Introduction. Chapter 1. Learning Objectives

Similar documents
Chemistry Instrumental Analysis Lecture 37. Chem 4631

Chapter 31 Gas Chromatography. Carrier Gas System

Principles of Gas- Chromatography (GC)

The Theory of HPLC. Quantitative and Qualitative HPLC

CEE 772: Instrumental Methods in Environmental Analysis

Introduction to GC/MS

Liquid Chromatography

Analytical Chemistry

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

LC-MS Based Metabolomics

Instrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai

Mass Spectrometry. Electron Ionization and Chemical Ionization

TANDEM MASS SPECTROSCOPY

Lecture 15: Introduction to mass spectrometry-i

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Gas Chromatography. A schematic diagram of a gas chromatograph

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

Gas Chromatography. Introduction

Chapter 23 Introduction to Analytical Separations

Molecular Mass Spectrometry

Gas Chromatography (GC)

Introduction to Chromatographic Separations

Choosing the metabolomics platform

Chromatography and other Separation Methods

CEE 772: Instrumental Methods in Environmental Analysis

CEE 772: Instrumental Methods in Environmental Analysis

Multi-residue analysis of pesticides by GC-HRMS

CHMC 16 Instrumental Analysis (Syllabus)

Hplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved In Method Development And Validation

Hplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved In Method Development And Validation

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages

Introduction to Pharmaceutical Chemical Analysis


Chemistry Instrumental Analysis Lecture 34. Chem 4631

Fall 2012 Due In Class Friday, Oct. 19. Complete the following on separate paper. Show your work and clearly identify your answers.

High Performance Liquid Chromatography

The Claviature of Gas Analysis

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

2501 High Performance Liquid Chromatography

Chapter content. Reference

The Analysis of Organophosphate Pesticides by LC/MS Application

Routine MS Detection for USP Chromatographic Methods

CHEM 429 / 529 Chemical Separation Techniques

penta-hilic UHPLC COLUMNS

GUIDELINES ON THE USE OF MASS SPECTROMETRY (MS) FOR IDENTIFICATION, CONFIRMATION AND QUANTITATIVE DETERMINATION OF RESIDUES CAC/GL

Gas Chromatography. 1. Experiment Category: 2. Experiment Name: 3. Date and Issue number: 4. Instructor Name: 5. Institution: Ain Shams University

for the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York

WADA Technical Document TD2003IDCR

High Pressure/Performance Liquid Chromatography (HPLC)

CHROMATOGRAPHY AND MASS SPECTROMETER

CHAPTER 6 GAS CHROMATOGRAPHY

LEARNING OBJECTIVES CHEM 212: SEPARATION SCIENCE CHROMATOGRAPHY UNIT. Thomas Wenzel, Bates College. In-class Problem Set Extraction.

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative.

Chemistry Gas Chromatography: Separation of Volatile Organics

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Luminescence transitions. Fluorescence spectroscopy

TR ACE ORGANIC. lgcstandards.com/foodandenvironment

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

Chapter 26. An Introduction to Chromatographic Separations. Chromatography

Selecting an LC/MS Interface Becky Wittrig, Ph.D.

The Theory of HPLC. Ion Pair Chromatography

Analysis of Polar Metabolites using Mass Spectrometry

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n

Chromatographic Analysis

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

3) In CE separation is based on what two properties of the solutes? (3 pts)

Mass Spectrometry in MCAL

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Finnigan LCQ Advantage MAX

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications

Chromatography & instrumentation in Organic Chemistry

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Chapter 27: Gas Chromatography

Chromatography. Gas Chromatography

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative.

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Quality control analytical methods- Switch from HPLC to UPLC

Chromatography. Mrs. D. MEENA MPharm PA & QA KTPC

Electrospray Ion Trap Mass Spectrometry. Introduction

Gas chromatography. Advantages of GC. Disadvantages of GC

Chromatographic Methods: Basics, Advanced HPLC Methods

LC Technical Information

NaturalFacts. Introducing our team. New product announcements, specials and information from New Roots Herbal. April 2009

Molecular Mass Spectrometry

HYPHENATED TECHNOLOGY GUIDE

HPLC Background Chem 250 F 2008 Page 1 of 24

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

Analysis of Organic Light Emitting Diode Materials by UltraPerformance Convergence Chromatography Coupled with Mass Spectrometry (UPC 2 /MS)

Chemistry Instrumental Analysis Lecture 27. Chem 4631

Presentation Basic Introduction to Instrumentation Matrix Effects Challenges

Skoog/Holler/Crouch Chapter 26 Principles of Instrumental Analysis, 6th ed. CHAPTER 26

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

High Performance Liquid Chromatography

HYPHENATED TECHNOLOGY GUIDE

IN QUALITATIVE ANALYSIS,

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Transcription:

Chapter 1 Introduction Learning Objectives To understand the need to interface liquid chromatography and mass spectrometry. To understand the requirements of an interface between liquid chromatography and mass spectrometry and the performance of the combined system. The combination of chromatography and mass spectrometry (MS) is a subject that has attracted much interest over the last forty years or so. The combination of gas chromatography (GC) with mass spectrometry (GC MS) was first reported in 1958 and made available commercially in 1967. Since then, it has become increasingly utilized and is probably the most widely used hyphenated or tandem technique, as such combinations are often known. The acceptance of GC MS as a routine technique has in no small part been due to the fact that interfaces have been available for both packed and capillary columns which allow the vast majority of compounds amenable to separation by gas chromatography to be transferred efficiently to the mass spectrometer. Compounds amenable to analysis by GC need to be both volatile, at the temperatures used to achieve separation, and thermally stable, i.e. the same requirements needed to produce mass spectra from an analyte using either electron (EI) or chemical ionization (CI) (see Chapter 3). In simple terms, therefore, virtually all compounds that pass through a GC column can be ionized and the full analytical capabilities of the mass spectrometer utilized. This is not the case when high performance liquid chromatography (HPLC) and MS are considered where, due to the incompatibilities of the two techniques, they cannot be linked directly and an interface must be used, with its prime purpose being the removal of the chromatographic mobile phase. Unfortunately, no single

2 Liquid Chromatography Mass Spectrometry interface exists which possesses similar capabilities to those available for GC-MS, i.e. one that will allow mass spectra to be obtained from any compound that elutes from an HPLC column, and thus LC MS has not been guaranteed to provide the required analytical information. In addition, the complexity of the mass spectrometer has meant that the majority of chromatographers have not had direct access to the instrumentation and have had to rely on a service facility to provide results. They were therefore unable to react rapidly to the results of an analysis and consequently found it a particularly inconvenient detector to contemplate using. The different interfaces that have been made available commercially, and the applications to which they have been put, are the subjects of the following chapters. Before discussing these in detail, it is appropriate to consider a number of general questions, namely: (1) What are the advantages of linking HPLC with mass spectrometry? (2) What capabilities are required of such a combination? (3) What problems, if any, have to be addressed to allow the combination to function, and function effectively? 1.1 What are the Advantages of Linking High Performance Liquid Chromatography with Mass Spectrometry? In order to answer the first question, the limitations of the individual techniques must be considered and whether the combination will allow all or some of these to be overcome. Before doing this, however, the analytical tasks to which the combination will be applied must be defined. In many analyses, the compound(s) of interest are found as part of a complex mixture and the role of the chromatographic technique is to provide separation of the components of that mixture to allow their identification or quantitative determination. From a qualitative perspective, the main limitation of chromatography in isolation is its inability to provide an unequivocal identification of the components of a mixture even if they can be completely separated from each other. Identification is based on the comparison of the retention characteristics, simplistically the retention time, of an unknown with those of reference materials determined under identical experimental conditions. There are, however, so many compounds in existence that even if the retention characteristics of an unknown and a reference material are, within the limits of experimental error, identical, the analyst cannot say with absolute certainty that the two compounds are the same. Despite a range of chromatographic conditions being available to the analyst, it is not always possible to effect complete separation of all of the components of a mixture and this may prevent the precise and accurate quantitative determination of the analyte(s) of interest.

Introduction 3 The power of mass spectrometry lies in the fact that the mass spectra of many compounds are sufficiently specific to allow their identification with a high degree of confidence, if not with complete certainty. If the analyte of interest is encountered as part of a mixture, however, the mass spectrum obtained will contain ions from all of the compounds present and, particularly if the analyte of interest is a minor component of that mixture, identification with any degree of certainty is made much more difficult, if not impossible. The combination of the separation capability of chromatography to allow pure compounds to be introduced into the mass spectrometer with the identification capability of the mass spectrometer is clearly therefore advantageous, particularly as many compounds with similar or identical retention characteristics have quite different mass spectra and can therefore be differentiated. This extra specificity allows quantitation to be carried out which, with chromatography alone, would not be possible. The combination of HPLC with mass spectrometry therefore allows more definitive identification and the quantitative determination of compounds that are not fully resolved chromatographically. 1.2 What Capabilities are Required of the Combination? Ideally, the capabilities of both instruments should be unaffected by their being linked. These include the following (adapted from Snyder and Kirkland [1]): The interface should cause no reduction in chromatographic performance. This is particularly important for the analysis of complex multi-component mixtures (although the specificity of the mass spectrometer may, in certain circumstances, compensate for some loss of performance see Chapter 3). No uncontrolled chemicalmodification of the analyte should occur during its passage through the interface or during its introduction into the mass spectrometer. There should be high sample transfer to the mass spectrometer or, if this takes place in the interface, ionization efficiency. This is of particular importance when trace-level components are of interest or when polar and/or labile analytes are involved. The interface should give low chemical background, thus minimizing possible interference with the analytes. The interface should be reliable and easy to use. The interface should be simple and inexpensive (a subjective assessment). Operation of the interface should be compatible with all chromatographic conditions which are likely to be encountered, including flow rates from around 20 nl min 1 to around 2 ml min 1, solvent systems from 100% organic phase to 100% aqueous phase, gradient elution, which is of particular importance in

4 Liquid Chromatography Mass Spectrometry the biological field in which mixtures covering a wide range of polarities are often encountered, and buffers, both volatile and involatile. Operation of the interface should not compromise the vacuum requirements of the mass spectrometer and should allow all capabilities of the mass spectrometer to be utilized, i.e. ionization modes, high resolution, etc. The mass spectrum produced should provide unambiguous molecular weight information from the wide range of compounds amenable to analysis by HPLC, including biomolecules with molecular weights in excess of 1000 Da. The study of these types of molecule by mass spectrometry may be subject to limitations associated with their ionization and detection and the mass range of the instrument being used. The mass spectrometer should provide structural information that should be reproducible, interpretable and amenable to library matching. Ideally, an electron ionization (EI) (see Chapter 3) spectrum should be generated. An interface that fulfils both this requirement and/or the production of molecular weight information, immediately lends itself to use as a more convenient alternative to the conventional solid-sample insertion probe of the mass spectrometer and some of the interfaces which have been developed have been used in this way. The interface should provide quantitative information with a reproducibility better than 10% with low limits of detection and have a linear response over a wide range of sample sizes (low picograms to µg). 1.3 What Problems, if Any, Have to be Addressed to Allow the LC MS Combination to Function, and Function Effectively? It is possible to carry out a chromatographic separation, collect all, or selected, fractions and then, after removal of the majority of the volatile solvent, transfer the analyte to the mass spectrometer by using the conventional inlet (probe) for solid analytes. The direct coupling of the two techniques is advantageous in many respects, including the speed of analysis, the convenience, particularly for the analysis of multi-component mixtures, the reduced possibility of sample loss, the ability to carry out accurate quantitation using isotopically labelled internal standards, and the ability to carry out certain tasks, such as the evaluation of peak purity, which would not otherwise be possible. There are two major incompatibilities between HPLC and MS. The first is that the HPLC mobile phase is a liquid, often containing a significant proportion of water, which is pumped through the stationary phase (column) at a flow rate of typically 1 ml min 1, while the mass spectrometer operates at a pressure of around 10 6 torr (1.333 22 10 4 Pa). It is therefore not possible simply to pump the eluate from an HPLC column directly into the source of a mass

Introduction 5 spectrometer and an important function of any interface is the removal of all, or a significant portion, of the mobile phase. The second is that the majority of analytes that are likely to be separated by HPLC are relatively involatile and/or thermally labile and therefore not amenable to ionization by using either EI or CI. Alternative ionization methods have therefore to be developed. In the following chapters, the basic principles of HPLC and MS, in as far as they relate to the LC MS combination, will be discussed and seven of the most important types of interface which have been made available commercially will be considered. Particular attention will be paid to the electrospray and atmosphericpressure chemical ionization interfaces as these are the ones most widely used today. The use of LC MS for identification and quantitation will be described and appropriate applications will be discussed. Summary In this chapter, the reader has been introduced to the analytical advantages to be gained by linking high performance liquid chromatography to mass spectrometry with particular regard to the limitations of the two techniques when they are used independently. The characteristics of an ideal liquid chromatography mass spectrometry interface have been discussed, with emphasis having been placed upon the major incompatibilities of the two component techniques that need to be overcome to allow the combination to function effectively. References 1. Snyder, L. R. and Kirkland, J. J., Introduction to Modern Liquid Chromatography, Wiley, New York, 1974.