BREAKTHROUGH OF THE MINI-CYCLOTRON MASS SPECTROMETER FOR 14C ANALYSIS

Similar documents
Accelerator Mass Spectroscopy

HIRFL STATUS AND HIRFL-CSR PROJECT IN LANZHOU

Basic Principle of Cyclotron

Investigation on the spiral inflector and central region of the IsoDAR test-bench cyclotron

Direct-Current Accelerator

SUPERCONDUCTING HEAVY ION CYCLOTRON

GANIL STATUS REPORT. B. Jacquot, F. Chautard, A.Savalle, & Ganil Staff GANIL-DSM/CEA,IN2P3/CNRS, BP 55027, Caen Cedex, France.

Extraction from cyclotrons. P. Heikkinen

IBA C400 Cyclotron Project for hadron therapy

CYCLOTRON DEVELOPMENT PROGRAM AT JYVÄSKYLÄ

3.5. Accelerator Mass Spectroscopy -AMS -

CEE 772 Lecture #27 12/10/2014. CEE 772: Instrumental Methods in Environmental Analysis

POSITRON EMISSION ISOTOPE PRODUCTION CYCLOTRON AT DLNP JINR (STATUS REPORT)

CEE 772: Instrumental Methods in Environmental Analysis

Section 4 : Accelerators

This is the total charge on an ion divided by the elementary charge (e).

Accelerators Ideal Case

Design of a Sector Magnet for High Temperature Superconducting Injector Cyclotron

C - AMS. Introduction Identification of 14 C. Remarks for users

Magnetic field simulation in the central region of the VINCY Cyclotron

Developments of the RCNP cyclotron cascade

The Cyclotron I. 1. Motion of the charges occurs in two semicircular containers, D 1. and D 2

A CYCLOTRON TEST SITE FOR NEUTRINO EXPERIMENTS

ICP-MS. High Resolution ICP-MS.

Introduction to Longitudinal Beam Dynamics

DEVELOPMENT OF FFAG AT KYUSYU UNIVERSITY

Longitudinal dynamics Yannis PAPAPHILIPPOU CERN

Fluctuation Suppression during the ECH Induced Potential Formation in the Tandem Mirror GAMMA 10

OPERATION STATUS OF HIGH INTENSITY ION BEAMS AT GANIL

E. V. Samsonov, B. N. Gikal, O. N. Borisov, I. A. Ivanenko NUMERICAL SIMULATION OF ION ACCELERATION AND EXTRACTION IN CYCLOTRON DC-110

CHAPTER D4 ORTHOGONAL TIME OF FLIGHT OPTICS

AN ION SOURCE FOR THE HVEE 14C ISOTOPE RATIO MASS SPECTROMETER FOR BIOMEDICAL APPLICATIONS

corresponding l Nuclear Physics Laboratory and Quaternary Isotope Laboratory University of Washington, Seattle, Washington INTRODUCTION

DUBNA CYCLOTRONS STATUS AND PLANS

FIRST RADIOCARBON MEASUREMENTS AT BINP AMS

EQUIPMENT Beta spectrometer, vacuum pump, Cs-137 source, Geiger-Muller (G-M) tube, scalar

RECOMMENDATIONS FOR NOMENCLATURE OF MASS SPECTROMETRY

PARTICLE ACCELERATORS

Lectures on accelerator physics

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

Modern Physics Laboratory Beta Spectroscopy Experiment

Mass Spectrometry. What is Mass Spectrometry?

ICPMS Doherty Lecture 1

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Accelerator Physics, BAU, First Semester, (Saed Dababneh).

Summary of lecture 1 and 2: Main ingredients in LHC success

From simulations to an operating cyclotron The story of the K130 cyclotron

Chopping High-Intensity Ion Beams at FRANZ

ICP-MS. plasma 17OO. High Resolution Multi-Collector ICP-MS.

Physics. Student Materials Advanced Higher. Tutorial Problems Electrical Phenomena HIGHER STILL. Spring 2000

The FAIR Accelerator Facility

Extraction by stripping in the INFN-LNS Superconducting Cyclotron:

EBSS: Hands-on Activity #8. Operation of an electromagnetic isotope separator (EMIS) Dan Stracener Jon Batchelder

Joint Institute for Nuclear Research. Flerov Laboratory of Nuclear Reactions. University Center LABORATORY WORK

Design and test of an Accelerator Driven Neutron Activator at the Joint Research Centre of the European Commission

COMMISSIONING OF THE COUPLED CYCLOTRON SYSTEM AT NSCL

3. Particle accelerators

Progress in April December 2007 Schedule in Jan. March 2008

Development of Long Pulse Neutral Beam Injector on JT-60U for JT-60SA

Insertion Devices Lecture 2 Wigglers and Undulators. Jim Clarke ASTeC Daresbury Laboratory

The accelerators at LNS - INFN and diagnostics aspects of the radioactive beams

Extrel Application Note

Beam Diagnostics Lecture 3. Measuring Complex Accelerator Parameters Uli Raich CERN AB-BI

R JUERG BEER, HANS OESCHGER, and MICHEL ANDREE Physikalisches Institut, Universitat Bern, CH-3012 BERN, Switzerland

DESIGN OF A WIEN FILTER AND MEASUREMENT OF LONGITUDINAL POLARIZATION OF BETA PARTICLES BY S. S. ABHYANKAR AND M. R. BHIDAY

Calibration of Particle Instruments in Space Physics

THE S2C2: FROM SOURCE TO EXTRACTION

Defining quality standards for the analysis of solid samples

DEVELOPMENT OF JINR FLNR HEAVY-ION ACCELERATOR COMPLEX IN THE NEXT 7 YEARS

ELECTRON COOLING EXPERIMENTS IN CSR*

STATUS REPORT ON SPIRAL1 F. Chautard October 2 nd, 2007

SRF GUN CHARACTERIZATION - PHASE SPACE AND DARK CURRENT MEASUREMENTS AT ELBE*

Multicusp Sources for Ion Beam Lithography Applications

Ion Implanter Cyclotron Apparatus System

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

ITEP HEAVY ION RFQ OUTPUT LINE UPGRADE FOR EXPERIMENTS OF REACTOR MATERIAL INVESTIGATION UNDER IRRADIATION*

RCNP cyclotron facility

has long-lived been used radioisotopes to detect by counting the accelerated ions. beams has been solved by combining

State the position of protons, neutrons and electrons in the atom

Ultratrace analysis of radionuclides by AMS

Preliminary Simulation of Beam Extraction for the 28 GHz ECR Ion Source

Electromagnetism Notes 1 Magnetic Fields

1.4 The Tools of the Trade!

Proposal to convert TLS Booster for hadron accelerator

Chapter 29 The Magnetic Field

J H SHEA*, T W CONLON, JAMES ASHER, and P M READ. in the dating of artifacts (Gove, 1978).

Medical Linac. Block diagram. Electron source. Bending magnet. Accelerating structure. Klystron or magnetron. Pulse modulator.

Modeling of an Extraction Lens System

L-35 Modern Physics-3 Nuclear Physics 29:006 FINAL EXAM. Structure of the nucleus. The atom and the nucleus. Nuclear Terminology

Development of New MicroStrip Gas Chambers for X-ray Applications

Physics 663. Particle Physics Phenomenology. April 9, Physics 663, lecture 2 1

SCENT 300 Project Status Review

Beam Diagnostics. Measuring Complex Accelerator Parameters Uli Raich CERN BE-BI

Physics 610. Adv Particle Physics. April 7, 2014

!"#$%$!&'()$"('*+,-')'+-$#..+/+,0)&,$%.1&&/$ LONGITUDINAL BEAM DYNAMICS

NSCL and Physics and Astronomy Department, Michigan State University Joint Institute for Nuclear Astrophysics

Particle physics experiments

β-spectroscopy Fig. 1: Experimental set-up for determining inductance from the resonant frequency of an oscillatory circuit.

In-Flight Fragment Separator and ISOL Cyclotron for RISP

Transcription:

BREAKTHROUGH OF THE MINI-CYCLOTRON MASS SPECTROMETER FOR 14C ANALYSIS MAOBAI CHEN, DEMING LI, SENLINXU, GUOSHENG CHEN, LIGONG SHEN, XIANGSHUN L U, WEIYU ZHONG, YUEXIANG ZHONG, ZONGKUN ZHONG and YINGJI ZHONG Shanghai Institute of Nuclear Research, Academia Sinica, P.O. Box 800204, Shanghai 201800 and T. D. Lee Physics Laboratory, Fudan University, Shanghai y, ngha1200433 China ABSTRACT. We present results of current measurements on the super-sensitive mini-cyclotron as an accelerator mass spectrometer, successfully developed at Shanghai Institute of Nuclear Research (SINR). We describe new ideas and unique techniques adopted for increasing the transmission efficiency in the injection, acceleration and extraction region, for eliminating various backgrounds and for improving the precision of 14C analysis, which have led to the breakthrough of our Shanghai Mini-Cyclotron Accelerator Mass Spectrometry project. We also discuss further development of the prototype facility. INTRODUCTION A cyclotron was first used as an accelerator mass spectrometer (AMS) by L. W. Alvarez in 1939 in an experiment that demonstrated the stability of 3He (Alvarez 1981). In 1977, R. A. Muller published an article in which he suggested that a cyclotron could be used as a mass spectrometer to detect (Muller 1977). Following 14C the initiative of the Berkeley group (Welch et al. 1987), we began the Shanghai Mini-Cyc1 otron Accelerator Mass Spectrometry (SMCAMS) project in late 1985. The first phase of the project has now been completed. Using resonance analysis, the cyclotron AMS can sensitively discriminate among the background particles even with the mass difference resulting only from mass defect. Thus, there is less tail phenomenon on a mass spectrum. A cyclotron should be the most suitable for a super-sensitive mass spectrometer, but it is not, for the following reasons: 1. Because stable negative ions, such as N-, do not exist for isobars of many radioactive nuclei to be analyzed, the required resolution for AMS is greatly decreased if negative ions of a sample particle are analyzed. Cyclotrons do not usually y can accelera to negative heavy ions, whereas tandems do. 2. In dating applications, one must measure the ratio of the radioactive isotope to its corresponding stable isotope, such as 14C/13C by y alternately y accelerating both negative ions. It is easier for a tandem AMS to change one electric parameter sequentially, or even to measure all three isotopes simultaneously (Purser 1992). It is more difficult for a large cyclotron to change many Y electric parameters as well as magnetic field sequentially. 3. The beam intensity in all small cyclotrons developed in the 1950s (Clark 1984) and in the 1980s (Bertsche et a1. 1990) was too low to count rare isotopes. Thus, tandem AMS dating has overtaken the cyclotron AMS technique during the past decade. As a super-sensitive mass spectrometer, the mini-cyclotron has the following advantages common to both tandem and cyclotron AMS: 1. It is capable of accelerating negative ions, which can be extracted directly for measurement without the need for stripping. Positive ions can also be analyzed. 2. It retains the function of resonance analysis of the cyclotron AMS. Alternate acceleration can be undertaken without changing the magnetic field, because the relativistic effect is negligible at very low energy (50 key). 3. Most important, it can be set up at almost any laboratory for 14C analysis, because of its low operating costs, small size, low energy, low magnetic field and low power consumption (12 kw). Proceedings of the 15th International 14C Conference, edited by G. T. Coo/c D. D. Harkness, B. F. Miller and E. M. Scott. RADIOCARBON, Vol. 37, No. 2,1995, P. 675-681 675

676 M. Chen et al. KEY TO THE BREAKTHROUGH A mini-cyclotron AMS for 14C analysis should not only efficiently deliver the heavy negative 14C' ions, but it should also eliminate all backgrounds, especially 13CH' ions, the ion closest to 14C. The mass resolution needed for discriminating 14C- from 13CH' is ca. 1800. According to the resolution formula of a cyclotron R = M/EM = 360 nh/lq = 2 nh (1) where iq =180 is the defined maximum amount needed for shifting the radio frequency (RF) phase of 13CH' ions to the deceleration phase, n is the maximum acceleration turn number experienced by the 13CH' ions with OQ =180, and h is the harmonic number, i. e., the ratio of RF to 14C' ion revolution frequency. High resolution can be achieved by increasing the product, nh. However, the increase of either n or h would require strict mechanical constraints and great electrical stability, as well as precision of the isochronous magnetic field on a mini-cyclotron itself. Hence, this would jeopardize the particle acceptance of the mini-cyclotron. A large turn number, n, would 1) hamper the operation of negative heavy 14C' ions with very low energy; 2) enlarge the diameter of the mini-cyclotron magnet; or 3) tighten the turn spacing so as to damage the injection and extraction of particles. We were forced to meet the high-resolution requirements by increasing the harmonic number, h. Although a high harmonic number would greatly enhance some effects, such as the energy spread of the beam, RF phase divergence and convergence of particles and the coupling effect between longitudinal and transversal motion, it would result in deteriorated beam quality and density. Thus, it is unreasonable for cyclotrons to operate with high harmonics, primarily because the sinusoidal wave (sine wave) accelerating voltage is used in all existing cyclotrons. Attempts were made in the 1950s to build small cyclotrons as mass spectrometers (Clark 1984). However, all failed to achieve abundance sensitivity of higher than 10'9 due to low beam intensity (1015 A). This is the case for the modern small Cyclotrino (10'9 A) at Berkeley (Bertsche et al. 1990). To obtain 14C counts from the SMCAMS, we focused on increasing the 12C' beam intensity by improving the transmission efficiency in the acceleration region as well as the injection and extraction efficiency. To overcome the effect of the high-harmonic operation on the transmission efficiency in the acceleration region of a mini-cyclotron, we used a triangular-wave accelerating voltage instead of the usual sine-wave accelerating voltage (Chen, Li and Gao 1989). Calculations indicated (Lu 1992) that the transmission efficiency using a triangular-wave voltage would increase by ca. 50 times compared with sine-wave voltage. The results of beam tuning were also satisfactory. To fully use the powerful function of the triangular-wave voltage and to minimize the energy spread of the beam, the RF phase of particles should be located in the linear area of the real triangular wave voltage when crossing the accelerating gap. This is because non-linearity exists on both ends of the real shape of the triangular wave voltage. Nevertheless, the force of the electric focusing field (phase focusing) approaches zero near the center of the linear area of the triangular wave voltage, which makes the ion motion unstable and renders insignificant the adoption of the triangular-wave voltage to increase beam intensity. To keep ion motion stable, we must rely on magnetic focusing by using a non-uniform magnet. We believe a uniform magnet is inappropriate for AMS with a cyclotron, where the analyzed particles circle inside the magnet for many turns rather than for <1 turn, as is the case in conventional mass spectrometry. Thus, we designed a non-uniform magnet with high flutter.

41 ini-cyclotron AMS 677 The nickel-coated yoke constitutes the vacuum chamber of the mini-cyclotron, design the first time has been such a used. The isochronous magnetic field is adjusted by correcting the tors without shape of the using secusual trim coils. After we successfully built a ramp generator of V (peak to peak) =1 kv and shaped magnetic the isochr field, onous the beam tuning indicated a transmission efficiency in the acceleration >20% under region harmonic of h=16 operation. Such a transmission efficiency is affected b which man include fact linearity of the real triangular-wave voltage, ' Y Y ors, isochronous deviation magnetic of the field, shaped vacuum and aperture of the accelerating (dee) electrodes. For mini-cyclotron AMS, one should choose external injection for: 1 rom tl chan in 2 ) P reduci P Y greatly g g samples; ng memory effect; 3) adopting a high-yield Cs sputter negative ion applying sour ce, and 4) an emitting voltage (20 kv) that i is much higher than the accelerating voltage (500 V ). also important It is that the single-particle detector-a dynode and microchannel plate (Friedman 1988; Zhang et al. et a1.1991)-which can count the particle number but cannot distinguish should the article be located outside the mini-cyclotron to avoid the strong X-ray interference induced inevitably by the beam hitting inside the vacuum chamber of the mini-cyclotron. Thus more we attention shoul d pay to improving the injection and extraction efficiency. As for axial injection in a cyclotron, it is usually accomplished by passing articles or through a a spiral mir inflector. We designed a air of spherical electrostatic injection deflectors-vertical injection deflector and horizontal injection deflector (Fig. 1)-and obtained a total injection ciency of effica. 60%. - Because the energy gain per turn in SMCAMS is small (Chen, Gao and Li 1989 improving the next goal injection for and )' J ex traction efficiency 1s to obtain a turn spacing wide enough to clear the Vacuum Chamber Clearing Deflector CsSputter Ion Source Micro. Channel Plate Extraction Deflector Measurement Deflector 1 "T" Shaped Dee Electrode Beam Probe Auxiliary Electrode f'z',97/f] Coil Fig. 1. Schematic diagram of the SMCAMS facility Yoke LID Sector RF Generator

678 M. Chen et al. horizontal injection deflector in the first turn and to enter the horizontal extraction deflector at the last turn. The magnetic perturbation method often used in large cyclotrons to obtain the desired turn spacing is not applicable to the mini-cyclotron. In our mini-cyclotron with a non-uniform magnet of high flutter, we use accelerating (dee) electrodes with zero angle for convenience of assembly. These electrodes constitute differential electrodes with a sandwich structure, equivalent to two adjacent dee-dummy dee structures in series (Chen, Xu and Li 1990). The feature of such an electrode arrangement is that the effective dee voltage experienced by particles crossing the electrode gap increases as the harmonic number, h, increases, and can be adjusted by changing the geometric parameters, D (gap width), T (dee width) and H (dee aperture) of the structure rather than by merely adjusting the dee voltage. To meet the high-energy gain demanded for injection and extraction, and to keep the lowest energy gain within working radii, we adopted a pair of auxiliary electrodes and asymmetric width varied electrodes with wedge shape. This is based on the above-mentioned feature of the differential electrode and the recently explored phase divergence and convergence phenomenon under high harmonic operation (Chen, Xu and Li 1990) to obtain the necessary turn spacing of 6 mm. This new type of electrode is simple and practical. We have begun to take steps toward eliminating interference of backgrounds, particularly 13CH and X-rays by: Analyzing negative ions of 14C to remove the isobar 14N' Defining iq =180 or R = 2nh to determine the necessary turn numbers to ensure eliminating 13CH- Establishing a prohibitive zone of 6 cm wide. Theoretically, 13CH' with iq =180 will start to decelerate inward before it approaches this zone, whereas 14C' particles will continue to accelerate outward for ca. 30 additional turns to reach the extraction region. If there are any unwanted particles in this zone, their energy and direction of motion would probably be unsuitable for the extraction condition of the deflector. Using the extraction deflector as a final electrostatic analyzer Placing the single particle detector outside the mini-cyclotron, and protecting it from strong X-rays by lead shielding Adding two additional deflectors during alternate acceleration: a) the measuring deflector, to which a pulsed rectangular voltage is applied while detecting 14C' to deflect the ions onto the dynode of the single particle detector. This voltage will be suppressed while measuring 12C' or 13C-, as they well strike an adjacent Faraday cup, b the clearing deflector, to which a pulsed voltage is applied at the moment when the alternate 12C' or 13C' acceleration is turned into 14C acceleration. In our mini-cyclotron, all particles emitted from the ion source are simultaneously injected into the vacuum chamber without using an analyzing magnet prior to the cyclotron, because most of the unwanted particles, except 13CH' ions, can easily be eliminated by powerful resonance analysis. However, the lack of the pre-analyzing magnet makes measuring 12C' and 13C' difficult. In dating, one must measure sequentially the ratio of the detected radioactive isotope being analyzed to its corresponding stable isotope, such as 14C/12C and 13C/12C. Thus, contrary to conventional cyclotrons, where only one type of ion can be accelerated, the 12C, 13C- and 14C' ions must be accelerated alternately in a mini-cyclotron AMS. It is a complex task for a mini-cyclotron, even though it reaches a low final energy and requires no adjustment to the magnetic field. Because the mass difference between 14C and 12C is ca. 15% and the magnetic field is fixed, most electric parameters must be sequentially changed for ca. 15%, according to the orbit similarity theory.

Mini-Cyclotron AMS 679 The transmission efficiency of different particles (12C-, 13C- and 14C') from the exit of the ion source down to the detector must always be calibrated against a standard or known sample, which we can also use to monitor and correct for any change of the transmission efficiency. A blank sample is also used to monitor the background level of the detector. A feature critical to precision of analysis is the flat-top transmission characteristic of the mini-cyclotron AMS in the infection, acceleration and extraction region. Even if there is an inevitable minor fluctuation of critical parameters, the transmission efficiency must not change or induce fractionation. RESULTS Figure 2A shows the 14C' and 13CH' frequency response (counts vs. frequency) for a carbon sample made from sugar. It shows that the 14C counting is ca. 100 c m under ca. 15,uA of 12C from ion source, and the ratio of peak to valley on the curve reaches 3. Figure 2B is the same curve for a blank sample. No counts occur at the frequency position corresponding to the peak of 14C' counts, which implies that the adjacent 13CH' ions have been thoroughly suppressed. Further, background counts for a blank sample show a detection limit of 10'15. Figure 3A, B shows the frequency response for 12CH2-,13CH- and for 12CH', 13C. It is apparent from Figure 3 that the resolution of the SMCAMS has approached ca. 3000, which is much higher than needed (ca. 1800) for distinguishing 14C from 13CH. These measurements indicate that the SMCAMS facility is now able to perform AMS. CONCLUSION The first phase of the SMCAMS project established our facility and obtained 14C counts to demonstrate our innovation. For practical applications, we must build a microcomputer-controlled system for alternately accelerating 12C-,13C- and 14C-, and equip the vertical Cs ion source with a fiber-opticcontrolled multi-sample device for sequentially changing samples. We must also improve the performance of the prototype, especially the injection and extraction efficiencies, and explore methods of alternate acceleration and 14C analysis on a mini-cyclotron. 500 1 3C H A 200, t 13CH B 140 U 100 50 0 0 4.1275 4.1280 4.1285 4.1290 4.1295 4.1300 4.1305 4.1275 4.1280 4.1285 4.1290 4.1295 4.1300 RF frequency (MHz) RF frequency (MHz) Fig. 2. A. '4C and 13CH frequency response curve for a carbon sample made from sugar. B. '4C and 13CH frequency response curve for a blank sample. 140

680 M. Chen et al. A 13CH 6 13c 12CHZ 0 T'1 4.1241 4.1254 4.1267 Frequency(MHz) 4.1280 Fig. 3. Frequency response curves for blank samples: A.12CH2 and 13CH; B.12CH and 13C ' 00 4.4435 4.4445 4.4455 4,4465 4,4475 Frequency(MHz) The computer system has now been completed and the alternate acceleration is being g tested. W e have just finished designing the multi-sample le device (gof p for our vertical ion source and expect to test this device in late 1995. We have also refined our beam tuning and remeasured the whole ion s spectram of 12C-, 13C-,12CH-, 14C-,13CH` and 12CH ` 2 Fi. 3). The ratio peak to valley on the 14C and 13 CH frequency response curve has now increased to 4, as shown in Figure 4. This illustrates the improvement of the resolution; the flatter shape of the peak is better for 14C-counting precision. We have learned the causes for beam loss in the central region of the mini-cyclotron, and are confident of improving transmission efficiency by refining the central region and increment of the dee aperture as well as the vacuum. We will reinforce the X-ray shielding to further improve counting operation. 200 25 0 ti 4.1280 4.1290 4.1300 Frequency (MHz) Fig. 4. Current-measured 14C and 13CH frequency response curve for a carbon sample made from sugar

Mini-Cyclotron AMS 681 ACKNOWLEDGMENTS This research was supported by the National Natural Science Foundation of China and Academia Sinica. We are also indebted to Prof. Fujia Yang for his strong support and encouragement. REFERENCES Alvarez, L. W. 1981 The early days of accelerator mass spectrometry. In Kutschera, W., ed., Proceedings of the Symposium on Accelerator Mass Spectrometry. ANL/PHY 81-1, Springfield, National Technical Information Service: 1-15. Bertsche, K. J., Karadi, G. A., Muller, R. A. and Paulson, G. C. 1990 Detection of radiocarbon in the cyclotrino. In Yiou, F. and Raisbeck, G. M., eds., Proceedings of the 5th International Conference on Accelerator Mass Spectrometry. Nuclear Instruments and Methods in Physics Research B52: 398-402. Chen, M. B., Gao, W. Z. and Li, D. M. 1989 Design criteria on a mini cyclotron as a mass spectrometer for dating. Nuclear Instrument and Methods in Physics Research A278: 402-408. Chen, M. B., Li, D. M. and Gao, W. Z. 1989 Adopting a non-sinusoidal wave dee voltage in minicyclotron as mass spectrometers for dating. Nuclear Instruments and Methods in Physics Research A278: 409-416. Chen, M. B., Xu, S.L. and Li, D. M. 1990 Determination of the shape of the dee electrodes in the SINR minicyclotron used as AMS for 14C dating. Nuclear Instrument and Methods in Physics Research A297: 47-59. Clark, D. 1984 Cyclotrons as mass spectrometers. In Marti, F., ed., Proceedings of the 10th International Conference on Cyclotrons. New York, The Institute of Electrical and Electronics Engineers: 534-539. Friedman, P. G., Bertsche, K. J., Michel, M. C., Morris, D. E., Muller, R. A. and Tans, P. P. 1988 Low background-rate detector for 40 kev ions using a conversion dynode and a microchannel-plate electron multiplier to reject low-energy ions, electrons, and photons. Review of Scientific Instruments 59(1): 98-111. Lu, X. S. (ms.) 1992 Study of Effects of Non-Ideal Factors on the Minicyclotron as AMS. Master's dissertation. Shanghai Institute of Nuclear Research: 105 p. Muller, R. A. 1977 Radioisotope dating with a cyclotron. Science 196: 489-494. Purser, K. H. 1992 A high throughput 14C accelerator mass spectrometer. In Long, A. and Kra, R. S., eds., Proceedings of the 14th International Radiocarbon Conference. Radiocarbon 34(3): 458-467. Welch, J. J., Bertsche, K. J., Friedman, P. G., Morris. D. E., Muller, R. A. and Tans, P. P. 1987 A low energy cyclotron for radiocarbon dating. Nuclear Instruments and Methods in Physics Research B18: 202-214. Zhang, Y. G., Wei, Y. G.,Wang, Q. Y. and Qian,W. G. 1991 A position-sensitive microchannel-plate detector for 27 kev ions. Nuclear Instruments and Methods in Physics Research A302: 76-82.