Dynamic behavior of turbine foundation considering full interaction among facility, structure and soil

Similar documents
Influence of the Soil Structure Interaction on the Fundamental Period of Large Dynamic Machine Foundation

NON-LINEAR ANALYSIS OF SOIL-PILE-STRUCTURE INTERACTION UNDER SEISMIC LOADS

EXAMPLE OF PILED FOUNDATIONS

NONLINEAR CHARACTERISTICS OF THE PILE-SOIL SYSTEM UNDER VERTICAL VIBRATION

SEISMIC RESPONSE OF INDUSTRIAL STRUCTURES CONSIDERING SOIL-PILE-STRUCTURE INTERACTION

INELASTIC RESPONSES OF LONG BRIDGES TO ASYNCHRONOUS SEISMIC INPUTS

DYNAMIC ANALYSIS OF PILES IN SAND BASED ON SOIL-PILE INTERACTION

Frequency response analysis of soil-structure interaction for concrete gravity dams

Soil-Structure Interaction in Nonlinear Pushover Analysis of Frame RC Structures: Nonhomogeneous Soil Condition

Centrifuge Shaking Table Tests and FEM Analyses of RC Pile Foundation and Underground Structure

Codal Provisions IS 1893 (Part 1) 2002

Dynamic Analysis of Pile Foundations: Effects of Material Nonlinearity of Soil

Embedded Foundation with Different Parameters under Dynamic Excitations

3-D FINITE ELEMENT NONLINEAR DYNAMIC ANALYSIS FOR SOIL-PILE-STRUCTURE INTERACTION

Study of the influence of the resonance changer on the longitudinal vibration of marine propulsion shafting system

ON THE PREDICTION OF EXPERIMENTAL RESULTS FROM TWO PILE TESTS UNDER FORCED VIBRATIONS

Model tests and FE-modelling of dynamic soil-structure interaction

Design Procedures For Dynamically Loaded Foundations

The Analysis of Seismic Response for Base-isolated Structure by LS-DYNA

NONLINEAR SEISMIC SOIL-STRUCTURE (SSI) ANALYSIS USING AN EFFICIENT COMPLEX FREQUENCY APPROACH

on the figure. Someone has suggested that, in terms of the degrees of freedom x1 and M. Note that if you think the given 1.2

Numerical Modeling of Interface Between Soil and Pile to Account for Loss of Contact during Seismic Excitation

SPECIAL DYNAMIC SOIL- STRUCTURE ANALYSIS PROCEDURES DEMONSTATED FOR TWO TOWER-LIKE STRUCTURES

Combined Effect of Soil Structure Interaction and Infill Wall Stiffness on Building_- A Review

Nonlinear Soil - Pile - Structure Interaction in Dynamic or Seismic Response

Nonlinear Rolling Element Bearings in MADYN 2000 Version 4.3

Geotechnical Modeling Issues

Structural Dynamics Lecture Eleven: Dynamic Response of MDOF Systems: (Chapter 11) By: H. Ahmadian

Introduction to structural dynamics

Dynamic Soil Structure Interaction

This equation of motion may be solved either by differential equation method or by graphical method as discussed below:

Seismic Analyses of Concrete Gravity Dam with 3D Full Dam Model

Effect of Soil-Foundation Interaction on the Dynamic Response of a Four-Cylinder Compressor Foundation

Modal Analysis: What it is and is not Gerrit Visser

SHAKE TABLE STUDY OF SOIL STRUCTURE INTERACTION EFFECTS ON SEISMIC RESPONSE OF SINGLE AND ADJACENT BUILDINGS

DYNAMIC RESPONSE OF EARTHQUAKE EXCITED INELASTIC PRIMARY- SECONDARY SYSTEMS

Chapter a. Spring constant, k : The change in the force per unit length change of the spring. b. Coefficient of subgrade reaction, k:

Evaluation of short piles bearing capacity subjected to lateral loading in sandy soil

Numerical Modelling of Dynamic Earth Force Transmission to Underground Structures

Lecture 9: Harmonic Loads (Con t)

SOIL-STRUCTURE INTERACTION, WAVE PASSAGE EFFECTS AND ASSYMETRY IN NONLINEAR SOIL RESPONSE

Comparison of Base Shear Force Method in the Seismic Design Codes of China, America and Europe

Study on elevated light rail induced vibration attenuation along the surrounding ground

INFLUENCE OF SOIL NONLINEARITY AND LIQUEFACTION ON DYNAMIC RESPONSE OF PILE GROUPS

Preliminary Examination - Dynamics

Dynamics of structures

Characterizing Pile Foundations for Evaluation of Performance Based Seismic Design of Critical Lifeline Structures. W. D.

PLEASURE VESSEL VIBRATION AND NOISE FINITE ELEMENT ANALYSIS

SEISMIC BASE ISOLATION

Pseudo-dynamic tests in centrifugal field for structure-foundation-soil systems

Interpretation of Pile Integrity Test (PIT) Results

Numerical simulation of inclined piles in liquefiable soils

ABSTRACT. Ossama Salem Ali Ahmed, Ph.D., interaction of the pile with the surrounding soils under vibratory loading will modify

Nonlinear pushover analysis for pile foundations

Seismic design of bridges

VIBRATION ANALYSIS OF TIE-ROD/TIE-BOLT ROTORS USING FEM

Analysis on propulsion shafting coupled torsional-longitudinal vibration under different applied loads

Multi Linear Elastic and Plastic Link in SAP2000

Sabah Shawkat Cabinet of Structural Engineering Walls carrying vertical loads should be designed as columns. Basically walls are designed in

TABLE OF CONTENTS SECTION TITLE PAGE 2 PRINCIPLES OF SEISMIC ISOLATION OF BRIDGES 3

KINEMATIC RESPONSE OF GROUPS WITH INCLINED PILES

Harmonized European standards for construction in Egypt

2D Liquefaction Analysis for Bridge Abutment

BENCHMARK LINEAR FINITE ELEMENT ANALYSIS OF LATERALLY LOADED SINGLE PILE USING OPENSEES & COMPARISON WITH ANALYTICAL SOLUTION

REPRODUCTION OF A LARGE-SCALE 1G TEST ON UNSATURATED SAND DEPOSITS AND PILE FOUNDATIONS USING CENTRIFUGE MODELING

Soil Dynamics Prof. Deepankar Choudhury Department of Civil Engineering Indian Institute of Technology, Bombay

Effects of Damping Ratio of Restoring force Device on Response of a Structure Resting on Sliding Supports with Restoring Force Device

DYNAMIC RESPONSE OF INELASTIC BUILDING- FOUNDATION SYSTEMS

DYNAMIC PROPERTIES OF STRUCTURE-PILE SYSTEM USING MOCK-UP MODEL

Shake Table Study of Soil Structure Interaction Effects in Surface and Embedded Foundations

INFLUENCE OF THE SOIL-STRUCTURE INTERACTION ON THE SEISMIC BEHAVIOR OF BUILDINGS ON SHALLOW FOUNDATIONS

Dynamics of Machinery

Dr.Vinod Hosur, Professor, Civil Engg.Dept., Gogte Institute of Technology, Belgaum

Chapter 23: Principles of Passive Vibration Control: Design of absorber

2040. Damage modeling and simulation of vibrating pipe with part-through circumferential crack

Dynamic analysis of a reinforced concrete shear wall with strain rate effect. Synopsis. Introduction

ROTATING RING. Volume of small element = Rdθbt if weight density of ring = ρ weight of small element = ρrbtdθ. Figure 1 Rotating ring

Dynamic Analysis Contents - 1

Dynamic Analysis of An 1150 MW Turbine Generator

Cork Institute of Technology. Summer 2007 Mechanics of Machines (Time: 3 Hours)

BI-DIRECTIONAL SEISMIC ANALYSIS AND DESIGN OF BRIDGE STEEL TRUSS PIERS ALLOWING A CONTROLLED ROCKING RESPONSE

Q. 1 Q. 5 carry one mark each.

D : SOLID MECHANICS. Q. 1 Q. 9 carry one mark each.

Structural Dynamics Lecture 4. Outline of Lecture 4. Multi-Degree-of-Freedom Systems. Formulation of Equations of Motions. Undamped Eigenvibrations.

Preliminary Examination in Dynamics

SHAKING TABLE TEST OF STEEL FRAME STRUCTURES SUBJECTED TO NEAR-FAULT GROUND MOTIONS


TRANSPORTATION RESEARCH BOARD. TRB Webinar Program Direct Displacement Based Seismic Design of Bridges. Thursday, June 22, :00-3:30 PM ET

SEISMIC RESPONSE EVALUATION OF AN RC BEARING WALL BY DISPLACEMENT-BASED APPROACH

COEFFICIENT OF DYNAMIC HORIZONTAL SUBGRADE REACTION OF PILE FOUNDATIONS ON PROBLEMATIC GROUND IN HOKKAIDO Hirofumi Fukushima 1

COMPARATIVE STUDY OF LINEAR-ELASTIC AND NONLINEAR- INELASTIC SEISMIC RESPONSES OF FLUID-TANK SYSTEMS

RESPONSE ANALYSIS STUDY OF A BASE-ISOLATED BUILDING BASED

PILE FOUNDATION RESPONSE DUE TO SOIL LATERAL SPREADING DURING HYOGO-KEN NANBU EARTHQUAKE

Verification of a Micropile Foundation

EFFECT OF SEISMIC WAVE INCLINATION ON STRUCTURAL RESPONSE

Effective stress analysis of pile foundations in liquefiable soil

KINETIC EEFCT ON FLEXIBLE BODIES BEHAVIOR

Program System for Machine Dynamics. Abstract. Version 5.0 November 2017

DYNAMIC CHARACTERISTICS OF PILE GROUPS UNDER VERTICAL VIBRATIONS

FINITE GRID SOLUTION FOR NON-RECTANGULAR PLATES

Transcription:

Dynamic behavior of turbine foundation considering full interaction among facility, structure and soil Fang Ming Scholl of Civil Engineering, Harbin Institute of Technology, China Wang Tao Institute of Engineering Mechanics, China Earthquake Administration, China Li Hui Scholl of Civil Engineering, Harbin Institute of Technology, China SUMMARY In this paper a comprehensive investigation on the dynamic characteristics of turbine-foundation-soil system is performed. To consider the soil effect and facility vibration, a sophisticated finite element model was constructed. All the major components of the system, including shaft, rotors, journal bearings, deck, piers, foundation mat, piles, and soil medium, have been included. Full interaction between the facility, the foundation, and the soil medium, is considered. A 1MW turbine-foundation-soil system is analyzed under excitations from rotor unbalances and earthquakes. The influence of soil-structure interaction (SSI) on the response of the system is explored by using three-dimensional viscous-spring boundary elements. It is found that the effect of SSI strongly influences the displacements and internal forces of the system under rotor unbalance excitation. Under seismic excitation, however, although the presence of soil does affect the displacements of the system, the effect on the acceleration and internal force is minimal. Keyword: turbine-foundation-soil system, soil-structure interaction, dynamic behavior 1. INTRODUCTION A turbine-generator set and its foundation constitute a rather complicated system, which consists of shaft, rotors, journal bearings, deck, piers, mat, piles and the underlying soil medium, as illustrated in Figure 1. The deck and the piers, on which the turbine-generator set is anchored, are usually designed in steel, reinforced concrete, or prestressed concrete. The deck carries the machinery on the top and provides enough space below to install the auxiliary equipment such as condensers and pipes. The spatial frame configuration of the deck and piers is commonly referred to as the turbine-generator pedestal. The dynamic behavior and seismic response of such a system is determined by the interaction of all the components. The foundation not only should have a sufficient bearing capacity to support the turbine machine and its auxiliary equipment, but also be designed to limit the vibration amplitudes of the shaft, the rotors, and the bearings within the acceptable level. Excessive vibration amplitudes and deflections may cause serious damage if rotor blades hit the casing. Early analyses of turbine-foundation systems were conducted based on very simplified models such as lumped mass systems. With the development of the finite element method, three-dimensional elements were introduced to model the deck and piers. The influence of the soil-structure interaction, if ever considered, was estimated crudely by introducing spring and dashpot coefficients of the elastic half-space solution. For years afterward, scientists put forward artificial boundaries, such as viscous-spring boundaries, to solve the problem caused by reflection at the edges of soil computational domain and successfully employed this method in 2D and 3D numerical simulation. In this paper, a numerical model of the complete turbine-foundation-soil system is established using three-dimensional solid elements. All the major components of the system, including the rotors, shaft, bearings, the deck, the columns, the foundation mat, the optional piles, and the soil medium, are incorporated. The turbine-generator, the foundation superstructure and the soil medium are modeled

by finite elements. The underlying soil is a layered medium with viscous-spring boundaries at edges of the computational domain. Seismic excitation is introduced by the inversion from free ground motion to soil medium boundaries. The response of a typical 1MW turbine-generator-foundation system subjected to rotor unbalance and seismic load is presented. The influence of soil-structure interaction, which has been conducted roughly in previous studies, is investigated. Turbine HP IP LP Generator Shaft Bearings Decks Condensers Piers Soil Optional piles Figure 1. A schematic view of a 1MW turbine-generator-foundation system 2. THE NUMERICAL MODEL FOR TURBINE-FOUNDATION-SOIL SYSTEMS The facility, including shaft, rotors and journal bearings, is considered as rigid body, which has no material definition and is anchored on the deck with rigid connection. The underlying soil is modeled as layered medium, which is surrounded by viscous-spring artificial boundaries. The whole model of the system is illustrated as Figure 2. The turbine has three stages, i.e. HP, IP and LP, with an operating speed of 3n/s. The rotors are idealized as several rigid disks attached to the shaft, which is supported on six groups of journal bearings. The operating deck and the twelve columns form a spatial frame structure. Both the deck and the mat are rather thick concrete plates. The piles are modeled as three-dimensional solid elements and embedded in the soil medium. (a) and piles

(b) With piles only Figure 2. (c) With piles and soil A schematic view of the 3D finite element model 2.1. The Turbine-Generator System The turbine-generator system consists of the shaft, the rotors and the journal bearings. The numerical discretization of shaft-rotor is shown in Figure 3. The shaft, which has the same diameters at each turbine-generator stage, is represented by rigid elements with circular cross-sections. The rotors within several turbine stages and generator are simulated as rigid disks attached along the shaft. The HP rotor is represented as two disks with 12tone mass each. The IP rotor is represented as two disks with masses of 15.5tone each. The LP rotor is represented as four 2tone disks and four 19tone disks. The generator rotor is represented as a long stick with mass of 1tone. Figure 3. Numerical discretization of the shaft-rotor of a 1MW turbine-generator set 2.2. The Foundation Superstructure The turbine machine and the generator are anchored on an operating deck, which is supported by piers. This spatial frame structure, as shown in Figure 2(a) and Figure 4, allows space under the turbine to install other auxiliary facilities such as condensers and piping. The operating deck is made from reinforced concrete with the material parameters listed in table 1. The columns are 18.8m high with the same material as the deck and rectangular cross-section (2.5m 2.5m) on the average. The geometrical dimensions of the mat (with a thickness of 4m) can be shown in Figure 4. The material of the mat is same as that of the deck and columns. Table 2.1 Material Parameters of The Deck Material Young s modulus Poisson s ratio Mass density Damping ratio Concrete 32.5gpa.2 255kg/m 3.5 Rebar 2gpa.3 785kg/m 3.5

Figure 4. Plan view of the operating deck, columns and the foundation mat (unit:m) 2.3. The Underlying Soil Medium The underlying soil, which is embedded by 48 piles, is modeled as a three-dimensional medium, as shown in Figure 5. The geometrical size of the soil is 1m 1m 5m and the soil is surrounded by viscous-spring artificial boundaries. The material parameters of the layered soil and boundaries are listed in the Table 2 and Table 3. The plies are also made of reinforced concrete and provided with the same material as deck and columns. (a) soil medium (b)artificial boundaries (c)piles Figure 5. Isometric view of the soil medium and piles Table 2 Material Parameters of The Layered Medium Layer Description Thickness Young s modulus Poisson s ratio Mass density 1 Clay 6m 197mpa.3 193kg/m 3 2 Sand 6m 312mpa.3 192kg/m 3 3 Transition 1m 638mpa.35 194kg/m 3 4 Residual1 1m 1283mpa.35 19kg/m 3 5 Residual2 1m 1872mpa.3 2kg/m 3 6 Weathered rock 8m 3362mpa.3 22kg/m 3 Table 3 Material Parameters of The Artificial Boundaries Position Young s modulus Mass density Stiffness coefficient Side 1 6.17mpa 1kg/m 3.37 Side 2 9.13mpa 1kg/m 3.3 Side 3 17.99mpa 1kg/m 3.23 Side 4 33.62mpa 1kg/m 3.17 Side 5 46.53mpa 1kg/m 3.15 Side 6 76.51mpa 1kg/m 3.12 Bottom 86.13mpa 1kg/m 3.11 2.4. The Viscous-Spring Artificial Boundary The purpose of the viscous-spring artificial boundary is to eliminate the reflected wave that occurs at the boundary surface of the soil computational domain by simulating the impact from outside infinite

medium to inner area. If the effects of forces between the outside medium and inner domain can be described rationally and precisely by a certain system, the energy transmits from the structure to infinite soil may go though the artificial boundaries without reflection. Such a system always contains components of stiffness, damping and mass, as shown in Figure 6 (a). However, the viscous-spring-mass system is not stable because the damping part and the mass part are in series connection. To guarantee the robustness of the system, the mass cell is removed and left with only stiffness and damping parts, as shown in Figure 6 (b). The parameters of such a system were deduced by Liu Jingbo and he finally proved the accuracy of this method in three-dimensional simulation. The values of the stiffness and damping in this system can be got by following parameters: 4G 2G Normal direction: K, C cp ; Tangential direction: K, C cs R R G is the shear modulus of soil medium is the mass density of soil medium R is the nearest distance between the structure base and the boundary surface c and c is the wave velocity of P wave and S wave. p s Artificial boundary Node on the boundary Y Y X X K C Z M (a)physical system imposed on boundary (b)three-dimensional viscous-spring boundary Figure 6. Physical component applied on the normal boundary However, it causes extreme inconvenience for preprocessor of the numerical simulation to add spring-damping systems to boundary nodes one by one. So an advanced method, i.e. consistent viscous-spring artificial boundary, is raised to reduce the amount of work before numerical analysis and this technology has ample precision to achieve three-dimensional simulation. The consistent viscous-spring artificial boundary employs the boundary elements instead of the damping-spring systems to realize the effects of forces between the outside soil and inner domain, as shown in Figure 5 (b). The viscous-spring elements can produce the equal matrices of stiffness and damping as the damping-spring systems. The special boundary elements, which should be the same types with that of the inner computational domain, are defined by the following parameters: Young s modulus ~ G (1 ~)(1 2~) R c E N h ; Stiffness coefficient s cp ~ R (1 ~) 2 3G T N Mass density ~ usually equals a relative low value, such as one-tenth of the medium density. G is the shear modulus of soil medium is the mass density of soil medium R is the nearest distance between the structure base and the boundary surface h is the thickness of the elements c and c are the wave velocity of P wave and S wave. p s N and T are the correction factors; N values from 1 to 2 and T values from.5 to 1. The parameters of the artificial boundary are listed in Table 3.

3. MODAL ANALYSIS FOR THE FOUNDATION SYSTEMS The natural frequencies of both the model (fixed-base) and model (flexible-base) are obtained using classic modal analysis. Table 4 shows the first 8 natural frequencies of the systems. Table 4 Natural Frequencies of The Foundation Systems (Hz) number Model Model and piles 1 2.17 1.76 2 2.59 1.85 3 2.65 2.8 4 7.94 6.4 5 8.93 6.59 6 13.27 6.81 7 14.49 7.62 8 14.92 7.68 The soil-structure interaction provides the rotational freedom of the foundation mat and reduces the natural frequencies of the superstructure. The first order mode shape of the fixed-base system is translation at x direction (the direction along the shaft) with frequency 2.17Hz and the first order mode of flexible-base system has the same shape with frequency 1.76Hz, which is lower than 2.17, because the soil-structure interaction provides freedom of rotation at z direction (the horizontal direction normal to x direction). The soil-structure interaction provides the rotational freedom of the foundation and decrease the bending stiffness of the mat. That is the reason why when the soil medium is considered the frequencies of the system may be lower. 4. DYNAMIC RESPONSE DUE TO ROTOR UNBANLANCE The rotor unbalance excitation is defined by an eccentricity e=.5mm. The applied load is therefore 2 P mi e for the ith disk, in which is the circular frequency, mi is the mass of the ith disk. The rated rotor speed of operation is 3n/min, i.e. 5Hz, which is employed in the dynamic analysis of this section due to rotor unbalance. These loads are applied at each disk and the rotor unbalance load is intended for investigation of the soil-structure interaction only. The turbine-generator-foundation system is studied under vertical and horizontal rotor unbalance excitation. Two different cases, i.e. fixed-base system and flexible-base system, are considered to explore the effect of soil-structure interaction. The rotor speed increases linearly from Hz to 5Hz within 1 seconds and both the displacements of the journal bearings and the internal forces of the columns are given. 4.1. Vertical Excitation The time history responses of the system due to vertical rotor unbalance excitation, including the vertical displacements of several typical bearings, i.e. the bearings labeled from No.4 to No.6 that are close to the LP and GE parts of the turbine-generator system, and the internal forces in the LP-GE column, are shown in Figure 7. The operating frequency of the rotor increases linearly from Hz to 5Hz within 1 seconds, which implies that the time history responses can be interpreted as the frequency results to some extent. Figure 7 (a) to (c) shows the vertical displacement amplitude vs. time at three bearing locations. It can be observed that the interaction between soil and structure reduces the maximum vibration amplitudes of the picked bearings. For example, the vibration amplitude of the bearing No. 6 decreases from.32 to.14mm, which is a 56 percent reduction when the soil-structure interaction is considered. This reduction of vibration amplitudes results from the fact that the radiation damping introduced by the soil may alleviate the dynamic response of the structure. At lower frequencies, however, vibration

Displacement (mm) Axial Force P (kn) Displacement (mm) Displacement (mm) amplitudes may increase due to the SSI effect. For instance, the amplitudes of bearing No. 3 and No. 4 become higher at f =5Hz. The effect of soil-structure interaction diminishes as the frequency increases further to the turbine operating speed. The axial force of picked column is shown in Figure 7 (d). Generally speaking, the amplitude of axial force is influenced by the soil obviously and the values of force increase at higher frequencies when the soil-structure is taken into account..4.2 Bearing No.4.4.2 Bearing No.5 -.2 -.2 -.4 2 4 6 8 1 (a) -.4 2 4 6 8 1 (b).4.2 Bearing No.6 6 4 2 Internal Force of LP-GE Column -.2-2 -4 -.4 2 4 6 8 1 (c) -6 2 4 6 8 1 (d) Figure 7. Vertical displacements at bearing locations and axial force of the LP-GE column 4.2. Horizontal Excitation The time history responses of the system due to horizontal rotor unbalance excitation, including the horizontal displacements of some typical bearings, i.e. the bearings labeled from No.4 to No.6 and the internal forces at the top of LP-GE column, are shown in Figure 8. Figure 8 (a) to (c) shows the horizontal displacement amplitude vs. time at three bearing locations. It can be found that the interaction between soil and structure reduces the vibration amplitudes of the picked bearings at about all frequencies. For example, the maximum vibration amplitude of the bearing No. 5 decreases from.65 to.44 mm, which is a 32 percent reduction when the interaction of soil-structure is considered. The vibration amplitudes decrease as a result of the fact that the radiation damping introduced by the soil may consume the system s energy and weaken the dynamic responses of the structure.

Displacement (mm) Shear Force V (kn) Displacement (mm) Displacement (mm).1.5 Bearing No.4.1.5 Bearing No.5 -.5 -.5 -.1 2 4 6 8 1 (a) -.1 2 4 6 8 1 (b).1.5 Bearing No.6 4 2 Internal Force of LP-GE Column -.5-2 -.1 2 4 6 8 1 (c) -4 2 4 6 8 1 (d) Figure 8. Horizontal displacements at bearing locations and shear force of the LP-GE column The shear force of picked column is shown in Figure 8 (d). The amplitudes of shear force are influenced by the soil severely and the values of force increase at several certain frequencies such as 11Hz and 21Hz when the soil-structure is taken into account. For example, the amplitude of the shear force increases from 128 to 376 kn when the frequency is about 35Hz. Generally speaking, the displacement amplitudes due to horizontal rotor unbalance excitation are much lower than those due to vertical rotor excitation, except for very low frequencies. This can be explained by the fact that very strong columns and foundation mat are employed, resulting in high bending stiffness in the horizontal direction. The relatively soft soil medium also contributes to larger vertical displacements. 5. DYNAMIC RESPONSE DUE TO SEISMIC EXCITATION The seismic excitation is defined by the free-field ground acceleration in the time domain. The time history of Elcentro is picked and the acceleration peak is.32g. Figure 9 shows the time history and response spectra of the input ground motion. The uniform ground motion is applied in the transverse direction (perpendicular to the shaft). The models with or without the soil are considered here to incorporate the full soil-structure interaction and the dynamic responses of the journal bearings, such as relative displacement and absolute acceleration at horizontal direction, the base shear of foundation and the internal force of LP-GE column are given.

Acceleration (g) Displacement (mm) Spectral Acceleration (g) ( () Acceleration (mm/s 2 ).4 Elcentro 1 Response Spectra.2 -.2 -.4 1 2 3.8.6.4.2 1 2 3 4 5 Figure 9. The time history and response spectra of the Elcentro Figure 1 (a) shows the average displacement of six bearings vs. time at horizontal direction. Apparently, the effect of the soil-structure interaction amplifies the dynamic response through all the seismic excitation time. Concretely, the peak displacement decreases from 19.5 to 51.3mm, which is a 158 percent increase when the SSI effect is considered. This can be explained by that the existence of soil provides the rotation freedom of foundation mat and decreases the bending stiffness of the mat. Therefore it is reasonable for the foundation to deform larger at the horizontal direction when the interaction of soil and structure is taken into account. Figure 1 (b) shows the time history of the absolute acceleration of bearings. It is observed that the amplitude of the acceleration is influenced by the soil-structure interaction slightly. For instance, the peak acceleration at horizontal direction increases from 4969 to 5266mm/s 2, which is a 6 percent enhancement when the soil medium is employed. Relative Displacement of Journal Bearings 6 4 2 Absolute Acceleration of Journal Bearings 6 4 2-2 -2-4 -4-6 1 2 3 (a) -6 1 2 3 (b) Figure 1. Dynamic response of the journal bearings Figure 11 (a) shows the base shear amplitude of the foundation mat vs. time at the transverse direction (perpendicular to the shaft). The effect of the SSI play a role in the change of the base shear amplitude, since the peak value decreases from 713 to 632kN, which is a 13 percent reduction. Figure 11 (b) shows the shear force of the LP-GE column vs. time at transverse direction. It is observed that the amplitude of shear force is influenced by the soil-structure interaction apparently. For instance, the peak value of force decreases from 344 to 2682kN, which is a 22 percent reduction when SSI effect is considered.

Base Shear (kn) Shear Force (kn).5 1 x 15 Base Shear of Foundation 4 2 Shear Force in the LP-GE Column -.5-2 -1 1 2 3 (a) -4 1 2 3 (b) Figure 11. Base shear of the foundation mat and shear force in the LP-GE column 6. CONCLUSIONS The main findings in this paper are summarized in the following. Under vertical rotor unbalance excitation, the soil-structure interaction reduces the peak vibration amplitudes of all bearings significantly due to the energy consumption of the soil medium. However, the vibration may increase in the low-frequency range. The axial force is sensitive to the soil-structure interaction only at higher frequencies. Under horizontal rotor unbalance excitation, the effect of SSI decreases the vibration amplitudes of bearings and increases the internal force in the column. Since the turbine-generator set and the foundation superstructure are relatively rigid compared to the soil medium, the system behaves like a rigid body under seismic excitation. Although the influence of the soil-structure interaction on the relative horizontal displacement of the system is quite significant, it has small impact on the absolute acceleration and the base shear of mat. It should be noted that the dynamic response of the foundation and internal force in the columns are apparently higher than those under rotor unbalance excitation. ACKNOWLEDGEMENT This project was supported by Northwest Electric Power Design Institute of China Power Engineering Consulting Group and the key project Lifetime research of thermal power plant based on the structural type and structure-equipment interaction supported by School Of Civil Engineering, Harbin Institute Of Technology. Any opinion, findings, and conclusion or recommendation expressed in this paper are those of the authors and do not necessarily reflect the views of the sponsors. REFERENCES Weiming Liu and Milos Novak. (1995). Dynamic behaviour of turbine-generator-foundation systems. Earquake Engineering And Structural Dynamics. 24, 339-36. Eduardo Kausel. (21). Early history of soil-structure interaction. Soil Dynamics And Earthquake Enginneering. 3, 822-832. Liu Jingbo, Wang zhenyu, Du Xiuli and Du Yixin. (25). Three-dimensional visco-elastic artificial boundaries in time domain for wave motion problems. Engineering Mechanics. 22:6, 46-51. Liu Jingbo, Gu Yin, and Du Yixin. (26). Consistent viscous-spring artificial boundaries and viscos-spring boundary elements. Chinese Journal Of Geotechnical Engineering. 28:9, 17-175. Liu Jingbo, and Lu Yandong. (1997). A direct method for analysis of dynamic soil-structure interaction based on interface idea. Dynamic Soil-Structure Interaction Academic Press, 258-273.