TECHNICAL BRODIFACOUM

Similar documents
PYRIPROXYFEN TECHNICAL

TECHNICAL TEMEPHOS. 1. Specification. Full specification WHO/SIT/19.R4 Revised 10 December Description

H 3 CO H 3 CO S CH 3

TECHNICAL DIAZINON. 1. Specification. Full specification WHO/SIT/9.R7 Revised 10 December Description

637. Thiamethoxam. HPLC method

CIPAC. CIPAC Free relevant impurities methods:

ARTEMETHER AND LUMEFANTRINE ORAL SUSPENSION:Final text for addition to The International Pharmacopoeia (November 2008)

IDENTIFICATION AND DETERMINATION OF HYDROQUINONE IN COSMETIC PRODUCTS 2 14/11/17 ACM 003 BY TLC AND HPLC

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

ARTEMETHER AND LUMEFANTRINE TABLETS: Final text for addition to The International Pharmacopoeia (July 2008)

NEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009)

DIQUAT DIBROMIDE. The Determination of Ethylene Dibromide in Diquat Dibromide and Diquat Dibromide / Paraquat Dichloride SL Formulations

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

This method describes the identification of the following prohibited colorants in cosmetic products:

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

Diquat 1,1 -ethylene-2,2 -bipyridium dibromide salt Paraquat 1,1 -dimethyl-4,4 -bipyridium dichloride salt Initial Preparation

TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)

High Performance Liquid Chromatography (HPLC) of Three Analgesics

Sulfotepp impurities in Chlorpyrifos EC formulations

1. A gas chromatograph equipped with flame ionization detection and a computing integrator.

LUMEFANTRINUM LUMEFANTRINE

EFAVIRENZ Final text for addition to The International Pharmacopoeia

The analysis of organic acid content of additives, premix, feed, and water.

Technical Procedure for Solid Phase Extraction of THC and THC-COOH for GC-MS Analysis

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Determination of Caffeine by HPLC

METHANOLYSIS OF ACETAL

Sodium Chloride - Analytical Standard

Method for Characterization of Gum Rosin by Capillary Gas Chromatography

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

12 Nicarbazin Nicarbazin (4,4 -dinitro carbanilid (DNC) and 2-hydroxy-4,6-dimethyl pyrimidine (HDP))

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF

ACETONE IN URINE BY UV CODE Z42010

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

CORESTA Recommended Method No. 86

Gluten (Gliadin) Lateral Flow IIR

RESOLUTION OENO 33/2004 DETERMINATION OF SHIKIMIC ACID IN WINE BY HPLC AND UV-DETECTION

ASPARTAME. Not less than 98% and not more than 102% on the dried basis. White, odourless, crystalline powder, having a strong sweet taste

Revision Bulletin 27 Jan Feb 2017 Non-Botanical Dietary Supplements Compliance

ANALYTICAL CHEMISTRY. Basic Skills in Chemical Laboratory

Revision Bulletin 29 Dec Jan 2018 Non-Botanical Dietary Supplements Compliance

Ondansetron Hydrochloride Tablets

Draft Method proposal: determination of glucoheptonic acid (HGA) in fertilizers.

contents of the currently official monograph. Please refer to the current edition of the USP NF for official text.

CYCLOSERINE Final text for addition to The International Pharmacopoeia. (November 2008) CYCLOSERINUM CYCLOSERINE

Anethole. Gas chromatograhpy determination of trans-anethole in Spirit srinks of viti-vinicultural origin

LEAD (Colorimetric) 2. Muffle Furnace: Equipped with pyrometer and capable of operating at controlled temperatures up to 500 C

CfE Higher Chemistry. Unit 3: Chemistry in Society. Chemical Analysis as part of quality control

BRIEFING. Pharmacopeial Discussion Group Sign Off Document Attributes EP JP USP Definition Loss on drying Readily carbonizable substances

Chemistry Gas Chromatography: Separation of Volatile Organics

This protocol is a modified version of the DuBois assay (DuBois et al. 1956) for the quantification of total carbohydrate content of a sample.

CHAPTER - 3 ANALYTICAL PROFILE. 3.1 Estimation of Drug in Pharmaceutical Formulation Estimation of Drugs

Quantitative determination of ethephon in soluble concentration (SL) by Ion chromatography

Micro Volume QuEChERS kit

TERTIARY BUTYLHYDROQUINONE

25-OH VITAMIN D 3 AND 25-OH VITAMIN D 2 IN PLASMA BY UV / VIS FAST CODE Z19710

VMA, HVA, 5-HIAA Urine LC-MS/MS Analysis Kit User Manual

HIPPURIC ACID and o-m-p- METHYLHIPPURIC ACIDS IN URINE BY UV CODE Z06010

Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV*

Minimizing Solvent Impact on Purification of Nitrogencontaining

CHEMISTRY DEPARTMENT

25-OH VITAMIN D 3 IN PLASMA BY UV FAST CODE Z19610

The Isosorbide Mononitrate Extended-Release Tablets Revision Bulletin supersedes the currently official monograph.

ANALYTICAL METHOD PROCEDURES

Detection limit: grain, feed 500 ppb; milk 50 ppb; cream, cheese 5 ppb

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

INSTRUCTIONS FOR WRITING CIPAC METHODS

GAFTI Analytical method for ISO/TS 16179:2012 Detection and Determination of Organotin Compounds in Footwear and Apparel Materials by GC-MS

Annex 2 Formaldehyde

Cyanide, colorimetric, pyridine-pyrazolone

Determination of trace anions in concentrated hydrofluoric acid

MEDROXYPROGESTERONE INJECTION

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets

FLUDEOXYGLUCOSE ( 18 F) INJECTION: Final text for addition to The International Pharmacopoeia (January 2009)

METHOD 7199 DETERMINATION OF HEXAVALENT CHROMIUM IN DRINKING WATER, GROUNDWATER AND INDUSTRIAL WASTEWATER EFFLUENTS BY ION CHROMATOGRAPHY

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

POLYVINYL ALCOHOL. SYNONYMS Vinyl alcohol polymer, PVOH, INS No DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

Functional Genomics Research Stream. Lecture: February 17, 2009 Masses, Volumes, Solutions & Dilutions

The Nitrofurantoin Capsules Revision Bulletin supersedes the currently official monograph.

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC)

Chapter 12 Tex-617, Determining Chloride in Concrete

STANDARD OPERATING PROCEDURES

Appendix II- Bioanalytical Method Development and Validation

FORMALDEHYDE IN URINE by UV Code Z65010

1. Preliminary qualitative analysis of unknown substances (liquid or solid).

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. NY/T Translated English of Chinese Standard: NY/T

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

METHADONE and EDDP in urine by GC-MS Code GC Method of Confirmation by GC-MS

Carbonate content. SCAN-N 32:98 Revised White, green and black liquors and burnt lime sludge

Should you have any questions, please contact Mary P. Koleck, Ph.D., Scientific Liaison ( or

Certified Reference Material - Certificate of Analysis Methylone, Primary Standard

METHOD 8430 ANALYSIS OF BIS(2-CHLOROETHYL) ETHER AND HYDROLYSIS PRODUCTS BY DIRECT AQUEOUS INJECTION GC/FT-IR

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Transcription:

BRODIFACOUM Full specification: Approved 10 December 1999 1. Specification 1.1 Description The material shall consist of brodifacoum together with related manufacturing impurities and shall be in the form of a white to pale buff powder, free from odour and visible extraneous matter and added modifying agents. 1.2 Chemical and Physical Requirements The material, sampled from any part of the consignment (see method WHO/M/1.R1), shall comply with the requirements of Section 1.1 and with the following requirements. 1.2.1 Brodifacoum content (g/kg basis) The brodifacoum content shall be declared (not less than 880 g/kg) and when determined by the method described in section 2.1, the mean measured content obtained shall not be lower than the declared content. 1.2.2 Brodifacoum cis-trans isomer ratio The cis-trans isomer ratio shall be declared and shall be in the range of 50: 50 to 80: 20 when determined by the method described in section 2.2. 1.2.3 Loss on drying at 100 C The maximum loss on drying at 100 C when determined by the method described in section 2.3 shall be 5 g/kg. 1.3 Packing and marking of packages The technical brodifacoum shall be packed in suitable clean containers, as specified in the order. All packages shall bear, durably and legibly marked on the container, the following: Manufacturer s name Technical brodifacoum 1

Actual cis/trans isomer ratio of the batch Batch or reference number, and date of test Net weight of contents Date of manufacture and the following minimum cautionary notice. Brodifacoum is an indirect anticoagulant and is hazardous if swallowed. Avoid skin contact; wear protective gloves, clean protective clothing, and suitable respiratory protection when handling the material. Open and handle only in a cabinet with adequate exhaust ventilation. Wash hands and exposed skin thoroughly after using and destroy contaminated clothing. Keep containers out of the reach of children and well away from foodstuffs and animal feed and their containers. Brodifacoum is toxic to aquatic wildlife. Avoid accidental contamination of water. If poisoning occurs, call a physician. Treatment is symptomatic. 2. Methods of determining chemical and physical properties 2.1 Brodifacoum 2.1.1 Summary of method A weighed sample of technical brodifacoum is dissolved in triphenylbenzene internal standard solution and determined by reverse phase HPLC with UV detection 2.1.2 Apparatus 1. Liquid chromatograph, equipped with 10 µl loop injector. UV detector capable of operating at 254 nm and a suitable electronic integrator or laboratory data system. 2. Chromatographic column, stainless steel, 250 x 4.6 mm (i.d.) with Zorbax ODS 5 µm, reverse phase column (DuPont Instruments Inc), or equivalent. 2.1.3 Reagents 1,3,5 Triphenylbenzene, internal standard, purity greater than 97%. Acetic acid, glacial, HPLC grade Dichloromethane, HPLC grade Methanol, HLPC grade Water, HLPC grade Brodifacoum of known purity Diluting solvent: dichloromethane-methanol (2+3) v/v Eluting solvent: methanol-water-acetic acid (94.2 + 5.0 + 0.8) v/v 2

Mix 942 ml methanol, 50 ml water and 8 ml acetic acid, filter and degas. 2.1.4 Preparation of standard solutions Internal standard solution. Weight about 100 mg of 1,3,5 triphenylbenzene into a 500 ml volumetric flask, dissolve in dichloromethane (200 ml) and dilute to volume with methanol. Mix thoroughly. Check for interfering components by injecting 10 µl into the liquid chromatograph. Store in a tightly capped dark glass bottle to avoid evaporation and decomposition. Brodifacoum calibration solution. Weigh (to the nearest 0.1 mg) about 100 mg brodifacoum (s g) into a 100 ml volumetric flask, dissolve in dichloromethane (40 ml) and make up to volume with methanol. Mix thoroughly. Transfer by pipette 10.0 ml into a 50 ml volumetric flask, add by pipette internal standard solution (10.0 ml) and make up to volume with the diluting solvent. Mix thoroughly. Store in a tightly capped dark glass bottle to avoid evaporation and decomposition. 2.1.5 Operating conditions The conditions given below are typical values and may have to be adjusted to obtain optimum results from the apparatus used. Eluting solvent flow rate 1 ml min -1 Temperature ambient Injection volume 10 µl Wavelength 254 nm Retention times Brodifacoum: 6.2 min, internal standard: 11.7 min 2.1.6 Sample preparation Weigh (to the nearest 0.1 mg) into a 100 ml volumetric flask enough sample (w g) to contain about 100 mg brodifacoum. Dissolve in dichloromethane (40 ml) and dilute to volume with methanol. Mix thoroughly. Transfer 10.0 ml into a 50 ml volumetric flask, add by pipette internal standard solution (10.0 ml) and make up to volume with the diluting solvent. Mix thoroughly. 2.1.7 Equilibration of the system Inject two or more 10 µl aliquots of the calibration solution into the liquid chromatograph to set the integration parameters and to stabilise the instrument. Continue with injections until the peak area ratios of the brodifacoum peaks to the internal standard peaks for successive injections agree within 2%. 2.1.8 Analysis of sample 3

Carry out duplicate injections of calibration and sample solutions (in the order calibration, sample, sample, and calibration). Average the peak area ratios of the calibration injection (R ) and of the sample injections. ( R ). 2.1.9 Calculation area brodifacoum peak ( R ) = area internal standard peak Brodifacoum content = R x s x P R x w g/kg R = average peak area ratio of brodifacoum and internal standard for the sample R = average peak area ratio of brodifacoum and internal standard for the calibration solution w = mass of sample (g) s = mass of brodifacoum in the calibration solution (g) P = purity of brodifacoum (g/kg). 2.2 Determination of cis/trans isomer ratio 2.2.1 Summary of method A weighed sample of technical brodifacoum is dissolved in dichloromethane and the isomer ratio determined by HPLC with UV detection 2.2.2 Apparatus Liquid chromatograph, equipped with 10 µl loop injection, UV detector capable of operating at 254 nm and a suitable recorder, or electronic integrator, or laboratory data system. Chromatographic column, stainless steel, 250 x 4.6 mm (i.d.) with Spherisorb S5W or Lichrosorb SI60. 2.2.3 Reagents Acetic acid, glacial, HLPC grade Dichloromethane, HLPC grade Hexane, HLPC grade Brodifacoum of known purity Eluting solvent: Hexane-dichloromethane-acetic acid (74.8 + 25 + 0.2) v/v Mix 748 ml hexane, 250 ml dichloromethane and 2 ml acetic acid, filter and degas. 4

2.2.4 Operating conditions The conditions given below are typical values and may have to be adjusted to obtain optimum results from the apparatus used. Eluting solvent flow rate 2 ml min -1 Temperature ambient Injection volume 10 µl Wavelength 254 nm Retention times Trans isomer 14 minutes Cis isomer 15.7 minutes 2.2.5 Sample preparation Weigh (to the nearest 0.1 mg) into a 50 ml volumetric flask, enough sample to contain 20 mg brodifacoum. Dissolve in dichloromethane (20 ml) and dilute to volume with dichloromethane. Mix thoroughly. 2.2.6 Equilibration of the system Inject two or more 10 µl aliquots of sample solution into the liquid chromatograph to set the integration parameters and to stabilise the instrument. 2.2.7 Analysis of sample Inject two 10 µl aliquots of sample solution in succession and record the integrated areas for each peak. Average the integrated areas for each of the peaks. 2.2.8 Calculation Cis isomer content of sample = C x 100% C + T Trans isomer content of sample = C = mean area of cis isomer peaks T = mean area of trans isomer peaks 2.3 Loss on drying at 100 C Outline of Method T C + T x 100% The material is heated at 100 C for 4h, and the loss of water and volatile materials calculated. 5

Apparatus Squat type weighing bottle - 50 mm diameter, 30 mm high Oven at 100 ± 2 C Desiccator Procedure Heat the weighing bottle at 100 ± 2 C for 1h, cool in a desiccator and weigh. Place about 2.5 g of the sample in a thin layer in the tared weighing bottle (x g) and weigh (y g). Heat (without lid) to 100 ± 2 C for 4h, replace lid, cool in the desiccator, and reweigh (z g). Loss on drying = 100 (y-z) (y-x) % w/w 6

5 and 25 g/kg CONCENTRATES WHO/SRoF/1 1. Specification 1.1 Description BRODIFACOUM 5 and 25 g/kg CONCENTRATES Full specification: WHO/SRoF/1 Approved 10 December 1999 The material shall consist of a solution of technical brodifacoum, complying with the WHO specification, as its triethanolamine salt, together with any necessary formulants and a red or blue dye. It shall be free from visible suspended matter and sediment. 1.2 Chemical and physical requirements The material sampled from any part of the consignment (see method WHO/M/1;R1), shall comply with the requirements of sections 1.1 and with the following requirements. 1.2.1 Brodifacoum content (g/kg basis) The content of brodifacoum determined by the method described in section 2.1 shall not differ from the declared content by more than the following amounts: Declared content Up to 25g/kg Tolerance permitted ± 15% of the declared content The average content of all samples taken shall not be lower than the declared content. 1.3 Packing and marking of packages The brodifacoum concentrate shall be packed in suitable clean containers, as specified in the order. All packages shall bear, durably and legibly marked on the container, the following: Manufacturer s name Brodifacoum concentrate Brodifacoum...mg/kg Batch or reference number, and date of test Net weight of contents Date of manufacture Instruction for use and the following minimum cautionary notice: 11

5 and 25 g/kg CONCENTRATES WHO/SRoF/1 Brodifacoum is an indirect anticoagulant and is hazardous if swallowed. Avoid skin contact; wear protective gloves and clean protective clothing when handling the material. Wash hands and exposed skin thoroughly after using. Keep containers out of the reach of children and well away from foodstuffs and animal feed and their containers. Brodifacoum is toxic to aquatic wildlife. Avoid accidental contamination of water. If poisoning occurs, call a physician. Treatment is symptomatic. 2. Methods of determining chemical and physical properties 2.1 Brodifacoum content 2.1.1 Summary of method A weighed sample of brodifacoum concentrate is dissolved in triphenylbenzene internal standard solution and determined by reverse phase HLPC with UV detection. 2.1.2 Apparatus 1. Liquid chromatograph, equipped with 10 µl loop injector. UV detector capable of operating at 254 nm and a suitable electronic integrator, or laboratory data system. 2. Chromatographic column, stainless steel, 250x4.6 mm (i.d.) with Zorbax ODS 5 µm, reverse phase column (DuPont Instruments Inc), or equivalent. 2.1.3 Reagents 1,3,5-Triphenylbenzene internal standard purity greater than 97%. Acetic acid, glacial, HPLC grade Dichloromethane, HLPC grade Methanol, HLPC grade Water, HLPC grade Brodifacoum of known purity Diluting solvent: dichloromethane-methanol (2+3) v/v Eluting solvent: methanol-water-acetic acid (94.2 + 5.0 + 0.8) v/v Mix 942 methanol, 50 ml water and 8 ml acetic acid, filter and degas 2.1.4 Preparation of standard solutions Internal standard solution. Weigh about 100 mg 1,3,5-triphenylbenzene into a 500 ml volumetric flask, dissolve in dichloromethane (200 ml) and dilute to volume with methanol. Mix thoroughly. Check for interfering components by injecting 10 µl into the liquid chromatograph. Store in a tightly capped dark glass bottle to avoid evaporation and decomposition. 12

5 and 25 g/kg CONCENTRATES WHO/SRoF/1 Brodifacoum calibration solution. Weigh (to the nearest 0.1 mg) about 100 mg brodifacoum (s g) into a 100 ml volumetric flask, dissolve in dichloromethane (40 ml) and make up to volume with methanol. Mix thoroughly. Transfer by pipette 10.0 ml into a 50 ml volumetric flask, add by pipette internal standard solution (10.0 ml) and make up to volume with the diluting solvent. Mix thoroughly. Store in a tightly capped dark glass bottle to avoid evaporation and decomposition. 2.1.5 Operating conditions The conditions given below are typical values and may have to be adjusted to obtain optimum results from a given apparatus. Eluting solvent flow rate 1 ml min -1 Temperature ambient Injection volume 10 µl Wavelength 254nm Retention times Brodifacoum: 6.2 min, internal standard: 11.7 min 2.1.6 Sample preparation Weigh (to the nearest 0.1 mg) into a 100 ml volumetric flask enough sample (w g) to contain about 100 mg of brodifacoum. Dissolve in dichloromethane (40 ml) and dilute to volume with methane. Mix thoroughly. Transfer by pipette 10.0 ml into a 50 ml volumetric flask, add by pipette internal standard solution (10.0 ml) and make up to the mark with diluting solvent. Mix thoroughly and filter through a 0.45 µm filter. 2.1.7 Equilibration of the system Inject two or more 10 µl aliquots of the calibration solution into the liquid chromatograph to set the integration parameters and to stabilise the instrument. Continue with injections until the peak area ratios of the brodifacoum peaks to the internal standard peaks for successive injections agree within 2%. 2.1.8 Analysis of sample Carry out duplicate injections of calibration and sample solutions (in the order calibration, sample, sample and calibration). Average the peak area ratios of the calibration injections (R ) and of the two sample injections ( R ). ( R ) = area brodifacoum peak area internal standard peak 13

5 and 25 g/kg CONCENTRATES WHO/SRoF/1 2.1.9 Calculation Brodifacoum content = Where: R x s x P R x w g/kg R = average peak area ratio of brodifacoum and internal standard for the sample. R = average peak area ratio of brodifacoum and internal standard for the calibration solution w = mass of sample (g) s = mass of brodifacoum in the calibration solution (g) P = purity of brodifacoum (g/kg) 14