GLP Series Planar HPGe Low-Energy Detector Product Configuration Guide

Similar documents
ORTEC. GLP Series Planar HPGe Low-Energy Detector Product Configuration Guide. Configuration Guidelines

High-Performance Germanium Coaxial Detectors for Safeguards and Non-Destructive Assay Product Configuration Guide

ORTEC. SLP Series Silicon Lithium-Drifted Planar Low-Energy X Ray Detector Product Configuration Guide

ORTEC. GEM Series Coaxial HPGe Detector Product Configuration Guide. Configuration Guidelines

ORTEC. GEM Series Coaxial HPGe Detector Product Configuration Guide. Configuration Guidelines

ORTEC. PROFILE Coaxial HPGe Photon Detector Product Configuration Guide

ORTEC GMX Series Coaxial HPGe Detector Product Configuration Guide

ORTEC. October 23, 2017 Product Guide

Flanged Cryostats.

Advanced and Special Detector Programs from ORTEC Historical and Next Step Perspective

Chem 481 Lecture Material 3/20/09

ORTEC was founded in 1960 by researchers from Oak Ridge National Labs to commercialize charged particle detectors

PROFILE S and C Series P-type Semi-planar and Coaxial HPGe Detectors

Gamma and X-Ray Detection

ORTEC. Overview of Semiconductor Photon Detectors. GEM (P-type) and GAMMA-X (N-type) Coaxial Detectors. Efficiency as a Function of Energy

PROFILE S and C Series

Microscopy Cryostat System

AGATA preamplifier performance on large signals from a 241 Am+Be source. F. Zocca, A. Pullia, D. Bazzacco, G. Pascovici

Optimization of Electrically Cooled Complex HPGe Detector

Compton suppression spectrometry

ISOCS / LabSOCS. Calibration software for Gamma Spectroscopy

Acceptance test of the AGATA Ge detectors

Freescale Semiconductor

Determination of the shielding power of different materials against gamma radiation

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

The first model was based only on the CANBERRA information which we. drawing. Canberra refused any other information.

Study of PC-HPGe detector for dark matter search

arxiv: v1 [physics.ins-det] 14 Nov 2017

First tests of the big volume ultra low background gamma spectrometer

The GERDA Phase II detector assembly

S8 TIGER Series 2 for ASTM D 6443

High Purity Germanium Detector Calibration at ISOLDE

Establishing an ISO-CART Measurement Station to Meet Government Burial Regulations for Radioactive Material

RMCC CANBERRA Latest developments

A dual scintillator - dual silicon photodiode detector module for intraoperative gamma\beta probe and portable anti-compton spectrometer

Pulse Height Analysis System (PHA) designed for W7-X Presented by Monika KUBKOWSKA

Background Reduction Using Collimators on a Portable HPGe Nuclide Identifier

THE HALL EFFECT. Theory

HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F

TROPOMI. Sentinel 5 Precursor instrument for air quality and climate observations. R. Voors Dutch Space. ICSO, 11 October 2012

RADEAGLET. Lightweight Handheld Radioisotope Identification Device

FRAM V5.2. Plutonium and Uranium Isotopic Analysis Software

ORDERING INFORMATION # of Ports Pressure Type Device Name

HPGe detector fabrication at CANBERRA. V. Marian, M.O. Lampert, B. Pirard, P. Quirin, J. Flamanc CANBERRA Specialty Detectors (Lingolsheim)

QuantumMCA QuantumNaI QuantumGe QuantumGold

ORTEC Experiment 7. High-Resolution Gamma-Ray Spectroscopy. Equipment Required. Purpose. Introduction

HiPace 1200, with TC 1200, DN 200 CF-F

HFM 100 Series. Thermal Conductivity Meter for measurement of insulation and construction materials.

EFFICIENCY AND RESOLUTION OF GERMANIUM DETECTORS AS A FUNCTION OF ENERGY AND INCIDENT GEOMETRY

HARTING D-Sub Selection Guide

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

CB FDHMT. Contract No GSI Helmholzzentrum für Schwerionenforschung GmbH Planckstraße Darmstadt. 15. December /11

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

PINS3-CW. Portable Chemical Identification System

Technical Note 103. Response Enhancement for the Loral CCDs. using Ultra-Violet Flooding. A. P. Oates (RGO)

Outline. Introduction, motivation Readout electronics, Peltier cooling Input J-FETsJ

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

PHY3901 PHY3905. Hall effect and semiconductors Laboratory protocol

Grounding and Shielding

Summary of readout test of DSG prototype with IPA4 cold preamp. C. Cattadori, M. Bernabe-Heider, O. Chkvorets, K. Gusev, M.

Pulse-shape shape analysis with a Broad-energy. Ge-detector. Marik Schönert. MPI für f r Kernphysik Heidelberg

HiPace 300 with TC 110, DN 100 CF-F

HDice overview A.M. Sandorfi

NUCL 3000/5030 Laboratory 2 Fall 2013

1 of :32

The Shape of the Full-Energy Gamma Ray Peak in Germanium Detectors for Different Energies and Incident Geometries

PINS3-CF. Portable Chemical and Explosive Identification System

Effect of Co-60 Single Escape Peak on Detection of Cs-137 in Analysis of Radionuclide from Research Reactor. Abstract

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

FATEK. FBs-1HLC. Precision Load Cell Module. Operation manual V1.1 06/07/2017 FATEK AUTOMATION CORP.

arxiv:astro-ph/ v1 4 Sep 2001

ɣ-radiochromatography

Charge readout and double phase

He-3 Neutron Detectors

200 kpa On-Chip Temperature. Compensated Silicon Pressure Sensors. MPX2200 Series. Pressure. Application Examples. Features. MPX2200 Rev 13, 10/2008

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Cryogenic Instrumentation I Thermometry OUTLINE Thermometry Pt (pure metal) Temperature Ranges of Thermometer Application Typical Resistive Thermal

The CUTE Facility. Ryan Underwood Queen s University, TRIUMF WNPPC 2019

MARINELLI BEAKERS CATALOG

Design, Construction, Operation, and Simulation of a Radioactivity Assay Chamber

The Advanced Gamma Tracking Array detector characterisation

RoHS. Versatile. X g. X 2 e

E2T0 DVP

Cryostat Assembly. 17 September Martin Nordby, Rafe Schindler, Gary Guiffre, Rick Van Berg

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P320-3 umodule SPOT PHASED OUT 46,5 39,5 35,5 NTC NTC LED + LED 8,5 4,5 8,5

PHASED OUT. LED light engine / OLED LED compact. Module SLE G4 6mm R SNC, SLE G4 10mm R SNC China domestic Modules SLE ESSENCE

Resistivity vs. Temperature of a Superconductor WARNING

System design of 60K Stirling-type co-axial pulse tube coolers for HTS RF filters

arxiv:nucl-ex/ v1 4 Jan 2007

The intense, pulsed positron source EPOS at the Research Centre Dresden-Rossendorf

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Old Dominion University Physics 112N/227N/232N Lab Manual, 13 th Edition

HiPace 300 with TC 400, DN 100 CF-F

Experimental Searches for Neutrinoless Double-Beta Decays in 76-Ge Alan Poon

THE COMPTON EFFECT Last Revised: January 5, 2007

Low Drift, Low Power Instrumentation Amplifier AD621

MAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features

Transcription:

Excellent energy resolution in the 3 to 300 kev range Active area from 30 to 00 2 PopTop flexibility Unequaled timing performance Detectors larger than 36- diameter available Available with special feedback resistor for high-rate applications POF preamplifier option for superior energy resolution and high count rate at low energies The ORTEC GLP Series Planar Low-Energy Photon Spectrometer (LEPS) is a small-area, highpurity germanium photon spectrometer for use in applications over the energy range from 3 to ~300 kev. Available in diameters from 6 to 36, the LEPS offers exceptional energy resolution for low and intermediate energies. At low energies in nuclear structure physics GLP detectors are irreplaceable because of their excellent timing performance (see Table 1). A cross sectional drawing of a 16- LEPS is shown in Figure 1. The Following Specifications are Provided for Each Model GLP Detector Active crystal diameter and depth. Energy resolution at 5.9 kev photons from 55 Fe at optimum shaping time unless the window material prohibits this energy. Energy resolution at 122 kev photons from 57 Co at optimum shaping time. Configuration Guidelines PopTop or Streamline (non-poptop) Configuration The essence of a PopTop detector system is that the HPGe detector element, preamplifier, and high voltage filter are housed in a detector capsule which is then attached to an appropriate cryostat (Figure 2.) In so called Streamline systems, the detector capsule is NOT demountable. Detector capsule and cryostat share the same vacuum. In configuration terms, this requires a cryostat or cryostat/dewar selection with the cryostat having a matching diameter to the capsule endcap. A cryostat must always be ordered with a Streamline capsule, because they are integral. The actual PopTop capsule has its own vacuum. It can be mounted on any of the available cryostats, cryostat/dewar combinations, or the -COOLER III mechanical cooling system. Fig. 1. 16- Diameter, - Deep GLP Detector. Table 1. Timing at Low Energies with cm 2 Active Area Planar Detectors*. Source Energy (kev) Time Resolution(ns) 22 Na 20 ± 0 ± 511 ±5 20 ±2 8.5 ±1 4.5 ±0.2 133 Ba 31 ±3 81 ±3 85 ±5 356 ±5 152 Eu 41 ±3 122 ±5 125 ±5 344 ±5 779 ±5 19 ±2 Isomer 11 ±1 6.0 ±0.5 15 ±1 Isomer 6.5 ±0.5 5.0 ±0.2 3.8 ±0.3 *Data courtesy of Dr. Kim Lister, Argonne National Lab. Fig. 2. Diagram of PopTop Detector.

Steps to Configure Your ORTEC HPGe Detector 1) Configure the Detector Model Capsule type (PopTop or Streamline) Crystal dimensions and specifications Endcap and window Mount Preamplifier Cable Package Options are available for the detector model that can change specific materials used in the construction of the detector endcap, cup, and mount. Preamplifier options are also available. 2) Configure the Cryostat/Dewar Model Vertical Dipstick style (separate Dewar or Mobius Recycler) Horizontal Dipstick style (separate Dewar or Mobius Recycler) Portable with all-position or multi-position cryostat/dewar models Downlooking designed to be oriented with the detector pointing down Sidelooking designed to be oriented with the detector horizontal at the bottom of the dewar SJ configuration designed with the detector attached near the bottom of the dewar and a right angle bend in the cryostat orienting the detector to look up. A cryostat and dewar or other cooling device are required for operation. If a PopTop detector has been selected, you can choose a PopTop style cryostat, cryostat/dewar combination or the -COOLER III mechanical cooling system. If a Streamline detector has been selected, you must choose a cryostat or cryostat/dewar model for the detector to be mounted on and vacuum sealed. The cryostat or cryostat/dewar combination diameter must match the endcap diameter of the selected detector. Detector Options SMART-1 Option (-SMN) The SMART-1 option monitors and reports on vital system functions, and can save authentication codes and report the code at a later time. It has the high voltage included, so none of the instruments require an external highvoltage power supply. The SMART-1 is housed in a rugged ABS molded plastic enclosure and is permanently attached to the detector endcap via a molded-strain-relieved sealed cable. This eliminates the possibility that the detector will suffer severe damage from moisture leaking into high-voltage connectors. The SMART-1 can be positioned in any convenient place and does not interfere with shielding or other mounting hardware. SMART-1 Detector Interface Module. Defining the Detector Model Base Model (example) GLP-06165/05 PopTop or Streamline P4 (PopTop) (Streamline) High Voltage Option (if required) -SMN 2

Streamline Detector Capsule Electronic Shroud Preamplifier default is Resistive Feedback -SMN changes to SMART-1 with HV Collimator default is Al Preamplifier Outside Vacuum Preamplifier Front End Window default is Be High Voltage Filter Ge Crystal Mount default is Cu Endcap default is Al PopTop Detector Capsule Electronic Shroud Preamplifier default is Resistive Feedback -SMN changes to SMART-1 with HV Collimator default is Al Preamplifier Outside Vacuum Preamplifier Front End Window default is Be PopTop Cold Finger Coupling High Voltage Filter Ge Crystal Mount default is Cu Endcap default is Al 3

Streamline Cryostat and Cryostat/Dewar Assemblies Streamline systems (detector capsule and cryostat) share the same vacuum, requiring a cryostat or cryostat/dewar selection with the cryostat having a matching diameter to the capsule endcap. Thermal Element Diameter must match Endcap Diameter - Diameter must match Endcap Diameter - Thermal Element Standard Dewars are DWR- 7.5D, 13D, or 30D Standard Cryostat uses Molecular Sieve Pumping Agent. Standard Cryostat uses Molecular Sieve Pumping Agent. Standard Dewars are DWR-1.2G, 3.0G, 5.0G, MOD- 3L, MOD-7L or 0.7- SHP-1 Standard Cryostat uses Molecular Sieve Pumping Agent. Optional Dewars are DWR-30, DWR-30-OP and MOBIUS-ST Thermal Element CFG-LP-GG CFG-LP-SV Diameter must match Endcap Diameter - CFG-LP-SD Thermal Element Diameter must match Endcap Diameter - Standard Dewars are DWR-7.5B, 13B, 30B, and MOBIUS-B Diameter must match Endcap Diameter - Thermal Element Standard Dewars are DWR-7.5B, 13B, 30B and MOBIUS-B Standard Cryostat uses Molecular Sieve Pumping Agent. Standard Cryostat uses Molecular Sieve Pumping Agent. CFG-LP-SJ CFG-LP-SL Thermal Element Standard Cryostat uses Molecular Sieve Pumping Agent. Optional Dewars are DWR-30, DWR-30-OP and MOBIUS-ST Diameter must match Endcap Diameter - CFG-LP-SH 4

PopTop and Streamline Dimensional Data Streamline systems (detector capsule and cryostat) share the same vacuum, requiring a cryostat or cryostat/dewar selection with the cryostat having a matching diameter to the capsule endcap. A cryostat must be ordered with a Streamline capsule. The PopTop capsule features an internal vacuum arrangement. It can be mounted on any of the available PopTop cryostats, cryostat/dewar combinations, or the -COOLER III mechanical cooling system. The cryostat and dewar drawings that follow are to be used in conjunction with the accompanying tables of dimensions. Note: Cryostat/Dewar drawings are NOT to scale, see tables that follow for complete dimensions. Dimensions are for reference only and subject to change, if dimensional constraints are critical, contact the factory. CFG-LP-SV, DWR-30 CFG-PV4, DWR-30 CFG-LP-SH, DWR-30 CFG-LP-SV, MOBIUS-ST CFG-PV4, MOBIUS-PT CFG-LP-SH, MOBIUS-ST 5

Note: Cryostat/Dewar drawings are NOT to scale, see tables that follow for complete dimensions. Dimensions are for reference only and subject to change, if dimensional constraints are critical, contact the factory. CFG-PH4, DWR-30 CFG-PH4, MOBIUS-PT CFG-LP-SJ, DWR-30B (or -13B or -7.5B) CFG-LP-SJ, MOBIUS-B CFG-PS4-30 (or -13 or -7.5) or CFG-LP-SL, DWR-30B (or -13B or -7.5B) CFG-PS4-MOBIUS-B or CFG-LP-SL, MOBIUS-B 6

Note: Cryostat/Dewar drawings are NOT to scale, see tables that follow for complete dimensions. Dimensions are for reference only and subject to change, if dimensional constraints are critical, contact the factory. CFG-LP-SH, DWR-30-OP CFG-PH4, DWR-30-OP CFG-PD4-30 (or -13 or -7.5) or CFG-LP-SD, DWR-30D (or -13D or -7.5D) CFG-PSHP4 or CFG-LP-GG, DWR-0.7-SHP-1 7

Note: Cryostat/Dewar drawings are NOT to scale, see tables that follow for complete dimensions. Dimensions are for reference only and subject to change, if dimensional constraints are critical, contact the factory. CFG--COOL-III GLP Detector Dimensions Dimensions are for reference only and subject to change. If dimensional constraints are critical, contact the factory. Dim. Unit Tol. PopTop Streamline A B C D E EM F J L M N 0.3 (0.01) 0.3 (0.01) 5 (0.2) 8 (0.3) 8 (0.3) 9 (0.35) 18 (0.7) (0.4) 18 (0.7) (0.4) 8 (0.3) (2.75) 75 (2.95) 135 (5.3) 250 (9.8) 947 (37.3) 948 (37.3) 396 (15.6) 338 (13.3) 790 (31.1) 278 (.9) (2.75) 75 (2.95) 71 (2.8) 182 (7.2) 854 (33.6) 855 (33.7) 305 (12.0) 318 (12.5) 274 (.8) 215 (8.5) 8

CFG-PG4-1.2 (or -3 or -5) or CFG-LP-GG, DWR-1.2G (or -3.0G, -5.0G) DWR-S/F CFG-PMOD4-3 (or -7) or CFG-LP-GG, DWR-MOD3L (or -MOD7L) Gaa Gage and Side-Looking Dewar Dimensions Dimensions are for reference only and subject to change. If dimensional constraints are critical, contact the factory. CFG-PG4 and DWR-x.xG Cryostat/Dewar or Dewar Type CFG-PMOD4 and DWR-MOD-xL CFG-PS4, CFG-PD4, DWR-xxB and DWR-xxD VOLUME VOLUME VOLUME Dim. UNIT TOL. ± 1.2L 3L 5L 3L 7L 7.5L 13L 30L Q S T Y Z 13 (0.5) 7.6 (0.3) 5 (0.2) 13 (0.5) 5 (0.2) 229 (9.0) 157 (6.2) 229 (9.0) 302 (11.9) 229 (9.0) 267 (.5) 302 (11.9) 229 (9.0) 419 (16.5) 229 (9.0) 157 (6.2) 292 (11.5) 302 (11.9) 229 (9.0) 320 (12.6) 77 (3.0) (0.4) 224 (8.8) 452 (17.8) 77 (3.0) (0.4) 307 (12.1) 429 (16.9) 60 (2.3) 13 (0.5) 442 (17.4) 6 (24.0) 9

Example Model Numbers Streamline Configuration GLP-06165/05 CFG-LP-GG- DWR-1.2G GLP-36385/ CFG-LP-SD- DWR-7.5D GLP-16195/-SMN CFG-LP-SV- DWR-30 6- diameter, 5- deep GLP planar detector with - diameter endcap. Portable Gaa Gage cryostat with matching - diameter flange. 1.2 liter all-position dewar for Gaa Gage cryostat. 36- diameter, - deep GLP detector with - diameter endcap. Downlooking cryostat with matching - diameter flange. 7.5 Liter downlooking dewar for downlooking cryostat. 16- diameter, - deep GLP detector with - diameter endcap and SMART-1 preamplifier and high voltage supply. Vertical dipstick style cryostat with matching - diameter flange. 30 liter top port dewar that accepts dipstick style cryostats. PopTop Configuration GLP-36360/13P4-SMN CFG-PG-3 GLP-180/07P4 CFG-PD4-7.5 GLP-06165/05P4 CFG-PH4 MOBIUS-PT 36- diameter, 13- deep GLP detector with - diameter endcap and SMART-1 preamplifier and high voltage supply. Portable Gaa Gage cryostat with 3 liter all-position dewar. - diameter, 7- deep GLP detector with - diameter endcap. Downlooking cryostat with 7.5 liter dewar. 6- diameter, 5- deep GLP planar detector with - diameter endcap. Horizontal Dipstick type cryostat. Möbius Recycler.

GLP Series Planar HPGe Low-Energy Detector Ordering Information For Streamline, remove the P4 from the model number. If dimensional considerations are critical, contact factory. Cryostat and dewar or other cooling device are not included with detector. Cryostat and dewar or other cooling device are required for operation. A cryostat must be ordered with a Streamline detector. Active Diameter Model No. () GLP-06165/05P4 6 GLP-180/07P4 GLP-16195/P4 16 GLP-25325/P4 25 GLP-25300/13P4 25 GLP-32355/P4 32 GLP-32340/13P4 32 GLP-36385/P4 36 GLP-36360/13P4 36 GLP Detector Options -SMN Dimensions Area ( 2 ) Depth () @5.9 kev (ev) 28 5 165 80 7 180 200 205 500 325 500 13 300 800 355 800 13 340 00 385 00 13 360 Energy Resolution FWHM SMART-1 detector option for negative bias detector, add -SMN to the model number. @122 kev (ev) 480 485 525 550 545 580 5 595 585 Endcap Diameter () Be Window Thickness () 0.13 0.13 0.13 0.25 0.25 0.25 0.25 0.25 0.25 GLP PopTop Cryostats and Dewars Model No. Description CFG-PD4-7.5 Down-looking Cryostat with 7.5-liter Dewar CFG-PD4-13 Down-looking Cryostat with 13-liter Dewar CFG-PD4-30 Down-looking Cryostat with 30-liter Dewar CFG-PG4-1.2 Gaa Gage Cryostat with 1.2-liter Dewar CFG-PG4-3 Gaa Gage Cryostat with 3-liter Dewar CFG-PG4-5 Gaa Gage Cryostat with 5-liter Dewar CFG-PH4 Horizontal Cryostat (Dipstick type). Choose DWR-30, DWR-30-OP, MOBIUS-PT or MOBIUS-PT-DET. CFG-PMOD4-3 Gaa Gage Cryostat with 3-liter Multi-Orientation Dewar CFG-PMOD4-7 Gaa Gage Cryostat with 7-liter Multi-Orientation Dewar CFG-PS4-7.5 Side-Looking Cryostat with 7.5-liter Dewar CFG-PS4-13 Side-Looking Cryostat with 13-liter Dewar CFG-PS4-30 Side-Looking Cryostat with 30-liter Dewar CFG-PS4-MOBIUS-B Side-Looking Cryostat with Möbius Recycler 28-liter Dewar CFG-PS4-MOBIUS-B-DET Side-Looking Cryostat with Möbius Recycler 28-liter Dewar for purchase in combination with PopTop detector. CFG-PSHP4 Down-Looking Shallow-Hole Probe with 0.7-liter Dewar CFG-PV4 Vertical Cryostat (Dipstick type). Choose DWR-30, DWR-30-OP, MOBIUS-PT or MOBIUS-PT-DET. MOBIUS-PT Möbius Recycler. MOBIUS-PT-DET Möbius Recycler 28-liter Dewar for purchase in combination with PopTop detector and vertical or horizontal dipstick cryostat. DWR-30 30-liter Dewar DWR-30-OP 30-liter Offset-Port Dewar DWR-S/F Storage Fill Dewar for CFG-PG4- CFG--COOL-III-115 -COOLER III with PopTop connector using 1-120 V ac, 60 Hz Input Power CFG--COOL-III-230 -COOLER III with PopTop connector using 220-240 V ac, 50 Hz Input Power 11

GLP Series Planar HPGe Low-Energy Detector GLP Streamline Cryostats Dewar required. Select dewar from GLP Streamline Dewars. Model No. Description CFG-LP-GG- Gaa Gage Cryostat CFG-LP-SD- Down-Looking Cryostat CFG-LP-SH- Horizontal Cryostat (Dipstick type). CFG-LP-SJ- J-type Cryostat CFG-LP-SL- Side-Looking Cryostat CFG-LP-SV- Vertical Cryostat with (Dipstick type). GLP Streamline Dewars For Cryostat Choose Description CFG-LP-GG DWR-1.2G 1.2-liter All-Orientation Dewar DWR-3.0G 3.0-liter All-Orientation Dewar DWR-5.0G 5.0-liter All-Orientation Dewar DWR-MOD-3L 3-liter Multi-Orientation Dewar DWR-MOD-7L 7-liter Multi-Orientation Dewar DWR-0.7-SHP-1 0.7-liter Shallow-Hole Probe Dewar DWR-S/F Storage/Fill Dewar for DWR-G CFG-LP-SJ, SL DWR-7.5B 7.5-liter Side-Looking Dewar DWR-13B 13-liter Side-Looking Dewar DWR-30B 30-liter Side-Looking Dewar MOBIUS-B Möbius Recycler 28-liter Side-Looking Dewar CFG-LP-SD DWR-7.5D 7.5-liter Down-Looking Dewar DWR-13D 13-liter Down-Looking Dewar DWR-30D 30-liter Down-Looking Dewar CFG-LP-SV, SH DWR-30-OP 30-liter Offset-Port Dewar DWR-30 30-liter Dewar MOBIUS-ST Möbius Recycler 28-liter Dewar for purchase stand alone MOBIUS-ST-DET Möbius Recycler 28-liter Dewar for purchase in combination with Detector Specifications subject to change 080417