FIELD TEST OF WATER-STEAM SEPARATORS FOR THE DSG PROCESS

Similar documents
SOME ASPECTS ON PARABOLIC TROUGH FIELD OPERATION WITH OIL AS A HEAT TRANSFER FLUID

COMBINED MEASUREMENT OF THERMAL AND OPTICAL PROPERTIES OF RECEIVERS FOR PARABOLIC TROUGH COLLECTORS

Solar Flat Plate Thermal Collector

Journal of NUCLEAR SCIENCE and TECHNOLOGY, Vol. 41, No. 7, p (July 2004)

A comparative study on the hydrodynamics of liquid liquid hydrocyclonic separation

Numerical Simulation on Flow and Heat Transfer in Oscillating Heat Pipes

Unsteady effects in direct steam generation in the CLFR

3D Simulation of the Plunger Cooling during the Hollow Glass Forming Process Model, Validation and Results

Available online at ScienceDirect. Energy Procedia 69 (2015 )

ECE309 INTRODUCTION TO THERMODYNAMICS & HEAT TRANSFER. 13 June 2007

CFD ANALYSIS FOR DESIGN OPTIMIZATION OF REVERSE FLOW TYPE CYCLONE SEPARATOR

Optimization high vortex finder of cyclone separator with computational fluids dynamics simulation

HEAT LOSS MEASUREMENTS ON PARABOLIC TROUGH RECEIVERS

N. Lemcoff 1 and S.Wyatt 2. Rensselaer Polytechnic Institute Hartford. Alstom Power

A Review on Gas Solid Cyclone Separator Parametric Analysis Shah Nikhil 1

BME-A PREVIOUS YEAR QUESTIONS

EFFECT OF DISTRIBUTION OF VOLUMETRIC HEAT GENERATION ON MODERATOR TEMPERATURE DISTRIBUTION

INTRODUCTION: Shell and tube heat exchangers are one of the most common equipment found in all plants. How it works?

Analysis of the Cooling Design in Electrical Transformer

Proceedings of the 4th International Modelica Conference, Hamburg, March 7-8, 2005, Gerhard Schmitz (editor)

If there is convective heat transfer from outer surface to fluid maintained at T W.

Comparison of discharge measurements - Thermodynamic to US Clamp- On, stationary US and Needle Opening Curve

Vertical Mantle Heat Exchangers for Solar Water Heaters

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT

DESIGN OF CYCLONE AND STUDY OF ITS PERFORMANCE PARAMETERS

Numerical analysis of natural convection in a latent heat thermal energy storage system containing rectangular enclosures

2 Navier-Stokes Equations

Heat Exchangers for Condensation and Evaporation Applications Operating in a Low Pressure Atmosphere

EXPERIMENTAL ANALYSIS OF R-134a FLOW CONDENSATION IN A SMOOTH TUBE

Piping Systems and Flow Analysis (Chapter 3)

R13 SET - 1 '' ''' '' ' '''' Code No RT21033

HEAT TRANSFER ENHANCEMENT IN HEAT EXCHANGER USING TANGENTIAL INJECTOR TYPE SWIRL GENERATOR

The Research of Heat Transfer Area for 55/19 Steam Generator

Cyclones. Vane Axial Cyclone 10/30/2013. EVE 402 Air Pollution Generation and Control. Chapter #5 Lectures (Part 4) A mechanical gas cleaning device

Experimental Investigation of the Velocity Distribution near the Swirl Generator of a Uniflow Cyclone for Performance Data Prediction

Answers to questions in each section should be tied together and handed in separately.

first law of ThermodyNamics

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560

Residual Chlorine Monitor

Flow instabilities in a vertical tube reboiler

External Pressure... Thermal Expansion in un-restrained pipeline... The critical (buckling) pressure is calculated as follows:

EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER

HEAT TRANSFER CAPABILITY OF A THERMOSYPHON HEAT TRANSPORT DEVICE WITH EXPERIMENTAL AND CFD STUDIES

Name: 10/21/2014. NE 161 Midterm. Multiple choice 1 to 10 are 2 pts each; then long problems 1 through 4 are 20 points each.

ME332 FLUID MECHANICS LABORATORY (PART II)

Heat and Mass Transfer Unit-1 Conduction

Experimental and Theoretical Evaluation of the Overall Heat Loss Coefficient of a Vacuum Tube Solar Collector

An Essential Requirement in CV Based Industrial Appliances.

Investigation of the flow in a flat bottom cyclone

THERMAL AND OPTICAL CHARACTERIZATION OF PARABOLIC TROUGH RECEIVERS AT DLR S QUARZ CENTER RECENT ADVANCES

Engineering of centrifugal dust-collectors based on parallel comparing tests applying computer modelling

Overview of solar receiver design

ECH 4224L Unit Operations Lab I Thin Film Evaporator. Introduction. Objective

Effect of Geometric Parameters on the Performance of Cyclone Separator using CFD

10.52 Mechanics of Fluids Spring 2006 Problem Set 3

Chapter Four fluid flow mass, energy, Bernoulli and momentum

Effect of Geometric Configuration on Performance of Uniflow Cyclone

Department of Energy Fundamentals Handbook. THERMODYNAMICS, HEAT TRANSFER, AND FLUID FLOW, Module 3 Fluid Flow

Analysis of Heat Transfer Enhancement in Spiral Plate Heat Exchanger

RECORD AND ANALYSE THE PRESSURE-ENTHALPY DIAGRAM FOR A COMPRESSION HEAT PUMP

Simplified Collector Performance Model

C H A P T E R 5 ENVIRONMENTAL PROTECTION AGENCY. APTI 413: Control of Particulate Matter Emissions. Student Manual Chapter 5.

Hydraulic modeling assessment Copyright 2010, Optimized Technical Solutions, LLC

CFD-Modeling of Turbulent Flows in a 3x3 Rod Bundle and Comparison to Experiments

Numerical Study Of Flue Gas Flow In A Multi Cyclone Separator

10 minutes reading time is allowed for this paper.

NEGST. New generation of solar thermal systems. Advanced applications ENEA. Comparison of solar cooling technologies. Vincenzo Sabatelli

Keywords: Spiral plate heat exchanger, Heat transfer, Nusselt number

Department of Engineering and System Science, National Tsing Hua University,

Basic Principles of an Adsorption Heat Storage System

Coolant. Circuits Chip

INDUSTRIAL EXPERIENCE WITH HYBRID DISTILLATION PERVAPORATION OR VAPOR PERMEATION APPLICATIONS

An analytical model for the fractional efficiency of a uniflow cyclone with a tangential inlet

THE EFFECT OF SOLID PARTICLE SIZE UPON TIME AND SEDIMENTATION RATE

Increase Productivity Using CFD Analysis

Material and Design Requirements for Advanced Concentrators

Department of Energy Science & Engineering, IIT Bombay, Mumbai, India. *Corresponding author: Tel: ,

Characterization of high temperature solar thermal selective absorber coatings at operation temperature

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Study on the flow and thermal characteristics of a heat storage system

Experimental investigation on up-flow boiling of R1234yf in aluminum multi-port extruded tubes

NUMERICAL SIMULATION ON FLOW AND HEAT TRANSFER IN OSCILLATING HEAT PIPES

Liquid Feed Injection in a High Density Riser

CHAPTER EIGHT P U M P I N G O F L I Q U I D S

Chapter 4 DYNAMICS OF FLUID FLOW

Experimental and numerical study of velocity profiles in FGD reactor

SEM-2017(03HI MECHANICAL ENGINEERING. Paper II. Please read each of the following instructions carefully before attempting questions.

CHAPTER 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES

CHAPTER 3 MODELLING AND ANALYSIS OF THE PACKED COLUMN

DETERMINATION OF R134A S CONVECTIVE HEAT TRANSFER COEFFICIENT IN HORIZONTAL EVAPORATORS HAVING SMOOTH AND CORRUGATED TUBES

Unit Workbook 2 - Level 5 ENG U64 Thermofluids 2018 UniCourse Ltd. All Rights Reserved. Sample

Evaluating New Generation Vibrating Tube Sensor for Density Measurement under Process Conditions

Droplet behaviour in a Ranque-Hilsch vortex tube

Multiphase Flow and Heat Transfer

EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (51) Int Cl.: B01D 9/00 ( )

Study of Compound Heat Transfer Enhancement of Horizontal Liquid-Solid Fluidized Bed Heat Exchanger with a Kenics Static Mixer

CFD STUDIES IN THE PREDICTION OF THERMAL STRIPING IN AN LMFBR

Therefore, the control volume in this case can be treated as a solid body, with a net force or thrust of. bm # V

Modeling of Wall-boiling Phenomena from Nucleate Subcooled Boiling up to CHF Conditions

PR CYCLONE SECONDARY SHUTOFF

Transcription:

FIELD TEST OF WATER-STEAM SEPARATORS FOR THE DSG PROCESS Markus Eck 1, Holger Schmidt 2, Martin Eickhoff 3, Tobias Hirsch 1 1 German Aerospace Center (DLR), Institute of Technical Thermodynamics, Pfaffenwaldring 38-40, 70569 Stuttgart, Germany, Tel.: +49 (0) 711/6862 429, Fax: +49 (0) 711/6862 747, markus.eck@dlr.de 2 Framatome ANP, Freyerslebenstr. 1, 91058 Erlangen 3 German Aerospace Center (DLR), Institute of Technical Thermodynamics, Plataforma Solar de Almería, 04200 Tabernas/Almería, Spain Abstract Direct steam generation (DSG) in parabolic trough collectors is a promising option for improving mature SEGS type parabolic trough technology for solar thermal power plant application. The European DISS and INDITEP projects have proven the feasibility of the DSG process in parabolic trough collectors under real solar conditions at the life size DISS test facility at the Plataforma Solar de Almería (PSA) [1]. These projects have also shown that the recirculation mode is the preferred operation mode for DSG collector fields for near term applications. The water-steam separator is a key component of collector fields operated in recirculation mode. Both compact water-steam separators for every single row or huge separation drums for the whole collector field are conceivable. Small compact water-steam separators offer the advantage of a lower inertia, thus reducing the time for start-up and lower investment. Within INDITEP and the German R&D project SOLDI compact water-steam separators have been developed, manufactured and tested by DLR and Siemens, with its subcontractor Framatome ANP. Prototypes of a cyclone and a baffle separator have been implemented into the DISS test facility. More than 200 tests have been performed to investigate the separation efficiency, the pressure loss and the performance under transient conditions. Keywords: water-steam separator, direct steam generation, cyclone separator, baffle separator Introduction ------------------------------------ In the European R&D project INDITEP, a Spanish-German consortium has taken the last step in the demonstration of DSG technology in MW scale. The main work package was the detailed engineering of a demonstration plant with a net power of 5 MW. In a second work package key components of a DSG collector field such as high pressure ball joints or compact water-steam separators have been investigated. Copyright by SolarPACES 1

Siemens, with its subcontractor Framatome, has developed two different compact small cyclone separators. These cyclones were designed to be implemented into the DISS test facility at the PSA. Accordingly, they had to withstand the design parameters of the DISS test facility (p = 100 bar, T = 400 C). More than 150 tests have been performed to investigate their performance under steady-state and transient conditions. In parallel, DLR has developed a baffle separator for comparison. The design and construction of the baffle separator was funded by the German Federal Ministry for the Environment (BMU). In the first sections of this paper the basics of the investigated separators will be presented. After explaining the test set-up and the chosen analysis procedure the main results will than be presented and discussed. Cyclone Separator Centrifugal forces are responsible for the phase separation in cyclones. A two-phase mixture enters tangentially into the cyclone causing a spiral motion of the gas phase. The axial flow is directed downwards in the outer region and upwards in the core region with the cleaned gas leaving the cyclone through the vortex finder. The particles in the stream are centrifuged to the wall where they move downwards into a collecting chamber. Depending on the type of particles to be separated, different geometrical designs of cyclonic separators are used. For the separation of liquids, no conical section in the lower part of the cyclone is necessary. Instead, a simple cylindrical cyclone is used, which can be divided into an upper section where separation takes place and a lower section where the liquid is collected. This design has the advantage of guaranteeing a well-defined flow situation in the upper part. In combination with a vortex breaker at the water outlet a sufficiently high liquid level in the lower part avoids the problem of gas being suctioned into the liquid outlet. Furthermore, only a flat liquid surface allows the measurement of the liquid level, which is necessary for the control of the liquid discharge. In the present investigation, cylindrical cyclones of two different body diameters are used. The first cyclone has an inner diameter of 76.1 mm (Cyclone 1). The second cyclone has an inner diameter of 88.9 mm (Cyclone 2). Figure 1: Schematic diagram of a cyclone separator Figure 2: Schematic diagram of a baffle separator. (Not to scale) Copyright by SolarPACES 2

Baffle Separator Baffle separators are a common device especially designed for droplet elimination from gas streams. Typical applications are air dryers in cooling devices and air cleaners for industrial exhaust streams with cut sizes in the range of 5 to 30 microns. In principle two different configurations are possible. First the gas stream can be directed horizontally through the wave-plate package and separated particles move downwards on the walls or can be collected in drainage channels. Second, the gas stream can be vertically directed upwards causing small droplets to be separated on the wave-plates. There they form a film flowing downwards against the gas stream. Larger droplets created by film break-up are now able to overcome the drag in the gas stream and fall into a sump. For the present investigation, a design with horizontal gas stream is used, see figure 2. Test Set-Up and Procedure The DISS test facility has a total length of 700 m. The compact water steam separators presented in this paper are installed 100 m in front of the end of the collector loop. Accordingly, the first 600 m are used as an evaporation section and the last 100 m as a superheating section (s. Fig. 3). The water-steam mixture from the evaporation section enters the separator, where the separated steam is than fed to the superheating section. The water outlet of the separator is connected to a vessel with a volume of 4 m 3 and drained by gravity. Under steady state conditions no water remains in the separator. The water in the vessel is finally re-circulated to the inlet of the collector loop. Figure 3: Schematic Setup of the DISS test facility with the used measuring points. For the assessment of the different separators two main parameters characterize the steadystate performance; the separation efficiency and the pressure loss caused by the separator. The pressure loss is measured by a differential pressure sensor that measures the pressure loss between the separator inlet and its steam outlet. In addition, the influence of swirl breakers at the steam outlet of the separator is investigated by differential pressure sensors over the collectors within the superheating section. Copyright by SolarPACES 3

The separation efficiency is determined by a heat balance on the first collector of the superheating section, collector 9. Collector 9, the so called special test collector, is chosen since it is equipped with the most thermocouples along its length allowing for the most reliable thermal analyses (s. figure 3). Collector 9 has a thermocouple at the collector inlet measuring the fluid temperature and several thermocouples along the collector length measuring the wall temperature. For the thermal analyses the so called A-thermocouples, located in opposition to the irradiated region of the absorber tube are used. The thermocouples along the superheating section are used to determine the position where the superheating begins. This is the position where the temperature exceeds the saturation temperature of the compressed water. This position is displayed in figure 4 for two different steady-state tests. Once this point is identified, a detailed energy balance is used to determine the amount of water torn out into the superheating section and thus the separation efficiency of the separator. 380 370 Temperature [ C] 360 350 340 330 320 310 Test-57 Test-60 300 290 280 580 600 620 640 660 680 700 720 Length [m] Figure 4: Measured temperatures along the superheating section for two different steady-state tests (collectors 9 to 11 from l = 600 700 m). Error Analysis The pressure loss of the separator is measured directly by pressure drop transmitters mounted at the positions of interest. The measurement error can then be expressed by the accuracy of the sensors. The absolute accuracy of the pressure drop transmitter used is 0.07 bar. The separation efficiency is not measured directly. As described above it depends on several measured values and calculated quantities. Accordingly, the accuracy of the determined efficiencies depends on numerous factors such as the accuracy of sensors used, faulty determination of steam properties and un-precise consideration of heat losses. The accuracy of the sensors used for the calculation is listed in Table 1. All Temperatures are measured with an accuracy of 1 K. The law of error propagation is applied to the evaluation procedure used. As displayed in figure 5, the accuracy depends Copyright by SolarPACES 4

strongly on the inlet steam quality. The higher the steam quality the higher the error. An increasing steam quality means a decreased water content of the two phase flow at the separator inlet. If this water content decreases more and more it will be more difficult to detect the accordingly lower water mass flux passing through the separator. Although the measurement error is very high for steam qualities higher than 90 %, the evaluation procedure used is appropriate to assess different separators for inlet steam qualities lower than 90 %. Since the design inlet steam quality for the planned INDITEP power plant is 75 %, the measured results are useful for a first assessment of the investigated separator options. Sensor Accuracy Unit Mass Flux FT-MI-002 0.04 kg/s FT-MI-008 0.03 kg/s Pressure PT-MI-002 0.7 bar PT-MI-400 0.7 bar Pressure Drop PDT-MI-400 0.07 bar Table 1: Absolute accuracy of the sensors used (For further information on the sensor position s. figure 3). 20 15 10 Measurement Error [%] 5 0-5 -10-15 -20 Steam Quality [-] Figure 5: Measurements accuracy for several measured separation efficiencies as a function of the inlet steam quality. Results Pressure Loss The pressure loss coefficient ζ of a separator is expressed by equation (1). p ζ = (1) ρ 2 2 w Where p is the measured pressure drop, ρ the fluid density and w the velocity. In both cases the velocity is calculated with the cross section of the absorber pipe (50 mm). For separators the pressure loss coefficient is not constant but depends on the liquid load and thus of the Copyright by SolarPACES 5

steam quality at the separator inlet. Figure 6 displays the pressure loss coefficient for the investigated separators as a function of the inlet steam quality. According to figure 6 the pressure loss coefficient increases with an increasing amount of water at the separator inlet. With higher steam qualities the pressure loss converges to the value for the pure steam flow expressed by a steam quality of one. Another important result is that the pressure loss of the cyclones is more than five times higher than that of the baffle separator. This is mainly caused by the perpendicular redirection of steam flow in the cyclones causing a large change in momentum. Figure 6 also shows that the pressure loss coefficient of the cyclones is very sensitive to their inner diameter. The pressure loss of cyclone 1 (inner diameter 76.1 mm) is roughly twice as high as that of cyclone 2 (inner diameter 88.9 mm). Therefore, a further increase of the cyclones inner diameter could reduce its pressure loss significantly. However, increasing the inner diameter more and more would lead to cyclones that are no longer compact. According to the performed investigations, baffle separators tend to lower pressure losses as cyclones. Finally, it has to be stated that the parasitic power consumption of the collector field caused by the pressure loss (0 2 bar for the operation range of a DSG collector loop) is negligible compared to the thermal power of the collector field [2]. Separation Efficiency The efficiency of a separator η sep is defined by equation (2) as the ratio of the separated liquid mass flux to the total liquid mass flux at the separator inlet. & L, sep m η sep = (2) m& L 60 50 Cyclone 1 Pressure Loss Coefficient [-] 40 30 20 10 Cyclone 2 Baffle 0 Inlet Steam Quality [-] Figure 6: Pressure loss coefficient for the investigated separators as a function of the inlet steam quality measured at 70 bar. Copyright by SolarPACES 6

As a first step, the influence of the operation pressure on the separation efficiency is investigated. Figure 7 displays the results for the baffle separator. According to figure 7 the operation pressure has no influence on the separation efficiency. The same result was achieved for the cyclones. Furthermore, it was observed that the inner diameter of the cyclones has no influence on the measured separation efficiency. 100 95 90 Separation Efficiency [%] 85 80 75 70 65 60 p = 30 bar p = 70 bar 55 50 Inlet Steam Quality [-] Figure 7: Measured separation efficiency of the baffle separator for different operation pressures. The separation efficiencies measured for the cyclones and the baffle separator are compared in figure 8. According to figure 8, there is no distinct difference between the measured efficiencies. For steam qualities higher than 0.6, the difference is smaller than the measurement error (s. figure 5). For lower steam qualities, the baffle separator tends to higher separation efficiencies. This statement is supported by figure 9 where the position of the beginning of the superheating is plotted as a function of the steam quality. Again, the baffle separator tends to shorter evaporation lengths for lower steam qualities. The most interesting conclusion that can be drawn from figure 9 is that both separators have a threshold value of the inlet steam quality. Above this threshold, the measured evaporation length is nearly constant. This threshold value corresponds to the steam quality in figure 8 where the separation efficiency starts to decrease significantly at approx. 0,7. If the steam quality at the steam outlet of the separator is plotted as a function of the steam quality (not presented in this paper) it turns out that this steam quality increases slightly until the observed threshold and then tends to remain constant at a value higher than 95 %. Accordingly, the cyclones especially seem to have a minimum water load that causes an overflow of the separator. Copyright by SolarPACES 7

From figure 9 it can be deduced that the separators are operated best at an inlet steam quality between 0,7 and 0,8. In this operation range the evaporation length within the superheating section is no longer decreasing and the separation efficiency is still higher. Furthermore this operation range guarantees a sufficient safety margin against dry-out at the separator inlet (end of evaporation section) under transient conditions. 100 95 90 Separation Efficiency [%] 85 80 75 70 65 60 Baffle Separator cyclone 55 50 Inlet Steam Quality [-] Figure 8: Measured separation efficiency of the baffle and the cyclone separator. 90 80 70 Evaporation Length [m] 60 50 40 30 20 Baffle Cyclone 10 0 Inlet Steam Quality [-] Figure 9: Measured evaporation length within the superheating section of the baffle and the cyclone separator. Copyright by SolarPACES 8

Conclusion A baffle separator and two cyclone separators with different inner diameters have been designed, manufactured and tested under real solar conditions at the DISS test facility at the Plataforma Solar de Almería (PSA) in Spain. Both separator systems have been assessed regarding their pressure loss characteristics and their separation efficiency. It was found that the investigated baffle separator has a lower pressure loss coefficient than the cyclones. The pressure loss coefficient depends on the steam quality at the separator inlet but not on the operation pressure. In case of the cyclones, the pressure loss coefficient is very sensitive to the inner diameter of the cyclones. The characteristic of the separation efficiency of both separator types is similar. Both separator types have an excellent separation efficiency (> 95 %) for lower inlet steam qualities. For both separator types the efficiency decreases with increasing inlet steam quality but their performance is still satisfying. The operation pressure and the inner diameter of the cyclones have no significant influence on the separation efficiency. The observed deviation between the investigated separators is within the measurement accuracy of the assessment procedure used. The investigation presented in this paper has shown that compact water-steam separators are available that offer a good system performance under real DSG conditions. The ideal operation range for both separators is an inlet steam quality of 0.7 to 0.8. Acknowledgement The authors would like to thank the European Commission for the financial support given to the INDITEP project (contract No. NNE5-2001-00124) and the German Ministry for the Environment, Nature Conservation and Nuclear Safety for the financial support given to the SOLDI project (contract No. 16UM0024) We would also like to thank the Ciemats staff at the PSA for the performance of the tests and the good cooperation throughout the projects. References [1] Zarza E., Valenzuela L., León J., Hennecke K., Eck M., Weyers H.-D., Eickhoff M.: Direct Steam Generation in Parabolic Troughs Final Results and Conclusions of the DISS Project, Energy, Vol. 29 (2004) pp. 635-644 [2] Eck M., Zarza E.: Assessment of Operation Modes for Direct Solar Steam Generation in Parabolic Troughs, 11 th International Symposium on Solar Thermal Concentrating Technologies, Zurich (2002) p. 591-598 Copyright by SolarPACES 9