Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher

Similar documents
Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher

The Multi-Wiper HE. High Energy Nuclear Medicine Well Counter. The first multi-well counters designed specifically for Nuclear Medicine!

Research Gamma Counter

1 of :32

CapeSym, Inc. Radiation Detection Solutions

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Design and production of Scintillation Detectors

FoodScreen Radiological Food Screening System

Applied Nuclear Science Educational, Training & Simulation Systems

Characterizing, Simulating, and Eliminating Vibration Induced Counts in Measurement While Drilling Gamma Ray Detectors. authors

ß + RADIATION. Choose your application of. chromatography controlled. chemical purity TLC PET GABI. PET GABI 2x2 Nal (Tl) 0 1V output.

ɣ-radiochromatography

LS6500 Scintillation Counting Systems

MEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah

Sample Spectroscopy System Hardware

Alpha spectrometry systems. A users perspective. George Ham. 26 th May Date Month Year

List of Nuclear Medicine Radionuclides. Nuclear Medicine Imaging Systems: The Scintillation Camera. Crystal and light guide

1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter

Quality Assurance. Purity control. Polycrystalline Ingots

Shielded NaI(Tl) γ-ray Spectrometer with High-Precision Spectrum Analysis

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING

What is scintigraphy? The process of obtaining an image or series of sequential images of the distribution of a radionuclide in tissues, organs, or

CHEMISTRY 170. Radioisotopes

Lab NUC. Determination of Half-Life with a Geiger-Müller Counter

Scintillation Detector

Compton suppression spectrometry

Detection and measurement of gamma-radiation by gammaspectroscopy

4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values.

The Best Gamma-Ray Detector

Calibration & Use of a Capintec CAPTUS 3000 Portable Thyroid Uptake System for Iodine-125 Bioassay Measurements Todd W.

QuantumMCA QuantumNaI QuantumGe QuantumGold

Applied Nuclear Science Educational, Training & Simulation Systems

CHEMISTRY 130 General Chemistry I. Radioisotopes

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

Radiation Detection and Measurement

RADIATION-METER TM-91/TM-92

"Neutron Flux Distribution"

Working Copy. P /ru /,6. 8-tt tt. EffectiveDate: I ^, Operation and Calibration of the Tri-Carb Liquid Sclntillation Counter QAM-RI.106.

Gamma ray coincidence and angular correlation

ISOCS / LabSOCS. Calibration software for Gamma Spectroscopy


Hidex 300 SL Automatic TDCR Liquid Scintillation Counter

An ultra-sensitive, versatile, and affordable single tube luminometer for Life Science Research.

Calibration of the Modular Neutron Array (MoNA)

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

The Mössbauer Effect

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Alpha-energies of different sources with Multi Channel Analyzer (Item No.: P )

arxiv: v2 [physics.ins-det] 8 Feb 2013

Unit 2. Instrumentation. Experts Teaching from Practical Experience

Gamma Spectroscopy. References: Objectives:

Dependence Of Gamma Ray Attenuation On Concentration Of Manganese (II) Chloride Solution

Radioactivity. (b) Fig shows two samples of the same radioactive substance. The substance emits β-particles. Fig. 12.1

GAMMA RAY SPECTROSCOPY

RADEAGLET. Lightweight Handheld Radioisotope Identification Device

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications

2100TR Liquid Scintillation Counter

General Overview of Radiation Detection and Equipment

RPR 29 CYCLOTRON RADIOCHEMISTRY LABORATORY

Examples for experiments that can be done at the T9 beam line

Radiation Detection. 15 th Annual OSC Readiness Training Program.

Outline Chapter 14 Nuclear Medicine

PYCKO SCIENTIFIC LIMITED

ORTEC Experiment 24. Measurements in Health Physics. Equipment Required

He-3 Neutron Detectors

Alpha-Energies of different sources with Multi Channel Analyzer

FRAM V5.2. Plutonium and Uranium Isotopic Analysis Software

ORTEC AN34 Experiment 10 Compton Scattering

Gamma Ray Spectroscopy

The RX-6000 Sulfur in Oil Analyzer For the analysis of Sulfur in Oil and other elements from S to U

BWXT Y-12 Y-12. A BWXT/Bechtel Enterprise SMALL, PORTABLE, LIGHTWEIGHT DT NEUTRON GENERATOR FOR USE WITH NMIS

Chapter Seven (Nuclear Detectors)

Figure 1. Decay Scheme for 60Co

Characterization of Large Structures & Components

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

Radionuclide Imaging MII Detection of Nuclear Emission

Validation of detection efficiency of alpha particles in commercial liquid scintillation counters

Renewed whole-body counting chamber in STUK

Introduction to gamma spectroscopy on a budget. Daniel Emes SA Radiation

Analyzing Radiation. Pre-Lab Exercise Type of Radiation Alpha Particle Beta Particle Gamma Ray. Mass (amu) 4 1/2000 0

THE MÖSSBAUER EFFECT

Chemical Engineering 412

RESULTS YOU CAN COUNT ON

Determination of the boron content in polyethylene samples using the reactor Orphée

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

S8 TIGER Series 2 for ASTM D 6443

RESPONSE OF A NAI(TL) SCINTILLATION DETECTOR IN A WIDE TEMPERATURE INTERVAL

NUCL 3000/5030 Laboratory 2 Fall 2013

LUDLUM MODEL 42-5 NEUTRON BALL CART. August 2015 Serial Number PR and Succeeding Serial Numbers

AlphaVision-5.3. Integrated, Ethernetconnected. spectrometers. 32-bit software for Windows 2000 and XP Professional ORTEC

Nuclear medicine and Radiation technologies

Multi-element process analyzer

Portable gamma and thermal neutron detector using 6 LiI(Eu) crystals

An Improved U-Pu System for Field Pu Measurements

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

Introduction. Principle of Operation

GM Pancake Probe Victoreen Model D

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

Physics 1000 Half Life Lab

Transcription:

Wiper Gold Edition Premium Wipe Test Counter Setting the bar higher

Software - Simplicity, Re-defined Load your wipe into the well and press the button. Your wipe is counted and automatically converted to DPM. If the wipe is above trigger, it is flagged and the contaminating isotope identified - that s all there is to it. Your Time is Valuable Answer a few questions, and we will pre-program the instrument - customized for your department. Your Wiper Gold then arrives ready to use, just plug it in and go...

The Detector Radiation is emitted 360 degrees, yet some manufacturers don t seem to understand that. Minimizing crystal mass below the well has a detrimental effect on counting efficiency - especially at higher energies. We designed it better Well By increasing the crystal mass and thickness below the well (up to 400%), the Wiper Gold captures more counts, making it ideal for 511 PET isotopes. Our design results in 40% more crystal mass than some other well counters. NaI(tl)! crystal With.75 inches of lead shielding (50% more than other wipe counters), lower background readings are achieved without adding external lead. PMT More shielding + greater crystal mass = Lower MDA s, 80% Co57 efficiency and better results with isotopes like F18. The Wiper Gold s crystal design: more crystal mass where it counts - below the sample

Hardware One of the keys to making wipe counting fast, easy and accurate is providing useful isotope identification when a hot wipe is found. A low resolution analyzer hampers performance and can result in false readings and mis-identified contaminants. Other counters use a low resolution analyzer. It s like taking a picture with a cheap camera. With the Wiper Gold s analyzer, results are crystal clear - like a quality high resolution camera. Wipe counters with 64 or even 256 channels just don t have the resolution needed for isotope identification. With such low resolution, you may not be able to distinguish Tc99m from Co57. The Wiper Gold provides superior resolution with 4096 channels. No ifs no buts - just accurate, unmistakeable isotope ID - every time. The answer is clear. Why would you pay more for less?

Say Goodbye to all those Calibration Sources With our proprietary AutoSpect feature, you no longer need to purchase expensive isotope standards for multiple energies. Our unique approach allows the user to count any gamma emitting isotope* and get accurate DPM results automatically. No fudge factors needed, no guess work necessary. Just accurate DPM results automatically and effortlessly. With the Wiper Gold there is no need for multiple sources. * The Wiper Gold can measure any isotope that has gamma or x-ray emissions up to 1 MEV.

For The Physicist Especially for the Physicist, the RSO and Power users: Improved high activity counting - samples over 300,000 CPS may be counted with exceptional linearity. Automatic sample decay correction - with automatic decay correction samples at the end of a batch are as statistically accurate as samples at the beginning of the batch. Advanced MCA Features - Zoom, ROI, PHA, Peak Search, Marking, etc. A full featured MCA, without complicating daily use. Reverse/Future decay correction - decay correct a sample to a previous point in time or a future point in time. Using reverse decay correction, the user can determine what the activity would have been two days, or even two weeks earlier. Sample volume correction - corrects for geometry differences when samples with varying physical volumes need to be counted and compared.

Detector: NaI(tl) drilled well crystal coupled to a high gain, linearity-selected photomultiplier tube. Assembly is hermetically sealed in aluminum housing with an internal mu-metal magnetic shield. Asymmetrical crystal shape provides additional crystal mass below the well for greater efficiency with higher energy isotopes such as F18. Well Dimension: 1.25 inches deep x.669 inches diameter. Shielding: 0.75 inches of virgin lead, extending more than 3.5 inches beyond the bottom of the crystal. High Voltage: Custom engineered Croft-Walton style circuitry with multi-stage gain adjust for ultra-precise software control of calibration. Analyzer: High speed 4096 channel analyzer (12 bit) with automatic dead time correction, pole zero correction and baseline restoration. Integral linearity better than 0.5%. Count rate capability 300,000 CPS. Printer: Optional compact 80 column thermal printer. Specifications Power: 100-240 VAC (Universal, automatically adjusting power supply), 50-60Hz, less than 30 watt consumption. Dimensions/weight: 10.5 W x 8.5 D x 4.75:H (base); 6 D x 10 H (detector). Thirty two pounds.

About LTI Laboratory Technologies, Inc. was established in 1983 as a manufacturer of nuclear instrumentation. Over the years, we have worked closely with many leading diagnostic companies and have become widely regarded as a leading worldwide supplier. When you choose an LTI product, you get much more than quality engineering. You get the full support of our company behind it. With a field service organization of more than 300 technicians across the United States, help is never far away. Our instruments are used worldwide in diverse areas ranging from clinical laboratories to the oil industry to nuclear medicine to the space program. When you choose an LTI product you get the benefit of our vast experience, personal service and product expertise. Distributed by: 217 Dempsey Drive Elburn, IL 60119 800.542.1123 630.365.1000 630.365.9687 fax www.labtechinc.com sales@labtechinc.com