Blind Measurements and Precision Muon Physics. David Hertzog University of Washington

Similar documents
Fundamental Symmetries III Muons. R. Tribble Texas A&M University

The MuLan Experiment

± 1 10 part-per-million precision

The MuLan Experiment

Muon g 2. Physics 403 Advanced Modern Physics Laboratory Matthias Grosse Perdekamp. Slides adapted from Jörg Pretz RWTH Aachen/ FZ Jülich

The Tiny Muon versus the Standard Model. Paul Debevec Physics 403 November 14 th, 2017

Muon storage for the muon g-2 experiment at Fermilab

10th International Workshop on Neutrino Factories, Super beams and Beta beams June 30 - July Valencia, Spain

The MuLan Experiment: Measuring the muon lifetime to 1 ppm


Precision Muon Capture on the Proton and Very Light Nuclei

Measurement of Muon Dipole Moments

Final Results of the Muon g-2 Experiment at BNL

A new method of measuring the muon g-2. Francis J.M. Farley Trinity Co!eg" Dubli#

Electroweak Physics: Lecture V

Lee Roberts Department of Physics Boston University

This image is brought to you by: Fermilab's Visual Media Services

The Mu3e PSI

PSI. Muon Experiment at the PSI, KEK

New Physics with a High Intensity PS (in Italy)

D.H. Ryan. Centre for the Physics of Materials and Physics Department, McGill University, Montreal, Quebec CANADA

ν ν Relative Intensity 53 MeV Electron energy

Observation of a New Particle with a Mass of 125 GeV

The Factors That Limit Time Resolution for Photon Detection in Large Cherenkov Detectors

THE MUON ANOMALOUS MAGNETIC MOMENT: A PROBE FOR THE STANDARD MODEL AND BEYOND A REPORT SUBMITTED TO THE GRADUATE FACULTY

Elementary Particle Physics Glossary. Course organiser: Dr Marcella Bona February 9, 2016

Chapter 16. The ω a Measurement Measurement Overview

The Mu3e PSI

Building IBMS Detectors for Muon g-2

EXPERIMENTAL RESULTS AND THEORETICAL DEVELOPMENTS OF MUON g-2. H. Deng, on behalf of Muon (g 2) Collaboration University of Pennsylvania

Physics 736. Experimental Methods in Nuclear-, Particle-, and Astrophysics. - Accelerator Techniques: Introduction and History -

Overview of the COMET Phase-I experiment

The (anomalous) Magnetic Moment of the Muon

Lifetime and Dipole Moments

Beam at the Paul Scherrer Institut

MuSIC- RCNP at Osaka University

Outline. He Magnetometry for g 2. Babak Abi Oxford - 28April

β and γ decays, Radiation Therapies and Diagnostic, Fusion and Fission Final Exam Surveys New material Example of β-decay Beta decay Y + e # Y'+e +

Marcos Dracos IPHC, Université de Strasbourg, CNRS/IN2P3, F Strasbourg, France

NMR BMB 173 Lecture 16, February

arxiv: v1 [physics.ins-det] 26 Sep 2018

Shimming of a Magnet for Calibration of NMR Probes UW PHYSICS REU 2013

Lecture 8. CPT theorem and CP violation

Mu2e: Coherent μ e Conversion Experiment at Fermilab. David Brown, LBNL representing the mu2e collaboration

Muon Experiments. Masaharu Aoki, Osaka University. NP02 International workshop on Nuclear and Particle Physics at 50-GeV PS Kyoto

Fundamental MRI Principles Module 2 N. Nuclear Magnetic Resonance. X-ray. MRI Hydrogen Protons. Page 1. Electrons

Precision Muon Capture at PSI

The New Search for a Neutron EDM at the SNS

The Collider Detector at Fermilab. Amitabh Lath Rutgers University July 25, 2002

Masaharu Aoki Osaka University

The Lamb shift in hydrogen and muonic hydrogen and the proton charge radius

Intense Slow Muon Physics

RICH detectors for LHCb

The n- 3 He Experiment at SNS A Study of Hadronic Weak Interaction

Outline. Charged Leptonic Weak Interaction. Charged Weak Interactions of Quarks. Neutral Weak Interaction. Electroweak Unification

R. P. Redwine. Bates Linear Accelerator Center Laboratory for Nuclear Science Department of Physics Massachusetts Institute of Technology

Chapter 32 Lecture Notes

MUSEing on the Proton Radius Puzzle. W.J. Briscoe and E.J. Downie

PoS(ICHEP2016)552. The Mu3e Experiment at PSI. Alessandro Bravar University of Geneva

PHY 599: How it is usually done

The Proton Radius: Are We Still Puzzled? E. J. Downie

Fundamental MRI Principles Module Two

Exam Results. Force between charges. Electric field lines. Other particles and fields

How and Why to go Beyond the Discovery of the Higgs Boson

arxiv: v1 [physics.ins-det] 1 Sep 2009

Paul Huffman! Investigating Hadronic Parity Violation Using the γd np Reaction at the Proposed HIGS2 facility at TUNL

Today: Part I: Neutrino oscillations: beam experiments. Part II: Next tutorials: making distributions with histograms and ntuples

(Lifetime and) Dipole Moments

Measurement of e + e hadrons cross sections at BABAR, and implications for the muon g 2

Text. References and Figures from: - Basdevant et al., Fundamentals in Nuclear Physics - Henley et al., Subatomic Physics

Measurement of Nucleon Strange Form Factors at High Q 2

Chapter 7. Nuclear Magnetic Resonance Spectroscopy

PoS(NOW2016)003. T2K oscillation results. Lorenzo Magaletti. INFN Sezione di Bari

Neutron spin filter based on dynamically polarized protons using photo-excited triplet states

PoS(EPS-HEP2017)238. Experimental limiting factors for the next generation

6-8 February 2017 Hotel do Mar Sesimbra. Hands on Neutrinos

Standard Model Theory of Neutron Beta Decay

Recent Results from T2K and Future Prospects

Sub-Doppler two-photon laser spectroscopy of antiprotonic helium and the antiproton-toelectron

clfv searches using DC muon beam at PSI

Why a muon collider?

SUPPLEMENTARY INFORMATION

Muon to Electron Conversion: Experimental Status in Japan and the US

EXPLORING PARTICLE-ANTIPARTICLE ASYMMETRY IN NEUTRINO OSCILLATION. Atsuko K. Ichikawa, Kyoto University

Effective Lab Oral Report Fall 2018

OUTLINE. CHARGED LEPTONIC WEAK INTERACTION - Decay of the Muon - Decay of the Neutron - Decay of the Pion

In Pursuit of Discovery at The Large Hadron Collider

The ESS neutrino facility for CP violation discovery

Geant4 simulations of the lead fluoride calorimeter

Lee Roberts Department of Physics Boston University

Subatomic Physics Research at UBC

High Pressure, High Gradient RF Cavities for Muon Beam Cooling

PoS(ICHEP2016)293. The LArIAT experiment and the charged pion total interaction cross section results on liquid argon. Animesh Chatterjee

The Gamma Factory proposal for CERN

Muons in Chemistry Training School Dr N J Clayden School of Chemistry University of East Anglia Norwich

The Mu3e Experiment - Goal

Measurement of W-boson Mass in ATLAS

- ~200 times heavier than the e GeV µ travels on average. - does not interact strongly. - does emit bremsstrahlung in

DEVELOPMENT OF A DATA ACQUISITION SYSTEM FOR THE MUON g-2 EXPERIMENT AT FERMILAB

Parity-violating Electron Scattering and Strangeness in the Nucleon: Results from HAPPEX-II

Transcription:

Blind Measurements and Precision Muon Physics David Hertzog University of Washington

A word about the Evolution of Precision Time "our future discoveries must be looked for in the sixth place of decimals." MuLan It follows that every means which facilitates accuracy in measurement is a possible factor in a future discovery, and this will, I trust, be a sufficient excuse for bringing to your notice the various methods and results which form the subject matter of these lectures. - Albert Abraham Michelson- MuCap New g-2 MuSun

An unusual subatomic particle Mass ~ 207 m e : heavy electron Lifetime ~2.2 ms is long: beams, probes m - can form 1-electron hydrogen-like atoms m - p, m - d, m - A Muonium: m - e + Primary decay m + e + n e n m (parity violation) Easily polarized: p + m + n m n p + m + Typically 42,000 times more sensitive to new physics quantum loops compared to electrons ~(m m /m e ) 2 Lepton number conservation: No m e conversion p m -

First: The case for going blind Taste tests Medical Trials This is not new stuff So, why is it novel in physics?

Precision measurements have a checkered history. You stop analyzing when you agree with the current world average

As we know

World avg dt m /t m is 18 ppm, but is it right? Lessons from History m+ Neutron Lifetime Precision vs Accuracy 10 ±1 ppm? Goal of MuLan is 1 ppm. But, how did we get this far??

First the blinding story from our Muon g-2 Experiment e Momentum Spin μ -10 a Expt. =11659208.0 6.3 10 0.54 ppm

The stakes are high In discovery physics 3.6 s standard deviations) is not enough. That s called a hint of something Note: 3 s is 99.7% probability of being right, so go figure The Standard Model Our Experiment The Fear is BIAS and Errors

We measure (1) Precession frequency TIME (2) Muon distribution (3) Magnetic field map B g 2 1 2 3

BNL Storage Ring Quads

Fit is sophisticated, but looks like this N(t) = N 0 e -t/t [1+Acos(w a t + f)] Billions of events so getting a good fit is difficult but mandatory Magnetic Field uncertainty is purely systematic -- alignment -- absolute calibrations -- db/dx at measurement -- probe signal quality Field measured in terms of proton NMR in SAME magnet

A double-blind analysis culture Field and Precession are frequency measurements which employ clocks Offsets are added to intermediate analysis results that are shared with others Nobody knows the offsets from the field and the precession analyses Nobody can divide them to obtain a physics result All consistency plots, fits, etc, can be performed without bias When analyses are stable, reveal secret offsets, divide, and publish Magnetic Field Secret Offsets Secret Offsets My Team My Team Data Production BU Yale One year, we published two days after the unblinding.

Examples of Self Consistency of Measurements 14 Individual analyses independent and consistent Bennett et al, PRD 73, 072003 (2006) Different techniques (same data)

Let s do it again even better

New Muon Campus at Fermilab

But we have to move the ring from New York to Chicago 17

Requires rather special engineering! Go the long way, but hope to avoid hurricane season ust passes through Illinois tollway by a few inches

The task has begun: BNL to FNAL

Muon Lifetime Weak Interaction Strength (Now I will describe our most recent measurement) G F Muon decay is a pure weak process determines G m, often called G F

Paul Scherrer Institut Villigen, Switzerland msr Neutrons SINQ 2.2 ma cyclotron, 590 MeV protons Swiss Light Source

PSI: a 1.3 MW facility with many secondary muon beams. Example: pe3 beamline at PSI MuSun MuCap MEG MuLan PiBeta + new p/m area Lamb shift below

t m + determined Fermi Constant to unprecedented precision t m + needed for reference lifetime for precision muon capture experiments MuCap g P MuLan Motivation G F a M Z 9 ppm 0.37 ppb 23 ppm 0.6 ppm Capture rate from lifetime difference m and m + MuSun L 1A Is lifetime in bound muonium the same as the free lifetime?

G F & t m precision has improved by ~4 orders of magnitude over 60 years. Achieved!

Number (log scale) The experimental concept Real data Kicker On e + Measurement Period 170 of these time Fill Period

The complete detector has 30 active houses, with 170 tile pairs e + 80 pe/mip

In beam, backed off

MuLan collected two datasets, each containing 10 12 muon decays Ferromagnetic Target, 2006 Quartz Target, 2007 Two (very different) data sets Different blinded clock frequencies used Revealed only after all analyses of both data sets completed Most systematic errors are common

Easy to blind this kind of measurement Everything runs off a super-high precision, stable oscillator Adjust it to give 450 MHz but make a secret offset (of the oscillator) by ±200 ppm of central value [ done by someone outside collaboration ] Our analysis seconds are not real seconds but it doesn t matter until we are done Two different data sets with vastly different conditions Each has its own offset When we think we are ready, map BOTH to yet another blind space to see if we have internal consistency If we do, we can proceed to unblinding to real seconds space Two data sets agreed to better than 1 ppm so we are okay 29

Final Errors and Numbers ppm units Effect 2006 2007 Comment Kicker extinction stability 0.20 0.07 Voltage measurements of plates Upstream muon stops 0.10 0.10 Upper limit from measurements Overall gain stability: 0.25 0.25 MPV vs time in fill; includes: Short time; after a pulse MPVs in next fill & laser studies Long time; during full fill Different by PMT type Electronic ped fluctuation Bench-test supported Unseen small pulses Uncorrected pileup effect gain Timing stability 0.12 0.12 Laser with external reference ctr. Pileup correction 0.20 0.20 Extrapolation to zero ADT Residual polarization 0.10 0.20 Long relax; quartz spin cancelation Clock stability 0.03 0.03 Calibration and measurement Total Systematic 0.42 0.42 Highly correlated for 2006/2007 Total Statistical 1.14 1.68 t(r06) = 2 196 979.9 ± 2.5 ± 0.9 ps t(r07) = 2 196 981.2 ± 3.7 ± 0.9 ps t(combined) = 2 196 980.3 ± 2.2 ps (1.0 ppm) Dt(R07 R06) = 1.3 ps

Lifetime history FAST The most precise particle or nuclear or (we believe) atomic lifetime ever measured New G F G F (MuLan) = 1.166 378 8(7) x 10-5 GeV -2 (0.6 ppm)

Some recent Press

MuLan at PSI 2004 2007 2006

Conclusions Blind measurements can be very satisfying since you can t go back They can be very frustrating because you can t go back They can also make you take MUCH longer before you think you have really checked everything