Your Reversed Phase Method

Similar documents
Gemini-NX Performance paired with Axia Technology

The Standard for ph Method Development

AGGREGATE ANALYSIS. Biologics Workflow. by Size Exclusion Chromatography

APPLICATIONS TN Lux Cellulose-2 or -4 Cellulose tris (3-chloro-4-methylphenylcarbamate) or (4-chloro-3-methylphenylcarbamate)

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction

APPLICATIONS TN HPLC Conditions. Lux Cellulose-1 Cellulose tris(3,5-dimethylphenylcarbamate)

Quick and Simple Cleanup for. Medicinal Chemistry. It s BIG.

APPLICATIONS TN Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

35 % OFF HPLC. The Ultimate Guide to

mau 200 ph min

Reversed Phase Solvents

Analysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes

APPLICATIONS TN Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS

Setting the Standard for ph Method Development

synergi Ultra-Performance HPLC The Concept Behind Synergi: Separate the Entire Polarity Spectrum Material Characteristics

Gemini. Second-Generation TWIN-NX Technology. TWIN (Two-In-One) Technology. U.S. Patent No. 7, 563, 367 Setting the Standard for ph Method Development

Setting the Standard for ph Method Development

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Ultra-Performance LC Columns SM

Leave Your Footprint!

Enhance Resolution FOR POLYMER ANALYSIS, Guaranteed *

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

[ Care and Use Manual ]

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

penta-hilic UHPLC COLUMNS

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

ANALYSIS OF BASIC COMPOUNDS

Fluophase and Fluofix Columns

Kromasil Eternity Designed for long life. For use in HPLC and UHPLC

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

Kromasil Eternity Designed for long life

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

penta-hilic UHPLC COLUMNS

Fast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns

Part 2. Overview of HPLC Media

Method Development Kits

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

LC Columns with Liquid Separation Cell Technology

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

1.7µm Fortis C18 UHPLC Columns

Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns

LC Technical Information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

Kromasil Eternity Designed for long life

Fast, Accurate Environmental Testing

PhenogelTM Non-Aqueous GPC/SEC Columns

RP C18 column with feature of a silanol group

ACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

HILIC Method Development in a Few Simple Steps

ColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns

Epic Aromatic Selectivity

Alltech Alltima HP Introduction

Comparison of different aqueous mobile phase HPLC techniques

It s hot! ZIC -chilic

columns IonPac SCS 1 Silica Cation Separator

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Dilution(*) Chromatography

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

InertSustainSwift C8

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

SHARC Separation separation Technology. LC Column with Hydrogen Bonding Based Separation. 65 E. Palatine Rd., Suite 221. SIELC Technologies, Inc.

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

General Principles of HPLC Method Development

STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

4. Place a 20 ml VOA vial in position 1 of the tray. 5. Place a 6 ml C18-E cartridge in position 1 of the carousel.

SHARC Separation separation Technology. LC Column with Hydrogen Bonding Based Separation. 65 E. Palatine Rd., Suite 221. SIELC Technologies, Inc.

UPLC Method Development and Validation

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

The World s Leading. One of. HPLC Columns

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

N α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs)

ChromegaChiral TM CSP Media and Columns

USP 3, 5, 10, 10- PREP

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

Carbon Load % Calculated Bonded Phase Coverage (µmole/m 2 ) Surface Area (m 2 /g)

3µm Fortis C18. Fortis 2.1µm. Increased Efficiency. Scalability and Sensitivity

Next Generation of Phenyl Columns. Chromatography Products.

1.7 m Fortis UHPLC Columns

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

IN QUALITATIVE ANALYSIS,

Definitive EtG/EtS LC-MS/MS Analysis:

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

Dionex IonPac AS28-Fast-4µm column

Thermo Scientific. Anion-Exchange Column

High Performance Liquid Chromatography

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

ChromegaChiral TM CSP Media and Columns

Transcription:

PLC Columns for Your Reversed Phase Method Balanced Non-Polar & Polar Selectivity Strong Non-Polar & Polar Selectivity Strong Polar & Aromatic Selectivity Unique Isomeric & alogenated Selectivity Robust C8 Selectivity

PFP() Choose the Optimal PLC Column for Your Application Choosing the right column can ease method development and result in improved resolution.* Analytes Polar Non Polar Polar/Non-Polar Mixtures Recommended PLC column Synergi Polar-RP Gemini -NX Synergi ydro-rp Stronger non-polar retention Synergi Fusion-RP Balanced non-polar & polar retention For Alternative Selectivity Luna PFP() Selectivity for isomeric, aromatic, and halogenated compounds OR Luna ILIC** For very polar compounds consider ILIC mode Luna PFP() More aromatic selectivity Synergi ydro-rp More hydrophobic selectivity *These are suggestions and individual results may vary, depending on your sample and separation goal. **Contact us for more information on Luna ILIC columns or visit www.phenomenex.com Trademarks Luna and Gemini are registered trademarks of Phenomenex, Inc. SecurityGuard and Synergi are trademarks of Phenomenex, Inc. Waters is a registered trademark, and SymmetryShield is a trademark of Waters Corp. Disclaimer Comparative separations may not be representative of all applications. Subject to Phenomenex Standard Terms & Conditions, which may be viewed at www.phenomenex.com/termsandconditions. 009 Phenomenex, Inc. All rights reserved.

Gemini -NX C8 Robust C8 Performance at p Stable - Mobile phase p directly impacts retention and resolution of most drug compounds. Using Gemini-NX, method development is nearly unlimited due to the advanced column technology that provides wider p stability and longer column lifetime. By using mobile phase p to change the ionization state of your compound, you can increase retention of your compounds. Ionized state Nicotine spends less time interacting with the C8 stationary phase and elutes in the void volume App ID 666 p.8 Charged Analyte + + + O N O - N + O Nicotine in 0. % Formic Acid, p.8 Column: Gemini-NX 5 µm C8 Part No.: 00F-5-E0 Mobile Phase: A: 0. % Formic Acid in Water B: 0. % Formic Acid in Acetonitrile Gradient: A/B (95:5) to (5:95) in 0 min, old for min Flow Rate:.5 ml/min Temperature: Ambient Detection: UV @ 5 nm Sample: Nicotine; pk a 8.5 0 6 8 0 min Neutral state Nicotine has distinct chromatographic behaviors: Increased retention - nicotine spends more time interacting with the stationary phase Sharp peak - single neutral form, well resolved App ID 667 p 0.5 Uncharged Analyte O - O - O - N O - N O O - Nicotine in Ammonium Bicarbonate, p 0.5 Column: Gemini-NX 5 µm C8 Part No.: 00F-5-E0 Mobile Phase: A: 0 mm Ammonium Bicarbonate p 0.5 B: Acetonitrile Gradient: A/B (95:5) to (5:95) in 0 min, old for min Flow Rate:.5 ml/min Temperature: Ambient Detection: UV @ 5 nm Sample: Nicotine ; pk a 8.5 0 6 8 0 min 3

Synergi YDRO-RP Strong Non-polar Selectivity with Polar Retention For sample mixtures that require separation of non-polar and polar analytes, Synergi ydro-rp exhibits very hydrophobic retention compared to most traditional C8 columns, due to unique polar end-capping combined with a densely bonded C8 ligands. Synergi ydro-rp vs. Traditional 5 µm C8 +3 Greater retention, polar selectivity! Increased hydrophobic retention! App ID App ID 5 Columns: Synergi µm ydro-rp 80Å Traditional 5 µm C8 00Å Part No.: 00F-375-E0 Mobile Phase: 0 mm Potassium phosphate, p 7.0 /Methanol (60:0) Flow Rate:.0 ml/min Temperature: C Detection: UV @ 0 nm Sample:. Phenylephrine. Phenylpropanolamine 3. Pseudoepherine. Methylparaben

Synergi FUSION-RP Balanced Non-polar Selectivity with Polar Retention For improved run times for extremely hydrophobic compounds and increased retention for polar compounds, Synergi Fusion-RP provides the right balance for mixtures of non-polar and polar analytes. Synergi µm Fusion-RP vs. Traditional 5 µm C8 Longer Polar Retention 3 Less ydrophobic Retention Balanced retention! 6 8 0 min App ID 80 Columns: Synergi µm Fusion-RP Traditional 5 µm C8 Part No.: 00F--E0 Mobile Phase: 0 mm Potassium Phosphate, p.5 / Acetonitrile (75:5) Flow Rate:.0 ml/min Detection: UV @ 0 nm Sample:. Maleic acid. Chlorpheniramine 3. Triprolidine. Diphenhydramine 3 0 6 8 0 min 5

Synergi POLAR-RP Strong-polar Retention with Aromatic Selectivity ighly polar compounds are difficult to retain on traditional C8 columns. A specialized ether-linked phenyl group gives better selectivity for aromatic compounds while providing maximum polar retention. Synergi µm Polar-RP vs. Waters SymmetryShield C8 Improved selectivity! App ID 55 App ID 85 Columns: Synergi µm Polar-PR Waters 5 µm SymmetryShield C8 Part No.: 00F-336-E0 Mobile 0 mm Potassium phosphate Phase: p 3 / Methanol (50:50) Flow Rate:.0 ml/min Detection: UV @ 30 nm Injection: µl Temperature: C Sample:. Metaproterenol (0. µg). Pindolol (0.6 µg) 3. Metoprolol (0.5 µg). Alprenolol (0.3 µg) 5. Propranolol (0.0 µg) 6. Ethylparaben (0. µg) 6

PFP() Luna PFP() Separate Compounds that are Isomeric, Aromatic, & alogenated When a truly different type of reversed phase selectivity is needed, Luna PFP() is an excellent choice, even under typical C8 mobile phase conditions. A pentafluorophenyl-propyl ligand uses multiple mechanisms of interaction for improved separation of isomers, aromatics, and halogenated compounds. Positional Isomers of alogenated Phenols alogens can radically increase the polarity of a compound, thus decreasing typical retention characteristics. Luna PFP() columns retain, discriminate, and separate halogens easily. Luna 3 µm PFP() 3 5 6 7 8 Baseline separation 0 6 8 0 min 9 0 App ID 696 Luna 3 µm C8() 3 5 6 0 6 8 0 min 7 8 9 & 0 Coelution! App ID 697 Columns: Luna 3 µm PFP() Luna 3 µm C8() Part Nos.: 00F-7-E0 00F-5-E0 Mobile Phase: A: 0. % Formic acid in Water B: 0. % Formic acid in Acetonitrile Gradient: A/B (60:0) to (50:50) in 0 min Flow Rate:.0 ml/min Temperature: C Detection: UV @ 5 nm Sample:.,3-Dimethylphenol.,5-Dimethylphenol 3.,6-Dimethylphenol. 3,-Dimethylphenol 5. 3,5-Dimethylphenol 6.,5-Dichlorophenol 7.,6-Dichlorophenol 8. 3,-Dichlorophenol 9. 3,5-Dichlorophenol 0.,-Dibromophenol Positional Isomers of Methylacetophenone Positional changes on an analyte of interest may effect the compound s dipole moment. This change can be readily noticed by the highly electronegative fluorine (F) atom and other retention mechanisms. Luna 3 µm PFP() mechanisms of interaction provide good resolution of isomers! 3 App ID 698 Luna 3 µm C8() mechanism of interaction unable to resolve isomers! 3 App ID 699 Columns: Luna 3 µm PFP() Luna 3 µm C8() Part Nos.: 00F-7-E0 00F-5-E0 Mobile Phase: Water/ Methanol (50:50) Flow Rate:.0 ml/min Temperature: C Detection: UV @ 5 nm Sample:. o-methylacetophenone. m-methylacetophenone 3. p-methylacetophenone 0 6 8 0 6 8 min 0 6 8 0 6 8 min 7

Ordering Information Gemini -NX 3 μm Minibore Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x.0 50 x.0 x.0* C8 00B-53-B0 00F-53-B0 AJ0-8367 3 μm Analytical Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x.6 50 x.6 x 3.0* C8 00B-53-E0 00F-53-E0 AJ0-8368 for ID: 3.-8.0 mm 5 μm Minibore Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x.0 x.0* C8 00B-5-B0 AJ0-8367 5 μm Analytical Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x.6 50 x.6 50 x.6 x 3.0* C8 00B-5-E0 00F-5-E0 00G-5-E0 AJ0-8368 for ID 3.-8.0 mm Luna PFP() 3 μm Minibore Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x.0 00 x.0 50 x.0 x.0 * PFP() 00B-7-B0 00D-7-B0 00F-7-B0 AJ0-836 3 μm Analytical Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x 3.0 50 x.6 x.0* x 3.0 * PFP() 00F-7-Y0 00F-7-E0 AJ0-836 AJ0-837 3.-8.0 mm 5 μm Analytical Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x 3.0 x.0* PFP() 00F-8-Y0 AJ0-836 5 μm Analytical Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x.6 50 x.6 x 3.0* PFP() 00F-8-E0 00G-8-E0 AJ0-837 for ID: 3.-8.0 mm Synergi.5 µm igh Speed Technology (ST) Columns (mm) Phases 50 x.0 00 x.0 ydro-rp 00B-387-B0 00D-387-B0 Polar-RP 00B-37-B0 00D-37-B0 Fusion-RP 00B-3-B0 00D-3-B0 µm Narrow Bore Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x 3.0 50 x 3.0 x.0* ydro-rp 00F-375-Y0 00G-375-Y0 AJ0-750 Polar-RP 00F-336-Y0 00G-336-Y0 AJ0-6075 Fusion-RP 00F--Y0 00G--Y0 AJ0-7556 µm Minibore Columns (mm) SecurityGuard Cartridges (mm) Phases 30 x.0 50 x.0 75 x.0 50 x.0 x.0* ydro-rp 00A-375-B0 00B-375-B0 00C-375-B0 00F-375-B0 AJ0-750 Polar-RP 00A-336-B0 00B-336-B0 00C-336-B0 00F-336-B0 AJ0-6075 Fusion-RP 00A--B0 00B--B0 00C--B0 00F--B0 AJ0-7556 If Gemini, Luna, and Synergi analytical columns do not provide at least an equivalent separation as compared to a competing column of the same particle size, similar phase, and dimensions, send in your comparative data within 5 days and keep the Luna column for FREE. µm Analytical Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x.6 75 x.6 50 x.6 50 x.6 x 3.0* ydro-rp 00B-375-E0 00C-375-E0 00F-375-E0 00G-375-E0 AJ0-75 Polar-RP 00B-336-E0 00C-336-E0 00F-336-E0 00G-336-E0 AJ0-6076 Fusion-RP 00B--E0 00C--E0 00F--E0 00G--E0 AJ0-7557 for ID: 3.-8.0 mm *SecurityGuard Analytical cartridges require holder, Part No.: KJ0-8 Additional analytical and preparative dimensions available. Contact us or visit www.phenomenex.com Protect Your PLC Column SecurityGuard Cartridge System Extends your PLC column lifetime Won t alter your chromatography Compatible with virtually all PLC columns To learn more about protecting your PLC column investment visit www.phenomenex.com/guard Australia t: 0-98-6 f: 0-98-65 auinfo@phenomenex.com Canada (800) 53-368 (30) 38-7768 info@phenomenex.com Germany 060-58830-0 060-58830- anfrage@phenomenex.com Luxembourg +3 (0)30-8700 +3 (0)30-38379 nlinfo@phenomenex.com Puerto Rico (800) 5-PLC (30) 38-7768 info@phenomenex.com Austria t: 0-39-30 f: 0-39-300 anfrage@phenomenex.com Denmark 8 808 80 665 dkinfo@phenomenex.com Ireland 0 7 505 + 65-50796 eireinfo@phenomenex.com Netherlands 030-8700 030-38379 nlinfo@phenomenex.com United Kingdom 065-50367 065-50796 ukinfo@phenomenex.com Belgium t: +3 (0)30-8700 f: +3 (0)30-38379 beinfo@phenomenex.com France 0 30 09 0 0 30 09 franceinfo@phenomenex.com Italy 05 6375 05 637555 italiainfo@phenomenex.com New Zealand 09-78095 09-78095 nzinfo@phenomenex.com All other countries: Corporate Office USA (30) -0555 (30) 38-7768 info@phenomenex.com www.phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com BR6900509_I 8