Low-coherence heterodyne photon correlation spectroscopy

Similar documents
Imaging through random media using low-coherence optical heterodyning

How DLS Works: Interference of Light

Introduction to Dynamic Light Scattering with Applications. Onofrio Annunziata Department of Chemistry Texas Christian University Fort Worth, TX, USA

Supplementary Figures

Spatial coherence of forward-scattered light in a turbid medium

Dual-beam incoherent cross-correlation spectroscopy

Measurement of liquid surface properties by laser-induced surface deformation spectroscopy

Quantification of optical Doppler broadening and optical path lengths of multiply scattered light by phase modulated low coherence interferometry

Digital Holographic Measurement of Nanometric Optical Excitation on Soft Matter by Optical Pressure and Photothermal Interactions

Where are the Fringes? (in a real system) Div. of Amplitude - Wedged Plates. Fringe Localisation Double Slit. Fringe Localisation Grating

6. Laser Doppler Anemometry. Introduction to principles and applications

Particles, drops, and bubbles. Lecture 3

Physical Characterization of Solid-Liquid Slurries at High Weight Fractions Using Optical and Ultrasonic Methods Grant # /28/02

Lecture 20. Wind Lidar (2) Vector Wind Determination

Measuring particle aggregation rates by light scattering

DEVELOPMENT OF NANO PARTICLE SIZING SYSTEM USING FLUORESCENCE POLARIZATION

requency generation spectroscopy Rahul N

PLUS. Zeta/Nano Particle Analyzer

Part 8. Special Topic: Light Scattering

Coherent X-ray Scattering and X-ray Photon Correlation Spectroscopy

Diffusing-wave spectroscopy: dynamic light scattering in the multiple scattering limit

LASER APPLICATIONS XII. QPR No Academic Research Staff. Ezekiel. Prof. S. Graduate Students

An Overview of Advanced LIGO Interferometry

Let us consider a typical Michelson interferometer, where a broadband source is used for illumination (Fig. 1a).

Internal magnetic field measurement in tokamak plasmas using a Zeeman polarimeter

Comments to Atkins: Physical chemistry, 7th edition.

Lecture 5: Polarization. Polarized Light in the Universe. Descriptions of Polarized Light. Polarizers. Retarders. Outline

Molecular spectroscopy

DIGITAL CORRELATION OF FIRST ORDER SPACE TIME IN A FLUCTUATING MEDIUM

Long Path Industrial OCT High-precision Measurement and Refractive Index Estimation

The Scattering of Light by Small Particles. Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin 53706

Absorption length for photon propagation in highly dense colloidal dispersions

ANALYSIS OF LOW DENSITY PARTICLES USING DIFFERENTIAL CENTRIFUGAL SEDIMENTATION

CHAPTER 6 INTRODUCTION TO SPECTROPHOTOMETRIC METHODS Interaction of Radiation With Matter

CHAPTER 6 INTRODUCTION TO SPECTROPHOTOMETRIC METHODS Interaction of Radiation With Matter

UvA-DARE (Digital Academic Repository)

Lecture 26. Wind Lidar (4) Direct Detection Doppler Lidar

Optical time-domain differentiation based on intensive differential group delay

Introduction to Dynamic Light Scattering for Particle Size Determination

Introduction to Differential Sedimentation

What is the value of multi-angle DLS?

New Plasma Diagnosis by Coherence Length Spectroscopy

Experimental Colloids I (and I)

Metrology and Sensing

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

MODERN INTERFEROMETRY

Realisation of Transparency below the One-Photon Absorption Level for a Coupling Laser Driving a Lambda System under EIT Conditions

DIODE LASER SPECTROSCOPY

10. OPTICAL COHERENCE TOMOGRAPHY

gives rise to multitude of four-wave-mixing phenomena which are of great

Optical Tweezers. BGGN 266, Biophysics Lab. June, Trygve Bakken & Adam Koerner

Probing creep motion in granular materials with light scattering

American Institute of Physics 319

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

The Scattering of Light by Small Particles. Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin 53706

Constructive vs. destructive interference; Coherent vs. incoherent interference

Lasers and Electro-optics

Kolligative Eigenschaften der Makromolekülen

Aging in laponite water suspensions. P. K. Bhattacharyya Institute for Soldier Nanotechnologies Massachusetts Institute of Technology

Complex refractive-index measurement based on Fresnel s equations and the uses of heterodyne interferometry

CPS Instruments Europe P.O. Box 180, NL-4900 AD Oosterhout, The Netherlands T: +31 (0) F: +31 (0) E:

Two-electron systems

Interferometric. Gravitational Wav. Detectors. \p World Scientific. Fundamentals of. Peter R. Sawlson. Syracuse University, USA.

Performance Limits of Delay Lines Based on "Slow" Light. Robert W. Boyd

Multiple Light Scattering from Disordered Media. The Effect of Brownian Motion of Scatterers*

Richard Miles and Arthur Dogariu. Mechanical and Aerospace Engineering Princeton University, Princeton, NJ 08540, USA

Dispersion and how to control it

Particle Size Determinations: Dynamic Light Scattering: page 161 text

A Guide to Experiments in Quantum Optics

CHEM*3440. Photon Energy Units. Spectrum of Electromagnetic Radiation. Chemical Instrumentation. Spectroscopic Experimental Concept.

Time-resolved Diffusing Wave Spectroscopy to Enable Ultrafast Electro-optic Relaxation Dynamic in Liquid Crystals

Parametric down-conversion

Solution structure and dynamics of biopolymers

Lecture 19 Optical MEMS (1)

Supporting Information: Ultrafast Excited State Transport and Decay Dynamics in Cesium Lead Mixed-Halide Perovskites

Self-Phase Modulation in Optical Fiber Communications: Good or Bad?

2.71. Final examination. 3 hours (9am 12 noon) Total pages: 7 (seven) PLEASE DO NOT TURN OVER UNTIL EXAM STARTS PLEASE RETURN THIS BOOKLET

HYPER-RAYLEIGH SCATTERING AND SURFACE-ENHANCED RAMAN SCATTERING STUDIES OF PLATINUM NANOPARTICLE SUSPENSIONS

Measurements of photon scattering lengths in scintillator and a test of the linearity of light yield as a function of electron energy

File name: Supplementary Information Description: Supplementary Figures, Supplementary Notes and Supplementary References

Supplemental material for Bound electron nonlinearity beyond the ionization threshold

SUPPLEMENTARY INFORMATION

No. 9 Experimental study on the chirped structure of the construct the early time spectra. [14;15] The prevailing account of the chirped struct

B 2 P 2, which implies that g B should be

Brewster Angle and Total Internal Reflection

Connecting metallic nanoparticles by optical

Progress Report on the A4 Compton Backscattering Polarimeter

Interference. Reminder: Exam 2 and Review quiz, more details on the course website

Plasma Formation and Self-focusing in Continuum Generation

Development of Polarization Interferometer Based on Fourier Transform Spectroscopy for Thomson Scattering Diagnostics

Gratings in Electrooptic Polymer Devices

Comparing quantum and classical correlations in a quantum eraser

Brewster Angle and Total Internal Reflection

Elements of Quantum Optics

Long-Range Phase-Conjugate Interferometry

Electrophoretic Light Scattering Overview

Time resolved optical spectroscopy methods for organic photovoltaics. Enrico Da Como. Department of Physics, University of Bath

Introduction to Fourier Transform Infrared Spectroscopy

Michelson Interferometer. crucial role in Einstein s development of the Special Theory of Relativity.

Lecture 11: Introduction to diffraction of light

Transcription:

Low-coherence heterodyne photon correlation spectroscopy J.H. Johnson, S.L. Siefken, A. Schmidt, R. Corey, and P. Saulnier Department of Physics, Gustavus Adolphus College Saint Peter, MN 56082 ABSTRACT Photon Correlation Spectroscopy (PCS) is routinely used to investigate the dynamics of colloidal particles undergoing Brownian motion. This technique is applicable to low-density colloidal suspensions where the effects of multiple light scattering are minimal. We introduce a new low-coherence heterodyne PCS technique that allows direct investigation of colloidal suspensions of higher concentration than previously accessible using standard PCS. In this technique, low-coherence optical heterodyne interferometry is used to suppress multiple light scattering, allowing preferential detection of single scattering events. PACS Numbers: 42.62.Fi, 42.68.Mj, 42.81.Dp 1

1. INTRODUCTION Photon correlation spectroscopy (PCS) is a time-domain dynamic light scattering technique that seeks to extract information about the dynamics of colloidal particles in suspension. The modern roots of this technique date from the early 1960's. Since that time PCS has been used to investigate a wide variety of colloidal suspensions in the fields of biology, chemistry, and physics. Despite its practical success, PCS is limited to very dilute (single scattering) samples. This makes it impossible to apply this technique to study the particle dynamics of a wide range of naturally occurring colloidal suspensions without dilution. More recently diffusing wave spectroscopy (DWS) has been introduced as a technique to study dynamics of colloidal particles in dense random media where multiple scattering dominates. DWS allows useful information about particle dynamics to be extracted from samples where the photon behavior is diffusive, L, where L is the sample cell thickness and is the photon transport mean-free-path length or random walk step size. In this paper, we describe a low-coherence heterodyne photon correlation spectroscopic transmission technique which extends the scatterer concentration range that can be successfully investigated in a photon correlation experiment. This technique enables the study of colloidal suspensions that possess a threefold increase in concentration beyond what can be probed by traditional PCS. This new technique partially fills a concentration niche between traditional PCS and DWS. We find that the scattering coefficient, i.e. the number of scattering events per unit sample length, is the critical parameter that determines the range of applicability of low-coherence photon correlation spectroscopy. 2. DESCRIPTION OF THE EXPERIMENT We have used a low-coherence heterodyne detection scheme to suppress multiply scattered light and preferentially detect single scattering events. Figure 1 illustrates the modified Mach-Zehnder experimental arrangement. Two laser sources were used, in turn, to investigate the effect of source coherence length. The long coherence length source was a HeNe laser (633 nm) possessing a coherence length of 0.4 m, while the short coherence length source was a diode laser (800 nm) with a 400 m coherence length. The aperture in front of the photo-diode detector PD was a 200 m pinhole and the sample to detector distance was 46 cm. 2

SAMPLE θ PH3 BS1 80.1 MHz 80 MHz PH1 BS2 AOM2 BE SF{ AOM1 PH2 PD Laser TS Lock-in Figure 1 Figure 1: The modified Mach-Zehnder interferometer used to conduct a heterodyne photon correlation spectroscopic experiment. A diode laser (800 nm) and a HeNe laser (633 nm) were used along with other major components; SF, spatial filter; BS1, BS2, beamsplitters; AOM1, AOM2, acousto-optic modulators; BE, beam expander; TS, translation stage; PH1 (1 mm), PH2 (200 m), PH3 (1 mm), pinholes; and PD, a photodiode detector. The lock-in reference was obtained by electronically mixing the 80.1 MHz and 80 MHz signals. The light in the reference arm of the interferometer (lower arm of Fig. 1) was Doppler shifted by using two acousto-optic modulators (AOMs). The first modulator upshifted the frequency by 80.1 MHz while the second modulator downshifted it by 80 MHz. This provides the net 100 khz frequency shift necessary for our lock-in detection scheme. It should be noted that the diode laser possessed sufficient coherence to allow normal AOM operation. A right angle prism mounted on a motorized translation stage provided the variable delay required to match the optical path lengths of the two interferometer arms. The key experimental idea is that the path length of the two interferometer arms are matched for light that has scattered once in the sample cell. Such single scattered light will add coherently with light from the reference arm while light that has multiply 3

scattered a distance greater than the source coherence length will add incoherently. The coherent component of the detected signal may only be a small fraction of the optical radiation impinging on the detector. This coherent component, however, will be seen to beat at 100 khz, owing to the Doppler shifted reference arm. Thus, the lock-in amplifier will detect a 100 khz signal whose magnitude is fluctuating due to scatterer motion while ignoring the larger incoherent intensity. The autocorrelation function of this fluctuating coherent signal is computed and fit to the single exponential decay model appropriate for a monodisperse colloidal suspension, (1) where is a parameter related to the number of coherence areas seen by the detector, is the translational diffusion constant of the colloidal particles, is the scattering vector, and the temporal variable. The translational diffusion constant for spherical particles is given by the Stokes-Einstein relation as where is Boltzmann's constant, the absolute temperature, the viscosity of the suspending fluid, and the colloidal particle radius. The scattering vector is related to the scattering angle by sin, where is the wavelength of light in the suspending fluid. Thus, the characteristic decay time of the intensity autocorrelation function for a suspension of monodisperse colloidal particles can be varied significantly by changing the scattering angle. A scattering angle of approximately 10 was used so that the detected intensity fluctuations would be slow enough to permit lockin detection. The path lengths of the two interferometer arms were initially matched by replacing the sample cell in Fig. 1 with a deflection mirror, adjusted for 10 deflection ( ), and a compensating cell. This compensating cell was our standard sample cell filled with filtered water. The translation stage (TS) was then adjusted until the maximum beat signal was observed on the lock-in (i.e. the interferometer arms were of equal optical path length). This initial alignment procedure yielded an interferometer that was close to the final matched condition. The interferometer was converted to its final experimental configuration, shown in Fig. 1, by removal of the deflection mirror with the compensating cell now playing the role of sample cell. Final optical path length matching was accomplished by filling the sample cell with the colloidal suspension to be studied. (2) 4

The motorized translation stage (TS) was then moved under computer control and the laser source interferogram recorded, essentially the beat signal amplitude versus optical path length difference. During this matching procedure the lock-in time constant was greatly increased to average out the intensity fluctuations caused by scatterer motion. It is, of course, just such intensity fluctuations that will be analyzed in this study. The position of zero path length difference is clearly seen on the resulting interferograms as it corresponds to the location of maximum fringe visibility (or equivalently maximum beat amplitude), (see Fig. 2). Finally, the translation stage was adjusted to this zero path length difference location and the lock-in time constant was reduced to allow the desired intensity fluctuations to be recorded. 1.0 0.8 Fringe Visibility 0.6 0.4 0.2 0.0-4 -3-2 -1 0 1 2 3 4 Path Length Difference [mm] Figure 2 Figure 2: Diode laser (800 nm) interferogram. Zero interferometer optical path length difference is indicated as the location of maximum fringe visibility. Regions of enhanced visibility, coherent side modes, are also clearly indicated outside of the central coherent peak. 5

3. DISCUSSION OF RESULTS The aqueous colloidal suspensions used in this study were of monodisperse polystyrene spheres of 0.997 m mean diameter with a dispersion of less than 2%. This mean diameter was determined by the manufacturer using electron microscopy. Care was taken to avoid particle settling by addition of deuterium-oxide (DO) to the suspending fluid, making the polystyrene spheres neutrally buoyant. The volume fractions utilized ranged from 0.001% to 0.01% yielding from one-third to three scattering mean-free-path lengths across our 1 cm sample cell. We find that the number of scattering path lengths across the sample cell (L, where is the calculated photon scattering mean-free-path length) is the relevant experimental parameter, rather than the volume fraction. For example, a 0.01% aqueous suspension of 1 m polystyrene spheres yields the same number of scattering lengths across a 1 cm cell as a 0.1% suspension across a 1 mm cell or a 7.0% suspension of 0.1 m spheres across the same 1 mm cell. The dramatic difference in volume fraction necessary to achieve the same scattering coefficient for various scatterer diameters is due to dramatic discrepancies in the corresponding Mie cross-sections for the respective particle sizes. Data were collected for both the long and short coherence length sources over the entire range of volume fractions probed. Figure 3 illustrates the long coherence length data. The vertical axis represents the experimentally determined scatterer diameter divided by the manufacturer's stated diameter. Thus, a value of one represents agreement with the stated scatterer size. The horizontal axis represents scatterer concentration (increasing from left to right) as the number of photon scattering mean-free-path lengths across the sample cell. Figure 3 clearly shows that the experimentally extracted scatterer size is accurate until the single scattering limit is exceeded. Once the single scattering limit is exceeded L there is a dramatic decrease in the apparent scatterer size corresponding to a dramatic increase in the intensity autocorrelation decay rate. One expects the intensity fluctuations to be more rapid when multiple scattering is involved and Fig. 3 dramatically illustrates this fact. The inset shows a typical intensity autocorrelation function and fit (to eqn. 1) obtained with the long coherence length source for L. 6

1.20 1.0 d exp / d manf 1.00 0.80 0.60 0.40 Correlation 0.965 0 Time [s] 2 0.20 Figure 3 0.00 0.00 0.50 1.00 1.50 2.00 L/l Figure 3: Experimentally determined scatterer diameter ( ) expressed as a fraction of the manufacturer's reported diameter ( ) versus optical thickness, where cm is the sample cell thickness and is the photon scattering mean-free-path length. Data was obtained using 0.997 m polystyrene spheres in water with a HeNe laser source possessing a coherence length of 0.4 m. Inset shows a typical normalized correlation function and corresponding fit for L. Figure 4 summarizes the short coherence length data. The scatterer concentration, reported as L, that can be successfully probed has increased by a factor of three while the actual volume fraction has increased somewhat more, due to the wavelength difference of the two laser sources. The regime probed by this low-coherence technique is beyond the single scattering limit and yet has not entered the diffusive regime as L. Again, the inset shows a typical intensity autocorrelation function and fit obtained, this time with the short coherence length source, for L. 7

1.20 1.00 d exp / d manf 0.80 0.60 0.40 1.00 Correlation 0.20 0.95 0 Time [ms] 500 Figure 4 0.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 L/l Figure 4: Experimentally determined scatterer diameter ( ) expressed as a fraction of the manufacturer's reported diameter ( ) versus optical thickness, where cm is the sample cell thickness and is the photon scattering mean-free-path length. Data was obtained using 0.997 m polystyrene spheres in water with a diode laser source possessing a coherence length of 400 m. Inset shows a typical normalized correlation function and corresponding fit for L. The difference in time-scale probed for the two laser sources is a result of differing wavelength and a small change in scattering angle. Both the short and long coherence length data indicate an increase in intensity autocorrelation decay rate as the single scattering regime is exceeded. Contributions from higher order scattering cause the characteristic intensity fluctuations to be more rapid and thus increase the intensity autocorrelation decay rate. This increased decay rate leads to an underestimate of the scatterer diameter,. It is noted that this underestimate occurs more gradually for the short coherence length data (Fig. 4) than for the long coherence length data (Fig. 3) as their respective maximum L are exceeded. This agrees with expectations as all scattering ( m) that takes place within the sample cell will be coherent with the reference arm when the long coherence length source is used while only those multiple scattering paths that are within the small coherence length ( m) of the short source will be detected during its use. Thus, 8

the rapidity with which multiple scattering negatively impacts the data collected using the long coherence length source is greater than that collected using the short coherence length source, as observed. The question that naturally arises is, what limits the concentration that can be successfully probed? The answer may lie in the interferogram of Fig. 2. This figure shows that outside the central region of high fringe visibility lie coherent side modes. That is, for example, if a photon in the sample arm multiply scatters a path length that exceeds the length of the reference arm by 1.3 mm it will again experience partial coherence with the reference arm and contribute to the detected signal rather than being rejected. A short coherence length light source without or with reduced coherent side modes may further extend the applicability of this technique. A super-luminescent diode (SLD) might be considered as a light source but it introduces the additional limitation of greatly reduced optical power, making even lock-in detection of the single scattered component difficult. 4. CONCLUSIONS In summary, we have shown that a low-coherence heterodyne photon correlation spectroscopic experiment extends the concentration of samples that can be successfully investigated into the multiple scattering regime. This technique partially fills a niche in that samples outside the regime of applicability of either traditional PCS or the newer DWS may be probed. 5. ACKNOWLEDGMENTS We are pleased to acknowledge support from Research Corporation, The Petroleum Research Fund, and the National Science Foundation (NSF-RUI #PHY- 9601988). R. Pecora, Doppler shifts in light scattering from pure liquids and polymer solutions, J. Chem. Phys. 40, 1604-1614 (1964). H.Z. Cummins, N. Knable, and Y. Yeh, Observation of diffusion broadening of Rayleigh scattered light, Phys. Rev. Lett. 12, 150-153 (1964). H.Z. Cummins and E.R. Pike, eds., Photon Correlation and Light-Beating Spectroscopy (Plenum Press, New York, N.Y., 1974). R. Pecora, ed., Dynamic Light Scattering, Applications of Photon Correlation Spectroscopy (Plenum Press, New York, N.Y., 1985), pp. 277-406. 9

D. Yu Ivanov and A. F. Kostko, Spectrum of multiply quasi-elastically scattered light, Opt. Spektrosc. 55, 950-953 (1983). D.J. Pine, D.A. Weitz, P.M. Chaikin, and E. Herbolzheimer, Diffusing-wave spectroscopy, Phys. Rev. Lett. 60, 1134-1137 (1988). G. Maret and P.E. Wolf, Multiple light scattering from disordered media: the effect of Brownian motion of scatterers, Z. Phys. B 65, 409-413 (1987). M.J. Stephen, Temporal fluctuations in wave propagation in random media, Phys. Rev. B 37, 1-5 (1988). M. Toida, M. Kondo, T. Ichimura, and H. Inaba, Two-dimensional coherent detection imaging in multiple scattering media based on the directional resolution capability of the optical heterodyne method, Appl. Phys. B 52, 391-394 (1991). A. Schmidt, R. Corey, and P. Saulnier, Imaging through random media by use of lowcoherence optical heterodyning, Opt. Lett. 20, 404-406 (1995). E. Jakeman, C.J. Oliver, and E.R. Pike, The effects of spatial coherence on intensity fluctuation distributions of Gaussian light, J. Phys. A 3, L45-L48 (1970). 10