ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

Similar documents
OES - Optical Emission Spectrometer 2000

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES

Analysis Repeatability of Trace and Major Elements in a Water Sample

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

U.S. EPA SW-846 Method 6010C using the Prodigy High Dispersion ICP

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

110 Lowell Rd Hudson, NH USA Tel:

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Product Descriptions and Offerings

ICP-OES Application Note Number 35

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

PRINCIPLE OF ICP- AES

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

LIBSlab ANALYZERS ANALYZERS

Optimizing Analytical Performance in ICP-OES Applications

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Overcoming Interferences with the Thermo Scientific icap 7000 Plus Series ICP-OES

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

ICP-Mass Spectrometer

Application of the GD-Profiler 2 to the PV domain

SmartNotes. What is meant by the term interference?

Quantitative analysis of high purity metals using laser ablation coupled to an Agilent 7900 ICP-MS

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Chapter 9. Atomic emission and Atomic Fluorescence Spectrometry Emission spectrophotometric Techniques

GTEK Laboratory Atomic Absorption Spectrometer AAS6000 Brochure

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Overview of X-Ray Fluorescence Analysis

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K.

U.S. EPA SW-846 Method 6010C Using the Prodigy7 High- Dispersion ICP Introduction. Application Note - AN1305. Experimental

Following documents shall be used for reference on quantities, units, prefixes and other technical vocabulary in this document:

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Elemental analysis of river sediment using the Agilent 4200 MP-AES

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

Determination of the Halogen Elements in the Deep UV Region of the Spectrum by ICP - OES

Direct Measurement of Trace Metals in Edible Oils by 7500cx ICP-MS with Octopole Reaction System

INTRODUCTION Atomic fluorescence spectroscopy ( AFS ) depends on the measurement of the emission ( fluorescence ) emitted from gasphase analyte atoms

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

Application. Determination of Trace Metal Impurities in Semiconductor-Grade Hydrofluoric Acid. Authors. Introduction. Abstract.

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Partial Energy Level Diagrams

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

The Evolution of Inductively Coupled Plasma - Optical Emission Spectroscopy (ICP-OES)

Analysis of domestic sludge using the Agilent 4200 MP-AES

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

DETERMINATIONS OF THE POLLUTION LEVEL OF THE ENVIRONMENT WITH HEAVY METALS

Samples compliant with the WATER

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

novaa 800 D Atomic Absorption Spectrometer

Atomic Absorption Spectrometer ZEEnit P series

Hands on mass spectrometry: ICP-MS analysis of enriched 82 Se samples for the LUCIFER experiment

Using cold vapor generation atomic absorption to determine mercury impurities in pharmaceutical products

Meeting the Challenges of Soil Analysis with the Avio 200 ICP-OES

AN INTRODUCTION TO ATOMIC SPECTROSCOPY

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

CHAPTER 4: ANALYTICAL INSTRUMENTATION

Pros and Cons of Water Analysis Methods

Mining Analyzer XRF-3360

Simple and Reliable Soil Analysis using the Agilent 7800 ICP-MS with ISIS 3

Introduction to Fourier Transform Infrared Spectroscopy

CH. 21 Atomic Spectroscopy

Analytical Instruments

LAB REPORT ON XRF OF POTTERY SAMPLES By BIJOY KRISHNA HALDER Mohammad Arif Ishtiaque Shuvo Jie Hong

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

NaturalFacts. Introducing our team. New product announcements, specials and information from New Roots Herbal. April 2009

Analysis of Cadmium (Cd) in Plastic Using X-ray Fluorescence Spectroscopy

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017.

The Investigation of Fertilizer Analyses Using Microwave Digestion and the Agilent 720-ES

Introduction to Fourier Transform Infrared Spectroscopy

Environmental Series - Trace contaminant analysis in brine using a Thermo Scientific icap 6000 Series Duo ICP

Atomic Spectroscopy AA/ICP/ICPMS:

MICRO-TOMOGRAPHY AND X-RAY ANALYSIS OF GEOLOGICAL SAMPLES

Techniques for the Analysis of Organic Chemicals by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

Determination the elemental composition of soil samples

Trace Analyses in Metal Matrices Using the ELAN DRC II

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Agilent G2350A Atomic Emission Detector (AED)

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

25 Instruments for Optical Spectrometry

Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

Putting Near-Infrared Spectroscopy (NIR) in the spotlight. 13. May 2006

Trace Metal Dynamic Extraction from Five Pumps in Hydrochloric Acid. Submitted to: Reto Schoeb Levitronix GmbH. Submitted by:

Jasco V-670 absorption spectrometer

S2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF

Defining quality standards for the analysis of solid samples

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

UV Spectroscopy Determination of Aqueous Lead and Copper Ions in Water

Gamma Analyst Performance Characteristics (MDAs)

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Current State of Extraction Don t Be Deceived! Sharon F. Webb, Ph.D. Director of Quality Program

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy

Transcription:

Inductively Coupled Plasma Optical Emission Spectrometer

Inductively Coupled Plasma Optical Emission Spectrometer Inductively Coupled Plasma Optical Emission Spectrometer is powerful simultaneous full spectrum direct-reading spectrometer designed to trace elemental analysis in various samples with excellent analytical precision and accuracy. ICP2060 has wide wavelength r ange of 190nm to 800nm with 2400 line grating. The instrument features superb optical system, full automation as well as powerful analysis software with auto-matching. Application fields Metallurgical industry: analyze As, Bi, Pb, Sb, Sn and other elements Geological mineral industry: analyze Ca, Mg, Na, Fe, Cu, Mn, Zn, Co, Ni, Au, Ag and other elements in the rock samples Biological and chemical industries Petrochemical and metallurgic industries: Analysis of 30+ elements in crude oils- Fe, Na, Mg, Ni, V, Ca, Pb, Mo, Mn, Cr, Co, Ba, As, etc. Pharmaceutical, Health and Food safety Features Advanced CID detector and Full-frame Imaging entire ICP-OES spectrum can be analyzed(165-900 nm) Fast analysis, analyzing 5-8 elements per minute Intuitive Software controls all parts of the instrument Fast auto-matching Automatic cooling water system 1

Inductively Coupled Plasma Optical Emission Spectrometer Complete automation features full PC-Control and automation Peristaltic pump High precision 12 roller 4 channel peristaltic pump provides smooth and stable sample introduction Automatic - gas flow control Advanced mass flow controller (MFC) controls carrier gas, plasma gas and auxiliary gas and ensures the stability of the sample introduction system and stable light source. Precise wavelength positioning Precise automatic wavelength calibration algorithm completes the measurement without additional peak calibrations, ensuring an accurate measurement at minimum measurement time. Fast, accurate auto-matching The load terminals employs the full-automatic matching technology with fast matching and high precision while achieving maximum power output Ultra-fast analysis speed ICP3000 can set suitable integration time for all analytical lines in one exposure to achieve optimal measurement, or acquire the intensity integral value in the end of the exposure to enable faster analysis Powerful software analysis function Easy to use ICP3000 advanced software features qualitative, semi-quantitative and quantitative analysis, intelligent optimization, flexible full-spectrum research, strong offline reprocessing, intelligence background correction and interference cancellation algorithms Sample introduction system Sample introduction system is equipped with several nebulizers/spray chambers, optional high solids nebulizer and hydrogen fluoride-resistant are available as special order items. Optional Auto sampler simplifies analysis. Superb optical system Echelle-prism polychromator maximizes the flux while enabling excellent spectral resolution. Ultra-low stray light design reduces background interference and improves the detection limits. Excellent performance detector Advanced CID detector and Full-frame Imaging c apture entire ICP-OES spectrum can be analyzed (165-900 nm).excellent linear dynamic range allows measurement of weak emission signals together with strong emission signals while providing flexibility to choose the ideal wavelength Stable solid-state RF power Compact Solid-state RF power delivers reliable performance with power stability and safety 2

Inductively Coupled Plasma Optical Emission Spectrometer Spectrometer Specifications Detector Specifications Grating: 52.67 Ip/mm, 64 blaze angle, Zerodur Detector Type: Charge injection detector (CID) substrate (produced by SCHOTT-Germany) with Pixel Size: 27 x 27, Random Access Integration (RAI) near zero thermal expansion coefficient Read mode: Full frame readout (FF), Random Access Prism: Ultra-pure Corning UV fused silica, transmittance Integration (RAI) with non-destructive read (NDRO) 99.6% at 170nm. Linear dynamic range 10^8 Wavelength range: standard 175nm-900nm, optional Wavelength response range: 165nm-1000nm DUV optical components extend wavelength range to Quantum efficiency: No coating-up to 35% within 165nm 900nm 200nm UV region Focal Length: 430 mm Detector Cooling: High efficiency triple stage Resolution: 0.0068nm@200nm thermoelectric cooling device maintains the detector Optical Chamber: Precise thermostat 35±0.1 C; at -45C N purge: normal purge 2L/min, fast purge 4L/min Stray light: Equivalent background concentration of Other Specifications 10000ppm Ca solution Analysis Speed: Single CID readout time- 2ms, analysis for all elements can be achieved within one minute RF Generator Detection Limits: 1ppb-10ppb for most elements Input/Output Power: AC 220V-input, Stability: relative standard deviation RSD <0.5% (<1% 20A 700-1600W-output within 2 Hours) Stability: Frequency- < 0.05%, output power- <0.1% Size: 130cm x 84cm x 74cm Working Frequency: 27.12MHz Accuracy: 2W 3

Inductively Coupled Plasma Optical Emission Spectrometer Analysis Software Specifying individual pixel or subarray region for quantitative analysis Methods and data set management, re-processing, auto or manual real-time background correction Full frame spectrum mode Qualitative & semi-quantitative analysis of the elements-showing complete emission spectra, intensity, auto-peak identification and interactive spectral library 4

Skyray Instruments USA, Inc 1717 N. Akard Street, Ste 2520 Dallas, Texas, 75201 USA +1 972 638 9035 sales@skyrayinstruments.com Skyray Instruments specializes in the R&D, manufacturing and sales of analytical and measuring instruments in Spectroscopy, Chromatography and Mass Spectroscopy fields. Our Products include X-ray Fluorescence Spectrometry, Atomic Absorption Spectrometry, Gas Chromatography, Inductively Coupled Plasma Spectrometry, Mass Spectrometry and many others Skyray has been providing customers around the world with reliable and affordable Scientific Instruments for more than 20 years Product description and specifications in this document are subject to change without notice. Copying, distributing or any use of material contained in this document for any commercial purpose without permission from Skyray Instruments USA, Inc is prohibited. Printed in USA