Cerno Application Note Extending the Limits of Mass Spectrometry

Similar documents
Cerno Application Note Extending the Limits of Mass Spectrometry

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Building Inflation Tables and CER Libraries

MassHunter Software Overview

MassHunter TOF/QTOF Users Meeting

Cerno Application Note Extending the Limits of Mass Spectrometry

What s New in NIST11 (April 3, 2011)

Agilent MassHunter Quantitative Data Analysis

Information Dependent Acquisition (IDA) 1

NMR Predictor. Introduction

Agilent All Ions MS/MS

Agilent MassHunter Quantitative Data Analysis

v Prerequisite Tutorials GSSHA WMS Basics Watershed Delineation using DEMs and 2D Grid Generation Time minutes

Jasco V-670 absorption spectrometer

SRM assay generation and data analysis in Skyline

Miniature Fiber Optic Spectrometry StellarNet Tutorial

Ligand Scout Tutorials

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

MAGNETITE OXIDATION EXAMPLE

ICM-Chemist How-To Guide. Version 3.6-1g Last Updated 12/01/2009

Application Note. U. Heat of Formation of Ethyl Alcohol and Dimethyl Ether. Introduction

Using SkyTools to log Texas 45 list objects

POC via CHEMnetBASE for Identifying Unknowns

Using the ACD/MS Manager Software with Agilent 1100 Series LC/MS Systems. Application Note

ST-Links. SpatialKit. Version 3.0.x. For ArcMap. ArcMap Extension for Directly Connecting to Spatial Databases. ST-Links Corporation.

Skyline Small Molecule Targets

Kinetics of Crystal Violet Bleaching

Date: Summer Stem Section:

mylab: Chemical Safety Module Last Updated: January 19, 2018

M E R C E R W I N WA L K T H R O U G H

CLASSIFIY ROCKS THAT ARE SHARED BETWEEN TWO OR MORE GLACIERS AS "NODATA"

Tutorial 2: Analysis of DIA data in Skyline

Designing a Quilt with GIMP 2011

Computer simulation of radioactive decay

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Calculating Bond Enthalpies of the Hydrides

Exercises for Windows

Connect the Vernier spectrometer to your lap top computer and power the spectrometer if necessary. Start LoggerPro on your computer.

How to Create a Substance Answer Set

IncuCyte ZOOM NeuroTrack Fluorescent Processing

The Geodatabase Working with Spatial Analyst. Calculating Elevation and Slope Values for Forested Roads, Streams, and Stands.

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

ON SITE SYSTEMS Chemical Safety Assistant

Location Intelligence Infrastructure Asset Management. Confirm. Confirm Mapping Link to ArcMap Version v18.00b.am

POC via CHEMnetBASE for Identifying Unknowns

PDF-4+ Tools and Searches

Task 1: Open ArcMap and activate the Spatial Analyst extension.

Introduction to Spark

Lecture #19 MINEQL: Intro & Tutorial Benjamin; Chapter 6

PDF-4+ Tools and Searches

1 An Experimental and Computational Investigation of the Dehydration of 2-Butanol

Uncontrolled Copy. SOP-060 Chromatography, Tune Evaluation and Troubleshooting. Table of Contents. 1. Principle... 3

Version 1.2 October 2017 CSD v5.39

Tutorial 8 Raster Data Analysis

COMPOUND REGISTRATION

August 7, 2007 NUMERICAL SOLUTION OF LAPLACE'S EQUATION

Quantification of JEOL XPS Spectra from SpecSurf

An area chart emphasizes the trend of each value over time. An area chart also shows the relationship of parts to a whole.

How to Make or Plot a Graph or Chart in Excel

OPSIAL Manual. v Xiaofeng Tan. All Rights Reserved

Tutorial. Getting started. Sample to Insight. March 31, 2016

Space Objects. Section. When you finish this section, you should understand the following:

About Orbital Elements: Planning to Observe Comets and Minor Planets with Deep-Sky Planner 4

Photometry of Supernovae with Makali i

Learning ArcGIS: Introduction to ArcCatalog 10.1

Last updated: Copyright

Calculating Conflict Density and Change over Time in Uganda using Vector Techniques

Tutorial 1: Setting up your Skyline document

Login -the operator screen should be in view when you first sit down at the spectrometer console:

The OptiSage module. Use the OptiSage module for the assessment of Gibbs energy data. Table of contents

Become a Microprobe Power User Part 2: Qualitative & Quantitative Analysis

Dock Ligands from a 2D Molecule Sketch

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

How to Create Stream Networks using DEM and TauDEM

Titrator 3.0 Tutorial: Calcite precipitation

NMRPredict Functional Block Diagram

Introduction to Structure Preparation and Visualization

Standards-Based Quantification in DTSA-II Part II

Protein Deconvolution Version 2.0

O P E R A T I N G M A N U A L

Learning to Use Scigress Wagner, Eugene P. (revised May 15, 2018)

OECD QSAR Toolbox v.4.0. Tutorial on how to predict Skin sensitization potential taking into account alert performance

Applying MapCalc Map Analysis Software

Multiphysics Modeling

Task 1: Start ArcMap and add the county boundary data from your downloaded dataset to the data frame.

ISIS/Draw "Quick Start"

41. Sim Reactions Example

GIS Workshop UCLS_Fall Forum 2014 Sowmya Selvarajan, PhD TABLE OF CONTENTS

2. To measure the emission lines in the hydrogen, helium and possibly other elemental spectra, and compare these to know values.

Athena Visual Software, Inc. 1

Multi-residue analysis of pesticides by GC-HRMS

Assignment 1: Molecular Mechanics (PART 1 25 points)

Operation of the Bruker 400 JB Stothers NMR Facility Department of Chemistry Western University

2G1/3G4 GIS TUTORIAL >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>

Using a GIS to Calculate Area of Occupancy. Part 1: Creating a Shapefile Grid

Using the Budget Features in Quicken 2008

This tutorial is intended to familiarize you with the Geomatica Toolbar and describe the basics of viewing data using Geomatica Focus.

Figure 2.1 The Inclined Plane

Quick Reference Manual. Ver. 1.3

Peptide Mass Fingerprinting (PMF) Data Acquisition Using the Voyager DE- PRO Database Search with PMF Data using Ms-Fit

Transcription:

Creation of Accurate Mass Library for NIST Database Search Novel MS calibration has been shown to enable accurate mass and elemental composition determination on quadrupole GC/MS systems for either molecular or fragment ions. This capability, which is normally only available from high resolution mass spectrometers, can now be combined with NIST library search to facilitate high confident compound identification as demonstrated previously. With a constraint of either mass tolerance or elemental composition, NIST library search can significantly reduce its possible candidate list to a group isomers defined by the specified elemental composition. In the NIST library, the majority of GC/MS spectra has molecular ions and can certainly benefit from the restricted search as they carry the information of exact mass and elemental composition so the constraints can apply during the search. On the other hand, a significant portion of the library spectra do not have molecular ions and could not be used for the search with the constraints. Here we propose a new approach to performing high mass accuracy GC/MS library search. Instead of utilizing only integer mass accuracy for both molecular and fragment ions in the current NIST library, a new library will be created to include high mass accuracy GC/MS spectra achieved through the novel MS calibration. This new approach will not only expand the applicability of the restricted search to the compounds without molecular ions, but will also enhance search performance for the molecular ions containing spectra by adding high mass accuracy of all the fragment ions for further confirmation. Served as a brief tutorial, this article will document procedures for generating an accurate mass library and performing accurate mass library search. A great example will also be presented. Both Semi-Volatile Organic Compound (SVOC) samples and Perfluorotributylamine (PFTBA) were acquired with an Agilent 5973N GC(6890)/MS system in a raw (profile) scanning mode. The PFTBA spectra acquired for 20 seconds at the end of GC/MS separation were used to build a calibration which was then applied to the sample spectra to obtain high mass accuracy GC/MS spectra by MassWorks. Two data files acquired under different GC conditions were selected for feasibility studies. The spectra from one data file were used to create an accurate mass library, while those from another data file were employed to perform an accurate mass library search using NIST MS Search. The procedure for creating an accurate mass library consists of three main steps: exporting accurate mass spectra from MassWorks to NIST MS Search, editing the exported spectra to include all necessary and relevant chemical information, and saving the spectra in it. Below is an example of the entire process, illustrated with screenshots. To export spectra from MassWorks to NIST MS Search is straightforward. It is done by right clicking in a spectrum window of MassWorks to have a pop-up menu show up (Figure 1). By selecting Library Search from the menu, as marked with the red oval circle, a regular NIST library search will be performed. As a part of the search process, the accurate mass spectra are transferred from MassWorks to NIST MS Search. Make sure the compound highlighted in blue inside the lower left spectral list window in Figure 2 is the correct one before proceeding further. The next step, spectral editing, is a more involved process. Note that there are two rows in this screenshot. The top row is for the accurate mass spectra imported from MassWorks, while the bottom row is for the original integer mass spectra in the NIST library. In each row, the left is a spectral list window, listing all candidates from a given search; the middle is a spectra window, displaying the spectra highlighted at the left; and the right is an information window, indicating name, exact mass, elemental composition, etc., of a selected compound.

The purpose of editing the spectra is to establish a complete record for the spectra, to be included in the accurate mass library. This can be done by copying available information for the same compound which already exists in the library marked with a box in red to the Spectrum Information window of the new spectra. Since there are many manual operations needed to edit the spectra, an efficient sequence is recommended, as follows: 1. Copy all the spectrum information from the library compound usually displayed in the pane at the lower-right (using ctrl+a and ctrl+c) and then paste (ctrl+v) it to a Notepad instance, as shown in Figure 3. This is a time-saving operation to avoid multiple switches from the Lib. Search tab to the Librarian tab for copy/paste operations. Once all the information is copied into Notepad, selective information can be copied from the Notepad to its individual space in the Spectrum Information window of the accurate mass spectra without need to go back to the Lib. Search tab for copying. 2. Bring up the Spectrum Information window. This can be done by clicking Librarian and Names tab (marked with a red oval), highlighting the top compound on the list, then clicking the ed toolbar button (pointed at with a black arrow in Figure 4) to have the spectrum information window appear (Figure 5). 3. Selectively copy information from Notepad and paste it to the Spectrum Information window, updating the contents of the fields in the following manner: 1) Paste the Name of the compound. 2) Paste the CAS Number. 3) Click Attach Struct and From Main (Figure 6a) to get molecular structure. 4) Click From structure to get Formula and Mol. Weight. 5) Paste the Other Names. 6) Write customized message into Comments. 7) Click Replace (Figure 5), then OK (Figure 6b) to ignore the warning message and to update all the information copied/pasted into the spectrum window. To save the spectra into an accurate mass library as the last step is very simple. As all the editing is done, the accurate mass spectra now have complete records including name, formula, structure, etc., (as shown in Figure 7) and reappear on the top of spectral list window with a new updated name. To create the library (the first time only), highlight the updated spectra, click the Create Library toolbar button (pointed at with a red arrow in Figure 7), and provide a name for the library to be created - for example, AM_test (as shown in Figure 8a). The final operation is to click the Add to library toolbar button (pointed at with a black arrow in Figure 7), select the created library, for example AM_test, from the pop-up window (Figure 8b), and click OK to complete. Successful creation of an accurate mass library allows high mass accuracy GC/MS spectra achieved through MassWorks to be searched for high confidence compound identification. Here is a quick example. Before the search, the accurate mass library created needs to be in included for search through Library Search Options. Under the main menu item Option of NIST MS Search, select Library Search Options, click the Libraries tab, select am_test, and then click >> Add >> (Figure 9). The operation to perform accurate mass NIST library search is the same as regular NIST library search, as shown in Figure 2. In the current search, two libraries were used. One is NIST main library and another is an accurate mass library that was just created, called am_test. Search results for the test spectra of a SVOA compound are shown in Figure 10. Although this compound was found in both

libraries, the spectra matched the best with the spectra in the accurate mass library, achieving the top hit with the best match values and probabilities. In addition, high mass accuracy and spectral accuracy for molecular ions (inserts of Fig 10) and high mass accuracy for all fragments provide valuable confirmation. Figure 1. Launch conventional NIST library search from MassWorks Figure 2. NIST Library search results with corrected compound identified and highlighted in blue.

Figure 3. The chemical information from the library compound copied to Notepad Figure 4. To bring up the Spectrum Information window

Figure 5. To copy information from Notepad to this Spectrum Information window Figure 6. Pop-up message windows during above copy/paste

Figure 7. To save the spectra into an accurate mass library Figure 8. Pop-up message windows during creation of a library

Figure 9. Add newly created accurate mass library for search Figure 10. Accurate mass NIST library search results