station) on the serial port

Similar documents
Weather Stations. Evaluation copy. 9. Post live weather data on the school s web site for students, faculty and community.

Vantage PRO2 Quick. Reference Guide

WeatherLink for Windows

Quick Reference Guide

Product Description. 1 of 6

Website Phone Mobile OVERVIEW Davis Vantage Pro2 Weather Station

Wireless Vantage Pro & Vantage Pro Plus Stations

MxVision WeatherSentry Web Services Content Guide

Vantage Vue Weather Station

3465 Diablo Avenue, Hayward, CA U.S.A Fax:

WM9280. Pro Family weather station with T/H sensor, pluviometer, anemometer, PC connection and Meteotime weather forecasts until 3 days

Wireless Vantage Pro2 & Vantage Pro2 Plus Stations

Cabled Vantage Pro2 & Vantage Pro2 Plus Stations

MKIII -MB USER S GUIDE 09/18/18. Rev. 3

Vantage Pro Technical Reference

Vantage Pro. Console Manual. Weather Station. Product #6310, 6310EU, 6310UK, 6310C, 6310CEU, 6310CUK N NE. S Last 24 hrs Every 1 hr BAROMETER HUM OUT

Wireless Vantage Pro2 & Vantage Pro2 Plus Stations

Non-Acoustical Inputs

WEATHER PRECISION INSTRUMENTS NEW! Vantage Pro Wireless Weather Station

ea980r Digital Anemometer User Manual

CABLE FREE WEATHER STATION

WEATHER MULTI-SENSOR. Vaisala Weather Transmitter WXT510. Change the Way You Measure Weather

NOVALYNX CORPORATION ELEVATION CORRECTION TABLES FOR BAROMETRIC PRESSURE SENSORS

SOFTWARE USER MANUAL. Weather Capture Advance WS1640 WM9280

WeatherSnoop Users Guide Tee-Boy!

The Climate of Bryan County

The Climate of Marshall County

CALEC ST II BACnet MS/TP

TP2700WC PROFESSIONAL WEATHER STATION

O P E R A T I N G M A N U A L

The Climate of Kiowa County

Vantage Pro. Weather Envoy. Installation Manual. Product # 6314 & 6314C

Measure, Monitor, and

The Climate of Texas County

SU solar resource measurement station: Sonbesie metadata

Format of CLIGEN weather station statistics input files. for CLIGEN versions as of 6/2001 (D.C. Flanagan).

Appendix 4 Weather. Weather Providers

BERMAD Irrigation. BIC2000 Weather Station SYSTEM GUIDE VERSIONS : BIC ; PC 4.90

WEATHER ON WHEELS Elementary School Program

Weather MicroServer. User Manual. Version All specifications subject to change without notice. Printed in U. S. A. Weather MicroServer 1

QUICK SET UP MANUAL WEATHER CENTER

Memo. I. Executive Summary. II. ALERT Data Source. III. General System-Wide Reporting Summary. Date: January 26, 2009 To: From: Subject:

The Climate of Pontotoc County

The Climate of Payne County

The Climate of Seminole County

The Climate of Murray County

MODBUS Protocol for CS141 network card families

Mini Environmental Quality Meter

MAST ACADEMY OUTREACH. WOW (Weather on Wheels)

MAST ACADEMY OUTREACH. WOW (Weather on Wheels)


Atmosphere Properties and Instruments. Outline. AT351 Lab 2 January 30th, 2008

The Climate of Grady County

Advanced Weather Station with Wireless Sensor Set Model: WMR90A

WEATHERPAK EOC. Operations & Maintenance Manual. November 26, Coastal Environmental Systems, Inc. P/N: Rev.

isma-b-aac20 isma Weather kit User Manual Version 1.0 Page 1 / 11

MAST ACADEMY OUTREACH. WOW (Weather on Wheels)

2016 EXPLANATION OF OBSERVATIONS BY REFERENCE NUMBER

The Climate of Haskell County

Quick Start Guide New Mountain Visit our Website to Register Your Copy (weatherview32.com)

WEATHER INSTRUMENTS PRECISION NEW DAVIS WEATHER PRODUCTS: See our WEATHER MONITORING SYSTEMS FOR HOME, SCHOOL, INDUSTRY & AGRICULTURE

Lab - Interpreting Weather Station Models.

Class Notes: Weather

Predicting Weather Conditions. Do you have a career as a meteorologist?

BACNET PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT HLS 44-BAC

Name Period Date L.O: students will be able to describe air temperature and air pressure

06MAR THU 12: User Manual

Weather Station P03/3-Modbus-GPS for Modbus

WIND DATA REPORT FOR THE YAKUTAT JULY 2004 APRIL 2005

Earth Networks ENcast 6- Day Hourly Lat- Lon Forecast Feed

SOUTH MOUNTAIN WEATHER STATION: REPORT FOR QUARTER 2 (APRIL JUNE) 2011

Assembly and Operation Manual. April 2016

VT8600 Series BACnet Integration

Page 1. Name:

MaxiMet. Compact Weather Stations. gillinstruments.com

Weather Station P03/3-RS485-GPS with RS485 Interface

Page 1. Name: 1) The graph below shows air temperature for an area near the Earth's surface during a 12-hour period.

For Military, Research, Tactical Portable Vehicle Mount Fixed Base

Weather Monitoring Station Features Easy Wireless Installation and Solar Power

INTRODUCTIONS Part 1

DATA SOURCES FOR A MODEL TO PREDICT AIR TEMPERATURES INSIDE A RESIDENTIAL HOME

Virtual Weather Station Version 12 User's Manual

Construction and Interpretation of Weather Station Models

WeatherHub2 Quick Start Guide

MP3 Digital Voice Module Model No.: VCM-SD Rev.A3. Content

G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to make technical changes at any time without notice.

CABLE FREE WEATHER STATION

WEATHER STATION FOR SOLAR FARM MONITORING

PRECISION WEATHER INSTRUMENTS

Wireless Full Weather Station Kit Model: WMR80 / WMR80A

CABLE FREE TM WEATHER STATION

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

WE TAKE BUILDING AUTOMATION PERSONALLY MANUAL PRESIGO PDT

Weather Practice. 4. As wind velocity decreases, the distance between isobars on a weather map will A) decrease B) increase C) remain the same

LOCAL CLIMATOLOGICAL DATA Monthly Summary July 2013

WEATHER INSTRUMENTS. Precision YOUR WEATHER IN REAL TIME LOCAL OR REMOTE: WEATHER MONITORING SYSTEMS FOR HOME, AGRICULTURE, INDUSTRY AND SCHOOL

The Causes of Weather

WEATHER MAP INFORMATION STATION MODEL. Station Model Lab. Period Date

LOCAL CLIMATOLOGICAL DATA Monthly Summary September 2016

Transcription:

Connects a Davis VantagePro2 or Vantage Vue to a BACnet network BACnet MS/TP over RS-485 compatible Easy BACnet network configuration via onboard switches Various selectable metric and imperial unit conversions Compatible with new Davis firmware; provides additional weather data Configurable alarm on gateway with two open collector outputs Connections Connection Description V + Power Positive (8 to 28V DC; 100mW) GND Power Negative (Ground) D + RS-485 Data + D - RS-485 Data - GND Ground Male DE-9 Serial communications (RS-232) between KTA-302 and Weather station via WeatherLink cable Ethernet The Ethernet connector is not used for BACnet functions. OC1 Open Collector Output 1 OC2 Open Collector Output 2 LED Red Tx LED (next to RS-485 terminal) Green Rx LED (next to RS-485 terminal) Green Rx LED next to DE-9 connector Red Tx LED next to DE-9 connector Function Indicates serial communications sent on RS-485 Indicates serial communications received RS-485 Indicates serial communications received (from weather station) on the serial port Indicates serial communications sent on the serial port Setting Up BACnet Address and Baud Rate The BACnet address and the baud rate are set through the switches near to the RS-485 connector. Setting the Baud Rate: Baud Rate Switch 7 Switch 8 9600 OFF OFF 19200 ON OFF 38400 OFF ON 76800 ON ON Setting the BACnet MAC ID The BACnet MAC ID is set through the bit switches from 1 to 6 using binary decoding. Each switch represents the binary value and the address is set by the combination of those switches. The configurable range is from 0 to 63. See address table bellow. 6 Jun 2017 oceancontrols.com.au 1 of 7

Address SW1 SW2 SW3 SW4 SW5 SW6 Address SW1 SW2 SW3 SW4 SW5 SW6 0 OFF OFF OFF OFF OFF OFF 32 ON OFF OFF OFF OFF OFF 1 OFF OFF OFF OFF OFF ON 33 ON OFF OFF OFF OFF ON 2 OFF OFF OFF OFF ON OFF 34 ON OFF OFF OFF ON OFF 3 OFF OFF OFF OFF ON ON 35 ON OFF OFF OFF ON ON 4 OFF OFF OFF ON OFF OFF 36 ON OFF OFF ON OFF OFF 5 OFF OFF OFF ON OFF ON 37 ON OFF OFF ON OFF ON 6 OFF OFF OFF ON ON OFF 38 ON OFF OFF ON ON OFF 7 OFF OFF OFF ON ON ON 39 ON OFF OFF ON ON ON 8 OFF OFF ON OFF OFF OFF 40 ON OFF ON OFF OFF OFF 9 OFF OFF ON OFF OFF ON 41 ON OFF ON OFF OFF ON 10 OFF OFF ON OFF ON OFF 42 ON OFF ON OFF ON OFF 11 OFF OFF ON OFF ON ON 43 ON OFF ON OFF ON ON 12 OFF OFF ON ON OFF OFF 44 ON OFF ON ON OFF OFF 13 OFF OFF ON ON OFF ON 45 ON OFF ON ON OFF ON 14 OFF OFF ON ON ON OFF 46 ON OFF ON ON ON OFF 15 OFF OFF ON ON ON ON 47 ON OFF ON ON ON ON 16 OFF ON OFF OFF OFF OFF 48 ON ON OFF OFF OFF OFF 17 OFF ON OFF OFF OFF ON 49 ON ON OFF OFF OFF ON 18 OFF ON OFF OFF ON OFF 50 ON ON OFF OFF ON OFF 19 OFF ON OFF OFF ON ON 51 ON ON OFF OFF ON ON 20 OFF ON OFF ON OFF OFF 52 ON ON OFF ON OFF OFF 21 OFF ON OFF ON OFF ON 53 ON ON OFF ON OFF ON 22 OFF ON OFF ON ON OFF 54 ON ON OFF ON ON OFF 23 OFF ON OFF ON ON ON 55 ON ON OFF ON ON ON 24 OFF ON ON OFF OFF OFF 56 ON ON ON OFF OFF OFF 25 OFF ON ON OFF OFF ON 57 ON ON ON OFF OFF ON 26 OFF ON ON OFF ON OFF 58 ON ON ON OFF ON OFF 27 OFF ON ON OFF ON ON 59 ON ON ON OFF ON ON 28 OFF ON ON ON OFF OFF 60 ON ON ON ON OFF OFF 29 OFF ON ON ON OFF ON 61 ON ON ON ON OFF ON 30 OFF ON ON ON ON OFF 62 ON ON ON ON ON OFF 31 OFF ON ON ON ON ON 63 ON ON ON ON ON ON BACnet Services Supported Read Property Read Property Multiple Write Property Device Communication Control Reinitialise Device Who-Has Who-Is Standard Object-Types Supported Analogue Input Analogue Value Binary Value Device Date Value Integer Value Time Value Data Link Layer Option BACnet MS/TP master. Baud rates: 9600, 19200, 38400 and 78800 6 Jun 2017 oceancontrols.com.au 2 of 7

Device Object Properties Property Name/ID Access Default Object Identifier R 838000 + MAC Address Object Name R KTA-302 Object Type R Device System Status R Operational Vendor Name R Ocean Controls Vendor Identifier R 838 Model Name R KTA-302 BACnet Protocol Version R 1 Protocol Revision R 14 Max APDU Lenght R 128 APDU Timeout R 3000 ms Number APDU Retries R 3 Analogue Input Objects Analogue Input Objects are the values read from the Davis Weather Station. Analogue Objects Properties Object Identifier R See table bellow Object Name R See table bellow Object Type R ANALOG INPUT Present Value R Value read from Weather Station * Event State R NORMAL Out Of Service R FALSE Units R/W See table bellow for default *Alarm Flag set to true when the Davis Weather Station alarm is reached. The alarms have to be configured by Weather Link Software or on Weather Station Console. Analogue Objects Supported Object Name Instance Default Unit Supported Units Barometer Trend 3h 0 No_Units No_Units Barometer 1 mmhg InHg,mmHg,mb Inside Temperature 2 Deg C Deg F, Deg C Inside Humidity 3 % % Outside Temperature 4 Deg C Deg F, Deg C Wind Speed 5 m/s Mph, m/s, fps, kph Wind Speed Average 6 m/s Mph, m/s, fps, kph Wind Direction 7 Deg Deg Angular Extra Temperature 1 8 Deg C Deg F, Deg C Extra Temperature 2 9 Deg C Deg F, Deg C Extra Temperature 3 10 Deg C Deg F, Deg C Extra Temperature 4 11 Deg C Deg F, Deg C Extra Temperature 5 12 Deg C Deg F, Deg C Extra Temperature 6 13 Deg C Deg F, Deg C Extra Temperature 7 14 Deg C Deg F, Deg C 6 Jun 2017 oceancontrols.com.au 3 of 7

Soil Temperature 1 15 Deg C Deg F, Deg C Soil Temperature 2 16 Deg C Deg F, Deg C Soil Temperature 3 17 Deg C Deg F, Deg C Soil Temperature 4 18 Deg C Deg F, Deg C Leaf Temperature 1 19 Deg C Deg F, Deg C Leaf Temperature 2 20 Deg C Deg F, Deg C Leaf Temperature 3 21 Deg C Deg F, Deg C Leaf Temperature 4 22 Deg C Deg F, Deg C Outside Humidity 23 % % Extra Humidity 1 24 % % Extra Humidity 2 25 % % Extra Humidity 3 26 % % Extra Humidity 4 27 % % Extra Humidity 5 28 % % Extra Humidity 6 29 % % Extra Humidity 7 30 % % Rain Rate per Hour 31 mm In, mm UV Index 32 No_units No_units Solar Radiation 33 W/m2 W/m2 Storm Rain 34 mm In, mm Day Rain 35 mm In, mm Month Rain 36 mm In, mm Year Rain 37 mm In, mm Day Evapotranspiration 38 mm In, mm Month Evapotranspiration 39 mm In, mm Year Evapotranspitarion 40 mm In, mm Soil Moisture 1 41 millibar millibar Soil Moisture 2 42 millibar millibar Soil Moisture 3 43 millibar millibar Soil Moisture 4 44 millibar millibar Leaf Weatenesses 1 45 No_Units No_Units Leaf Weatenesses 2 46 No_Units No_Units Leaf Weatenesses 3 47 No_Units No_Units Leaf Weatenesses 4 48 No_Units No_Units Console Battery Voltage 49 V V Wet Bulb 50 Deg C Deg F, Deg C Wind Speed last 2 minutes 51 m/s Mph, m/s, fps, kph Wind Gust last 10 minutes 52 m/s Mph, m/s, fps, kph Wind Direction for 10 minutes gust 53 m/s Mph, m/s, fps, kph Dew Point 54 Deg C Deg F, Deg C Heat Index 55 Deg C Deg F, Deg C Wind Chill 56 Deg C Deg F, Deg C THSW Index 57 Deg C Deg F, Deg C Rain Last 15 minutes 58 mm In, mm Rain Last Hour 59 mm In, mm Rain Last 24 Hours 60 mm In, mm Barometric Sensor Raw Reading 61 mmhg InHg,mmHg,mb Absolute Barometric Pressure 62 mmhg InHg,mmHg,mb 6 Jun 2017 oceancontrols.com.au 4 of 7

Analogue Units Supported Unit Abrev. BACnet Code Degrees Fahrenheit Deg F 64 Degrees Celsius Deg C 62 Percent Relative Humidity % 29 Inches Of Mercury inhg 61 Millimetres of Mercury mmhg 59 Millibar mb 134 Inches In 32 Millimetres mm 30 Miles per Hour mph 78 Meters per Second m/s 74 Feet per Second fps 76 Kilometres per Hour kph 75 Volts V 5 Degrees Angular Deg 90 Watts per Square Meter W/m2 35 No Units No_Units 95 Time Objects Time Objects are read from the Davis Weather Station. Time Object Properties Object Name R (0) Time of Sunset (1) Time of Sunrise Object Type R TIME (50) Present Value R Values are read from Weather Station *These values require longitude and latitude to be set. Longitude and latitude can be set using the WeatherLink software or the Weather Station console. Date Object Date Object is read from the Davis Weather Station. Date Object Properties Object Identifier R 0 Object Name R Start date of current storm Object Type R DATE (42) Present Value R Value is read from Weather Station *These values require longitude and latitude to be set. Longitude and latitude can be set using the WeatherLink software or the Weather Station console. Analogue Value Objects Analogue Value Objects define the alarm set point value. See Alarm Section for further information. 6 Jun 2017 oceancontrols.com.au 5 of 7

Analogue Value Object Properties Object Name R (0) Set Point 1 (1) Set Point 2 Object Type R ANALOG VALUE Present Value R/W 0 Event State R NORMAL Out Of Service R FALSE Units R No_Units Relinquish Default R 0 *Proprietary Property /3306 R/W 1 See on Alarm Section *Proprietary Property has data type Enumerated. Integer Value Objects Integer Value Objects define which instance number will be controlled by alarm set points. See Alarm Section for further information. Integer Value Object Properties Object Name R (0) Instance of SP1 (1) Instance of SP2 Object Type R INTEGER VALUE Present Value R/W 0 Instance number of Analogue Input Object that should be controlled by alarm. Out Of Service R/W TRUE Write true to disable respective alarm Units R No_Units Relinquish Default R 0 Binary Value Objects Binary Value Objects show the status of the alarm open collector outputs. See Alarm Section for further information. Binary Value Object Properties Object Name R (0) OC Output 1 (1) OC Output 2 Object Type R BINARY VALUE Present Value R 0 Status of output Out Of Service R FALSE Event State R NORMAL Polarity R NORMAL 6 Jun 2017 oceancontrols.com.au 6 of 7

Alarms The KTA-302 BACnet Gateway provides two configurable alarms which can enable or disable two open collector outputs. To activate those alarms, the user has to set false in the Out of Service property of the Integer Value Object and configure the desirable parameters. Alarm 1 Object/Name Property Integer Value 0 / Instance of SP1 Present Value Write the instance number of the analogue input object to be controlled. Integer Value 0 / Instance of SP1 Out Of Service Enable or Disable the alarm Analogue Value 0 / Set Point 1 Present Value Write the desirable set point Analogue Value 0 / Set Point 1 Proprietary Property / 3306 Activate Alarm when: 0 Equal to SP 1 Greater than SP 2 Lower than SP 3 The alarm flag is activated Binary Value 0 / OC Output 1 Present Value Shows status of the OC1 output. Alarm 2 Object/Name Property Note Integer Value 1 / Instance of SP2 Present Value Write the instance number of the analogue input object to be controlled. Integer Value 1 / Instance of SP2 Out Of Service Enable or Disable the alarm Analogue Value 1 / Set Point 2 Present Value Write the desirable set point Analogue Value 1 / Set Point 2 Proprietary Property / 3306 Activate Alarm when: 0 Equal to SP 1 Greater than SP 2 Lower than SP 3 The alarm flag is activated Binary Value 1 / OC Output 2 Present Value Shows status of the OC2 output. 6 Jun 2017 oceancontrols.com.au 7 of 7