Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Similar documents
Agilent ESI and APCI sources: for polar to non-polar compounds

Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Agilent G3212 GC-APCI Source

TOF/QTOF Users Meeting. Jim Lau, Agilent Technologies.

Agilent All Ions MS/MS

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Taking Full Advantage of UHPLC with Agilent 6460A Triple Quadrupole MS. Outline

MassHunter TOF/QTOF Users Meeting

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Agilent s LC/MS Portfolio and Applications Examples

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Ultrafast Analysis of Methadone and Metabolite EDDP in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System

Agilent MassHunter Quantitative Data Analysis

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

The new Water Screening PCDL

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Accurate Mass Analysis of Hydraulic Fracturing Waters

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Application Note. Edgar Naegele. Abstract

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 120

Application Note. Abstract. Authors. Food Safety and Environmental

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Making Sense of Differences in LCMS Data: Integrated Tools

LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120

Guide to Peptide Quantitation. Agilent clinical research

Agilent 6495 Triple Quadrupole LC/MS System EXPERIENCE A NEW LEVEL OF CONFIDENCE

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Application Note. Abstract. Authors. Environmental

Analyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 1: Dyes and Pigments. Application. Introduction. Authors. Abstract.

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Theory and Practical Consequences.

László Tölgyesi LC/MS scientist EFSC Demo Group. International Symposium on Food Safety and Quality: Applications of Nuclear and Related Techniques

Application Note. Edgar Naegele. Abstract

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Quantitation of Cystine and Identification of Related Metabolites in White Blood Cells Using a High Resolution Accurate Mass LC/MS Approach

Highly Sensitive and Rugged GC/MS/MS Tool

A Q-TOF Generated, Metabolomics- Specifi c LC/MS/MS Library Facilitates Identifi cation of Metabolites in Malaria Infected Erythrocytes

Application Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract

Detection of Trace Level Pharmaceuticals in Drinking Water by Online SPE Enrichment with the Agilent 1200 Infinity Series Online-SPE Solution

Agilent Technologies LCMS Portfolio

Introducing the Agilent G6410A Triple Quadrupole Mass Spectrometer

SAMHSA-Compliant LC/MS/MS Analysis of Phencyclidine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

Determination of Pharmaceuticals in Water by SPE and LC/MS/MS in Both Positive and Negative Ion Modes Application

materials analysis Solutions for Your Analytical Business Markets and Applications Programs

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Agilent MassHunter Quantitative Data Analysis

Die Nadel im Heuhaufen

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Construction and Use of API Single- Quadrupole MS Spectral Libraries.

LC MS analysis of metabolites. Basis of Chromatography

Separation of Large and Small Peptides by Supercritical Fluid Chromatography and Detection by Mass Spectrometry

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

MassHunter Software Overview

Information Dependent Acquisition (IDA) 1

QTOF Training Manual

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

The Agilent 6495 Triple Quadrupole LC/MS: Peptide Quantitation Performance

Determination of Pharmaceuticals in Water by SPE and LC/MS/MS in Both Positive and Negative Ion Modes

2016 iquan Series: Pesticide Quantitation on the Thermo Scientific TSQ Quantiva

The Agilent 6545 Q-TOF LC/MS System THE ANSWERS YOU NEED: BETTER, FASTER, EASIER

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Thermo Finnigan LTQ. Specifications

Screening and Quantitation of 240 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System

LC/Q-TOF Workflows for Comprehensive Micropollutant Analysis

GC-APCI IMS of Diesel

Analysis of E.coli Tryptic Digest and Intact Protein Using the Agilent 1290 Infinity 2D-LC Solution with Diode Array Detection and Q-TOF LC/MS

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

API Optimization, Source Design, and Other Considerations of LC/MS

Agilent LC & LC-MS Cannabis Testing

Supporting Information

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188A

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

Transcription:

Agilent 6400 Series Triple Quadrupole Users Workshop 1

Agilent 6400 Series Triple Quadrupole Users Workshop QQQ Method Development and Optimization MassHunter Quantitation: Batch and Method setup QC s, Outliers, Data Review 2

Agilent 6400 Series Triple Quadrupole Users Workshop David Presser John Hughes Anabel Fandino David Weil Doug McIntyre Shane Tichy Peter Stone Laura Phillips André Szczesnieski 3

Agenda QQQ method development and optimization Acquisition overview Source optimization for standard and Agilent JetStream sources Compound optimization using flow injection or Optimizer software Dynamic MRM MassHunter Quant software current revision B.06.00 SP1 Creating a Batch and Quantitation method - Setting up QC s - Outliers - Reviewing data - Reporting and Exporting data 4

Agilent ESI and APCI sources: for polar to non-polar compounds Nebulizer Pressure Corona current Nebulizer Pressure Vaporizer Vcap Vcap Drying Gas Temperature and Flow Fragmentor V Drying gas Temperature and Flow Fragmentor V 5

Agilent Jetstream Technology (AJT) The super-heated sheath gas collimates the nebulizer spray and presents more ions to the MS inlet. Enhanced efficiency nebulizer Nebulizing gas: pressure *Sheath gas: flow and temperature *Nozzle voltage Drying gas: flow and temperature Resistive sampling capillary entrance: Capillary V Resistive sampling capillary exit: FragV *New parameters unique to AJT source 6

Tuning and Calibration for Agilent QQQ systems Agilent QQQ systems are very stable and require infrequent Autotuning Current software uses "ESI-Low" tune mix for all QQQs. Routine use only requires resolution and mass axis verification for polarity and resolution modes to be used. Run performance check sample (lab SOP) Do Checktune (checks all three resolution modes) In Manual Tune, turn on calibrant and observe MS1 and MS2 profiles. Use Adjust Gain and Offset button if width or mass axis requires adjustment. If using negative ion, Autotuning should be done monthly or less to minimize source exposure to TFA. Flush source extensively with LC flow after Autotune before running samples in negative ion. Autotune at least quarterly to optimize ion transmission and update EM voltage. 7

Source optimization for Agilent LC/MS systems ESI, APCI, MM and Agilent JetStream Technology (AJT) Flow dependent parameters: Nebulizer pressure Drying gas temperature and flow Vaporizer temperature (MM) Sheath gas flow (AJT) Compound dependent parameters: Capillary voltage Fragmentor voltage Collision Energy (QQQ, QTOF) Vaporizer temp (APCI, MM, AJT) Sheath gas temperature (AJT) Nozzle voltage (AJT) 8

6410 starting parameters for small molecules 6410 Parameter Standard ESI source APCI source Capillary voltage 3500 V 3500 V Drying gas flow 10 Lpm < 0.2 ml/min 12 Lpm > 0.4 ml/min 5-7 Lpm Drying gas temp 350 C 350 C Fragmentor voltage 135 V 135 V Nebulizer pressure 25 psi 0.2 ml/min 50 psi 1 ml/min 60 psi Vaporizer temp 350 C 9

Multi-Mode Source starting parameters Multimode ESI APCI Mixed mode Capillary voltage 2000 V 2000 V 1000 V Charging voltage 2000 V 2000 V 2000 V Corona current 0 5 1 Drying gas flow 5 Lpm 5 Lpm 5 Lpm Drying gas temp 250 C 300 C 300 C Fragmentor voltage 135 V 135 V 135 V Nebulizer pressure 60 psi 20 psi 40 psi Vaporizer temp 150-200 C 200-250 C 150-250 C 10

6460 starting parameters for small molecules 6460 Parameter Starting value Capillary voltage 3500 V CAV acceleration 7 volts Drying gas flow 10 L/min Drying gas temp 300 C Fragmentor voltage 135 V Nebulizer pressure 45 psi Nozzle voltage 0 V pos, 2000 V neg Sheath Gas flow 11 L/min Sheath Gas temp 300 C 11

6490 starting parameters for small molecules 6490 Parameter Starting value Capillary voltage CAV acceleration voltage Drying gas flow 3500 V 5 volts 15 L/min Drying gas temp 150 C Fragmentor voltage ifunnel high pressure RF ifunnel low pressure RF Nebulizer pressure 380 V fixed 110 V pos, 90 V neg 60 V pos, 40 V neg 30 psi (flow dependent) Nozzle voltage 0 V pos, 2000 V neg Sheath gas temp 225 C Sheath gas flow 11 L/min 12

Optimizing the Agilent JetStream Technology beginning with recommended starting values ( ) Order of effect on sensitivity Sheath gas temperature (225 C) Things to note Typically 50 C above DGT Sheath gas flow (11 Lpm) Generally 10-12 Lpm for 0.2-0.7mL Nebulizer pressure (30 psi) LC flow and mobile phase dependent Capillary voltage (3500V) Somewhat MW dependent Nozzle voltage (0V) Very compound and polarity dependent Drying gas temperature (150 C) Interaction with flow and sheath parms Drying gas flow (15 Lpm) Higher when in doubt 13

Optimizing the Agilent JetStream Technology Typical values ( ) and Increments Order of effect on sensitivity Sheath gas temperature (225 C) Sheath gas flow (11 Lpm) Nebulizer pressure (30 psi) Capillary voltage (3500V) Nozzle voltage (0V) Drying gas temperature (150 C) Drying gas flow (15 Lpm) Increments and ranges to test 50 C, 225-400 C 2 Lpm, 8-12 Lpm 5 psi, 25 50 psi 500V, 2500-4500V 500V, 0-2000V 50 C, 200-350 C 2 Lpm, 5-20 Lpm 14

Source Optimization 6490 15

Optimization techniques Fragmentor V and Collision Energy (for MS/MS systems) should be optimized first using recommended starting parameters for source. Voltages, gas flows change quickly and can be optimized with series of flow injections using method with injector program and time segments. Temperatures (sheath gas, drying gas, vaporizers) require equilibration time between injections; perhaps best done with final chromatography conditions. 16

Injector program for series of flow injections Injector program steps: Remote Startpulse [Starts the instrument] Repeat n times Draw default amount from sample Valve to Mainpass [injects sample without start signal] Wait 0.20 min [allow sample to elute from needle before repeating] End repeat Note: Remote Startpulse and Inject commands work differently on QQQ and TOF/QTOF. 17

MS acquisition for series of flow injections: Synchronize MS time segments with peak spacing Example: MS time segments increment nozzle voltage 18

Fragmentor and Collision Energy optimization Flow injection with injector program: Methylmalonic acid, dibutyl ester Maximize MH+ ion transmission, minimize CID with Fragmentor voltage Maximize product ion signal(s) with Collision Energy Can fine tune each with smaller steps after initial experiments Fragmentor 60-160V 20V steps Collision Energy 5-30V 5V steps 19

Optimization of MRM Acquisition Good quantitation requires adequate number of data points across each peak (ideally 10-20) High confidence or regulated identification requires > 1 MRM per compound. Monitoring many compounds simultaneously lowers dwell time per MRM. Therefore for best sensitivity, only monitor compounds in retention time window where they elute. Traditional approach of time segments has limitations and is tedious to setup up and maintain. 20

UHPLC peak capacities are very high 40 MRM transitions in a one minute window 21

The solution: MassHunter Dynamic MRM Included in QQQ Acquisition B.02.01 and later For applications requiring quantitation of 100 1000 compounds in one run; some examples: Food and environmental analysis (e.g. pesticides) Targeted quantitation of proteins via peptides (proteomics) Without Dynamic MRM: Need to manually set up multiple time segments to maximize dwell times Tedious to set up; problematic if retention time changes With Dynamic MRM: Automatic setup of overlapping time segments without user intervention May increase signal to noise Can update all retention times using latest run 22

MRM: width approximates dwell time 0.03min "Delta Ret Time" = 0.2 min (12 sec) 23

Dynamic MRM: automatically maximizes dwell time 0.03min "Delta Ret Time" = 0.2 min (12 sec) 24

Dynamic MRM for 6400 series QQQ Monitors transitions only when compound elutes 25

Dynamic MRM: Retention Time and Delta Ret Time 26

Dynamic MRM Update Method in Acquisition 27

Update RTs, RT windows, add new compounds Recommend using: Quant report folder 28

Dynamic MRM Analysis with 6460 QQQ Eight minute 250 compound pesticide screen Peak widths ~ 1 second Retention Time Window = 12 sec 500 ppt Zorbax Eclipse Plus C18 2.1 x 100mm (1.8μm) 29

MassHunter Optimizer Included as of MassHunter QQQ B.04 acquisition software Useful for frequent method development [new compound each week] or for multi-compound methods [e.g. toxicology, environmental applications] Many toxicology and pesticide transitions are available in new Agilent application kits and from Agilent application chemists. Can use Flow Injection before LC separation is developed Can use LC method to optimize multiple compounds in a few injections 30

MassHunter Optimizer method, parameter selection 31

MassHunter Optimizer Precursor ion selection User selectable adducts (H, Na, K, OAc-, HCOO-, etc.) Can run both positive and negative ion methods in same project 32

MassHunter Optimizer Product ion selection: set mass range 33

MassHunter Optimizer input a unique compound name 34

MassHunter Optimizer results Results automatically added to MRM database 35

MassHunter Optimizer results inspect data 36

MassHunter Optimizer - import directly into acquisition 37

MassHunter Optimizer Search or filter compounds for import 38

MassHunter Optimizer Search or filter compounds for import 39

MassHunter Acquisition imported transitions 40

MassHunter Optimizer input transitions 41

MassHunter Optimizer input transitions 42

MassHunter Optimizer input transitions 43

MassHunter Optimizer input transitions 44

MassHunter Optimizer input transitions 45