Metabolomics Batch Data Analysis Workflow to Characterize Differential Metabolites in Bacteria

Similar documents
A Q-TOF Generated, Metabolomics- Specifi c LC/MS/MS Library Facilitates Identifi cation of Metabolites in Malaria Infected Erythrocytes

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Pharmaceutical Impurity Identification and Profiling Using Agilent Q-TOF LC/MS Combined with Advanced MassHunter Data Processing Software

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Application Note. Edgar Naegele. Abstract

MassHunter TOF/QTOF Users Meeting

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Agilent All Ions MS/MS

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Application Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Agilent METLIN Personal Metabolite Database and Library MORE CONFIDENCE IN COMPOUND IDENTIFICATION

C Glucose Qualitative Flux Analysis in HepG2 cells

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Making Sense of Differences in LCMS Data: Integrated Tools

NEW TOOLS FOR FINDING AND IDENTIFYING METABOLITES IN A METABOLOMICS WORKFLOW

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

LC/Q-TOF Workflows for Comprehensive Micropollutant Analysis

MassHunter Software Overview

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Computer-assisted analysis of complex natural product extracts

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Accurate Mass Analysis of Hydraulic Fracturing Waters

Extend Your Metabolomics Insight!

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

Fast and Flexible Optimization of Modifier Concentrations Using an Agilent 1290 Infinity LC System with Blend Assist

Quantitation of Cystine and Identification of Related Metabolites in White Blood Cells Using a High Resolution Accurate Mass LC/MS Approach

The new Water Screening PCDL

Analyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 1: Dyes and Pigments. Application. Introduction. Authors. Abstract.

Application Note. Edgar Naegele. Abstract

Screening and Quantitation of 240 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Die Nadel im Heuhaufen

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate Yu 3

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Identifying Disinfection Byproducts in Treated Water

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

Analysis of Extractable and Leachable (E&L) Compounds Using a Low-Energy EI-Capable High Resolution Accurate Mass GC/Q-TOF

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

QTOF Training Manual

Ultrafast Analysis of Methadone and Metabolite EDDP in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Determination of EU-Banned Disperse Dyes by LC/MSD TOF Application

Characterization and Classification of Heroin from Illicit Drug Seizures Using the Agilent 7200 GC/Q-TOF

Agilent G3212 GC-APCI Source

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

Key Features of Targeted Metabolite Screening. Using the TripleTOF System, an Accurate Mass Metabolite Spectral Library and MasterView Software

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Determination of Chlorinated Acid Herbicides in Soil by LC/MS/MS Application Note

Analysis of Polyphenols in Saffron Petal Extracts with UHPLC/UV/MS

Application Note. Abstract. Authors. Environmental

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Application Note. Author. Abstract. Pharmaceutical QA/QC. Vinayak A.K Agilent Technologies Bangalore, India

Application Note. Authors. Abstract. Introduction. Environmental

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Definitive EtG/EtS LC-MS/MS Analysis:

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

Using TOF for Screening and Quantitation of Sudan Red Colorants in Food Application

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

TOF/QTOF Users Meeting. Jim Lau, Agilent Technologies.

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Taking Full Advantage of UHPLC with Agilent 6460A Triple Quadrupole MS. Outline

C HA R AC T E RIZ AT IO N O F INK J E T P RINT E R C A RT RIDG E INK S USING A CHEMOMETRIC APPROACH

Compounding insights Thermo Scientific Compound Discoverer Software

PosterREPRINT COMPARISON OF PEAK PARKING VERSUS AUTOMATED FRACTION ANALYSIS OF A COMPLEX PROTEIN MIXTURE. Introduction

Using the Agilent 1290 Infinity II Multicolumn Thermostat with Extreme Temperatures and Flow Rates

Analysis of Cannabinoids and Amphetamines in Serum by RRLC/Triple Quadrupole Mass Spectrometry Using a Multimode Ion Source. Application.

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Transcription:

Metabolomics Batch Data Analysis Workflow to Characterize Differential Metabolites in Bacteria Application Note Authors Yuqin Dai and Steven M. Fischer Agilent Technologies, Inc. Santa Clara, CA, USA Abstract An accurate mass Q-TOF LC/MS workfl ow for discovery metabolomics was used to study a bacterium in early and late stationary phases. The use of software that can process data in batch-mode made the data analysis more effi cient and automated. A total of 488 features from the positive ion data and 623 features from the negative ion data were found using Agilent MassHunter Profi nder (batch feature extraction software). Statistical analyses using Mass Profi ler Professional (MPP) revealed features whose abundance differed signifi cantly in early stationary phase versus late stationary phase. From the positive ion data, 57 features were found to have higher abundances in the early stationary phase than in the late stationary phase. While in the negative ion data, 52 features exhibited higher abundances in the early stationary phase compared to the late stationary phase. To understand the biological and biochemical context of the metabolomics data, we annotated and identifi ed over 100 differential features using database searching, accurate mass MS/MS library matching, and MS/MS molecular structure correlation.

Introduction The growth of bacteria has been studied for more than a century, including the now classical definition of the phases of growth identified by Jacob Monod 1. It was found that cells remain alive and metabolically active during the late stationary phase, but often respond differently to stimuli or stresses during the early part of stationary phase compared to the late stationary phase. Researchers hypothesize that one or more metabolites produced during the stationary phase may render a bacterium less viable in late stationary phase or, alternatively, that a protective metabolite may be lost during the progression of stationary phase. To our knowledge, there is no information available about the characteristics of those metabolites. For LC/MS analysis, the sample was resuspended in 500 µl of water/acetonitrile (3:7 v/v) solvent, then vortexed and centrifuged. The supernatant was transferred from an Eppendorf tube to a clean LC/MS vial. Instrumentation LC/MS Analysis was performed using an Agilent 1290 Infinity LC system coupled to either an Agilent 6230 TOF system or an Agilent 6550 ifunnel Q-TOF system. The LC system consisted of the following modules: Agilent 1290 Infinity Binary Pump (G4220A) Agilent 1290 Infinity Autosampler with a thermostat (G4226A) Dynamic mass axis calibration was achieved by continuous infusion of a reference mass solution using the isocratic pump. Tables 1 and 2 summarize the optimized LC and MS conditions. Data analysis software Agilent MassHunter Qualitative Analysis (Qual) B.07.00 Agilent MassHunter Profinder B.06.00, service pack 1 Agilent Mass Profiler Professional (MPP) B.13.0 Agilent MassHunter Molecular Structure Correlator (MSC) B.07.00 Pathway to PCDL B.07.00 Here we present a Q-TOF LC/MS metabolomics approach to investigate differential metabolites of a bacterium in the early stationary versus late stationary phase. The Agilent suite of data processing software makes feature finding, statistical analysis, and identification easier. This enables rapid transformation of complex raw data into biologically relevant metabolite information. Experimental Sample preparation Cell cultures were harvested either in early or late stationary phase, rinsed twice with phosphate-buffered saline to remove any residual extracellular media, and then rinsed with water to remove the buffer. The suspended cells were then centrifuged to form a pellet and the water was decanted. To the cell pellets was added 0.5 ml of MeOH at 80 C and then 1.5 ml of 50 % MeOH/H 2 O at 4 C. The cells were mechanically lysed, and the crude extract was spun at 48,000 g for 1 hour, then the supernatant was collected. An aliquot of 500 µl of supernatant was added to a 3 kda Nanosep filter and spun at 14,000 g, the filtrate was collected, vacuum dried, and held at 60 C until analysis. Agilent 1290 Infinity Thermostatted Column Compartment (G1316C) Agilent 1100 Series Isocratic Pump (G1310) with a 100:1 splitter (p/n G1607-60000) Table 1. LC parameters. Parameter Agilent 1290 Infinity LC system Analytical column Cogent Diamond Hydride HPLC Column, 2.1 150 mm, 4 µm, 100 A (p/n 70000-15P-2), Microsolv Technology Corporation Guard column Agilent ZORBAX SB-C8, 2.1 30 mm, 3.5 µm (p/n 827700-936) Column temperature 60 C Injection volume 5 µl for profiling experiment on the Agilent 6230 TOF 10 µl for identification experiment on the Agilent 6550 Q-TOF Autosampler temperature 4 C Mobile phase for positive ion mode Mobile phase for negative ion mode Flow rate Gradient for positive ion mode Gradient for negative ion mode Stop time Post time A) 50 % water/50 % isopropanol containing 0.1 % formic acid B) 3 % water/97 % acetonitrile containing 0.1 % formic acid A) 50 % water/50 % isopropanol/0.025 % formic acid and 5 µm EDTA B) 10 % water/90 % acetonitrile/5 mm ammonium formate/5 µm EDTA, ph=7 0.6 ml/min 0 1 minutes 97 %B 1 15 minutes 97 %B to 10 %B 0 1 minutes 99 %B 1 15 minutes 99 %B to 20 %B 15 minutes 5 minutes 2

LC/MS metabolomics workflow A high-resolution Q-TOF LC/MS metabolomics workflow (Figure 1) was developed for unbiased metabolomics study of a bacterium in the early stationary and late stationary phase. The workflow was as follows: 1. Acquire data from extracts in TOF mode in positive and negative ion modes, respectively. 2. Find features from raw data using the Agilent MassHunter Profinder 2 Batch Recursive Feature Extraction algorithm. 3. Perform differential analysis and annotation using MPP. 4. Conduct targeted MS/MS analysis of the differential features of interest using Q-TOF LC/MS. 5. Use Qualitative Analysis for metabolite identification based on MS/MS spectra matches or use Molecular Structure Correlator (MSC) software to aid structural elucidation of putative metabolites. Table 2. MS parameters. Parameter Agilent 6230 TOF system Ion mode Positive and Negative Source Agilent Dual ESI Capillary voltage 3,500 V (±) Dry gas temperature 350 C Dry gas flow 10 L/min Nebulizer pressure 45 psi Fragmentor 100 V MS range 25 1,600 m/z MS acquisition rate 2 spectra/sec Reference mass Positive ion mode: 64.01577 and 922.009798 Negative ion mode: 68.9957 and 966.0007 Reference pump flow 0.5 ml/min (positive and negative ion modes) Reference delivery Agilent 1100 isocratic pump with 100:1 splitter (p/n G1607-60000) Instrument mode Extended dynamic range (2 GHz) Parameter Agilent 6550 Q-TOF system Ion mode Positive and Negative Source Agilent Dual ESI Capillary voltage 3,500 V (±) Dry gas temperature 200 C Dry gas flow 15 L/min Nebulizer pressure 45 psi MS range 50 1,700 m/z MS acquisition rate 3 spectra/sec MS/MS range 25 1,700 m/z MS/MS 2 spectra/sec, Targeted MS/MS acquisition rate Isolation width Medium (~4 m/z) Collision energy 10 40 ev Reference mass Positive ion mode: 64.01577 and 922.009798 Negative ion mode: 68.9957 and 1033.9881 Reference pump flow 0.6 ml/min (positive ion mode) 0.5 ml/min (negative ion mode) Reference delivery Agilent 1100 Isocratic Pump with 100:1 splitter (p/n G1607-60000) Instrument mode Extended dynamic range (2 GHz) MS data acquisition for profiling (TOF) Differential analysis (MPP) ID (Qual and MSC) 1 2 2 3 4 5 Feature extraction (Profinder) MS/MS data acquisition for ID (Q-TOF) Figure 1. LC/MS metabolomics workflow for profiling and identification of bacterium metabolites. 3

Metabolite profiling by TOF LC/MS In principle, either a TOF or a Q-TOF can be used for metabolite profiling. If a laboratory only has one instrument, a Q-TOF is the preferred instrument due to its capability to perform both profiling and MS/MS analysis for identification. However, if laboratory sample volume requires multiple instruments, a combination of TOF and Q-TOF instrumentation is more cost-effective. For this study, we demonstrate the use of 6230 TOF for profiling and 6550 Q-TOF for identification. The difference in the metabolome of a bacterium in the early versus late stationary phase was assessed by performing metabolite profiling on cell extracts of 10 separate cultures from the early stationary phase and 9 cultures from the late stationary phase. A 6230 TOF LC/MS was used to profile these samples in positive and negative ion modes. Chromatographic separation used an aqueous normal phase (ANP) column to maximize polar metabolite coverage. Figure 2 shows the metabolite profiling results of the cell extracts obtained in the negative ion mode. An overlay of 38 total ion chromatograms (TICs) from 19 cell extracts shows minimal retention time variation across the chromatograms. The reproducibility of retention time is crucial in discovery metabolomics studies, because it is used for peak matching across different samples. Batch data feature extraction using Agilent MassHunter Profinder One of the bottlenecks in metabolomics data analysis is the time-consuming feature extraction from large amounts of complex raw data. MassHunter Profinder Software was designed to increase throughput using automated batch data processing. In this study, Profinder found 488 features from the positive ion data, and 623 features from the negative ion data (Figure 3) based on the user-defined compound filtering criteria and manual curation. The resulting features were subsequently imported into MPP (B.13.0) for differential analysis. 10 7 1.7 1.6 1.5 1.4 1.3 1.2 Counts Results and Discussion 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 1 2 3 4 5 7 6 8 9 Acquisition time (min) 10 11 12 13 14 Figure 2. Thirty-eight overlaid total ion chromatograms (TICs) from 19 cell extracts in ESI negative ion mode. Each sample was injected twice. Total 623 features found Early Stationary Late Stationary Figure 3. Untargeted feature extraction result of the negative ion MS data from the cell extracts in the early and late stationary phase using the Profinder Batch Recursive Feature Extraction algorithm. 4

Differential analysis and annotation using MPP To determine the differential features of a bacterium in the early versus late stationary phase, the resulting features were evaluated by MPP using the Filter on Volcano Plot algorithm with a cutoff of P < 0.005 and fold change (FC) > 2. The statistical results yielded features whose abundance differed significantly in the early stationary versus late stationary phase. For the positive ion data, 98 of the 488 features displayed statistical significance, and 57 of them were found to have higher abundances in the early stationary phase compared to the late stationary phase. Likewise, we detected 152 of 623 features that were significantly differential in the negative ion data (Figure 4), and 52 of them had higher abundance in the early stationary than in the late stationary phase (blue solid square dots). To understand the biological and biochemical context of the metabolomics data, we performed annotation for those differential features using the ID browser tool in MPP and accurate mass database matches with 10 ppm mass tolerance. The three databases that were queried were Agilent-Metlin, KEGG, and BioCyc. Both the KEGG and BioCyc databases were created using Agilent Pathway to PCDL software. Figure 5 shows the ID browser result for a set of differential features acquired in the negative ion mode. By clicking a compound, in this case L-Leucine, in the compound list table, the corresponding MS spectrum results, detailed information of isotopic peaks, and chemical structure are displayed. Users can quickly review and rank hits based on parameters such as accurate mass, isotopic pattern, retention time, and match scores to select the best hit for annotation. -Log10(corrected Pvalue) 4 3 2 1-4 -2 0 Log2(fold change) Figure 4. Volcano plot of the features in the early versus the late stationary phase (negative ion data). Red dots represents those features whose abundances are lower in the early stationary phase than in the late stationary phase (P < 0.005, FC > 2). Blue dots represents those features whose abundances are higher in the early stationary phase than in the late stationary phase (P < 0.005, FC > 2). 4 1 2 4 2 3 Figure 5. ID browser result for a set of differential features detected in the negative ion mode. (1) MS spectrum result, (2) detail information of isotopic peak, (3) structure of the annotated compound, and (4) compound list. 5

Compound identification and software-assisted structure elucidation To validate the initial annotations, targeted MS/MS experiments were performed for those differential features of interest using a 6550 Q-TOF LC/MS. Compound identification and structure elucidation were achieved using two approaches. First, LC/MS/MS data were processed using the Find by Targeted MSMS tool in the MassHunter Qualitative Analysis software. The MS/MS spectrum generated was then compared to the Agilent-Metlin metabolite library containing accurate mass MS/MS information. Figures 6 and 7 showed a differential feature that was identified as nicotinic acid with high confidence. The mirror image plot (middle) showed excellent matches of the acquired sample spectrum (top) with the library standard spectrum (bottom) for both m/z values and abundances of the precursor and fragment ions with reverse match scores of 97 for the positive ion data and 99 for the negative ion data. When an acquired MS/MS spectrum had poor or no matches to the Agilent-Metlin MS/MS library, the other approach using MSC software was employed. MSC 3 proposes theoretical fragment masses from proposed molecular structures by using a systematic bond-breaking approach. It then correlates those theoretical fragment masses with the observed accurate mass fragment ions for a compound of interest. MSC calculates an overall correlation score (goodness-of-fit) from the individual score for each fragment ion; one or multiple substructure candidates may be suggested. A Sample MS/MS spectrum B Mirror image plot C Library MS/MS spectrum Nicotinic acid Figure 6. Compound structure identification using MS/MS spectra matching with a reverse match score of 97 for nicotinic acid in positive ESI mode. The reverse score reflects ion matches for those peaks from the library standards that are reflected in the spectra acquired from the sample. (A) sample MS/MS spectrum, (B) mirror image plot, (C) library MS/MS spectrum. Collision energy (CE) of 20 ev was used to acquire MS/MS spectra. A Sample MS/MS spectrum B Mirror image plot C Library MS/MS spectrum O OH N Nicotinic acid Figure 7. Compound structure identification using the MS/MS spectra matching with a reverse match score of 99 for nicotinic acid in negative ESI mode. The reverse score reflects ion matches for those peaks from the library standards that are reflected in the spectra acquired from the sample. (A) sample MS/MS spectrum, (B) mirror image plot, (C) library MS/MS spectrum. Collision energy (CE) of 10 ev was used to acquire MS/MS spectra. 6

Multiple data files were batch processed in MSC B.07.00 by searching them against the Agilent-Metlin, the Pathway to PCDL generated KEGG and Biocyc, and web-based PubChem and ChemSpider databases. The ability to search multiple databases increases the chance of finding structure hits, but it comes with the cost of decreasing selectivity. This is shown in Figures 8 and 9, where the Agilent-Metlin database was searched first, and three compounds at m/z 187.1114, 203.1041, and 307.1512 got structure hits (Figure 8). For the m/z 187.1114 ion, nine structures were found. By querying the PubChem database using the same MSC filtering criteria, structure hits were returned for all six compounds (Figure 9) and 300 structures found for the m/z 187.1114 ion. The structure interpretation of the MS/MS spectrum for the m/z 187.1114 ion is shown in Figure 10. All fragment ions were labelled with the most plausible fragment structure proposed by the MSC. Using this approach, we were able to quickly interpret the resulting MS/MS spectra to support annotation for those significant features. Figure 8. MSC results obtained by searching the Agilent-Metlin database. Figure 9. MSC results obtained by searching the web-based PubChem database. Glycyl-L-leucine Figure 10. Structure interpretation of MS/MS spectrum for m/z 187.1088 ion using MSC and Agilent-Metlin database. 7

Conclusions An easy-to-use Q-TOF LC/MS based workflow is presented for a discovery metabolomics study of a bacterium. The Agilent software tools (Profinder, MPP, and MSC) enabled high efficiency and high quality feature extraction, statistical analysis, annotation, and identification. The results from this study revealed interesting bacterium metabolic variations in the early versus late stationary phase. References 1. Monod, J. The Growth of Bacterial Cultures. Annual Review of Microbiology 1949, 3, pp 371-394. 2. MassHunter Profinder: Batch Processing Software for High Quality Feature Extraction of Mass Spectrometry Data, Agilent Technologies Technical Overview, publication number 5991-3947EN, 2014. 3. S. Joseph, Y. Dai, Pharmaceutical Impurity Identification and Profiling Using Agilent Q-TOF LC/MS Combined with Advanced MassHunter Data Processing Software, Agilent Technologies Application Note, publication number 5991-1375EN, 2012. www.agilent.com/chem This information is subject to change without notice. Agilent Technologies, Inc., 2015 Published in the USA, April 28, 2015 5991-5706EN