Magee Scientific Aethalometer

Similar documents
Monique Teich et al. Correspondence to: Hartmut Herrmann

ACTRIS Workshop on the Reference method for Multi-Wavelength Absorption

MULTI-WAVELENGTH OPTICAL CALIBRATION OF THERMAL/OPTICAL ANALYZER AND

Choosing the proper technique for measuring the particle light absorption

Results of the Ambient Air Experiments during the EUSAAR 2009 Absorption Photometer Workshop (Aethalometer)

PSAP corrections. Observations Based Research. OBR Technical Note No th August Kate Turnbull. Amendment to MRF Technical Note No.

Photoacoustic and filter measurements related to aerosol light absorption during. the Northern Front Range Air Quality Study (Colorado 1996/1997)

John G. Watson Judith C. Chow Mark C. Green Xiaoliang Wang Desert Research Institute, Reno, NV

Supplement of The single-particle mixing state and cloud scavenging of black carbon: a case study at a high-altitude mountain site in southern China

Supplement of Multi-wavelength optical measurement to enhance thermal/optical analysis for carbonaceous aerosol

Measurements of continuous spectra of atmospheric absorption coefficients from UV to NIR via optical method

A study on characterization, emission and deposition of black carbon over Indo- Gangetic Basin

Technical Note A Quantification and NIST Traceability of Micromatter Thin Film Standards for XRF Analysis. Version March 16, 2017

Traceable UV-Vis Reference Materials

The Plus for your lab!

Chemical mass closure of atmospheric aerosol collected over Athens, Greece.

Aerosol monitoring at multiple locations in China: contributions of EC and dust to aerosol light absorption

WCCAP Report Absorption Photometer Workshop 2007

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

Production of particulate brown carbon during atmospheric

Aerosol Composition and Radiative Properties

Standardisation of Particulate and Aerosol Measurements. Hanspeter Andres

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

Review of the IMPROVE Equation for Estimating Ambient Light Extinction

Clean Air Action Days Anti-Idling Campaign Monitoring Report DRAFT

European aerosol phenomenology-5: climatology of black carbon optical properties at 9 regional background sites across Europe

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

The Fundamentals of Moisture Calibration

INTERNATIONAL OLIVE COUNCIL

Constrained two-stream algorithm for calculating aerosol light absorption coefficient from the Particle Soot Absorption Photometer

Formaldehyde Fluorescent Detection Kit

Improvement of traceability in the field of mass concentration measurements of particles in aerodisperse media carried out in the Russian Federation

Characterization of excimer laser ablation generated pepsin particles using multi-wavelength photoacoustic instrument

Infrared Temperature Calibration 101 Using the right tool means better work and more productivity

HOW ADVANCED PYROMETERS INCREASE THERMAL PROCESS REPEATABILITY AND PRODUCT QUALITY

Supporting Information

Humidity Calibration Solutions

5. Light Extinction In The Desert Southwest

STANDARD PROCEDURE: NWSP R2 (15) Polyacrylate Superabsorbent Powders Determination of the Particle Size Distribution by Sieve Fractionation

Lab 4 Major Anions In Atmospheric Aerosol Particles

UV-Vis optical fiber assisted spectroscopy in thin films and solutions

Aerosol Optical Properties

ActiPix SDI300 Surface Dissolution Imaging System

Correction for a measurement artifact of the Multi-Angle Absorption Photometer (MAAP) at high black carbon mass concentration levels

Why is the sky blue?

CALIBRATION CERTIFICATE # 503

Aerosol Characteristics at a high-altitude station Nainital during the ISRO-GBP Land Campaign-II

610,- KERN ADB. Analytical balances. Quick-Finder Analytical balances. Large glass draught shield with 3 sliding doors

SPECTROPHOTOMETERS. Visible and UV-Visible

How good are our models?

Certificate. Standard Reference Material Near-Infrared Wavelength/Wavenumber Reflection Standard. ), 1.30 % samarium oxide (Sm 2

Model 2300XP PSL & Process-Particle Wafer Deposition System

2 April 2004 Copenhagen, Denmark

LP PYRA Installation and Mounting of the Pyranometer for the Measurement of Global Radiation:

ARTICLE IN PRESS. Journal of Aerosol Science

Automated determination of the uniformity of dosage in quinine sulfate tablets using a fiber optics autosampler

Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry

An Introduction to Ultraviolet-Visible Molecular Spectrometry (Chapter 13)

Optical Measurement and Aerosol Filter Loading for Climate Studies (Aethalometer)

Comparing the Microlab 600 to Volumetric Glassware and Air Displacement Pipettes. January 2013

Lecture 26. Regional radiative effects due to anthropogenic aerosols. Part 2. Haze and visibility.

Nucleic Acid Quantitation in Microplates

Technical Procedure for General Laboratory Equipment

REPORT issued by an Accredited Testing Laboratory

Introduction to Fourier Transform Infrared Spectroscopy

AMMS-100 Atmospheric Metal Monitoring System

Response to Reviewer s comments

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

CERTIFICATE OF. Single Analyte Custom Grade Solution. ICP Assay NIST SRM 3120a Lot Number: Calculated NIST SRM Lot Number: See Sec. 4.

6.5 Interrelationships of Fine Mass, Sulfur and Absorption Daily Scatter Plots Shenandoah National Park

Humidity Calibration Solutions

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A

ANALYSIS CERTIFICATE OF

Supplementary Table 1. Geometry and flow rate of the individual components of the aerosol sampling system used in the A-FORCE 2013W campaign.

Studies to develop certified reference material to calibrate spectrophotometer in ultraviolet region

Supplementary Methods: Determination of the spectral

CERTIFICATE OF. Single Analyte Mass Spec Solution ± 0.1 µg/ml g/ml (measured at 20 ± 4 ºC)

Evaluating the functionality of Eppendorf BioPhotometer and Eppendorf BioSpectrometer using a Secondary UV-VIS Filter Set

PARTICULATE MATTER SIZE DISTRIBUTION MEASUREMENTS AT AKROTIRI STATION, CRETE, GREECE

Results of the inter-laboratory comparison exercise for TC and EC measurements (ref.: OCEC ) SUMMARY 2 1 ORGANIZATION 4

HARP Assessment of Uncertainty

Instrument Inter- Comparison Report

COPLEY S C I E N T I F I C. A multi-function aerosol system with aerosol generation, classification and monitoring capabilities for:

Spectral optical properties of long-range transport Asian dust and pollution aerosols over Northeast Asia in 2007 and 2008

Applications Note 228 September 2010

Projects in the Remote Sensing of Aerosols with focus on Air Quality

INTERNATIONAL STANDARD

Geometric Considerations in the

Model TS105-10L5.5mm Thermopile Sensor

Optical Characterization of PV Glass Coupons and PV Modules Related to Soiling Losses

Single Analyte Mass Spec Solution ± µg/ml g/ml (measured at 20 ± 1 ºC) METHOD NIST SRM# SRM LOT# Calculated See Sec. 4.

PARTICLE SIZE ANALYTICAL RANGES AND APPLICABILITY. m mm (10-6 m) nm (10-9 m)

WWRP Implementation Plan Reporting

RADIOMETER-BASED ESTIMATION OF THE ATMOSPHERIC OPTICAL THICKNESS

Ultraviolet-Visible and Infrared Spectrophotometry

ATOC 3500/CHEM 3152 Week 9, March 8, 2016

Ozone cross-sections (Hartley band) Progress towards new accurate values

1 Fundamentals of Lidar

Renewal of the gage-block interferometer at INRIM

STUDIES ON BLACK CARBON (BC) VARIABILITY OVER NORTHERN INDIA

Transcription:

Magee Scientific Aethalometer Optical Transmission Analysis of NIST Reference Material 8785 and Neutral Density Filters www.mageescientific.com Berkeley, Ljubljana, July 2014 www.mageescientific.com Page 1

Magee Scientific Optical Transmissometer Optical Transmission Analysis of NIST Reference Material 8785 and Neutral Density Filters www.mageescientific.com Berkeley, Ljubljana, July 2014 www.mageescientific.com Page 2

Optical Transmission Analysis of NIST Reference Material 8785 and Neutral Density Filters for calibration and validation of the Magee Scientific Aethalometer and Magee Scientific Optical Transmissometer The Optical Transmissometer is an instrument which measures the attenuation of light transmitted through a sample of aerosol collected on a filter, relative to a blank filter. In the great majority of cases, this optical attenuation is due to absorption by the Black Carbon (BC) component of the aerosol. This attenuation may be converted to a surface mass loading density of BC (expressed, for example, in units of µg/cm 2 ) using a filter-specific Mass Absorption Coefficient. This provides a static analysis of the BC content of a previously-collected sample. The Aethalometer is an instrument which performs a dynamic, real-time measurement of the concentration of Black Carbon ( BC ) aerosols in a sampled air stream, by measuring the rate of increase in optical absorption of the aerosol deposit on a filter spot. The data output is expressed in units of [BC mass] per [volume of sampled air], for example µg/m 3. The calibration of these methods is based upon the determination of the relationship between the optical measurement of Attenuation ( ATN ), and a measurement of the mass of a specified form of carbon in the sample. While the optical measurement may be referenced to traceable photometric standards, chemical determinations of carbon mass are method-dependent. www.mageescientific.com Page 3

Neutral Density Filter Reproducibility Validation Process The reproducibility of the optical attenuation method employed by the Aethalometer and Optical Transmissometer may be validated by the use of Neutral Density Filter Validation Kits for each instrument. These kits consist of elements of Neutral Density optical filter glass, with stable optical absorbances that may be referenced back to traceable photometric standards. These kits are used to verify that the optical performance of the instrument is constant with time, relative to its original manufacturing certification. Figure 1: Neutral Density Optical Filter Kit for OT21 Optical Transmissometer Figure 2: Neutral Density Optical Filter Kit for AE33 Aethalometer www.mageescientific.com Page 4

The reproducibility validation procedure consists of inserting the Neutral Density elements into the optical path of the instrument, and recording the measured Optical Attenuation at the multiple analytical wavelengths. Each individual Neutral Density glass element is described by a nominal value of optical density at its time of manufacture. Due to variations in the manufacturing processes, the actual optical densities of the elements may differ from their nominal labels. However, the glass material is stable, and the Neutral Density validation process is based upon determining that the response of the instrument to the insertion of successive elements is stable and reproducible. The ND Validation Process is a reproducibility check, not a Calibration The Neutral Density Optical Filter validation process is not a Calibration per se: it assures the user that the analytical performance of the instrument is reproducible and unchanged from its date of manufacture. www.mageescientific.com Page 5

Optical Transmission Analysis of Standard Reference Materials The absorption of light transmitted through a deposit of aerosol particles collected on a fibrous filter has been studied by many authors, for example Rosen and Novakov, (1983). This absorption can be attributed to the carbonaceous component of the aerosol (Rosen et al., 1978), in almost all atmospheres except those unusually affected by mineral or inorganic dusts (Hansen et al., 1993). The relationship between the Optical Attenuation measurement and the thermalchemical determination of the mass of certain fractions of carbon in the sample has been studied extensively and reported in the literature. The definitive original reference is Gundel et al., (1984). The procedures and results described therein serve to define Black Carbon, in terms of both chemical procedures and optical analysis. An example of more recent work is Ahmed et al., (2009). At increasing loadings, the optical attenuation measurement is subject to gradual saturation according to the well-known filter loading effect (Bond et al., 1999; Weingartner et al., 2003; Virkkula et al., 2007; Park et al., 2010). The U.S. National Institute of Standards and Technology (NIST) created Standard Reference Material 8785, being uniform deposits of urban dust collected on 37-mm. diameter quartz fiber filter disks, in varying densities. Each filter is weighed to report the total mass of urban dust collected on the filter. Multiple analyses of the dust were performed to determine its content of elemental and organic carbon, as defined by instrument-specific thermal-optical analysis protocols (Klouda et al., 2005). The analyses using the IMPROVE thermal-optical protocol showed that the EC content of the urban dust material was 11.1% ± 3.5% by mass. www.mageescientific.com Page 6

We measured the Optical Attenuation of twelve SRM 8785 filters relative to a blank filter, using the OT21 Optical Transmissometer analyzing at a wavelength of 880 nm. The SRM 8785 filter samples were of identical composition: but contained different amounts of deposited material, determined gravimetrically and reported as total mass for each filter. The uncertainty over replicate optical measurements was ±1 ATN unit. ATN values ranged from 119 ±1 to 197 ±1, while the EC surface loading density according to the NIST analysis data ranged from 7.8 µg/cm 2 ±2.6 µg/cm 2 to 29.8 µg/cm 2 ±9.4 µg/cm 2. The optical analysis of NIST filters is a re-enactment of the original calibration which defines Black Carbon Measurement of the relationship between ATN and the surface loading density of EC is an independent re-enactment of the original definitive calibration by Gundel et al. This process is accessible to present users through the ongoing availability of Standard Reference Material 8785 from the U.S. National Institute of Standards and Technology. www.mageescientific.com Page 7

Measurement Results The blue data points in Figure 3 show the relation between Optical Attenuation measured at 880 nm (ATN) versus the manufacturer s nominal label value of optical density (specified at 550 nm) for the Neutral Density glass elements used in the Validation Kit. Since the validation process is based upon reproducibility rather than absolute values, the deviation of the points from perfect linear proportionality as suggested by the blue trend-line are unimportant. The red data points show the relation between Optical Attenuation measured at 880 nm (ATN) versus the surface loading mass density of Elemental Carbon (EC), for samples of NIST Standard Reference Material 8785. The red trend-line shows a calculation of ATN versus EC using a Mass Absorption Coefficient ( σ ) of 16.6 m²/g, with the saturation being represented by a loading parameter ( k ) of 0.0045 in the equation ATN = (1-exp-( k B σ)) / k (c.f. Gundel) This value (16.6 m²/g, σ ) for the Mass Absorption Coefficient (sometimes termed Specific Attenuation ) has been used in the Aethalometer since the earliest production of instruments analyzing at 880 nm. The value of the loading compensation parameter ( k ) has been shown to be highly variable, depending on aerosol aging and composition (Drinovec et al., 2013). The value of 0.0045 used in the fit to the data shown in Figure 3 is within the central range of values expected for an aerosol of this nature. These results show that the measurement of Optical Attenuation as used in the Optical Transmissometer and the Aethalometer may have their reproducibility validated by the use of stable Neutral Density optical elements; and that these results may be related to the thermal-chemical determination of Elemental Carbon mass on Standard Reference Material samples available from the National Institute of Standards and Technology. This relationship between a photometrically-traceable measurement of optical absorption; versus mass of carbon on a Standard Reference Material; serves to define the material named Black Carbon, and to calibrate the response of the Aethalometer and the Optical Transmissometer. www.mageescientific.com Page 8

Figure 3: Analytical results from measurements. Y-axis: Optical Attenuation measured at 880 nm using the Model OT21 Optical Transmissometer; Upper X-axis: Nominal optical density (at 550 nm) of glass elements; Lower X-axis: Elemental Carbon content of SRM 8785 filters, reported by NIST using the IMPROVE thermal-optical analysis protocol. www.mageescientific.com Page 9

References Ahmed, T., V. A. Dutkiewicz, A. Shareef, G. Tuncel, S. Tuncel, and L. Husain, Measurement of Black Carbon (BC) by an optical method and a thermal-optical method: Intercomparison for four sites, Atmos. Environ. 43, p. 6305-6311, (2009) Bond, T. C., T. L. Anderson, and D. Campbell, Calibration and intercomparison of filter-based measurements of visible light absorption by aerosols, Aerosol Sci. & Technol., 30, p. 582-600, (1999) Drinovec, L., G. Močnik, J.-E. Petit, J. Sciare, O. Favez, P. Zotter, R. Wolf, A. S. H. Prévôt, and A. D. A. Hansen, Indication of aerosol aging by optical absorption properties, presented at AAAR Annual Conference, (2013); paper in press. Gundel, L. A., R. L. Dod, H. Rosen and T. Novakov, The relationship between Optical Attenuation and Black Carbon concentration for ambient and source particles, Sci. Total Environ. 36, p. 197-202, (1984) Hansen, A. D. A., V. N. Kapustin, V. M. Kopeikin, D. A. Gillette, and B. A. Bodhaine, Optical absorption by Aerosol Black Carbon and dust in a desert region of Central Asia, Atmos. Environ. 37A, p. 2527-2531, (1993) Klouda, G. A., J. J. Filliben, H. J. Parish, J. C. Chow, J. G. Watson and R. A. Cary, Reference Material 8785: Air Particulate Matter on filter media, Aerosol Sci. & Technol., 39, p. 173-183, (2005) Park, S. S., A. D. A. Hansen and S. Y. Cho, Measurement of real time black carbon for investigating spot loading effects of Aethalometer data, Atmos. Environ. 44, p. 1449-1455, (2010) Rosen, H., A. D. A. Hansen, L. Gundel and T. Novakov, Identification of the optically absorbing component in urban aerosols, Appl. Opt. 17, p. 3859-3861, (1978) Rosen, H., and T. Novakov, Optical transmission through aerosol deposits on diffusely reflective filters: a method for measuring the absorbing component of aerosol particles, Appl. Opt. 22, p. 1265-1267, (1983) www.mageescientific.com Page 10

Virkkula, A., T. Mäkelä, R. Hillamo, T. Yli-Tuomi, A. Hirsikko, K. Hämeri, and I. K. Koponen, A simple procedure for correcting loading effects of Aethalometer data, JAWMA 57, p. 1214-1222, (2007) Weingartner, E., H. Saathof, M. Schnaiter, N. Streit, B. Bitnar, and U. Baltensperger, Absorption of light by soot particles: determination of the absorption coefficient by means of Aethalometers, J. Aerosol Sci. 34, p. 1445-1463, (2003) www.mageescientific.com Page 11

For Further Information: www.mageescientific.com www.aerosol.si In Europe, Asia, and Africa, please contact: Aerosol d.o.o., Kamniška 41, SI-1000 Ljubljana, Slovenia, EU tel: +386 59 191 220 fax: +386 59 191 221 In the US, please contact: Magee Scientific Corp., 1916a M.L. King Jr. Way, Berkeley CA 94704, USA tel: +1 510 845 2801 fax: +1 510 845 7137 or the distributor responsible for your country. www. mageescientific. com www. aerosol. si Berkeley, Ljubljana, July 2014 www.mageescientific.com