Discover what you re missing

Similar documents
Corona Veo the Next Generation Charged Aerosol Detector

Charged Aerosol Detection 101

Enhancement of Linearity and Response in Charged Aerosol Detection

Pharmaceutical Analysis of API and Counter Ions in Complex Formulations in a Single Injection

Charged Aerosol Detection See what other universal detectors are missing. Technical Guide

Quantitation and Characterization of Copper Plating Bath Additives by Liquid Chromatography with Charged Aerosol Detection

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

Varian 380-LC. ELSD for Routine HPLC and GPC Analysis. Key Benefits

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

Quantitation of Surfactants in Samples by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

No Chromophore? No Problem! Universal HPLC Detection. The world leader in serving science

Sensitive HPLC Method for Triterpenoid Analysis Using Charged Aerosol Detection with Improved Resolution

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Agilent 1260 Infinity Evaporative Light Scattering Detector (ELSD)

Quantitation and Characterization of Copper and Nickel Plating Bath Additives by Liquid Chromatography

Direct Analysis of Surfactants using HPLC with Charged Aerosol Detection

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

Agilent 385-ELSD Evaporative Light Scattering Detector

Analysis of Silicone Oils by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

Varian 385-LC. ELSD for Low Molecular Weight Compounds

LC Technical Information

Speed and flexibility

Agilent 385-ELSD Evaporative Light Scattering Detector

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Cation Exchange HPLC Columns

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

LC and LC/MS Column Selection Flow Chart

Analytical Instrumentation

Dionex IonPac AS28-Fast-4µm column

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Automated and accurate component detection using reference mass spectra

Charged Aerosol Detection and Evaporative Light Scattering Detection Fundamental Differences Affecting Analytical Performance

Defining quality standards for the analysis of solid samples

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Evaporative Light Scattering Detector (ELSD)

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative.

Selecting Detectors for Compounds with No Optical Absorbance

APPLICATION NOTE Goal. Introduction. Keywords

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

HPLC Analysis of Nonvolatile Analytes Using Charged Aerosol Detection

HPLC Analysis of Non-volatile Analytes Using

Translational Biomarker Core

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

MODERN HPLC FOR PRACTICING SCIENTISTS

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Fast methods for the determination of ibuprofen in drug products

TOXICOLOGY & FORENSIC APPLICATIONS

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

LIQUID CHROMATOGRAPHY

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Pulsar. Delivering NMR to your benchtop

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Comparison of different aqueous mobile phase HPLC techniques

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

IN QUALITATIVE ANALYSIS,

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

NANO 243/CENG 207 Course Use Only

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

Basic Principles for Purification Using Supercritical Fluid Chromatography

TANDEM MASS SPECTROSCOPY

Expanded capabilities in ammonium and amine detection

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Use of Charged Aerosol Detection as an Orthogonal Quantification Technique for Drug Metabolites in Safety Testing (MIST)

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

with diode array detection

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Guide to Peptide Quantitation. Agilent clinical research

Accurate Mass Analysis of Hydraulic Fracturing Waters

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Analytical Methods to Qualify and Quantify PEG and PEGylated Biopharmaceuticals

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Extraction Process Validation of Isatis Radix

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

UNIT 3 CHEMISTRY. Fundamental Principles in Chemistry

Chapter content. Reference

It s hot! ZIC -chilic

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

GPC/SEC An essential tool for polymer analysis

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Transcription:

Discover what you re missing Thermo Scientific Corona Veo Charged Aerosol Detector

Hidden peaks revealed The analyte detection challenge No single liquid chromatography (LC) detector delivers ideal results. Often, one analyte responds more strongly than another, or may not respond at all. What is most desired is the ability to accurately measure a wide range of analytes with consistent response. Charged aerosol detection (CAD) is a revolutionary technology that will change the way you view every sample. This technique provides consistent analyte response independent of chemical structure and gives excellent sensitivity over a wide dynamic range. UV at 0 nm UV at 54 nm Void + Cl - Propanolol Ketoprofen Verapamil Charged Aerosol Detection With the flexibility and performance for analytical R&D, and the simplicity and reproducibility needed for manufacturing QC/QA, charged aerosol detection can be used for the analysis of pharmaceuticals (large and small molecule), biomolecules, foods and beverages, specialty chemicals, and polymers. MS TIC (+ ion scan 150-500AMU) 0 0.5 1 1.5 Minutes A charged aerosol detector opens new opportunities for discovery and routine analysis the ideal detector for every lab giving consistent analyte response independent of chemical structure and excellent sensitivity over a wide dynamic range. Comparison of charged aerosol detection to ultraviolet (UV) and mass spectroscopy (MS)

Understanding charged aerosol detection Charged aerosol detection measures signals that are proportional to the amount of analytes present in a sample. These signals are derived from the measurement of an electrical charge originating from ionized nitrogen that is diffusionally transferred to the surface of the analyte particle. This technology quantifies any analyte particles that this charge, including analytes that cannot ionize or do not have a chromophore. The result is accurate and consistent response, regardless of analyte structure. With charged aerosol detection, you can measure any nonvolatile and most semivolatile analytes. Three simple steps 1 3 Charged aerosol detection begins by nebulizing the eluent into droplets, which are subsequently dried into particles. The particle size increases with the amount of analyte. A stream of charged gas collides with the analyte particles. The charge is then transferred to the particles the larger the particles, the greater the charge. The particles are transferred to a collector where the charge is measured by a highly sensitive electrometer. This generates a signal in direct proportion to the quantity of analyte present. 1 3 Charged aerosol technology 3

An evolution for charged aerosol detection The Thermo Scientific Corona Veo detector improves the capabilities and extends the advantages of charged aerosol detection. The Corona Veo detector combines all the benefits of CAD for the high speed and increased resolution of UHPLC, along with improved low flow performance for micro LC. This detector widens the envelope of LC conditions for mobile phase composition to take advantage of ever advancing column technologies. Simple, intuitive operation Enhanced linear dynamic range The Corona Veo detector incorporates an advanced concentric nebulizer design that facilitates the use of an expanded range of flows and eluents: Easy-to-access design for maximized uptime Micro LC flow optimized Designed for simple capillary connections Sub-nanogram sensitivity Expanded flow rate range optimized from 0.01 to.0 ml/min 9.50 8.00 Amikacin The FocusJet nebulizer 6.00 4.00.00 Sulfate Unknown Impurity 1-0.10 0.00 0.50 1.00 1.50.00.50 The UHPLC analysis of amikacin impurities using micro LC flow rate of 50 µl/min Unknown Impurity 4

Easy integration with any LC system The Corona Veo detector is designed to integrate into any liquid chromatographic system, HPLC or UHPLC, from any manufacturer. The stackable design and rugged construction allow positioning anywhere within a system. The UltiMate solution Combine the Corona Veo detector with the Thermo Scientific UltiMate 3000 LC system to provide an ideal solution for approximation of relative analyte concentrations, even when standards are not available. Widen the scope of your detection possibilities using orthogonal and complementary solutions by pairing with UV or mass spectrometry. This approach maximizes the amount of compound data obtained from a single analytical run. Removable knurl Fingertight screw Adapter (no ferrule!) PEEK seal Get better LC connections with the Thermo Scientific Viper Fingertight Fitting System for virtually zero-dead volume connections up to 1500 bar. The Viper design ensures tool-free connections for the entire fluidic pathway for any LC system connected to the Corona Veo charged aerosol detector for best chromatographic results. 5

Flexibility for many analytes Charged aerosol detection is an ideal primary LC detection technology that delivers predictable results without intricate optimization. There are a minimum number of parameters to optimize enabling you to quickly begin generating data. This detector can be used in a range of applications from basic research to quality control. Lipids Lipids, including fats and oils, contain molecules with a wide variety of structural properties and are found throughout many products and industries. These are traditionally difficult to characterize with conventional detection technologies. Charged aerosol detection is a powerful tool for lipid analysis due to its structureindependent response. 500 400 300 00 100 Triglycerides Paraffins Alkyl Esters Monoglycerides Diglycerides Fatty Alcohols Fatty Acids -50 0.0 10.0 0.0 30.0 40.0 50.0 65.0 Universal lipids analysis of algal oils Pharmaceutical product characterization Using HPLC-HILIC methodologies, counterions along with their parent compound can be analyzed simultaneously with the Corona Veo detector. This approach helps speed selection of final product formulations. 10.0 Sodium Diclofenac 8.0 160 140 10 Sodium Diclofenac 6.0 4.0.0 0.0 -.0 Chloride 100 80 60-5.0 0.00 0.5 0.50 0.75 1.00 1.5 1.50 1.75.00.5.50 40 Fast analysis of diclofenac, its counterion, and impurity 0-6 0.00 0.5 0.50 0.75 1.00 1.5 1.50 1.75.00.5.50 6

Industrial water treatment Polyacrylic acid, a biodegradable water soluble polymer and environmentally toxic agent, is used as an anti-scaling inhibitor in circulating water systems. The low levels present in water samples are difficult to characterize using standard methods. This example shows detection by CAD at low ppb levels. 0.800 0.65 0.500 0.375 0.50 0.15 6 5 4 3 1 Polyacrylic acid -0.100 0.0 1.0.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 Polyacrylic acid in cooling water 500 50 pg on-column Counter-ion salts C Carbohydrates Traditional approaches for studying sugar fingerprints in foods can be limiting, often utilizing dedicated equipment. The Corona Veo detector offers the flexibility to use gradient HILIC modes of separation with dilute-and-shoot simplicity on any LC system. 130 100 80 60 40 0-0.00 0.50 1.00 1.50.00.50 3.00 3.50 4.00 4.50 5.00 5.50 Fructose Sorbitol Glucose UHPLC characterization of sugars in apple juice Sucrose Power function enhanced linearization The Power function provides several benefits when using charged aerosol detection. The use of this built-in feature can provide quantitative results from unresolved peaks in a chromatographic analysis, and simplify calibration curves for improved mass balance determinations. Peak Area (pa/min) Calibration Data using PFV Linear Regression Fit 18 R = 0.999 16 14 1 10 8 6 4 0 0 1000 000 3000 4000 5000 6000 Concentration (µg/ml) Peak Area (pa/min) Calibration Data No PFV Polynomial Regression Fit 40 R = 0.999 35 30 5 0 15 10 5 0 0 1000 000 3000 4000 5000 6000 Concentration (µg/ml) Extended linear dynamic range using the Power Function Value (PFV) 7

Chromeleon 7. CDS, simply intelligent The Thermo Scientific Chromeleon Chromatography Data System (CDS) software delivers rich, intelligent functionality with Operational Simplicity. Reduced training effort for your lab staff: one single software package instead of several Comprehensive suite of Chromeleon CDS productivity tools from dynamic data linking, instant processing, to SmartPeaks detection One set of methods, one set of reports, and one central location for your chromatographic data Seamless integration and access to the online applications and methods library in the Thermo Scientific AppsLab Library of Analytical Applications AppsLab Library of Analytical Application Chromeleon 7. CDS combines separation (LC/IC/GC) and MS in an enterprise (client-server) environment to streamline your chromatography and quantitation workflows in one application. Everything you need is within easy reach to boost your overall lab productivity. Find out more at thermofisher.com/cad 013 017 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. BR70735-EN 1017M