Physical Chemistry Advanced laboratory course. Excimer formation

Similar documents
Experiment 3: Radiative Lifetime Determination by Laser-Induced Fluorescence

Measuring (bio)luminescence and fluorescence

DETERMINATION OF RELATIVE FLUORESCENCE QUANTUM YIELD USING THE AGILENT CARY ECLIPSE

Fluorescence Spectrophotometry

The ROXI Colorimeter & Fluorimeter. Laboratory Application I. Colorimetric measurements via Beer s Law.

Photoluminescence Spectrometer (FLS980)

Measurement Examples. Excitation and Emission Scans. Steady State Fluorescence Anisotropy. Kinetic Measurements

Spectroscopy. Page 1 of 8 L.Pillay (2012)

Measurements of Liquid Scintillator Light Yield for Future Neutrino Experiments

Laser Induced Fluorescence of Iodine

Distribution equilibrium

Electrochemistry LEC Potentiometric ph titration (phosphoric acid in a soft drink) What you need: What you can learn about

1. Preliminary qualitative analysis of unknown substances (liquid or solid).

Supplementary information

A Guide to Recording Fluorescence Quantum Yields

Photochemistry of Nitro-Polycyclic Aromatic Hydrocarbons. August 9, 2011

Time Resolved Pulsed Laser Photolysis Study of Pyrene Fluorescence Quenching by I - Anion

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Determination of Volatile Substances Proof of Food Adulteration

two slits and 5 slits

Experiment 4 Radiation in the Visible Spectrum

Bio 120 Lab 5: Quantitative Analysis

Investigating Transition Metal Complexes

Chem 310 rd. 3 Homework Set Answers

Introduction. Molecules, Light and Natural Dyes. Experiment

Determining Riboflavin Content in a Multivitamin: Things to do before the lab

The Fluorometric Determination of Acetylsalicylic Acid in an Aspirin Tablet

Supporting Information

Experiment 18 - Absorption Spectroscopy and Beer s Law: Analysis of Cu 2+

Chem Homework Set Answers

Dynamic Light Scattering Study of Polymer Chain Dimensions

Beer-Lambert law Decomposition of the manganese oxalate ion

Electronic Supporting Information

Awanish Kumar, Anjeeta Rani and Pannuru Venkatesu* Department of Chemistry, University of Delhi, Delhi

Department of Chemistry Physical Chemistry Göteborg University

Chemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES

Time Resoled Pulsed Laser Photolysis Study of Pyrene Fluorescence Quenching by I - Anion

Fluorescence and Phosphorescence of Erythrosin

ACTIVITY 1. Exploring Light from Gases

Polystyrene Cyclization Using Pyrene Excimer Formation. Effect of Geminate Pairs in Good Solvents

Cobalt-Porphyrin /Dansyl Piperazine Complex Coated Filter. Paper for Turn on Fluorescence Sensing of Ammonia Gas

Biofuel Enzyme LAB. Name

Spectrometer User s Guide

Introduction to Spectroscopy: Analysis of Copper Ore

MIXTURES, COMPOUNDS, & SOLUTIONS

Introduction to Spectroscopy: Analysis of Copper Ore

Introduction to Spectroscopy: Analysis of Copper Ore

A BODIPY-based fluorescent probe for the differential

Spectroscopy II Introduction: Spectrophotometry and Fluorometry

Determination of an Equilibrium Constant

Determining the Concentration of a Solution: Beer s Law

symphony Reference Electrodes

LAB #3: FLUROESCENCE SPECTROSCOPY AND ELECTRON TRANSFER (This lab is adapted from the U of MN Phsyical Chemistry lab manual)

A Simple Fluorescein Derived Colorimetric and Fluorescent off - on Sensor For The Detection of Hypochlorite

Experiment#1 Beer s Law: Absorption Spectroscopy of Cobalt(II)

A Determination of DNA-DAPI Binding using Fluorescence Spectroscopy

Cyanine Dyes as Ratiometric Fluorescence Standards for the Far-Red Spectral Region

Experiment 6: Determination of the Equilibrium Constant for Iron Thiocyanate Complex

Department of Chemistry of The College of Staten Island and The Graduate Center, The City University of

Supporting Information

Introduction to Spectroscopy: Analysis of Copper Ore

Spectrophotometry and the Absorption Spectrum of Chlorophyll. Kathryn Dockins Plant Physiology and Lab Spring Prof. J.

6. A solution of red Kool-Aid transmits light at a wavelength range of nm.

Solution Experiment Collin College

FLS980 Series Reference Guide

user manual blotting Hoefer PR648 Slot blot manifold um PR648-IM/Rev.F0/08-12

OPERATING INSTRUCTIONS

Chem 204. K ow and the Rule of Five. with an extended interlude of how to measure concentra3ons of molecules in fluid solu3on

FLUORESCENCE APPLICATIONS

CH 112 Special Assignment #4 Chemistry to Dye for: Part C

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI

HIGH-TEMPERATURE CADMIUM-FREE NANOPHOSPHORS FOR DAYLIGHT-QUALITY WHITE LEDS

Solution reduction synthesis of amine terminated carbon quantum dots

Energy transfer and optical gain studies of FDS: Rh B dye mixture investigated under CW laser excitation

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy

Chemistry 351L Wet lab # 2 The Particle-in-a-Box Model for Describing the Electronic Transitions in Conjugated Dye Molecules

DETERMINATION OF K c FOR AN EQUILIBRIUM SYSTEM

The Thermodynamics of the Solubility of Borax

Comparison of the Diffusion Coefficients Obtained for Latex Film Formation Studied by FRET and Pyrene Excimer Formation

Supplementary Information

Practical 1P4 Energy Levels and Band Gaps

Fluorescence Workshop UMN Physics June 8-10, 2006 Basic Spectroscopic Principles Joachim Mueller

Supporting Information

NANOSCIENCE: TECHNOLOGY AND ADVANCED MATERIALS

Triaryl Amine N-Functionalised 2,7-Linked Carbazole Polymers as a. New Class of Blue Emitting Materials for LED Applications

Introduction to Spectroscopy: Analysis of Copper Ore

Manufacturing process control with PAT Substitution of off-line HPLC & GC by in-line IR spectroscopy

The following are excerpted from the lab manual with a couple of extra figures for your guidance.

Practical 1P4 Energy Levels and Band Gaps

Lab Investigation 4 - How could you make more of this dye?

Laser Dissociation of Protonated PAHs

Basics of UV-Visible Spectroscopy *

THIS IS A NEW SPECIFICATION

The Synthesis and Analysis of Aspirin

Electronic Supplementary Information. Ultrafast Charge Separation in Supramolecular Tetrapyrrole- Graphene Hybrids

Versuchsanleitungen zum Praktikum Physikalische Chemie für Anfänger 1

Chapter 6 Photoluminescence Spectroscopy

Supporting Information. Synthesis and Upconversion Luminescence of BaY 2

Stimulating Electrocatalytic Oxygen Reduction Activity on Nitrogen doped Graphene through Noncovalent Molecular Functionalisation

The student s results are shown in the table below. Time / minutes Time / minutes

Transcription:

Physical Chemistry Advanced laboratory course Excimer formation 02-2010

Experimental Make a 1*10-2 M solution of pyrene (C 16 H 10, molecular weight M = 202.25 g/mol) in methylcyclohexane. From this solution, make three dilutions with c = 5*10-3, 2.5*10-3 and 1*10-3 M. 20 ml of each solution is a sufficient amount for the measurements. Measure the emission spectra for these four solutions at room temperature with the Varian Cary Eclipse spectrofluorometer. Use an excitation wavelength of 370 nm and measure the emission spectrum at the 375-500 nm range. Use the following settings: Excitation slit 5 nm, Emission slit 2,5 nm, Scan control medium, Excitation filter Auto, Emission filter open. Set the PMT Detector voltage at first to the medium value, but if necessary, change the voltage setting to manual and a smaller value, so that the fluorescence of the most concentrated sample stays withing the measurement scale. Also, set the intensity values visible in the spectra (label peaks Y labels, threshold 30.0 ). Do the temperature-dependent measurements for the 5*10-3 M solution. In fluorescence measurements the oxygen dissolved in the solution will cause problems by quenching the fluorescence. The amount of dissolved oxygen is also temperature dependent, so in temperature-dependent measurements it may cause a significant error. This is why the oxygen should be removed from the solution by bubbling nitrogen through the solution. Use the pasteur-pipette attached to the nitrogen hose in the fume cupboard. Detach the cuvette holder from the spectrometer and set the cuvette in it. Fill the cuvette with the 5*10-3 M pyrene solution and put the tip of the pipette on the bottom of the cuvette. Adjust the nitrogen flow rate with the needle valve. Bubble nitrogen through the solution for 5-7 minutes and then close the cuvette with a stopper with a small hole for the thermometer probe. Put the thermometer probe into the solution through the hole in the stopper and put the cuvette into the spectrometer. Warm the solution to about 30 C and let the temperature stabilize for about 5 minutes. Measure the emission spectrum as before. Write down the temperature during the measurement and save the spectrum. Repeat the measurement for temperatures of 40, 50, 60, 65, 70, 75, 80, 85, 90 and 95 C. Note: The sample in cuvette does not warm up exactly to the value shown in the temperature controller, so

use as the set value for example 31, 41, 52, 62, 68, 73, 79, 84, 90, 95 and 99, and make your calculations using the real values shown by the thermometer. After measurements, set the temperature controller value back to about room temperature so that it won t start heating immediately when the next measurer turns it on. For the report Compare the fluorescence spectra of the solutions with different concentrations. Concentrate especially on the relative changes in the excimer and monomer contribution to the spectra. Describe how and why the concentration affects the excimer formation. Plot the fluorescence spectra in different temperatures in the same graph. Observe how the spectra change as a function of temperature and explain the changes. Tabulate the monomer and excimer emission intensities (R M and R D ) at the maximum intensity wavelenghts in different temperatures. The wavelengths of the maximum intensity may change a little as a function of temperature, but use the same wavelength for all measurements. Plot a graph of R M vs. R D at temperatures between 60 and 85 C. From the slope of this plot determine the constant a/b to get the constant b/a for equation (18). Determine the enthalpy and entropy of formation, H and S from equation (18) using an appropriate linear fit. In the equation, use the pyrene concentration and the constant b/a determined earlier, and the measurements at temperatures between 60 and 85 C. Then determine the excimer binding energy B and the ground state repulsion energy R. Estimate the errors for H, S, B and R and compare your results to the literature values: H = -7.8 kcal mol -1 (in cyclohexane) S = -18.5 cal mol -1 K -1 (in ethanol) R = 7.9 kcal/mol (in ethanol)

Questions for discussion 1. In excimer lasers, the lasing is based on the emission of an excimer formed of a rare gas atom and a halogen atom. Why is it easy to make a laser this way? Hint: Think about the population of the lasing states. 2. Does the following statement make sense: The ground state of an excimer is an excited state. 3. The probability that the ends of a linear polymer molecule come into close proximity can be probed by attaching pyrene probes to the ends of the molecule. How does such a technique work? 4. For some excimers, the fluorescence emission can be observed also at low temperatures. However, the excimer emission nearly vanishes when the solvent becomes glassy or crystalline, why? References: The English instructions: Halpern A.M., Experimental Physical Chemistry 2nd Edition, 1997, Prentice-Hall, Inc Literature values: Stevens and Ban, Trans. Faraday. Soc. 60:1515 (1964)