 points)

Chapter 5. Vibration Analysis. Workbench - Mechanical Introduction ANSYS, Inc. Proprietary 2009 ANSYS, Inc. All rights reserved.

Plasticity R. Chandramouli Associate Dean-Research SASTRA University, Thanjavur

Evaluation of dynamic behavior of culverts and embankments through centrifuge model tests and a numerical analysis

Parametric Identification of a Cable-stayed Bridge using Substructure Approach

Experimental and analytical studies on the pullout strength of round thread casing connections

Transcription:

International Conference on Mechanics and Civil Engineering (ICMCE 2014) A Discussion on Contact Condition in Simulation of RCFT Columns Alifujiang XIAMUXI 1, a, *, Akenjiang TUOHUTI 1, b, Akira HASEGAWA 2, c 1 College of Architecture and Civil Engineering, Xinjiang University, Urumqi 830047, China 2 Department of Environmental and Civil Engineering, Hachinohe Institute of Technology, Hachinohe, Japan a ilikyurt@xju.edu.cn, b akjt@xju.edu.cn, c hasegawa@hi-tech.ac.jp *Corresponding author Keywords: Numerical Simulation, Contact, CFT, RCFT, ADINA. Abstract. In numerical simulation of Concrete Filled Steel Tubular (CFT) columns the treatments to simulation the contact between steel tube and concrete differed greatly between the researchers, and there is also no any unified standard for the friction between the concrete and steel materials. To examine proper contact condition in simulating Reinforced Concrete Filled Steel Tubular (RCFT) columns with ADINA, numerical simulations are performed employing frictionless, frictional and bonding contact conditions between steel tube and concrete core, the analytical results are compared against experimental results, and the applicability of each contact on RCFT is observed, and a proper contact condition is proposed. Introduction The treatments in simulating the contact between steel tube and concrete in numerical analysis of Concrete Filled Steel Tubular structure (CFT) vary between the researchers. There have been examples of bond, frictional and frictionless contact models. Choi et al. [1] adopted frictionless contact condition in CFT columns under axial compression with ADINA. Hu et al. [2] modeled the contact in CFT columns subjected to axial compression with infinitesimal sliding and friction between the concrete and the steel tube. The contact surfaces between the concrete and the steel tube are allowed to separate but not to penetrate each other. The friction coefficient used in their analyses was 0.25. Li et al. [3] simulated the contact in concrete filled double skin tubular columns under axial compression using a Coulomb friction model in the tangential direction between surfaces of steel tube and concrete core with a friction coefficient of 0.6. Han et al. [4] employed Coulomb friction theory with a friction coefficient of 0.6 in contact modeling of CFT subject to torsion. Zeng et al. [5] employed Coulomb friction theory with a friction coefficient of 0.6 in simulating the contact between stiches and concrete. Hou et al. [6] employed Coulomb friction theory with a friction coefficient of 0.6 in contact modeling of CFT subject to impact force. Mao et al. [7] assumed complete bond between steel tube and concrete in modeling the steel-concrete composite beam joints. Kwak et al. [8] simulated cyclic behavior of CFT columns with bonded contact condition. All of those indicate the treatments of contact between steel tube and concrete differed greatly between the researchers. There is also no any unified standard for the friction between the concrete and steel materials as well. To examine the contact condition in simulating the Reinforced Concrete Filled Steel Tubular structure (RCFT) with ADINA, in this study, simulations are performed with above frictionless, frictional and bonding contact conditions, the analytical results are compared against experimental results, and the applicability of each contact on RCFT is discussed. Experimental Results The experimental results on RCFT by Suzuki [9] were used as a comparison standard for the simulation. Three RCFT columns were selected with three different steel tube thicknesses. The columns are labeled with a prefix T which implies the first capital letter of Thickness of steel 2014. The authors - Published by Atlantis Press 673

tube and the two digits of number which implies the thickness of steel tube after removing decimal point.. The experimental parameters for these selected columns are listed in Table1. Tab. 1 Parameters of RCFT Columns Labels t(mm) f sy (MPa) f ry (MPa) f co (MPa) Model of RCFT columns T45 4.5 296.0 235.0 19.2 T32 3.2 314.0 352.0 27.1 T23 2.3 327.3 295.0 44.3 (1) Material of steel tube is SS400, t is the thickness, f sy is the yield strength; (2) Material of axial reinforcement is SD295, diameter is 6mm, f ry is the yield strength; (3) Material of lateral reinforcement is SS400, diameter is 3mm, yield strength is 304MPa; (4) f co is the uniaxial compressive strength of concrete. Axial reinforcement Lateral reinforcement Steel tube 100mm 150mm 150mm 30mm 15=450mm Tab. 2 Modeling Parameters for Contact RCFT Columns and Labels T45 T32 T23 Coefficient of friction (μ) s T45-F00 T32-F00 T23-F00 0 Frictionless T45-F02 T32-F02 T23-F02 0.2 Frictional T45-F05 T32-F05 T23-F05 0.6 Frictional T45-F08 T32-F08 T23-F08 0.8 Frictional T45-FB T32-FB T23-FB - Bonded T45-T T32-T T23-T - Test Numerical Simulation Contact Model A constraint-function model built in ADINA is employed to simulate the contact condition between the steel tube and in-filled RC in RCFT. When two surfaces come into contact with each other, normal contact force λ acts on the contact surfaces (see Fig.1). The normal contact conditions can ideally be expressed as: g 0; 0; g 0 Where g is a gap. The inequality constraints are replaced by: w( g, ) g 2 2 g 2 N 0 Where ε N is a small user-defined parameter. The function is shown in Fig.1. Forces on contact surface Fig.2. It involves no inequalities, and is smooth and differentiable. The parameter ε N is set to 10-12 which is suitable for most applications and should rarely be modified. When two surfaces come into contact with each other, frictional force F T occurs in the direction tangential to the contact surfaces (see Fig.1). If we define a non-dimensional friction variable τ as: (1) (2) 674

FT (3) The standard Coulomb friction condition then can be expressed as: 1 (4) And 1 implies u 0 1 implies sign(u ) sign( ) Where u is the sliding velocity. A multilinear frictional constraint function formed v (u, τ) = 0 is used to regularize the friction, as shown in Fig.3, where ε N is a small parameter, and used only if friction is specified, the default value is 10-3. Thus, the possible states of the internal surface of steel tube and filled RC are: (i) the gap between the contactor nodes and/or segments of steel tube and the target segment of RC is closed; a compression force determined by Eq. (1) (g=0, λ>0) is acting onto the contactor nodes of steel tube and the nodes of steel tube kinematically slides along the target segments of RC with or without friction; (ii) the contactor nodes and/or segments of steel tube permanently attached or constrained to the target segment of RC, steel tube and RC then tied or bonded and deform together. Fig. 1 Forces on Contact Surface Fig. 2 Constraint Function Fig. 3 Constraint Function for Frictional Contact Parameters for Simulation Corresponding to the selected three experimental RCFT columns, one frictionless, three frictional and one bonded conditions for each column total 15 different RCFT column models are determined based upon the conditions of former studies. The decided modeling parameters are listed in Table 2. In the labels, the letter before - are labels of experimental RCFT columns, the F after - refers to Friction, number after F refers to decimal-point-removed coefficient of friction, B implies Bond, T after - implies the results of test. 675

Using the proposed material models for confined concrete, steel tube and reinforcement by Xiamuxi et al. [10], the determined RCFT models are simulated. Results of Simulation and Discussions The load-displacement curves of simulation are drawn in comparison with that of experiment for T45, T32 and T23 columns in Fig. 4. To examine the agreement of the analytical curves against experimental curves, the correlation coefficients R 2 of analytical curves are calculated against experimental curves and listed in Table 1, Table 2and Table 3, respectively for T45, T32 and T23, including the comparable factors in numerical simulation such as memory usage, solution time and convergence. (1)According to Table 4, the curves of boned condition are more close to the curves of experiment. Again, R 2 of bonded conditions are greater than that of other conditions, which means that the simulation results of bonded condition are better agreement with experimental results than other conditions. (2)No any clear difference can be observed between the curves of frictionless and all frictional conditions. (3)As far as the memory usage is concerned, the frictionless conditions showed minimum usage (say 47.3MB, 49.6 MB and 48.3 MB) while the bonded conditions showed maximum usage (say 55.4MB, 58.5MB and 59.2 MB), and there is no difference of memory usage between frictional conditions, which means that the frictionless contact consumes less computer resource compared with both frictional and bonded contact. (4)As far as the solution time is concerned, corresponding to the memory usage, the frictionless conditions showed fastest solution (say 0.77 Sec., 0.91 Sec. and 0.80 Sec.) while the bonded conditions showed slowest solution (say 1.46 Sec., 1.54 Sec. and 1.75 Sec.), and solution time increases along with the increase of friction coefficient. The frictionless conditions are faster than bonded conditions almost one times, which means that the frictionless contacts are faster and most time-saving compared with both frictional and bonded contact. (5)As far as the convergence is concerned, the boned conditions showed a little better convergence than other conditions. (6)The minimum value of R 2 among all columns is R 2 =0.8611 (with T23-F08), which means that all of the analytical results match experimental results well. Again, according to further observation on Fig.4, it can be noticed that the curves are in a good agreement until maximum load, and changes begin to happen between bonded and bond-less conditions only when larger plastic deformations started to happen, which mean that all of simulation results are under applicable range. Tab. 3 Comparisons of Simulation Results with T45 Labels Memory Usage(MB) One step solution time(sec.) Converged load steps R 2 T45-F00 47.3 0.77 100 0.9413 T45-F02 48.1 0.77 100 0.9368 T45-F05 48.1 0.82 100 0.9389 T45-F08 48.1 0.86 87 0.9495 T45-FB 55.4 1.46 100 0.9565 60.0 1.5 1.1 MB 50.0 40.0 30.0 Second 0.5 0.0 R 2 0.9 0.8 676

Tab. 4 Comparisons of Simulation Results with T32 Labels Memory Usage (MB) One step solution time (Sec.) Converged load steps R 2 T32-F00 49.6 0.91 100 0.9395 T32-F02 50.2 0.98 100 0.9361 T32-F05 50.2 0.97 100 0.9483 T32-F08 50.2 2 84 0.9131 T32-FB 58.5 1.54 100 0.9714 MB 70.0 60.0 50.0 40.0 Second 2.0 1.5 0.5 1.1 0.9 0.8 R 2 Tab. 5 Comparisons of Simulation Results with T23 Labels Memory Usage (MB) One step solution time (Sec.) Converged load steps Correlation coefficient against test (R 2 ) T23-F00 48.3 0.80 57 0.9070 T23-F02 49.5 0.90 64 0.8917 T23-F05 49.5 0.86 57 0.8737 T23-F08 49.5 0.87 66 0.8611 T23-FB 59.2 1.75 88 0.9684 MB 70.0 60.0 50.0 40.0 Second 2.0 1.5 0.5 R 2 1.1 0.9 0.8 Summary Fig. 4 Comparisons of Load-displacement Curves Summarizing the discussions above, it can be concluded that when model the contact between steel tube and concrete in RCFT columns subjected axial compression, both bonded contact and frictional and frictionless contacts are applicable. Bonded contact may be recommended to obtain more accurate results if time and computer resource is not concerned. On the contrary, the frictionless contact is recommended to obtain faster solutions. Acknowledgement The research described in this paper was financially supported by the Key Projects of Regional 677

Education Department of Xinjiang (XJEDU2014I006), the Starting-up Research Foundation of Xinjiang University for Doctors (BS130125), the Scientific Research Foundation for the Returned Overseas Chinese Scholars, State Education Ministry and the Regional Academic Discipline (Breeding) Program for Structural Engineering, Xinjiang. References [1]K.K. Choi and X. Yan: Analytical model of circular CFRP confined concrete-filled steel tubular columns under axial compression, Journal of Composites for Construction, ASCE, Vol.14, No.1, pp.125-128, 2010.1. [2]H.T. Hu, C.S. Huang, M.H. Wu et al.: Nonlinear analysis of axially loaded concrete-filled tube columns with confinement effect, Journal of Structural Engineering, ASCE, Vol.129 No.10, pp.1322-1329, 2003.10. [3]W. Li, L. H. Han and X.L. Zhao: Numerical investigation of concrete filled double skin tubular (CFDST) columns with preloads on steel tubes, The 2011 World Congress on Advances in Structural Engineering and Mechanics (ASEM'11 + ), Seoul Korea, pp.2345-2352, 2011.9. [4]L.H. Han, G. H. Yao and Z. Tao: Performance of concrete-filled thin-walled steel tubes under pure torsion, Thin-Walled Structures, Vol.45, No.1, pp.24-36, 2007.1. [5]Y. Zeng, C.C.Y. Leung and F.T.K. Au: Finite element analysis of in-situ stitches in precast concrete segmental bridges, The 2011 World Congress on Advances in Structural Engineering and Mechanics (ASEM'11 + ), Seoul Korea, pp.1563-1572, 2011.9. [6]C. C. Hou, L. H. Han and Z. Tao: Simulation on concrete-filled steel tubular members under transverse impact, The 2011 World Congress on Advances in Structural Engineering and Mechanics (ASEM'11 + ), Seoul Korea, pp.4189-4196, 2011.9. [7]P.F. Mao, D.L. Wang: Nonlinear finite element modeling of the interior steel-concrete composite beam joints, International Journal of Nonlinear Science, Vol.11, No.2, pp.173-179, 2011.4. [8]H.G. Kwak, J. H. Kwak and H.-G. Gang: Cyclic behavior of circular concrete filled steel tubular column, The 2011 World Congress on Advances in Structural Engineering and Mechanics (ASEM'11 + ), Seoul Korea, pp.1476-1484, 2011.9. [9]T. Suzuki: Study on new bridges that adopt hybrid structure, PhD thesis, Hachinohe Institute of Technology, Hachinohe Japan, 2008.2. [10]A. Xiamuxi and A. Hasegawa: A study on axial compressive behaviors of reinforced concrete filled tubular steel columns, Journal of Constructional Steel Research, JCSR, Vol. 76, pp. 144-154, 2012.9. 678