Application of Bio-SPME for the Enrichment of Illicit Phenethylamine and Cathinone Compounds from Biological Samples

Similar documents
Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Solid Phase Micro Extraction (SPME) of Opiates from Urine: Coupling SPME and DESI-MS/MS Detection

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Chemical Analysis Problem

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

Investigation of retention mechanisms in HILIC chromatography: Important considerations for robust method development

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Shodex TM ODP2 HP series columns

Determination of 32 Cathinone Derivatives and other Designer Drugs in Serum by Comprehensive LC/Triple Quadrupole/MS/MS Analysis

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

[ Care and Use Manual ]

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Reversed Phase Solvents

Solid Phase Extraction Method Development Tips and Tricks

Analysis of Cannabinoids and Amphetamines in Serum by RRLC/Triple Quadrupole Mass Spectrometry Using a Multimode Ion Source. Application.

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Development of analytical methods for Catecholamines, Metanephrines and related metabolites in urine and plasma matrices

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Appendix II- Bioanalytical Method Development and Validation

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

Silanol. Groups Liquid Chromatography

Methods Development Process for Bioanalysis" Stuart Coleman March 22, 2007

Liquid Chromatography

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Chromatographic Methods: Basics, Advanced HPLC Methods

Highly sensitive quantitative analysis of Felodipine and Hydrochlorothiazide from plasma using LC/MS/MS

Strategies for the Analysis of Therapeutic Peptides in Biofluids by LC-MS/MS. Lee Goodwin

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method

Breaking the speed limit: Fast, high-resolution peptide and tryptic digest separations using fused-core particles

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Highly sensitive and rapid analysis of synthetic dyes in sea food by LC/MS/MS

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

Supporting Information

Development for SPE. Ron Majors Senior Chemist, CSD Joan Stevens SPE Application Chemist October 2009

Comparison of different aqueous mobile phase HPLC techniques

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Application Note. Abstract. Authors. Forensics

Sample Prep Options for GC users

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

Trends in Method Development for HPLC and UHPLC... the movement toward using solid-core particles

Method Development with ZirChrom's Ion Exchange Phases

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

Part 2. Overview of HPLC Media

Abstract. Experimental Sample Preparation

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Sepax SRT -C, Zenix -C SEC Phases

OPTIMISATION OF SOLID PHASE MICROEXTRACTION (SPME) CONDITIONS FOR HEADSPACE ANALYSIS OF ORGANOPHOSPHATE PESTICIDES IN WHOLE BLOOD

LC Technical Information

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Too Polar for Reversed Phase What Do You Do?

Detection of 9-tetrahydrocannabinol ( 9-THC) in human urine by Solid Phase Extraction and HPLC.

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Application Note. Edgar Naegele. Abstract

How proteins separate on reverse-phase HPLC

Advantages of polymerbased. an alternative for ODS

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Introduction to Pharmaceutical Chemical Analysis

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Ultrafast Analysis of Methadone and Metabolite EDDP in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Acclaim Mixed-Mode WCX-1

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

HPLC & LC-MS. Techniques to Improve Speed, Resolution and Sensitivity without Investing in Capital Equipment

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

It s hot! ZIC -chilic

Troubleshooting Liquid Chromatographic Separations: Avoiding Common Issues through Informed Method Development Practices

A High Sensitivity Dual Solid Phase Extraction LC-MS/MS Assay for the Determination of the Therapeutic Peptide Desmopressin in Human Plasma

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Packings for HPLC. Packings for HPLC

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

Certified Reference Material - Certificate of Analysis Methylone, Primary Standard

Certified Reference Material - Certificate of Analysis

+ butanal + 2-picolineborane. + acetic acid. + butanal + 2-picolineborane. + acetic acid

A New Polymer-based SPE Sorbent to Reduce Matrix Effects in Bioanalytical LC-MS/MS

The Theory of HPLC. Ion Pair Chromatography

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

Transcription:

Application of Bio-SPME for the Enrichment of Illicit Phenethylamine and Cathinone Compounds from Biological Samples Craig R. Aurand 1, Robert Shirey 1, Leonard Sidisky 1 Janusz Pawliszyn 2, and Yong Chen 1 1 Supelco, Div. of Sigma-Aldrich Bellefonte, PA 16823 USA 2 Department of Chemistry University of Waterloo Waterloo, ntario, Canada T412079 sigma-aldrich.com

Introduction Recently the field of illicit drug testing has been met with a changing environment with the rapid development of unregulated designer and synthetic compounds. f most concern has been the development of a class of phenethylamine and cathinone compounds being marketed as Bath Salts, Jewelry Cleaner or Plant Food. Though sold as not for human consumption, these compounds are reported to generate stimulating effects similar to that of methamphetamine, heroin and MDMA. For a period of time, these compounds could be acquired legally through the internet and head shops because of no direct legal control. In the US, both state and local governments have instituted bans on the sale of these Bath Salt compounds. The difficulty in testing of the Bath Salts for forensic testing facilities is the fact these compounds are not detected under normal ELISA testing methods; additional more specific LC/MS methods are necessary. 2

Introduction (contd.) The following presentation demonstrates the implementation of Biocompatible Solid Phase Microextraction (Bio-SPME) for the enrichment of a set of illicit Bath Salts directly from plasma in an effort to explore the utility and unique selectivity of these newly developed sampling devices. The uniqueness of these devices derives from the embedded functionalized media of the Bio-SPME fibers for use in targeted small molecule enrichment from complex biological matrices. Bio-SPME Tippets prepared in a 96-tip array were utilized for the enrichment of nine illicit Bath Salts from plasma samples. Bio-SPME fibers functionalized with mixed mode hydrophobic and cation exchange particles were employed for selective enrichment of the Bath Salts. After enrichment, the Bio-SPME Tippets were then directly desorbed in a 96- well plate for direct LC/MS TF analysis. Key parameters that impact analyte extraction efficiency, such as sample ph and extraction time were explored along with the impact of biological sample. In addition to extracted analyte, overall sample matrix was also monitored and compared with typical dilution/precipitation techniques. 3

Figure 1. Bio-SPME Tippet Configuration Coated Fiber Pipette Tip 4

Figure 2. Adsorption Mechanism on Bio-SPME Extraction Metal Core Analyte Adsorption Embedded Functionalized Particles Biofluid well Extraction Time 5

The adsorption mechanism for Bio-SPME is based upon Flick s Law, where differential migration exists between analytes in solution and analytes that partition into the fiber coating. Bio-SPME is not an exhaustive technique and extraction is governed by distribution constants dependent on an analytes affinity for the coating as compared to the sample matrix. After a given amount of time, an equilibrium is achieved between the concentration of analytes in the matrix and the fiber coating. Concentration of analyte in stationary phase compared to concentration of analyte in solution: K = n s /V 1 C 2 K = Distribution constant n s = Moles of analyte in stationary phase V 1 = Volume of stationary phase C 2 = Final analyte concentration in solution 6

Experimental Bath Salt Analytes NH NH Butylone Monoisotopic Mass = 221.105193 Da Cerilliant B-045 NH MDPV Monoisotopic Mass = 275.152144 Da Cerilliant M-146 N NH Methylone Monoisotopic Mass = 207.089543 Da Cerilliant M-140 NH Ethylone Monoisotopic Mass = 221.105193 Da Cerilliant E-071 H 3 C Mephedrone Monoisotopic Mass = 177.115364 Da Cerilliant M-138 H 3 C Methedrone Monoisotopic Mass = 193.110279 Da Cerilliant M-147 NH F NH NH F 4-Fluoromethcathinone Monoisotopic Mass = 181.090292 Da Cerilliant F-015 3-Fluoromethcathinone Monoisotopic Mass = 181.090292 Da Cerilliant F-016 Buphedrone Cerilliant B-047 7

Figure 3. HILIC Separation of Bath Salts x10 1 8.5 8 7.5 7 6.5 6 5.5 5 4.5 4 3.5 +ESI EIC(178.1200, 182.1000, 194.1100, 208.0900...) Scan Frag=175.0V 041012007.d 1 1 1.768 2.100 2.730 3.212 Analyte rt MDPV 1.7 Buphedrone 2.1 3-fluoromethcathinone 2.5 Butylone 2.7 Ethylone 3.2 3-fluoromethcathinone 3.5 Mephedrone 4.3 Methylone 5.0 Methedrone 5.6 3 2.5 2 3.527 4.357 5.004 5.668 1.5 2.581 1 0.5 0-0.5 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6 2.8 3 3.2 3.4 3.6 3.8 4 4.2 4.4 4.6 4.8 5 5.2 5.4 5.6 5.8 6 6.2 6.4 6.6 6.8 Counts (%) vs. Acquisition Time (min) system: Agilent 1290 Infinity with 6210 TF column: Ascentis Express HILIC, 10 cm x 2.1 mm, 2.7 µm (53939-U) mobile phase: 5 mm ammonium formate (98:2 acetonitrile:water) flow rate: 0.6 ml/min. temp.: 35 ºC system pressure: 127 bar injection: 1 µl MS det.: ESI+, 100-1000m/z, 8

Figure 3. HILIC Separation of Bath Salts (contd.) Analyte rt MDPV 2.0 Buphedrone 2.2 3-fluoromethcathinone 2.7 Butylone 2.9 Ethylone 3.4 3-fluoromethcathinone 3.7 Mephedrone 4.6 Methylone 5.2 Methedrone 6.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 Time (min) 9

Table 1. Log D and pka 1 Values for Bath Salts Evaluated Analyte Log D ph 3.0 Log D ph 7.0 pka 1 Methylone -3.49-1.21 7.74 Ethylone -2.98-0.71 7.75 Butylone -2.98-0.7 7.74 Methedrone -2.55-0.07 7.48 Mephedrone -2.4 0.12 7.41 3-fluoromethcathinone -2.46 0.22 7.14 4-fluoromethcathinone -2.24 0.4 7.14 Buphedrone -2.2 0.49 7.14 MDPV -0.67 1.01 8.41 The charge state of an analyte will impact the efficiency of the extraction, particularly when using a mixed mode ion-exchange material. It is important the analytes are fully ionized in solution to increase the availability for ionexchange to take place with the ionic site of the stationary phase. Table 1 depicts the affect of ph on the Log D value of the analytes, as ph decreases all of the Bath Salts become more hydrophilic, thus making them less likely to partition from an aqueous environment. At lower ph, these analytes are less likely to extract by partitioning as in standard reversed-phase modes. The first portion of this study is to evaluate the ph affect on analyte extraction using the Bio-SPME mix mode fiber. Here ph controlled buffer solutions were spiked with Bath Salts and extracted as described in Table 2. 10

Table 2. Bio-SPME Buffer Extraction Conditions Fiber : Mixed mode Lot 1738-77, Strong Cation Exchange/C18 silica in tippets Conditioning: 15 30 min. in 50% methanol-water Sample ph3 Buffer solution ph 3 water ph adjusted to ph 3.2 with formic acid, spiked to 200 ng/ml with Bath Salts Sample ph7 Buffer solution ph 7 10 mm ammonium formate ph 7, spiked to 200 ng/ml with Bath Salts Extraction: 15 min. from 96-well plates 1 ml volume, 750 µl of sample per well Desorption: 60 min. in 150µL methanol with 0.5% NH 4 H (28% solution) in 300 µl volume 96 well plate Drying step: 60 min. at 40 C under a blanket of nitrogen Reconstitution: 50 µl of methanol and mixed for 2 min. on plate shaker, rapid speed 11

Figure 4. Extraction from Buffered Water, ph Effect 50.0 45.0 40.0 buffer ph 3 buffer ph 7 35.0 30.0 25.0 20.0 15.0 10.0 5.0 0.0 MDPV buphedrone 3-FMC butylone ethylone 4-FMC mephedrone methylone methedrone 12

ph Study Summary As described in Figure 4, the sample ph dramatically influences the extraction efficiency of the Bath Salts. Under neutral ph7 condition, the analytes are partially charged resulting in a greater influence from hydrophobic extraction with the mixed mode surface. Under the acid ph3 conditions, Bath Salts are in a fully ionized form, thus greatly increasing the ability to ion-exchange with the mixed mode surface of the Bio-SPME fiber. At this ph the Bath Salts are also much more hydrophilic and have a higher tendency not to partition with a purely hydrophobic surface. The acid functionality of the mixed mode surface also acts to decrease the surface barrier of the alkyl C18 chain, thus making it a more accessible surface for the hydrophilic Bath Salts. Extraction time of 15 minutes demonstrated reproducible recovery results, while being pre-equilibrium condition. A second study was performed on the extraction of the Bath Salts from plasma samples. For this portion of the study, both analyte extraction along with matrix monitoring was conducted for the plasma samples. Table 3 details the Bio-SPME plasma extraction conditions. 13

Table 3. Bio-SPME Plasma Extraction Conditions Plasma ph3 Rat plasma ph adjusted with phosphoric acid, spiked to 50 ng/ml bath salts Plasma ph7 Rat plasma ph adjusted with 1 M sodium phosphate buffer ph 7 (10 mm final), spiked to 50 ng/ml bath salts Extraction: 15 min. from 96-well plates 1 ml volume, 750 µl of sample per well Desorption: 60 min. in 150 µl methanol with 0.5% NH 4 H (28% solution) in 300 µl volume 96-well plate Drying step: 60 min. at 40 C under a blanket of nitrogen 14

Figure 5. Plasma Extraction ph Effect 45.0 40.0 plasma ph 3 plasma ph 7 35.0 30.0 25.0 20.0 15.0 10.0 5.0 0.0 MDPV buphederone 3-FMC butylone ethylone 4-FMC mephedrone methylone methedrone 15

Figure 5 depicts the extraction efficiency of Bath Salts from the ph adjusted plasma samples. As anticipated, sample matrices can impact the extraction efficiency of the analytes. Plasma adjusted to ph 3 demonstrated similar extraction efficiencies to ph 3 buffer conditions. The plasma ph 7 extraction efficiencies were notably lower than from the ph 7 buffer conditions. Additional experiments confirmed protein binding effects of the bath salts in the plasma sample were the cause for the lower extraction efficiencies at ph 7. At ph 3 conditions, the low ph disrupted the protein binding effect of the Bath Salts, thus enhancing the extraction efficiencies on the Bio-SPME fiber. A separate protein precipitation technique was performed on plasma samples for comparison of analyte response and matrix monitoring. Protein precipitation was conducted using 3:1 ratio of 1% formic acid acetonitrile to plasma, this centrifuged solution was then analyzed directly. Figures 6 and 7 depict the comparison of analyte response and extracted matrix between the Bio-SPME technique and protein precipitation. 16

Figure 6. Analyte Response: Sample Prep Technique Bio-SPME Mixed Mode ph 3.0 2X increase in response as compared to protein precipitation In both samples, plasma spiked at 50 ng/ml of bath salts Protein Precipitated Plasma 17 17

Figure 7. Phospholipid Matrix: Sample Prep Technique Bio-SPME Mixed Mode ph 3.0 1/10 th phospholipids as compared to PPT Protein Precipitated Plasma Ascentis Express C18, 5 cm x 2.1 mm, 5 mm ammonium formate (95:5 methanol:water) 0.3 ml/min., 55 C 18

Conclusions The Bio-SPME extraction studies demonstrated the capability of analyzing sub 10 ng/ml concentration levels of Bath Salts in plasma samples. The mixed-mode chemistry of the Bio-SPME enable unique selectivity for enrichment of the polar basic compounds as the Bath Salts. Plasma samples prepared using the Bio-SPME technique had 10X reduction in detected phospholipid matrix as compared to standard precipitation techniques, while demonstrating increased analyte response. The Bio-SPME Tippet device enables a unique approach for micro extraction and concentration of analytes from biological matrices, requiring minimal sample volumes. As with other sample prep techniques, parameters such as sample ph and matrix can have an impact on extraction efficiencies. 19

Conclusions (contd.) The binding process used to embed the functionalized media facilitates a shielding affect to prevent binding of proteins and higher molecular endogenous matrix. By doing so, this sampling technique enables the differentiation of free form analytes in the sample form protein bound analytes. This approach demonstrates the ability for quantitative analyte enrichment from limited sample volumes. These tippets can be configured for singular or multi tippet processing, greatly increasing the capability for high throughput applications. 20