Experiment P43: RC Circuit (Power Amplifier, Voltage Sensor)

Similar documents
RC Circuit (Power amplifier, Voltage Sensor)

Name Class Date. RC Circuit Lab

Old Dominion University Physics 112N/227N/232N Lab Manual, 13 th Edition

( ) ( ) = q o. T 12 = τ ln 2. RC Circuits. 1 e t τ. q t

Experiment P05: Position, Velocity, & Acceleration (Motion Sensor)

Measuring the time constant for an RC-Circuit

Lab 10: DC RC circuits

Experiment P30: Centripetal Force on a Pendulum (Force Sensor, Photogate)

Experiment P09: Acceleration of a Dynamics Cart I (Smart Pulley)

Experiment P14: Collision Impulse & Momentum (Force Sensor, Motion Sensor)

LAB 3: Capacitors & RC Circuits

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Physics 8.02 Spring 2003 Experiment 17: RLC Circuit (modified 4/15/2003) OBJECTIVES

RC Circuit Lab - Discovery PSI Physics Capacitors and Resistors

Experiment P26: Rotational Inertia (Smart Pulley)

Name: Lab Partner: Section:

Experiment P13: Atwood's Machine (Smart Pulley)

ENERGY AND TIME CONSTANTS IN RC CIRCUITS By: Iwana Loveu Student No Lab Section: 0003 Date: February 8, 2004

University of TN Chattanooga Physics 1040L 8/18/2012 PHYSICS 1040L LAB LAB 4: R.C. TIME CONSTANT LAB

Experiment P17: Conservation of Linear Momentum II (Photogate)

PHY222 - Lab 7 RC Circuits: Charge Changing in Time Observing the way capacitors in RC circuits charge and discharge.

Lab 4 RC Circuits. Name. Partner s Name. I. Introduction/Theory

[1] (b) Fig. 1.1 shows a circuit consisting of a resistor and a capacitor of capacitance 4.5 μf. Fig. 1.1

Experiment 4. RC Circuits. Observe and qualitatively describe the charging and discharging (decay) of the voltage on a capacitor.

SOTM LAB: P16 OHM S LAW I. TEACHER NOTES & GUIDELINES TITLE OF LAB: Ohm s Law DEVELOPERS OF LAB:

EXPERIMENT 5A RC Circuits

Lab 1 Uniform Motion - Graphing and Analyzing Motion

Capacitors GOAL. EQUIPMENT. CapacitorDecay.cmbl 1. Building a Capacitor

Experiment P28: Conservation of Linear and Angular Momentum (Smart Pulley)

PHYS320 ilab (O) Experiment 2 Instructions Conservation of Energy: The Electrical Equivalent of Heat

Lab 5 RC Circuits. What You Need To Know: Physics 212 Lab

Electrostatic Charge Distribution (Charge Sensor)

Physics Labs with Computers, Vol. 1 P14: Simple Harmonic Motion - Mass on a Spring A

Lab 12 - Conservation of Momentum And Energy in Collisions

Capacitors. The charge Q on a capacitor s plate is proportional to the potential difference V across the Q = C V (1)

Figure 1: Capacitor circuit

Lab 6: Capacitors and Resistor-Capacitor Circuits Phy208 Spr 2008 Name Section

Laboratory 7: Charging and Discharging a Capacitor Prelab

Experiment 8: Capacitance and the Oscilloscope

Lab 5 RC Circuits. What You Need To Know: Physics 212 Lab

The RC Time Constant

Practical 1 RC Circuits

July 11, Capacitor CBL 23. Name Date: Partners: CAPACITORS. TI-83 calculator with unit-tounit. Resistor (about 100 kω) Wavetek multimeter

Simple circuits - 3 hr

Experiment Guide for RC Circuits

first name (print) last name (print) brock id (ab17cd) (lab date)

Physics Labs with Computers, Vol. 1 P23: Conservation of Angular Momentum A

Capacitor investigations

RC Circuits. Equipment: Capstone with 850 interface, RLC circuit board, 2 voltage sensors (no alligator clips), 3 leads V C = 1

Lab 4 CAPACITORS & RC CIRCUITS

Capacitance. A capacitor consists of two conductors that are close but not touching. A capacitor has the ability to store electric charge.

Physics Investigation 10 Teacher Manual

Lab 08 Capacitors 2. Figure 2 Series RC circuit with SPDT switch to charge and discharge capacitor.

PHYSICS 171 UNIVERSITY PHYSICS LAB II. Experiment 6. Transient Response of An RC Circuit

1) Two lightbulbs, one rated 30 W at 120 V and another rated 40 W at 120 V, are arranged in two different circuits.

Activity P27: Speed of Sound in Air (Sound Sensor)

Tactics Box 23.1 Using Kirchhoff's Loop Law

PHYSICS 122 Lab EXPERIMENT NO. 6 AC CIRCUITS

Exercise 1: RC Time Constants

Laboratory Worksheet Experiment NE04 - RC Circuit Department of Physics The University of Hong Kong. Name: Student ID: Date:

Phys 2025, First Test. September 20, minutes Name:

Lab 3 - Capacitors. Stony Brook Physics Laboratory Manuals. Equipment

CALIFORNIA STATE UNIVERSITY, BAKERSFIELD (CSUB) Laboratory 3

Chapter 6. Answers to examination-style questions. Answers Marks Examiner s tips

College Physics II Lab 8: RC Circuits

farads or 10 µf. The letter indicates the part tolerance (how close should the actual value be to the marking).

RC Studies Relaxation Oscillator

Exam 3--PHYS 102--S14

Chapter 19 Lecture Notes

EXPERIMENT 07 TO STUDY DC RC CIRCUIT AND TRANSIENT PHENOMENA

DEPARTMENT OF COMPUTER ENGINEERING UNIVERSITY OF LAHORE

Activity P60: Inverse Square Law Nuclear (Nuclear Sensor, Rotary Motion Sensor)

Capacitor in the AC circuit with Cobra3

WELCOME TO PERIOD 14. Homework Exercise #13 is due today. Watch video 3 Edison s Miracle of Light for class discussion next Tuesday or Wednesday.

Class #12: Experiment The Exponential Function in Circuits, Pt 1

Activity P15: Simple Harmonic Oscillation (Force Sensor, Photogate)

Lab 5 CAPACITORS & RC CIRCUITS

Blackbody Radiation EX-9920 ScienceWorkshop Page 1 of 8. Blackbody Radiation

RC, RL, and LCR Circuits

Activity P08: Newton's Second Law - Constant Force (Force Sensor, Motion Sensor)

Activity P11: Collision Impulse and Momentum (Force Sensor, Motion Sensor)

Physics 24 Exam 2 March 18, 2014

Lab 5 - Capacitors and RC Circuits

LABORATORY 4 ELECTRIC CIRCUITS I. Objectives

COPYRIGHTED MATERIAL. DC Review and Pre-Test. Current Flow CHAPTER

On the axes of Fig. 4.1, carefully sketch a graph to show how the potential difference V across the capacitor varies with time t. Label this graph L.

Physics 102: Lecture 7 RC Circuits

ECE 241L Fundamentals of Electrical Engineering. Experiment 5 Transient Response

CAPACITORS / ENERGY STORED BY CAPACITORS / CHARGING AND DISCHARGING

Electromotive Force. The electromotive force (emf), ε, of a battery is the maximum possible voltage that the battery can provide between its terminals

Experiment FT1: Measurement of Dielectric Constant

Lab #4 Capacitors and Inductors. Capacitor Transient and Steady State Response

Driven Harmonic Oscillator

Lab 5 - Capacitors and RC Circuits

Physics 126 Fall 2004 Practice Exam 1. Answer will be posted about Oct. 5.

The Basic Capacitor. Dielectric. Conductors

Exercise 1: Capacitors

Capacitors are devices which can store electric charge. They have many applications in electronic circuits. They include:

Physics 2135 Exam 2 March 22, 2016

Electronics Capacitors

RC Circuits (32.9) Neil Alberding (SFU Physics) Physics 121: Optics, Electricity & Magnetism Spring / 1

Transcription:

PASCO scientific Vol. 2 Physics Lab Manual: P43-1 Experiment P43: (Power Amplifier, Voltage Sensor) Concept Time SW Interface Macintosh file Windows file circuits 30 m 700 P43 P43_RCCI.SWS EQUIPMENT NEEDED FROM AC/DC ELECTRONICS LAB* Interface capacitor, 330 microfarad (330 µf) Power Amplifier resistor, 100 ohm (100 Ω) Voltage Sensor LCR Meter (optional) (2) Patch Cords (*The AC/DC Electronics Laboratory is PASCO EM-8656.) PURPOSE The purpose of this laboratory activity is to investigate how the voltage across a capacitor varies as it charges and to find the capacitive time constant. THEORY When a DC voltage source is connected across an uncharged capacitor, the rate at which the capacitor charges up decreases as time passes. At first, the capacitor is easy to charge because there is very little charge on the plates. But as charge accumulates on the plates, the voltage source must do more work to move additional charges onto the plates because the plates already have charge of the same sign on them. As a result, the capacitor charges exponentially, quickly at the beginning and more slowly as the capacitor becomes fully charged. The charge on the plates at any time is given by: q=q o 1 e t τ ( ) where qo is the maximum charge on the plates and τ is the capacitive time constant (τ = RC, where R is resistance and C is capacitance). NOTE: The stated value of a capacitor may vary by as much as ±20% from the actual value. Taking the extreme limits, notice that when t = 0, q = 0 which means there is not any charge on the plates initially. Also notice that when t goes to infinity, q goes to qo which means it takes an infinite amount of time to completely charge the capacitor. The time it takes to charge the capacitor to half full is called the half-life and is related to the time constant in the following way: t 1 2 = τ ln2 In this activity the charge on the capacitor will be measured indirectly by measuring the voltage across the capacitor since these two values are proportional to each other: q = CV. dg 1996, PASCO scientific P43-1

P43-2: Physics Lab Manual Vol. 2 PASCO scientific PROCEDURE In this activity, the Power Amplifier produces a low frequency square wave (0 to 4 V). This waveform imitates the action of charging and then discharging a capacitor by connecting and then disconnecting a DC voltage source. The Voltage Sensor measures the voltage across the capacitor as it charges and discharges. The program records and displays the data. You will measure the time for the capacitor to charge to the half-maximum voltage. Using the half-life time and the known value of the resistor, you can calculate the capacitance of the capacitor. PART I: Computer Setup 1. Connect the interface to the computer, turn on the interface, and turn on the computer. 2. Connect the Voltage Sensor to Analog Channel A. Connect the Power Amplifier to Analog Channel B. Plug the power cord into the back of the Power Amplifier and connect the power cord to an appropriate electrical outlet. 3. Open the document titled as shown: Macintosh P43 Windows P43_RCCI.SWS The document opens with a Graph display of Voltage (V) versus Time (sec), and the Signal Generator window which controls the Power Amplifier. Note: For quick reference, see the Experiment Notes window. To bring a display to the top, click on its window or select the name of the display from the list at the end of the Display menu. Change the Experiment Setup window by clicking on the Zoom box or the Restore button in the upper right hand corner of that window.) P43-2 1996, PASCO scientific dg

PASCO scientific Vol. 2 Physics Lab Manual: P43-3 4. The Sampling Options for this activity are: Periodic Samples = Fast at 1000 Hz and Stop Condition = Time at 4.00 seconds.. 5. The Signal Generator is set to output 4.00 V, positive only square AC Waveform, at 0.40 Hz. It is set to Auto so the Signal Generator will start automatically when you click MON or REC and stop automatically when you click STOP or PAUSE. PART II: Sensor Calibration and Equipment Setup You do not need to calibrate the Voltage Sensor or the Power Amplifier. 1. Place a 100 ohm (Ω) resistor (brown, black, brown) in the pair of component springs nearest to the top banana jack at the lower right corner of the AC/DC Electronics Lab circuit board. 2. Connect a 330 microfarad (µf) capacitor between the component spring on the left end of the 100 Ω resistor and the component spring closest to the bottom banana jack. 3 VOLT BULBS KIT NO. Battery + A B C 3.3 Ω 3 VOLTS MAX 3 VOLTS MAX E C CW B 100 Ω resistor Battery + 330 µf capacitor TO POWER AMPLIFIER VOLTAGE SENSOR (WITH CLIPS) dg 1996, PASCO scientific P43-3

P43-4: Physics Lab Manual Vol. 2 PASCO scientific 3. Put alligator clips on the Voltage Sensor banana plugs. Connect the alligator clips to the wires at both ends of the 330 µf capacitor. 4. Connect banana plug patch cords from the output of the Power Amplifier to the banana jacks on the AC/DC Electronics Lab circuit board. Part III: Data Recording 1. Turn on the power switch on the back of the Power Amplifier. 2. Click the REC button ( ) to start collecting data. The Signal Generator output will automatically start when data recording begins. 3. Data recording will continue for four seconds and then stop automatically. Run #1 will appear in the Data list in the Experiment Setup window. 4. When data recording is complete, turn off the switch on the back of the Power Amplifier. ANALYZING THE DATA 1. Click the Autoscale button ( ) in the Graph to rescale the Graph to fit the data. 2. Click the Magnifier button ( ). Use the cursor to click-and-draw a rectangle over a region of the plot of Voltage versus Time that shows the voltage rising from zero volts to the maximum volts. P43-4 1996, PASCO scientific dg

PASCO scientific Vol. 2 Physics Lab Manual: P43-5 This will give you an expanded view of the Voltage versus Time plot for that region. 3. Click the Smart Cursor button ( ). The cursor changes to a cross-hair when you move the cursor into the display area of the Graph. The Y-coordinate of the cursor/cross-hair is shown next to the vertical axis. The X-coordinate of the cursor/cross-hair is shown next to the horizontal axis. 4. Move the cursor to the point on the plot where the voltage begins to rise. Record the time that is shown in the area below the horizontal axis. 5. Move the Smart Cursor to the point where the voltage is approximately 2.00 volts. Record the new time that is shown in the area below the horizontal axis. 6. Find the difference between the two times and record it as the time to half-max, or t 1/2. dg 1996, PASCO scientific P43-5

P43-6: Physics Lab Manual Vol. 2 PASCO scientific ANALYZING THE DATA DATA Beginning time = s Time to 2.00 V = s Time to half-max (t 1/2 ) = s 1. Use t 1 2 = τ ln2 = 0.693 RC to calculate the capacitance (C) of the capacitor. Capacitance = farad 2. If a capacitance meter is available, use it to measure the capacitance of the capacitor. Using the percent difference method, compare the measured value to the experimental value. (Remember, the stated value of a capacitor may vary by as much as ±20% from the actual measured value.) If a capacitance meter is not available, use the percent difference method and compare the stated value (e.g., 330 µf) to the experimental value. QUESTIONS 1. The time to half-maximum voltage is how long it takes the capacitor to charge half-way. Based on your experimental results, how long does it take for the capacitor to charge to 75% of its maximum? 2. After four half-lives (i.e., time to half-max), to what percentage of the maximum charge is the capacitor charged? 3. What is the maximum charge for the capacitor in this experiment? 4. What are some factors that could account for the percent difference between the stated and experimental values? P43-6 1996, PASCO scientific dg