Analysis of pharmaceuticals using HPLC with evaporative light scattering detection

Similar documents
Agilent 385-ELSD Evaporative Light Scattering Detector

Agilent 385-ELSD Evaporative Light Scattering Detector

Varian 385-LC. ELSD for Low Molecular Weight Compounds

Agilent 1260 Infinity Evaporative Light Scattering Detector (ELSD)

Varian 380-LC. ELSD for Routine HPLC and GPC Analysis. Key Benefits

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

Evaporative Light Scattering Detector (ELSD)

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

LC and LC/MS Column Selection Flow Chart

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Direct Analysis of Surfactants using HPLC with Charged Aerosol Detection

for Acclaim Mixed-Mode HILIC-1 Column

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

No Chromophore? No Problem! Universal HPLC Detection. The world leader in serving science

Optimizing GPC Separations

Basic Principles for Purification Using Supercritical Fluid Chromatography

Quantitation of Surfactants in Samples by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

Sensitive HPLC Method for Triterpenoid Analysis Using Charged Aerosol Detection with Improved Resolution

A Novel LC-ELSD Method for the Quantification of 2-Deoxy D-Glucose Using HILIC Chromatography

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Analysis - HPLC A.136. Primesep 5 µm columns B.136

with diode array detection

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Optical Isomer Separation Columns and Packing Materials

Nexera UC Unified Chromatography

HPLC Analysis of Non-volatile Analytes Using

Supercritical Fluid Chromatography

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

It s hot! ZIC -chilic

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Charged Aerosol Detection 101

How proteins separate on reverse-phase HPLC

Packings for HPLC. Packings for HPLC

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

Peptide Isolation Using the Prep 150 LC System

Corona Veo the Next Generation Charged Aerosol Detector

Routine MS Detection for USP Chromatographic Methods

Thermo Scientific Acclaim Surfactant Plus Column

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Dilution(*) Chromatography

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Acclaim AmG C18 Column

Discover what you re missing

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

Using the Agilent 1290 Infinity II Multicolumn Thermostat with Extreme Temperatures and Flow Rates

LC MS analysis of metabolites. Basis of Chromatography

A novel approach to the analysis of multivitamin by online supercritical fluid extraction/supercritical fluid chromatography

Introduction to Pharmaceutical Chemical Analysis

Cation Exchange HPLC Columns

LC Technical Information

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Principles of Gas- Chromatography (GC)

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

HPLC Analysis of Nonvolatile Analytes Using Charged Aerosol Detection

CHAPTER 1 Role of Bioanalytical Methods in Drug Discovery and Development

Epic Aromatic Selectivity

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

penta-hilic UHPLC COLUMNS

Pharmaceutical Analysis of API and Counter Ions in Complex Formulations in a Single Injection

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

Shodex TM ODP2 HP series columns

Analysis of Silicone Oils by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

for Acclaim Trinity TM P1

DEMONSTRATING SUPERIOR LINEARITY: THE ACQUITY UPLC PHOTODIODE ARRAY DETECTOR

High Pressure/Performance Liquid Chromatography (HPLC)

State-of-the-art C18 HPLC Columns

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Extraction Process Validation of Isatis Radix

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

HPLC Praktikum Skript

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

Expediting Achiral SFC Method Development Using a Multi-Channel SFC System with MS Detection

Automating Gradient Method Development in Flash Chromatography For Greater Productivity and Minimizing Solvent Use

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

KEYWORDS: Acetaminophen, Doxylamine succinate, Dextromethorphan hydrobromide.

Selecting Detectors for Compounds with No Optical Absorbance

Analysis of Saponins in Spine Date Seed using Agilent ZORBAX Solvent Saver HT (1.8 µm) Columns

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Sepax SRT -C, Zenix -C SEC Phases

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Acclaim Mixed-Mode WCX-1

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Analysis of PEGylated Proteins with Agilent AdvanceBio SEC Columns

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

PolyHYDROXYETHYL Aspartamide for Hydrophilic Interaction Liquid Chromatography(HILIC)

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)

Practical Steps in GPC Method Development

2501 High Performance Liquid Chromatography

for Acclaim Mixed-Mode WCX-1

Luminescence transitions. Fluorescence spectroscopy

Transcription:

Analysis of pharmaceuticals using HPLC with evaporative light scattering detection Application Compendium Author Agilent Technologies, Inc.

Universal detection for pharmaceutical analysis The Agilent 8-ELSD is an advanced evaporative light scattering detector that delivers subambient evaporation down to C, providing maximum sensitivity for compounds with significant volatility below ambient temperature. The 8-ELSD benefits from fast data output rates and extremely low dispersion for fast LC, and delivers a universal response down to the low-nanogram range for truly representative analysis. Reproducibility is better than % for improved consistency of results. The 8-ELSD offers real time gas management that eliminates solvent effects to give a constant response across a gradient. Control and digital data collection come as standard for multivendor platforms so there is no need for an analog to digital converter. On-the-fly adjustment of light source intensity can save time during a run. Being complementary to LC/MS, and offering unrivalled flexibility and sensitivity, the 8-ELSD is the evaporative light scattering detector of choice for pharmaceutical applications. Evaporative light scattering detection involves a three stage process.. Nebulization Using an inert gas stream to form a plume of uniformly sized droplets. Evaporation of the eluent Generating a plume of nonvolatile solute particles. Optical detection Where the intensity of scattered light is proportional to the mass of solute passing through the optical chamber Nebulization Efficient nebulization using low gas flow rates is a feature of the 8-ELSD. Independent nebulizer temperature control and digital gas flow control provide excellent stability and reproducibility. Baseline noise is minimized by the removal of any poorly nebulized eluent through a drain port. Evaporation The nebulized stream passes through an independently temperature-controlled evaporator tube where solvent is removed at low temperature, leaving the less volatile solute particles behind. The 8-ELSD features patented, gasflow control technology with a short evaporator tube that gives an extremely low swept volume for minimal peak dispersion. This provides maximum resolution for high speed separations, which is especially important for work with small columns. Optical detection The solute particles are detected as they pass through the optical chamber. The high power LED and advanced design of the electronics deliver maximum sensitivity. Benefits of ELS Detection Obtain a more uniform response The 8-ELSD is not dependent on a compound s optical properties so it provides a more uniform response than UV-Visible detection, making it the ideal detector for purity analysis or where calibration standards are not available.. Prednisone. Dexamethasone Column: Agilent Polaris C8, 4.6 mm, μm Eluent: Water:Acetonitrile : Flow rate:. ml/min Injection volume: μl ELS detection: Agilent 8-ELSD (neb. = C, evap. = C, gas flow =.4 SLM) UV detection: 8 nm Agilent 8-ELSD UV, 8 nm 4

Achieve superb RSD caffeine injections Excellent reproducibility below % gives reliable and accurate results you can have complete confidence in your data. Column: Agilent Pursuit C8, 4.6 mm, μm Eluent: Water:Acetonitrile 4:6 Flow rate:. ml/min Injection volume: μl ELS detection: Agilent 8-ELSD (neb. = 4 C, evap. = 4 C, gas flow =.4 SLM) 4 Agilent 8-ELSD Achieve fast gradient and steep baselines The excellent baseline stability across steep gradients and low dispersion characteristics combined with fast data output rates makes the Agilent 8-ELSD ideal for fast LC. Sample: Tertiary aminols Column: C8, 4.6 mm, μm Eluent A: Water +. % Formic acid +. % Formic acid Gradient: 9 % B in min Flow rate:. ml/min Injection volume: μl ELS detection: Agilent 8-ELSD (neb. = 4 C, evap. = C, gas flow =. SLM) Agilent 8-ELSD Detect compounds with no UV chromophore ELS detection is necessary for compounds that do not possess a UV chromophore, but require gradient elution, such as cyclodextrins. Cyclodextrins are commonly used with hydrophobic drug molecules to improve the target compound s solubility, stability, bioavailability, and dissolution. Consequently, their characterization is of great importance within the pharmaceutical sector.. alpha-cyclodextrin. beta-cyclodextrin. Ibuprofen Agilent 8-ELSD Column: C8, 4.6 mm, μm Eluent A: Water Gradient: 9 % B in min Flow rate:. ml/min Injection volume: μl ELS detection: Agilent 8-ELSD (neb. = C, evap. = C, gas flow =. SLM) 6 9 UV, 8 nm

Sub-ambient ELS detection Ideal for low molecular weight compounds Achieve sub-ambient detection for semi-volatiles The unique cooled evaporation zone of the Agilent 8-ELSD provides subambient operation to deliver unrivalled detection of low molecular weight compounds not seen by other ELS detectors. Operating the 8-ELSD at C provides better detection of parabens, which are commonly used in pharmaceutical and cosmetic formulations.. Methyl paraben. Ethyl paraben. Propyl paraben 4. Butyl paraben. Heptyl paraben 4 C C Sample: Parabens Column: Agilent Pursuit C8,. mm, μm Eluent A: Water Gradient: 7% B in min, 7-9% B in min Flow rate:. ml/min Injection volume: μl ELS detection: Agilent 8-ELSD (neb. = C, as shown, gas flow =.4 SLM) 9..4.6.8 4 C Obtain an unrivalled uniform response across a gradient The 8-ELSD is unique in its ability to control gas flows during an injection to produce a uniform detector response across a solvent gradient. This realtime benefit offers an alternative approach to mobile phase compensation when quantifying unknowns under gradient conditions. Gas control on Column: Agilent Pursuit C8,. mm, μm Eluent A: Water Gradient: 9% B in min Flow rate:. ml/min Injection volume: μl (every min) Detection: Agilent 8-ELSD (neb. = C, evap. = C) Gas control off 4 6 8 4

Improve signal-to-noise using sub-ambient analysis Polyethylene glycols of low molecular weight are used to improve the aqueous solubility of hydrophobic drugs. PEG 6 is semivolatile with no UV chromophore, so ELS detection is required. The Agilent 8-ELSD, operating at subambient temperatures, can significantly improve the detection of this compound as shown. S/N - 9. S/N - 64 S/N - C (Gas.4 SLM) C (Gas.4 SLM) C (Gas.4 SLM) Column: C8, 4.6 mm, μm Eluent A: Water Gradient: % B in min Flow rate:. ml/min Injection volume:. μl Detection: Agilent 8-ELSD (neb. = C, evap. as shown) 4. Obtain DMSO transparency at C The unique design of the 8-ELSD gives DMSO transparency at low temperatures by increasing gas flow, enabling the detection of fast eluting semi-volatile compounds. This allows faster gradients and increased sample throughput in combinatorial analysis. Column: C8, 4.6 mm, μm Eluent A: Water Gradient: % B in min Flow rate:. ml/min Injection volume: μl Detection: Agilent 8-ELSD (neb. = C, evap. = C, gas flow as shown) 4. Adenosine monophosphate. DMSO. Acetaminophen Time (min) 6 4. Caffeine. Acetanilide 6. Phenacetin.6 SLM.8 SLM. SLM. SLM 4.

Analysis of pharmaceuticals with ELS detection Deliver accurate compositional data The Agilent 8-ELSD s uniform response delivers accurate composition information for pharmaceutical mixtures, such as dexpanthenol and -aminopropanol in eye drops. Column: C8, 4.6 mm, μm Eluent A:.% HFBA in Water Eluent B:.% HFBA in CAN Gradient: 9: A:B Flow rate:. ml/min Injection volume: μl Detection: Agilent 8-ELSD (neb. = C, evap. = 6 C, gas flow =.4 SLM) mv 6 4. -aminopropanol. dexpanthenol 4 Time (min) 6 8 Detect antibiotics with no UV chromophore ELS detection is the ideal choice for the detection of aminoglycoside antibiotics because they are difficult to detect by UV due to their extremely weak chromophore. Antibiotics such as streptomycin and neomycin are extremely important in clinical medicine because of their efficacy and cost. However, owing to their potential toxicity, the accurate quantification of these antibiotics in pharmaceutical and medicinal preparations is vital. Column: C8, 4.6 mm, μm Eluent A:. % Pentafluoropropionic acid (PFPA) in MeOH Eluent B:.% PFPA in 47 mm ammonium formate Gradient: 4: A:B Flow rate:. ml/min Injection volume: μl Detection: Agilent 8-ELSD (neb. = 4 C, evap. = 8 C, gas flow =. SLM) Eliminate the need for derivatization Phenylethylamine (PEA) is a low molecular weight amine that increases dopamine levels in the brain. While substituted phenylethylamines are used in a wide range of drugs from stimulants, hallucinogens, antidepressents and bronchodilators, ELS detection provides a fast and rapid means of analyzing PEAs in pharmaceutical mixtures without the need for derivatization.. Streptomycin. Neomycin Time (min) 8.,6,9 Trioxaundecane. Phenylethylamine Time (min) Column: C8,. mm, μm Eluent A:. % TFA in Water Eluent B:. % TFA in Acetonitrile Gradient: -9 % in min Flow rate:. ml/min Injection volume: μl Detection: Agilent 8-ELSD (neb. = 6 C, evap. = C, gas flow =. SLM) 6

Monitoring pharmaceutical libraries using LC/MS and ELS detection Couple the Agilent 8-ELSD with LC/MS to reveal much greater detail in the analysis of haloperidol and its metabolites The structural information obtained from an LC/MS system is extremely useful for monitoring pharmaceutical libraries. However, for compounds that do not fly well on mass spectrometers, such as haloperidol, the Agilent 8-ELSD will detect these molecules to provide complementary information and more accurate data. The 8-ELSD shows better sensitivity than LC/MS to haloperidol and its metabolites, demonstrating the power of ELS detection in pharmaceutical analysis. Column: Agilent Pursuit XRs C8,. mm, μm Eluent A:. % Formic acid in Water Eluent B:. % Formic acid in Acetonitrile Gradient: in 7 min, 8 in s, hold s, 8 in s Flow rate:. ml/min Injection volume: μl Detection: Agilent 8-ELSD (neb. = 4 C, evap. = 8 C, gas flow =.9 SLM). Haloperidol. Haloperidol metabolite I. Haloperidol metabolite II ( μg of each on column). 7. LC/MS Agilent 8-ELSD. 7. Peak description MS detection (FS) S/N ELS detection S/N ELS detection sensitivity compared to MS detection. Haloperidol,48 7,4 8x. Metabolite I,84 68, x. Metabolite II,46, x 7

Analysis of nutraceuticals with ELS detection Determining the level of betaine in Goji berries Goji berries (or wolfberries) are a traditional Chinese medicine that contains high proportions of polysaccharides, vitamins C & B, amino acids, and betaine. Betaine maintains liver function and reduces levels of homocysteine. It has a weak UV chromophore, which limits its sensitivity by UV detection and prevents gradient elution on account of the low UV wavelength necessary for its detection. The universal response of the Agilent 8-ELSD provides better sensitivity to betaine than UV detection.. Betaine Chinese lycium Betaine standard Column: HILIC, 4.6 mm, μm Eluent A: mm Ammonium acetate, ph 6 Flow rate:. ml/min Injection volume: μl Detection: Agilent 8-ELSD (neb. = C, evap. = 4 C, gas flow =.4 SLM) Detection of triterpene glycosides in black cohosh Triterpene glycosides possess weak or no UV chromophore, which limits their sensitivity by UV detection, especially during gradient elution at low wavelengths (for example, nm). The Agilent 8-ELSD is the ideal detector for these compounds as it provides better sensitivity and baseline stability than UV detection. Column: C8, 4.6 mm, μm Eluent A:.% Formic acid in water Gradient: 4% B in min, 4 6% B in min, 6 % B in min Flow rate:. ml/min Injection volume: μl Detection: Agilent 8-ELSD (neb. = C, evap. = C, gas flow =.4 SLM) UV detection: nm. Cimifugoside. Actein. 7-deoxyactein Agilent 8-ELSD UV, nm Time (min) 6 8

Analysis of hypericin in St John s Wort The efficacy of natural products, such as St John s Wort, is a result of a complex mixture of active compounds. The universal nature of the Agilent 8-ELSD gives better mass balance of the components within St John s Wort and can detect all of the components in a single chromatographic run.. Hypericin. Hyperforin. Adhyperforin Column: C8, 4.6 mm, μm Eluent A:. % Ammonium formate, adjusted to ph. Gradient: 9% B in min, hold min Flow rate:. ml/min Injection volume: μl Detection: Agilent 8-ELSD (neb. = C, evap. = C, gas flow =.6 SLM) Time (min) Determining the level of soflavones in soy protein Isoflavones, such as genistein and daidzein, are found in soybeans and soy products like tofu. These compounds are of particular importance in reducing certain types of cancer. Genistein and daidzein show different UV activity, which creates a difference in their response for the same concentration. In turn, this leads to inaccurate mass balance data for mixtures of isoflavones. The Agilent 8-ELSD provides more accurate mass balance data compared to UV, which gives a better representation of isoflavones in complex soy mixtures.. Daidzein. Genistein Time (min) Column: C8, 4.6 mm, μm Eluent A: 88// Water/MeOH/ % Acetic acid Eluent B: 98/ MeOH/% Acetic Acid Gradient: % B in min, % B in 8 min, 7% in 6 min, 7 % in. min Flow rate:. ml/min Injection volume: μl Detection: Agilent 8-ELSD (neb. = C, evap. = C, gas flow =.6 SLM) 9

Analysis of excipients with ELS detection Universal analysis of nonionic surfactants Tween, or polysorbate, is a nonionic surfactant that effectively suppresses unspecific reactions between antibodies, antigens and other molecules. It is also used as a solubilizer in membrane chemistry and for density centrifugation of viruses. The absence of a usable UV chromophore and the requirement for gradient elution often mean that neither refractive index (RI) nor UV detection can be used. The Agilent 8-ELSD does not rely on the optical properties of a compound, making it the only choice for these types of excipients. Time (min) 6 Sample: Tween at mg/ml Column: PLRP-S Å, 4.6 mm, μm Eluent A: Water Gradient: % B in min Flow rate:. ml/min Injection volume: μl Detection: Agilent 8-ELSD (neb. = C, evap. = C, gas flow =.6 SLM) 7 Cetrimide Easy analysis of cationic surfactants Cationic surfactants, such as cetrimide (alkyltrimethylammonium bromide), are typically used as antiseptic agents or detergents in fabric softeners, corrosion inhibitors and cosmetic products. Cetrimide is also a common ingredient of shampoos for treating seborrhoea and psoriasis. The 8-ELSD provides a quick and easy method for detecting these types of compounds without the need for chemical derivatization. ELS detection is more sensitive than RI detection providing lower detection levels while its gradient compatibility allows rapid separation of complex surfactant mixtures. mv 4 Sample: Cetrimide Column: C8, 4.6 mm, μm Eluent A:.% HFBA in Water Eluent B:.% HFBA in Acetonitrile Gradient: 9: A:B Flow rate:. ml/min Injectionvolume: μl Detection: Agilent 8-ELSD (neb. = C, evap. = 6 C, gas flow =.4 SLM) Time (min) 6 8

Determination of PEG using SFC/ELSD Supercritical fluid chromatography (SFC) provides faster, higher resolution chromatography compared to HPLC. Consequently, SFC can increase throughput within a pharmaceutical or bioanalytical laboratory where a large number of potential drug compounds are screened. ELS detection is a complementary detection technique for SFC because of the gaseous nature of the mobile phase. Using SFC/ELSD, evaporation of the eluent is not required as the mobile phase is volatilized during nebulization. Unlike flame ionization (FID), which is the common universal detector for SFC, the Agilent 8-ELSD is not affected by typical organic modifiers, such as methanol. Unlike most ELS detectors, the 8-ELSD comes with a heated nebulizer as standard, which is required for SFC operation, and so the 8-ELSD requires no modification for SFC use. The benefits of SFC/ELSD are highlighted with the high resolution separations of different polyethylene glycol samples. 6 7 6 4 counts 4 4 counts counts PEG 4 4 Time (min) PEG 6 4 Time (min) PEG 4 Time (min)

www.agilent.com/chem/elsd Agilent Technologies, Inc., Published in USA, A, 99-94EN