High throughput analysis of polymer stabilizers with the Agilent 6420 Triple

Similar documents
Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Chemistry Instrumental Analysis Lecture 37. Chem 4631

materials analysis Solutions for Your Analytical Business Markets and Applications Programs

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Application Note FTMS-56 Reproducibility of Crude Oil Characterization by Flow Injection APPI-FT-ICR Mass Spectrometry

TANDEM MASS SPECTROSCOPY

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Test method for the determination of NDMA and NDEA by LC-MS/MS in Sartan containing film coated tablets

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Supporting Information

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS

Mass Spectrometry in MCAL

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Identification and analysis of polymer additives using packed-column supercritical fluid chromatography with APCI mass spectrometric detection

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Agilent ESI and APCI sources: for polar to non-polar compounds

Analysis of Polymer Additives and Impurities by Liquid Chromatography/Mass Spectrometry and Capillary Electrophoresis/Mass Spectrometry

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

Application. Introduction. Authors. Abstract. Hydrocarbon Processing

Translational Biomarker Core

WADA Technical Document TD2003IDCR

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Application Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract

Accurate Mass Analysis of Hydraulic Fracturing Waters

770-9P. Sensitivity and Selectivity - A Case Study of LC/MS Enantioselective Resolution of Bupivacaine Using Vancomycin as a Chiral Stationary Phase

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Application Note. Edgar Naegele. Abstract

The Theory of HPLC. Quantitative and Qualitative HPLC

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

Application Note. Abstract. Authors. Environmental

CHEM 429 / 529 Chemical Separation Techniques

Chromatography. Gas Chromatography

ENVIRONMENTAL analysis

Multi-residue analysis of pesticides by GC-HRMS

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

[application note] INTRODUCTION EXPERIMENTAL. Specimens. Extraction

DISCLAIMER: This method:

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

Introduction to Pharmaceutical Chemical Analysis

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Uncontrolled Copy. SOP 109 Ethylene Glycol Screen by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay...

Analysis of Polar Metabolites using Mass Spectrometry

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Optimization of the sample preparation and extraction methodology

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Chemistry Instrumental Analysis Lecture 31. Chem 4631

Training Courses. Chromatography training from the Crawford Scientific experts

M M e M M H M M H. Ion Sources

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Introduction to the Q Trap LC/MS/MS System

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Highly sensitive and rapid analysis of synthetic dyes in sea food by LC/MS/MS

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

Hplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved In Method Development And Validation

Hplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved In Method Development And Validation

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Guide to Peptide Quantitation. Agilent clinical research

Fast Screening and Quantitation of Perfluorinated Sources from Textiles using Chemical Ionization GC-MS

Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry

Determination of Volatile Substances Proof of Food Adulteration

Low-level Determination of 4-Hydrazino Benzoic Acid in Drug Substance by High Performance Liquid Chromatography/Mass Spectrometry

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Analysis of Polyphenols in Saffron Petal Extracts with UHPLC/UV/MS

Computer-assisted analysis of complex natural product extracts

GPC/MS. Analysis of PET

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Analysis of Cannabinoids and Amphetamines in Serum by RRLC/Triple Quadrupole Mass Spectrometry Using a Multimode Ion Source. Application.

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Polymer analysis by GPC-SEC. Technical Note. Introduction

Transcription:

materials analysis High throughput analysis of polymer stabilizers with the Agilent 6420 Triple Quadrupole LC/MS Solutions for Your Analytical Business Markets and Applications Programs Authors Susanne Beißmann, Michael Reisinger, Christian W. Klampfl, Wolfgang Buchberger Johannes Kepler University Linz, Austria. Andreas Reimann, Agilent Technologies. Abstract The capability of highly sensitive and rapid flow injection coupled to multiple reaction monitoring mass spectrometry for comprehensive analysis of several polymer stabilizers, belonging to quite different chemical classes, is demonstrated. A critical factor is the choice of the ionization mode, as no separation of the different stabilizers was performed prior to MS-detection. Differences between several ionization techniques regarding matrix effects are pointed out. Atmospheric pressure chemical ionization was found to be the most suitable ionization technique, with hardly any matrix effects observed. The developed method has a linear dynamic range over two to three orders of magnitude, with correlation coefficients better than 0.99 for all analytes. The method allowed quantitation down to 0.0001-0.04 wt% in plastic materials depending on the stabilizer. The suitability of the optimized method for analysis of real samples was proven by the comparison of results with an established chromatographic approach. INTRODUCTION The importance of plastic materials has increased over the years and nowadays they are deployed in nearly every aspect of our lives. Without proper stabilization, polymers are susceptible to degradation caused by reactions with oxygen and/or UV-light, which lead to undesirable changes in the properties of these materials. To minimize decomposition, different kinds of stabilizers are added to the polymer, whereby its protection depends on the presence of these additives in sufficient concentrations. Therefore, the identification and quantitation of stabilizers are of major importance in order to evaluate suitability of materials of unknown origin for certain application areas, to clarify reasons for failure of materials or for comparison of materials from different suppliers. Since the complexity of additives and additive formulations has increased over the last decade and the amount added is often small (and can even be further decreased due to degradation), both identification and quantitation in the polymer can be very challenging. As stabilizers belong to quite different chemical classes, methods allowing comprehensive analysis of the large variety of commercially used stabilizers are desirable.

Nowadays there are various different analytical tools for analyzing polymer additives. Thereby two approaches can be distinguished, analysis of the plastic product as it is and analysis after dissolution of the polymer and subsequent extraction of the stabilizers. If reliable quantitative results are required, the latter approach is the more favorable one. Focusing on the chromatographic separation of such extracts, pyrolysis GC [1], supercritical fluid chromatography (SFC) [2] and high performance liquid chromatography (HPLC) [3-6] are most widely employed. Whereas pyrolysis GC only provides information on additive fragments, HPLC is restrictive when it comes to the analysis of large, lipophilic hindered amine light stabilizers (HALS), which may show irreversible adsorption to silica-based stationary phases. Besides, another disadvantage of chromatographic methods is the fact that they may be quite timeconsuming. Flow injection in combination with mass spectrometry (FI-MS) offers the advantage of being a much faster, simpler technique than conventional quantitative methods, but it is known that lack of chromatographic separation between analytes and matrix may lead to suppression or enhancement of the ionization process, especially when electrospray ionization (ESI) is employed. Atmospheric pressure chemical ionization (APCI) and atmospheric pressure photo ionization (APPI) are reported to be less prone to matrix effects, so their application is becoming more and more popular [7, 8]. The present work is a detailed study on the potential of high-throughput quantitation of polymer additives using FI multiple reaction monitoring-ms (MRM-MS) without prior chromatographic separation. Different ionization methods were compared to determine their suitability for the analysis of additives in real polymer samples. The main purpose was to develop a highly sensitive, accurate and rapid method for simultaneous identification and quantitation of the most commonly used stabilizers. EXPERIMENTAL Instrumentation FI/MRM-MS measurements were performed on an Agilent 6420 Triple Quadrupole MS System (Agilent Technologies, Waldbronn, Germany) equipped with ESI, APPI and APCI sources. A thermostated autosampler maintained at 30 C was used for sample injection. Injection volume was 5 μl throughout this work, but larger volumes can be used for samples with lower analyte concentrations. A binary pump (Agilent 1260) with a vacuum degasser was used for the delivery of a continuous carrier stream. The carrier stream consisted of a mixture of methanol / 0.025 M aqueous ammonium formate (95/5) for ESI and APCI and methanol / acetone for APPI. The flow rate was set to 0.6 ml min-1 with an acquisition time of 1 min. Other conditions for the QqQ MS instrument are shown in Table 1. ESI APCI APPI Nebulizer gas pressure / psi 35 50 50 Drying gas flow rate / L min-1 10 7 7 Drying gas temperature / C 325 325 325 Capillary voltage / V 4000 4500 4500 Vaporizer temperature / C - 350 350 Corona needle current / na - - 10000 Table 1: QqQ MS instrument parameters 2

Materials The following polymer additives (technical grade) were obtained from various commercial sources: Antioxidants: Cyanox 1790, Irganox 1330, Irganox 1076, Irganox 1010, Irganox 3114, Sumilizer GA 80, Naugard 445; hydroperoxide decomposers: Irganox PS 800, Irgafos 168; UV-absorbers: Uvinul 3040, Tinuvin 326, Tinuvin 234, Tinuvin 328, Chimassorb 81; metal deactivators: Irganox MD 1024, Naugard XL-1; hindered amine light stabilizers: Chimassorb 944, Cyasorb UV- 3529, Tinuvin 770, Uvinul 4050 H. Sample preparation: Internal standard and standard solutions: 1000 mg L-1 stock solutions were prepared by dissolving the pure stabilizers in toluene (except for Irganox MD 1024 which was dissolved in methanol). For calibration and determination of linearity and detection limits, standards were diluted from 10 mg L-1 down to the 0.01 mg L-1 level. Oligomeric HALS showed somewhat higher detection limits, so the calibration curves for these substances were obtained between 50 mg L-1 and 0.5 mg L-1. An internal standard (Cyanox 1790, 0.5 mg L-1) was added to each solution. Polymer material samples: Prior to analysis the various additives were extracted from the polyolefin material using a dissolution/precipitation procedure. About 20 mg of stabilized polymer sample was mixed with 50 µl of the internal standard solution (100 mg L-1 in toluene), as well as 10 µl of tributylphosphite (5000 mg L-1 in toluene) and 0.44 ml toluene. Afterwards, the solution was heated to 130 C for 1 h in a closed vial. After cooling, 0.5 ml methanol was added to the mixture and the sample was centrifuged. A defined volume of the supernatant fluid (100 µl) was diluted 10-fold with methanol. The resulting solution was used without any further treatment for FI/MRM-MS analysis. Results and discussion Qualitative analysis Several analytes were selected that include the most frequently used stabilizers from the different chemical classes. As a first step, their suitability for FI/MRM-MS was investigated using standard solutions of individual analytes at concentrations of about 10 mg L-1. Identification of the precursor ions was performed in the full scan mode (100 to 2200 m/z). Both positive and negative ionization were investigated. The positive mode proved to be better suited as it allowed the detection of all compounds and in most cases provided better sensitivity. For this reason, positive ionization was chosen for further investigation. In the next step, different ionization sources, namely ESI, APCI and APPI, were compared. ESI showed a somewhat better sensitivity for almost all analytes. Furthermore, ESI ionization offers the advantage of multiple charging, thus allowing detection of analytes with molecular masses exceeding the QqQ mass range (e.g. some high molecular oligomers of HALS). These findings make ESI the preferred ionization source for identification. The major focus of the present work was to develop a reliable and efficient method suitable for both identification and quantitation of the most frequently used stabilizers. Therefore, the evaluation of possible interferences like ionization suppression or enhancement was considered very important, in order to prevent biasing of quantitation measurements. 3

Investigation of matrix effects For studying matrix effects, two sets of calibration curves were constructed. One based on the measurements of the respective analyte in methanol, the other by standard addition to a polypropylene extract. Subsequently, the slopes of the obtained calibration curves were compared in order to evaluate the matrix influence. The results for three stabilizers are shown in Figure 1. ESI and APPI showed a high susceptibility towards matrix effects, visible by the significantly different slopes obtained for the calibration curves. In APCI-Detection, the slope of the two lines (with and without matrix) was identical for all analytes. This indicates that matrix effects are negligible for this ionization source, making it the most suitable for quantitative measurements. Figure 1: Identification of matrix effects by means of standard addition; dashed line: standard addition to a polypropylene extract; continuous line: standards in methanol; Bias%: (kmatrix kstandard) / kstandard, is the relative error between the slopes of the two standard addition curves. FI/MRM-MS for quantitative analysis Fragmentor voltage and collision energy were optimized to produce the highest response among products ions for MRM-monitoring. The Agilent optimizer software was used, which provides a means of automatically optimizing these crucial parameters, by ramping the fragmentor voltage and collision energy for each product ion. Subsequently, a list of the top four product ions with the highest intensities was generated. The fragmentor voltage was varied in the range of 50 to 400 Volts and the collision energy in the range of 5 to 80 Volts. The cell accelerating voltage was 7 Volts for all measurements. For each stabilizer, the higher response MRM was used for quantitation and the next highest level was monitored for confirmation purposes. The peak area ratio of the quantifier versus qualifier must be consistent and within a tolerance of +/- 20%. Chimassorb 944 showed only one transition with sufficient intensity, so no qualifier ion was used for this compound. The optimized MRM transitions are shown in Table 2. 4

MRM Fragmentor Voltage / V Collision energy / V Detection limit (LOD) / wt% Irganox 1010 1194.8 219.3 (163.2) 240 80 (80) 0.0006 Irganox 1076 548.5 107.1 (149.1) 130 34 (22) 0.0002 Irganox 1330 792.6 291.3 (203.2) 190 30 (70) 0.0002 Irganox 3114 801.6 219.2 (203.2) 165 26 (78) 0.0001 Sumilizer GA 80 758.5 163.1 (177.1) 165 54 (66) 0.0001 Naugard 445 406.3 196.1 (91.1) 210 42 (50) 0.0004 Uvinul 3040 229.1 151.0 (77.1) 120 18 (42) 0.0003 Tinuvin 326 316.1 57.1 (260.1) 130 26 (18) 0.0001 Tinuvin 234 448.2 370.2 (91.1) 175 18 (62) 0.0003 Tinuvin 328 532.2 43.2 (282.2) 185 38 (22) 0.0001 Chimassorb 81 327.2 137.0 (81.0) 140 30 (62) 0.0004 Irganox PS 800 515.4 143 (329.2) 140 14 (10) 0.0001 Irgafos 168 647.5 147.2 (235.1) 180 58 (58) 0.0001 Irgafos 168 oxidized 663.5 495.3 (327.1) 195 34 (62) 0.0002 Irganox MD 1024 553.4 181.2 (441.3) 180 30 (10) 0.0001 Naugard XL-1 714.5 159.1 (307.2) 135 54 (34) 0.0003 Cyasorb UV-3529 Oligomer 1 687.6 72.1 (560.4) 205 54 (34) 0.0247 Cyasorb UV-3529 Oligomer 2 921.7 154.1 (768.6) 205 46 (42) 0.0154 Tinuvin 770 481.4 58.2 (140.2) 175 38 (26) 0.0002 Uvinul 4050 451.4 58.2 (140.2) 180 46 (30) 0.0002 Chimassorb 944 994.0 140.0 325 66 0.0443 Cyanox 1790 (ISTD) 717.5 191.2 125 34 - Table 2: MRM Acquisition parameters and quantitation limits for each stabilizer (Qualifier ion settings in brackets); wt% related to the polymer Method validation Eight different levels of standard solutions, with concentrations ranging from 0.5 to 50 mg L-1 for the oligomeric HALS (Chimassorb 944 and Cyasorb UV-3529) and 0.01 to 10 mg L-1 for all the other analytes, were used to produce calibration curves. The results were obtained from the average of triplicate injections for all samples. Almost all analytes were found to be linear over the entire working range. For two analytes, namely Irganox 1010 and Cyasorb UV-3529, a quadratic regression showed a slightly better fit than a linear one. Correlation coefficients better than 0.99 were obtained for all analytes. In Figure 2 the calibration curves obtained for 6 analytes from different chemical classes are shown. Quantitation limits (LOQ) were calculated, with S/N better than 10/1 for the quantifier transitions and better than 3/1 for the qualifier transitions. The results are shown in Table 2. Recovery tests were performed to monitor the effect of the procedure, whereby recoveries were found to be in the range of +/- 10% for all analytes, except Irganox PS 800 which was in the range of 15%. Low variabilites were observed with standard deviations not exceeding 2.5 %. 5

Figure 2: Calibration curves obtained for six different stabilizers 6

Figure 3: Comparison of FI/MRM-MS analysis (R1) and the reference HPLC-UV analysis (R2); (a) Irgafos 168, (b) Irganox 1010, (c) Irganox 1330 FI/MRM-MS for quantitative analysis In order to study the applicability of the developed method for analysis of additives in real samples, five different polymer specimens, containing Irganox 1330 and Irgafos 168 (three of them also containing Irganox 1010) were selected. Stabilizers were extracted three times from each matrix as described in the experimental section and analysis of the extracts was performed by FI/MRM-MS and also by a validated HPLC-UV method for comparison purposes. The results were plotted to view possible discrepancies between the methods. As can be seen in Figure 3, the two methods showed very good correlation and differences were less than 7.5% (dashed line) for all measurements. These results prove that the newly developed method has the same relative accuracy as the well-established HPLC-UV method. 7

CONCLUSION In the work presented in this paper, applicability of FI, without prior chromatography, hyphenated to highly sensitive MRM-MS could be clearly demonstrated for both the quantitative and qualitative characterization of several commonly used polymer stabilizers [9, 10]. Compared with the APCI source, the ESI signal intensities are higher for almost all analytes with comparable baseline noise. Additionally, detection of some high molecular oligomers of HALS-additives is not possible with APCI or APPI as no multiply charged ions were observed and singly charged ions were not within the detectable mass range (up to 2200 m/z). However, ESI as well as APPI showed a much higher susceptibility towards ion suppression compared to APCI, which makes the latter one the preferred tool for quantitation measurements. With APCI-MS, low limits of detection were obtained and the detector response was shown to be linear over a wide concentration range. In comparison with a validated HPLC-method, the same relative accuracy could be achieved for the analysis of real samples, with the advantage that the proposed methodology allows analyses in a much shorter time than using chromatographic methods. REFERENCES [1] Wang FC. Polymer additive analysis by pyrolysis-gas chromatography IV. Antioxidants. J Chromatogr A. 2000;891:325-36. [2] Carrott MJ, Jones DC, Davidson G. Identification and analysis of polymer additives using packed-column supercritical fluid chromatography with APCI mass spectrometric detection. Analyst. 1998;123:1827-33. [3] Beißmann S, Stiftinger M, Grabmayer K, Wallner G, Nitsche D, Buchberger W. Monitoring the degradation of stabilization systems in polypropylene during accelerated aging tests by liquid chromatography combined with atmospheric pressure chemical ionization mass spectrometry. Polym Degrad Stabil. 2013;98:1655-61. [4] Block C, Wynants L, Kelchtermans M, De Boer R, Compernolle F. Identification of polymer additives by liquid chromatographymass spectrometry. Polym Degrad Stabil. 2006;91:3163-73. [5] Himmelsbach M, Buchberger W, Reingruber E. Determination of polymer additives by liquid chromatography coupled with mass spectrometry. A comparison of atmospheric pressure photoionization (APPI), atmospheric pressure chemical ionization (APCI), and electrospray ionization (ESI). Polym Degrad Stabil. 2009;94:1213-9. [6] Munteanu D, Isfan A, Isfan C, Tincul I. High-Performance Liquid Chromatographic Separation of Polyolefin Antioxidants and Light-Stabilizers. Chromatographia. 1987;23:7-14. [7] Cappiello A, Famiglini G, Palma P, Pierini E, Termopoli V, Trufelli H. Overcoming Matrix Effects in Liquid Chromatography-Mass Spectrometry. Anal Chem. 2008;80:9343-8. [8] Trufelli H, Palma P, Famiglini G, Cappiello A. An Overview of Matrix Effects in Liquid Chromatography-Mass Spectrometry. Mass Spectrom Rev. 2011;30:491-509. [9] Beißmann S, Reisinger M, Reimann A, Klampfl CW, Buchberger W. High-throughput quantification of stabilizers in polymeric materials by flow injection tandem mass spectrometry. Rapid Commun Mass Sp. 2014;28:939-47. [10] Beißmann S, Reisinger M, Toelgyesi L, Klampfl C, Buchberger W. Fast screening of stabilizers in polymeric materials by flow injection-tandem mass spectrometry. Anal Bioanal Chem. 2013;405:6879-84. Agilent Products are for Research Use Only. Not for use in diagnostic procedures. Information, descriptions and specifications in this publication are subject to change without notice. Solutions for your analytical business Markets & Applications Programs www.solutions-to-win.com Agilent Technologies, Inc. 2014 Published in USA, November, 2014 5991-5316EN