Application Note. Abstract. Authors. Environmental

Similar documents
PAH Analyses with High Efficiency GC Columns: Column Selection and Best Practices

A Direct 5 ms Column Performance Comparison for Active Semi-Volatile Analytes

Semivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column

Rely on Rxi -PAH Columns

The Use of Tandem Quadrupole GC/MS/MS for the Determination of Polycyclic Aromatics Hydrocarbons (PAHs) in Food Products

Determination of 24 PAHs in Drinking Water

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

ENVIRONMENTAL analysis

Application Note. Abstract. Authors. Introduction. Food Safety

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Author. Abstract. Introduction

Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Seafood Using GC/MS

Challenging Pesticide Analysis Using an Agilent J&W DB-35ms Ultra Inert GC Column

Selection of a Capillary GC Column

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS

Analysis of Natural Oils and Extracts Using the Low Thermal Mass LTM Series II System

Ultra-Inert chemistry for Trace Level Analysis

Analysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Rapid Analysis of Food and Fragrances Using High-Efficiency Capillary GC Columns. Application. Authors. Abstract. Introduction

Selection of a Capillary

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Highly Sensitive and Rugged GC/MS/MS Tool

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

Agilent UltiMetal Plus Stainless Steel Deactivation for Tubing, Connectors, and Fittings

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Understanding Gas Chromatography

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Introduction to Capillary GC

Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution

Sensitive and rapid determination of polycyclic aromatic hydrocarbons in tap water

Evaluation of Capillary Columns for General Performance Parameters

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

British American Tobacco Group Research & Development. Method - Determination of phenols in mainstream cigarette smoke

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

CALIBRATION OF GC/MS METHOD AND VALIDATION OF THE MODIFIED SAMPLE PREPARATION FOR DETERMINATION OF POLYCYCLIC AROMATIC HYDROCARBONS

Developing Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Reliably measure trace-level contaminants and meet regulatory requirements with confidence

This project has been funded with support from the European Commission. This publication reflects the views only of the authors, and the Commission

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

Application Note. Abstract. Authors. Introduction

Enhanced Sensitivity for Biomarker Characterization in Petroleum Using Triple Quadrupole GC/MS and Backflushing

Applying the Agilent 5977A MSD to the Analysis of USP<467> Residual Solvents with the 7697A Headspace Sampler and 7890B GC

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source

The Suite for Environmental GC Analysis

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

Fast Analysis of USP 467 Residual Solvents using the Agilent 7890A GC and Low Thermal Mass (LTM) System

Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns

Report on the third inter-laboratory comparison test organised by the Community Reference Laboratory for Polycyclic Aromatic Hydrocarbons

Fast and Accurate Analysis of PBDEs in a Single Run, Including BDE-209

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

Fast and Accurate Analysis of PBDEs in a Single Run, Including

The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application

So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist

Introduction to Capillary GC

Optimization of 1,4-Dioxane and Ethanol Detection Using USEPA Method 8260 Application Note

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

Trajan SGE GC Columns

UltiMetal Plus Advanced Chemistry for Stainless Steel Surface Deactivation

Signal, Noise, and Detection Limits in Mass Spectrometry

Pesticides Analysis Using the Agilent 5977A Series GC/MSD

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

CERTIFICATION REPORT. Certification of the Mass Fraction of Polycyclic Aromatic Hydrocarbons (PAHs) in Toluene

Application. Gas Chromatography March 1998

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Application. Gas Chromatography February Introduction

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

Application Note. Agilent Application Solution Analysis of PAHs in soil according to EPA 8310 method with UV and fluorescence detection.

Organophosphorus Pesticides in Apple Matrix by GC/MS/FPD using an Agilent J&W DB-35ms Ultra Inert GC Column

DIQUAT DIBROMIDE. The Determination of Ethylene Dibromide in Diquat Dibromide and Diquat Dibromide / Paraquat Dichloride SL Formulations

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

Method - Determination of aromatic amines in mainstream cigarette smoke

Agilent J&W PoraBOND Q PT Analyzes Oxygenates in Mixed C4 Hydrocarbon Streams by GC/FID and GC/MSD

STANDARD OPERATING PROCEDURES

Analysis of Terpenes in Cannabis Using the Agilent 7697A/7890B/5977B Headspace GC-MSD System

Method of determination of phtalates in spirituous beverages by gaschromatography/mass

USP<467> residual solvents

GC Analysis of Polybrominated Flame Retardants Application

Rapid, Robust, and Sensitive Detection of 11-nor-D 9 - Tetrahydrocannabinol-9-Carboxylic Acid in Hair

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Analysis of BTEX in Natural Water with SPME

Solid Phase Micro Extraction of Flavor Compounds in Beer

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

Transcription:

GC/MS Analysis of European Union (EU) Priority Polycyclic Aromatic Hydrocarbons (PAHs) using an Agilent J&W DB-EUPAH GC Column with a Column Performance Comparison Application Note Environmental Authors Doris Smith and Ken Lynam Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19808 USA Abstract Recent European legislation has established a list of polycyclic aromatic hydrocarbons (PAHs) to be monitored in foods. These target PAHs can prove chromatographically problematic with non-polar GC columns typically used for the analysis of US EPA priority PAHs. This application demonstrates a GC/MS method for the determination of the +1 European Union (EU) priority PAHs using the application-specific Agilent J&W DB-EUPAH GC column. This column provided baseline resolution for critical pairs and excellent sensitivity for the heavier PAHs. In addition, DB-EUPAH showed improved bleed performance and better signal-to-noise ratios when compared to a Restek Rxi-17 column. This resulted in more accurate quantitation especially for late eluting dibenzopyrenes.

Introduction Polycyclic aromatic hydrocarbons are a large class of organic compounds containing two or more fused aromatic rings. PAHs are often formed from the incomplete burning of organic substances such as wood, coal, and oil. A main source of human exposure to PAHs is food, through the heat processing of meat and dairy products, such as grilling and smoking [1]. Serious health concerns have arisen as many PAHs have been classified as carcinogenic or mutagenic [2]. Most current analytical methods focus on the sixteen PAHs the US Environmental Protecting Agency (EPA) targeted in the 1970s [3]. In 2005, the European Commission recommended the monitoring of fifteen EU priority PAHs along with an additional PAH highlighted by the Joint FAO/WHO Expert Committee on Food Additives (JECFA) [4]. These +1 EU priority PAHs include benzo[c]fluorene, benz[a]anthracene, cyclopenta[c,d]pyrene, chrysene, 5-methylchrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[j]fluoranthene, benz[a]pyrene, indeno[1,2,3-cd]pyrene, dibenz[a,h]anthracene, benzo[g,h,i]perylene, dibenzo[a,l]pyrene, dibenzo[a,e]pyrene, dibenzo[a,i]pyrene, and dibenzo[a,h]pyrene. Eight of these compounds (benz[a]anthracene, chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benz[a]pyrene, indeno[1,2,3-cd]pyrene, dibenz[a,h]anthracene, benzo[g,h,i]perylene) are also listed in the 16 USEPA-regulated PAH list. A 5% phenyl methylpolysiloxane stationary phase is the most commonly used GC column for PAH analysis. This non-polar column yields good resolution for the 16 USEPA PAHs [5,6], however, three critical pairs of the +1 EU PAHs co-elute and are difficult to resolve [7,8]. These challenging pairs are benz[a]anthracene-cyclopenta[c,d]pyrene- chrysene, benzo[b]fluoranthene-benzo[k]fluoranthene-benzo[j]fluoranthene, and indeno[1,2,3-cd]pyrene-dibenz[a,h]anthracene. Agilent J&W DB-EUPAH, a midpolar GC column, improves the resolution of these critical pairs allowing for more accurate detection and quantitation of the +1 EU priority PAHs. Another set of challenging analytes is the four dibenzopyrene isomers. Due to their high molecular weight (MW 302), these isomers are prone to discrimination and poor peak shape. Broad, tailing peaks make reliable quantitation difficult and decrease the signal to noise ratio, resulting in an increase in limits of detection. Deleterious chromatographic effects can be largely offset by limiting analyte dwell time on the column and in the GC/MS interface. Shorter columns with thinner film thickness and high operating temperatures are all factors that collectively can improve peak shapes for these analytes. A column comparison study was done to evaluate column performance of a DB-EUPAH column versus a Restek's Rxi-17 column. Since the competitor does not offer this column in a 0. µm film thickness, a 20 m 0.18 mm 0.18 µm column was the closest available for the evaluation. A standard containing the +1 EU priority PAHs was analyzed on each column to evaluate performance. Experimental An Agilent 6890N Network GC system and Agilent 5975B Series MSD equipped with an Agilent 7683B autosampler was used for this series of experiments. Table 1 lists the chromatographic conditions used for the analyses, and Table 2 lists the flow path consumable supplies. Table 1. Chromatographic Conditions for +1 EU Priority PAHs Standards GC: Agilent 6890N/5975B MSD Sampler: Agilent 7683B, 5.0 µl syringe (Agilent p/n 5181-1273) 0.5 µl splitless injection, injection speed 75 µl/min Carrier: Helium, ramped flow 1.0 ml/min (0.2 min), 5 ml/min 2 to 1.7 ml/min Inlet: 325 C splitless, purge flow 60 ml/min at 0.8 min Inlet Liner: Deactivated dual taper direct connect (Agilent p/n G44-80700) Column : Agilent J&W DB-EUPAH 20 m 0.18 mm 0. µm (Agilent p/n 121-9627) Oven: 45 C (0.8 min) to 200 C (45 C/min), 2.5 C/min to 225 C, 3 C/min to 266 C, 5 C/min to 300 C, 10 C/min to 320 C (4.5 min) Detection: MSD source at 300 C, quadrupole at 180 C, transfer line at 330 C, Scan range 50 550 AMU Column Performance Comparison Column 1: Agilent J&W DB-EUPAH 20 m x 0.18 mm x 0. µm (Agilent p/n 121-9627) Column 2: Restek Rxi-17 20 m 0.18 mm 0.18 µm Oven: 45 C (0.8 min) to 200 C (45 C/min), 2.5 C/min to 225 C, 3 C/min to 266 C, 5 C/min to 300 C, 10 C/min to 320 C (4.5 min) Table 2 Flow Path Supplies Vials: Amber crimp top glass vials (Agilent p/n 5183-4496) Vial Caps: Crimp caps (Agilent p/n 5181-1210) Vial inserts: 100 µl glass/polymer feet (Agilent p/n 5181-8872) Syringe: 5 µl (Agilent p/n 5181-1273) Septum: Advanced Green (Agilent p/n 5183-4759) Inlet liners: Deactivated dual taper direct connect (Agilent p/n G44-80700) Ferrules: 0.4 mm id short; graphite (Agilent p/n 500-21) 0.4 mm id short; preconditioned 85/ Vespel/graphite, long (Agilent p/n 5062-3508) 20x magnifier: 20x Magnifier loop (Agilent p/n 430-1020) 2

Sample Preparation A sixteen component EU PAH standard mix (Agilent p/n 5190-0487) served as a stock standard with a nominal concentration of 250 µg/ml per analyte. The working level standards were prepared with concentrations of 10, 5, 2, 1, 0.5, 0.2, and 0.1 µg/ml. All solutions were prepared in acetone using class A volumetric pipettes and flasks. JT Baker UltraResi grade acetone was used as a reagent blank and syringe wash solvent. Results and Discussion The 16-component EU regulated PAH standard mix was evaluated on an Agilent J&W DB-EUPAH 20 m 0.18 mm 0. µm (Agilent p/n 121-9627). Resolution of all sixteen PAHs was achieved in less than 43 min. An example chromatogram of the 2.5-ng on-column loading of the standard solution is shown in Figure 1. Baseline resolution was achieved on the DB-EUPAH column for all of the analytes included in the +1 EU PAH samples including three sets of critical pairs. Figure 1 highlights the resolution factors (R s ) for the three critical resolution pairs as calculated by the following formula [9]: R s = 1.18 * (T R2 T R1 ) (W h1 + W h2 ) Where T R1 = retention time of the first peak T R1 = retention time of the second peak W h1 = peak width at half height of the first peak W h2 = peak width at half height of the second peak Baseline resolution between benz[a]anthracene and cyclopenta[c,d]pyrene was achieved with an R s of 2.7 and R s value of 2.4 for cyclopenta[c,d]pyrene and chrysene. Benzo[j]fluoranthene is normally difficult to separate from the [b] and [k] isomers; therefore these analytes are frequently reported as a sum. However, baseline resolution was achieved for these challenging isomers with the DB-EUPAH column with Rs values of 1.7 and 1.6, respectively, allowing accurate quantitation of each isomer. A resolution value of 2.6 was obtained for the third critical pair, indeno[1,2,3-cd]pyrene and dibenz[a,h]anthracene. Figure 1 clearly demonstrates that the DB-EUPAH column can provide excellent sensitivity and selectivity for the analysis of EU regulated PAHs. Resolution of Critical Pairs on an Agilent J&W DB-EUPAH Column Abundance 000 000 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 1 Rs 2.4 Rs 2.7 4 2 3 5 Rs 1.6 Rs 1.7 6 7 8 9 10 11 10.00.00 20.00 25.00 30.00 35.00 40.00 Time Rs 2.6 12 16 EU-PAHs 1. Benzo[c]fluorene 2. Benz[a]anthracene 3. Cyclopenta[c,d]pyrene 4. Chrysene 5. 5-Methylchrysene 6. Benzo[b]fluoranthene 7. Benzo[k]fluoranthene 8. Benzo[j]fluoranthene 9. Benz[a]pyrene 10. Indeno[1,2,3-cd]pyrene 11. Dibenzo[a,h]anthracene 12. Benzo[g,h,i]perylene. Dibenzo[a,l]pyrene. Dibenzo[a,e]pyrene. Dibenzo[a,i]pyrene 16. Dibenzo[a,h]pyrene Figure 1. TIC of a 0.5 µl injection of 0.5 ng EU priority PAH standard solution on an Agilent J&W DB-EUPAH 20 m 0.18 mm, 0. µm capillary GC column (Agilent p/n 121-9672). Chromatographic conditions are listed in Table 1. 3

For the comparison study, columns from each vendor were analyzed under the same conditions on the same instrument. Example total ion chromatograms (TIC) of 2.5-ng on-column loading for both vendor columns are shown in Figure 2. While both columns were able to resolve the EU PAHs under the same conditions, the DB-EUPAH did so with a significantly lower bleed profile. The oven temperature program maximum was kept at 320 C to accommodate the isothermal limit of the Rxi-17 column, during the comparison study. The maximum isothermal temperature limit for the DB-EUPAH column is 340 C, 20 C higher. The Rxi-17 column shows significantly higher bleed than the DB-EUPAH even at 320 C, resulting in poorer signalto-noise ratios as shown in Figure 3. Figure 3 further illustrates the DB-EUPAH's superior sensitivity for the dibenzopyrenes at low levels by highlighting the signal-to-noise ratios of dibenzo[a,l]pyrene on both columns. The heavier dibenzopyrene isomers, in particular the [a,e], [a,i] and [a,h] isomers, were at the limit of reliable detection on the Rxi-17 column as a result of the higher bleed. Signal-to-noise ratios on the DB-EUPAH column are more than a factor of two better than those for the Rxi-17 because of its lower bleed. Column Comparison for +1 EU Priority PAHs Separation 18000 16000 000 DB-EUPAH 20 m 0.18 mm id 0. µm Abundance 12000 10000 8000 6000 4000 1 2 3 4 8 5 7 6 9 11 10 12 16 2000 0 10.00.00 20.00 25.00 30.00 35.00 40.00 Time Elution order Abundance 32000 28000 24000 20000 16000 12000 8000 4000 1 Rxi-17 20 m 0.18 mm id 0.18 µm 2 3 4 5 6 7 8 10 9 11 12 16 1. Benzo[c]fluorene 2. Benz[a]anthracene 3. Cyclopenta[c,d]pyrene 4. Chrysene 5. 5-Methylchrysene 6. Benzo[b]fluoranthene 7. Benzo[k]fluoranthene 8. Benzo[j]fluoranthene 9. Benz[a]pyrene 10. Indeno[1,2,3-cd]pyrene 11. Dibenzo[a,h]anthracene 12. Benzo[g,h,i]perylene. Dibenzo[a,l]pyrene. Dibenzo[a,e]pyrene. Dibenzo[a,i]pyrene 16. Dibenzo[a,h]pyrene 0 10.00.00 20.00 25.00 30.00 35.00 40.00 Time Figure 2. TIC of a 0.5 µl injection of the 0.5 µg/ml +1 EU priority PAH standard on Agilent J&W DB-EUPAH and Rxi-17 columns. Chromatographic conditions are listed in Table 1. 4

DB-EUPAH Lower Bleed at 320 C Means Better Signal-to-Noise Ratios 16 DB-EUPAH 20 m 0.18 mm id 0. µm Analyte S/N ratio. Dibenzo[a,l]pyrene 12.8. Dibenzo[a,e]pyrene 7.5. Dibenzo[a,i]pyrene 5.9 16. Dibenzo[a,h]pyrene 8.7 16 Rxi-17 20 m 0.18 mm id 0.18 µm Analyte S/N ratio. Dibenzo[a,l]pyrene 5.7. Dibenzo[a,e]pyrene 3.2. Dibenzo[a,i]pyrene 2.9 16. Dibenzo[a,h]pyrene 3.1 Figure 3. Overlaid TICs of 2.5 ng on-column loading injections of +1 EU priority PAH standard on Agilent J&W DB-EUPAH and Rxi-17. Chromatographic conditions are listed in Table 1. Conclusions This application demonstrates the use of an Agilent J&W DB-EUPAH capillary GC column for the analysis of +1 EU regulated PAHs. The 20 m 0.18 mm, 0. µm column dimension effectively separated the sixteen PAHs, resolving all the critical, difficult-to-separate pairs. The column offers further improvement on the quantitation of the heavier dibenzopyrenes due to the higher temperature limit and phase ratio as compared to the Restek Rxi-17 column. Excellent peak shapes and sensitivity were achieved for the target +1 EU priority PAHs. The results of a column performance comparison between Agilent J&W DB-EUPAH column and the Rxi-17 showed lower bleed for the DB-EUPAH column with better signal to noise ratios for late eluting dibenzopyrene isomers. The excess bleed for the Rxi-17 column at the higher temperatures make trace level detection difficult and unreliable for the four dibenzopyrene isomers. The DB-EUPAH column offers improved peak shape and sensitivity that translates to consistently lower detection limits, which makes it an excellent choice for the analysis of the EU priority PAHs. 5

References 1. P. Mottier, V. Parisod, R. J. Turesky, J. Agric. Food Chem. 48 (2000), p. 1160. 2. Y. V. Pashin and L. M. Bakhitova, "Mutagenic and Carcinogenic Properties of Polycyclic Aromatic Hydrocarbons," Environ Health Prospect, 30 (1979), p.185-9. 3. Environmental Proction Agency (EPA) of the United States of America, Compendium Method TO-A, EPA, Cincinnati, OH, USA, 1999. 4. European Union, Commission Recommendation 2005/108/EC, Off. J. Eur. Comm. L34 (2005) 43. 5. Frank David and Matthew S. Klee, "Fast Analysis of Polynuclear Aromatic Hydrocarbons using Agilent Low Thermal Mass (LTM) GC/MS and Capillary Flow Technology Quickswap for Backflush," Agilent Technologies publication 5990-3451EN, April 2009. 6. Kenneth Lynam and Doris Smith, "Polycyclic Aromatic Hydrocarbon (PAH) Analysis Using an Agilent J&W DB-5ms Ultra Inert Capillary GC Column," Agilent Technologies publication 5989-9181EN, July 2008. 7. R. Simon, S. Palme, E. Anklam, J. Chromatogr. A 2006, 1103, 307-3. 8. L. R. Bordajandi, M. Dabrio, F. Ulberth, H. Emons, J. Sep. Sci. 2008, 31, 1769-1778. 9. "The Troubleshooting and Maintenance Guide for Gas Chromatographers," Dean Rood, Wiley-VCH Verlag GmbH & CO., KGaA, Weinheim, page 26, 4th Edition, 2007. For More Information For more information on our products and services, visit our Web site at www.agilent.com/chem. www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., 2010 Printed in the USA December 1, 2010 5990-4883EN