EVS28 KINTEX, Korea, May 3-6, 2015

Similar documents
Design of the Forced Water Cooling System for a Claw Pole Transverse Flux Permanent Magnet Synchronous Motor

Water-Cooled Direct Drive Permanent Magnet Motor Design in Consideration of its Efficiency and Structural Strength

CFD Analysis of Forced Convection Flow and Heat Transfer in Semi-Circular Cross-Sectioned Micro-Channel

TEFC Induction Motors Thermal Models: A Parameter Sensitivity Analysis

STAR-CCM+ and SPEED for electric machine cooling analysis

Design and analysis of Axial Flux Permanent Magnet Generator for Direct-Driven Wind Turbines

Lumped parameter thermal modelling

THERMAL ANALYSIS OF AN INDUCTION MOTOR BY HYBRID MODELING OF A THERMAL EQUIVALENT CIRCUIT AND CFD

L10 Thermal Design. EIEN20 Design of Electrical Machines, IEA, Forced cooling. Heat dissipation. Previously.

Study and Characterization of the Limiting Thermal Phenomena in Low-Speed Permanent Magnet Synchronous Generators for Wind Energy

Third harmonic current injection into highly saturated multi-phase machines

Prof. N. V. Sali 1, Pooja Kulkarni 2 1, 2

Y.K. Chin, D.A. Staton

Keywords: Electric Machines, Rotating Machinery, Stator faults, Fault tolerant control, Field Weakening, Anisotropy, Dual rotor, 3D modeling

Comparison of heat transfer characteristics of liquid coolants in forced convection cooling in a micro heat sink

Lecture 30 Review of Fluid Flow and Heat Transfer

Transient thermal modelling of an Axial Flux Permanent Magnet (AFPM) machine with model parameter optimisation using a Monte Carlo method

A concept for the integrated 3D flow, heat transfer and structural calculation of compact heat exchangers

Cooling System for High Energy Efficient Electric Motors

Forced Convection: Inside Pipe HANNA ILYANI ZULHAIMI

White Rose Research Online URL for this paper:

Parameter Prediction and Modelling Methods for Traction Motor of Hybrid Electric Vehicle

Thermal Analysis & Design Improvement of an Internal Air-Cooled Electric Machine Dr. James R. Dorris Application Specialist, CD-adapco

Accurate Joule Loss Estimation for Rotating Machines: An Engineering Approach

CPPM Mahine: A Synchronous Permanent Magnet Machine with Field Weakening

Examination Heat Transfer

8.1 Technically Feasible Design of a Heat Exchanger

Computational Fluid Dynamics Thermal Prediction of Fault-Tolerant Permanent-Magnet Motor Using a Simplified Equivalent Model

Experimental identification of the equivalent conductive resistance of a thermal elementary model of an induction machine

Doubly salient reluctance machine or, as it is also called, switched reluctance machine. [Pyrhönen et al 2008]

Numerical simulation of fluid flow in a monolithic exchanger related to high temperature and high pressure operating conditions

NUMERICAL AND EXPERIMENTAL INVESTIGATION OF THE TEMPERATURE DISTRIBUTION INSIDE OIL-COOLED TRANSFORMER WINDINGS

Concept Design and Performance Analysis of HTS Synchronous Motor for Ship Propulsion. Jin Zou, Di Hu, Mark Ainslie

Analysis of the Cooling Design in Electrical Transformer

This is a repository copy of Analytical modelling of modular and unequal tooth width surface-mounted permanent magnet machines.

Thermo-Hydraulic performance of Internal finned tube Automobile Radiator

Laminar flow heat transfer studies in a twisted square duct for constant wall heat flux boundary condition

Finite Element Method based investigation of IPMSM losses

International Journal of Scientific & Engineering Research, Volume 6, Issue 5, May ISSN

Thermal Properties of a Prototype Permanent Magnetized Electrical Motor Embedded in a Rim Driven Thruster

is another important aspect of the machine design. The machine components are often influenced

Thermal and Mechanical Analysis of PM Assisted Synchronous Reluctance Motor for Washing Machines

Simplified Thermal Model of PM Motors in Hybrid Vehicle Applications Taking into Account Eddy Current Loss in Magnets

Heat Transfer Analysis of Machine Tool Main Spindle

A Thermal Improvement Technique for the Phase Windings of Electrical Machines

THE magnetic fluxes in the stator and rotor yokes of

International Journal of Thermal Sciences

Finite Element Analysis of Hybrid Excitation Axial Flux Machine for Electric Cars

Cogging Torque Reduction in Surface-mounted Permanent Magnet Synchronous Motor by Axial Pole Pairing

Power density improvement of three phase flux reversal machine with distributed winding

Influence of different rotor magnetic circuit structure on the performance. permanent magnet synchronous motor

Studies on flow through and around a porous permeable sphere: II. Heat Transfer

Experimental Assessment of Unbalanced Magnetic Force according to Rotor Eccentricity in Permanent Magnet Machine

OPTIMAL DESIGN OF CLUTCH PLATE BASED ON HEAT AND STRUCTURAL PARAMETERS USING CFD AND FEA

Characteristics Analysis of Claw-Pole Alternator for Automobiles by Nonlinear Magnetic Field Decomposition for Armature Reaction

THERMAL FIELD ANALYSIS IN DESIGN AND MANUFACTURING OF A PERMANENT MAGNET LINEAR SYNCHRONOUS MOTOR

Application of Computational Fluid Dynamics (CFD) On Ventilation-Cooling Optimization of Electrical Machines

Cfd Simulation and Experimentalverification of Air Flow through Heated Pipe

INFLUENCE OF CURVED-SHAPE MAGNETS ON THE COOLING PERFORMANCE OF AN AXIAL FLUX PERMANENT MAGNET SYNCHRONOUS MACHINE

Measurement of stator heat transfer in air-cooled axial flux permanent magnet machines

Analytical Method for Predicting the Air-Gap Flux Density of Dual-Rotor Permanent- Magnet (DRPM) Machine

Physica C 468 (2008) Contents lists available at ScienceDirect. Physica C. journal homepage:

Eddy Current Heating in Large Salient Pole Generators

Dr. N. Senthilnathan (HOD) G. Sabaresh (PG Scholar) Kongu Engineering College-Perundurai Dept. of EEE

Jerad P. 10/1/2015. Motor Thermal Limits on Torque Production (Frameless Motor Level)

1439. Numerical simulation of the magnetic field and electromagnetic vibration analysis of the AC permanent-magnet synchronous motor

Conjugate Heat Transfer Simulation of Internally Cooled Gas Turbine Vane

IN THE PAST, the thermal analysis of electric machines has

Coupling Physics. Tomasz Stelmach Senior Application Engineer

Tutorial 1. Where Nu=(hl/k); Reynolds number Re=(Vlρ/µ) and Prandtl number Pr=(µCp/k)

The Nottingham eprints service makes this work by researchers of the University of Nottingham available open access under the following conditions.

Preliminary Sizing Design of a 1 MW Low Duty Cycle Switched Reluctance Generator for Aerospace Applications

CFD study for cross flow heat exchanger with integral finned tube

Transient Heat Transfer Experiment. ME 331 Introduction to Heat Transfer. June 1 st, 2017

Conjugate heat transfer from an electronic module package cooled by air in a rectangular duct

Analytical Model for Sizing the Magnets of Permanent Magnet Synchronous Machines

Cogging Torque Reduction in Surface-mounted Permanent Magnet Synchronous Motor by Axial Pole Pairing

Problem 4.3. Problem 4.4

Numerical investigation to study effect of radiation on thermal performance of radiator for onan cooling configuration of transformer

INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY

THE INFLUENCE OF THE ROTOR POLE SHAPE ON THE STATIC EFICIENCY OF THE SWITCHED RELUCTANCE MOTOR

Eddy-Current Loss Analysis of Copper-Bar Windings of Ultra High-Speed PM Motor

A REVIEW OF HEAT TRANSFER AND LAMINAR FLOW IN A MICROCHANNEL

ELECTRICAL AND THERMAL DESIGN OF UMBILICAL CABLE

Thermal-Electromagnetic Analysis of a Fault-Tolerant Dual Star Flux-Switching Permanent Magnet Motor for Critical Applications

Lumped-Parameter Thermal Network Model and Experimental Research of Interior PMSM for Electric Vehicle

An Introduction to Electrical Machines. P. Di Barba, University of Pavia, Italy

DOCUMENTATION OF CALCULATION OF THERMAL INSULATION RESISTANCE IN THE SLOT OF ELECTRIC MACHINES

IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 18, NO. 4, OCTOBER

Numerical analysis of fluid flow and heat transfer in 2D sinusoidal wavy channel

CONVECTIVE HEAT TRANSFER

6 Chapter 6 Testing and Evaluation

Analytical Model for Permanent Magnet Motors With Surface Mounted Magnets

HEAT TRANSFER AND FLOW CHARACTERISTICS OF OFFSET FIN AND FLAT TUBE HEAT EXCHANGERS UNDER LOW PRESSURE ENVIRONMENT

Loss analysis of a 1 MW class HTS synchronous motor

Design Optimization and Development of Linear Brushless Permanent Magnet Motor

EFFECT OF BAFFLES GEOMETRY ON HEAT TRANSFER ENHANCEMENT INSIDE CORRUGATED DUCT

Influence of Different End Region Cooling Arrangements on End-Winding Heat Transfer Coefficients in Electrical Machines

Experimental Tests and Efficiency Improvement of Surface Permanent Magnet Magnetic Gear

Analysis and Experiments of the Linear Electrical Generator in Wave Energy Farm utilizing Resonance Power Buoy System

Transcription:

EVS28 KINTEX, Korea, May 3-6, 2015 Comparison of Thermal Performance between Direct Coil Cooling and Water Jacket Cooling for Electric Traction Motor based on Lumped Parameter Thermal Network and Experimentation Zhengyu Liu 1, 2, Thomas Winter 1, Michael Schier 2 1 Robert Bosch GmbH, Stuttgart, Germany, 2 Institute of Vehicle Concepts in German Aerospace Center (DLR), Stuttgart, Germany Abstract This paper focuses on analyzing a novel direct coil cooling approach for electric traction motor. Its thermal performance is compared with conventional water jacket cooling concept by using analytical and experimental methods. Results show, the direct coil cooling approach has significant advantage regarding thermal performance, which allows the electric traction motor more suitable for high load applications. This study is performed on an ODIN switched reluctance prototype machine. For a convincing comparison result, the ODIN prototype is equipped with dedicated cooling circuits for each cooling approach. Based on the design parameters of the prototype, a lumped parameter thermal network (LPTN) model is established for analytical studies. For an accurate representation of heat transfer in the direct coil cooled motor through fluid flow, the key convective boundary is modeled based on the results of computational fluid dynamics (CFD). Studies with the developed LPTN model and experiments for validation are conducted. The results of the model analysis and the experiments both indicate that, through cooling coils directly in the stator slots with oil flows, direct coil cooled motor can effectively dissipate heat in the thermal critical winding areas. Current density in the ODIN prototype can be significantly increased. Thermal resistance from hotspots to coolant can be reduced by up to 80%. Direct coil cooling can increase the continuous torque output of ODIN machine to approx. 300%. Keywords: direct coil cooling, CFD, LPTN, electric machine, oil cooling Nomenclature μ b μ w A C D Dynamic viscosity of fluid bulk Dynamic viscosity near wall Surface area of heat transfer Matrix of thermal capacity Hydraulic diameter G h k L Nu P Pe Matrix of thermal conductance Heat transfer coefficient Thermal conductivity Characteristic length Nusselt number Vector of thermal energy Peclet number 1

Pr R Re T ref,o T ref,w Prandlt number Thermal resistance Reynolds number Reference temperature in direct coil cooled machine Reference temperature of water jacket cooled machine 1 Introduction In the recent years, electric machine gains more and more importance as traction machine in the automotive applications. Compare to combustion engine, electric machine is advantageous regarding torque output, efficiency, emission-free operation, etc. And it also provides possibility to recuperate kinetic and potential energy from the vehicle and in further reduces energy expense. Other than in the industrial applications, power density has a high relevance for traction machine, because space and weight are always limited in the vehicles. Therefore, during the development of traction machine, additional attentions to the thermal aspects are required. In all, it is the component temperature which determines the rated power of the machine. The winding area is one of the most sensitive positions, overheating can results in insulation breakdown and fatal damage. Besides, for permanent magnet synchronous machine (PMSM), the permanent magnets can also suffer from overheating [1]. There are in general following ways to improve machine thermal performance: reduce losses in the machine, improve heat dissipation, reduce coolant inlet temperature and raise component temperature limit. Previous study proposed a direct coil cooling approach, in which the improvement of heat dissipation is in the focus [2]. Figure 1 presents this cooling concept. The machine is cooled mainly in the stator slots by transmission oil flow. Figure 1. Concept of direct coil cooling The advantage of using oil for cooling is due to its dielectric characteristics. The oil can be directly applied to the electric winding areas where significant internal heat is generated. This configuration prevents extra thermal resistance that is built up by transmitting thermal energy from winding area to coolant through interjacent components, i.e. stator stack. However, oil is a medium with low thermal conductivity and capacity. Thus, fluid guiding structure, called baffle, is designed in the direct coil cooling concept to compensate the disadvantage. To utilize the thermal design improvements and convert them into load capability of the electric traction machines, the knowledge of temperature distribution in the machine components during operation can be crucial. To analyze the thermal behavior of direct coil cooled machine, this paper employs the lumped parameter thermal network (LPTN) approach [3] and combines it with modified Nusselt number correlation based on CFD results. Finally the thermal performance between direct coil cooling and standard water jacket cooling is compared through experiment and simulation. 2 Modeling of Direct Coil Cooled Electric Machine In the LPTN approach for modeling electric machine, the cooling medium, such as air and water, is considered as a boundary condition. Thus, the convective heat transfer is usually referred as film coefficient and is calculated based on the standard analytical correlations [4]. However, the correlations are established on studies of simplified channel geometries. Directly applying standard correlation on the application specified cooling channels could cause error in machine temperature estimation. For water jacket cooled machine the error is marginal. The heat transfer coefficient between water flow and surface is considerably higher compare to the thermal resistances in the machine structure. By direct coil cooled machine, the errors could be significant. Since, this cooling concept aims at bypassing thermal resistances in the machine structure. In addition, the heat transfer between oil flow and surface is much lower than that of water. Table 1 presents the influence of convective flow boundary on machine temperature. To correctly represent the machine model with fluid boundary, the author proposes to combine LPTN with computational fluid dynamic (CFD) analysis. 2

Table 1. Influence of convection flow boundary Direct coil cooled Water jacket cooled [9] Heat transfer coefficient offset [W/m 2 K] Hotspot temperature [ C] 900 T ref,o +18 1300 T ref,o 1700 T ref,o -10 6000 T ref,w 2.1 Modeling Approach 12000 T ref,w -6 By developing thermal model for direct coil cooled machine, lumped parameter approach is used as a basis. Within this approach the machine can be discretized into connected physical lumps, and represented by thermal nodes in the network model. The nodes include thermal capacity of the associated lumps, and are connected with each other through the thermal resistance between. By lumps which can generate internal heat energy, e.g. winding or stator, the thermal nodes are also connected with a heat source. The parameters of the LPTN can be entirely derived from machine design parameters and thermal properties of the materials that are used in the machine. Compare to FEA, analysis with LPTN is less accurate, but regarding computational time and adaption to system model the advantage is evident. This thermal network model principle can be also represented in a mathematical way through differential equation: C T t T The cooling fluid takes away heat in the electric machine, and is considered in the model as a boundary condition for solving the equation system. The temperature of the cooling fluid is set as constant, and its thermal resistance to the machine can be described with the following equation: R 1 In the conventional LPTN model this thermal resistance between fluid and wall is either estimated empirically [5] or calculated based on Nusselt correlation for idealized flow patterns [6] [7]. Limited correlations are specified for electric machines. In the Nusselt correlations, the Reynolds number, Prandlt number etc. can be used for calculating Nusselt number. The Nusselt number is a dimensionless quantitiy, which presents the ratio of convective to conductive heat transfer across the fluid-solid boundary. By solving the following equation with Nusselt number, the thermal resistance to the flow boundary in the thermal network model can be solved. Nu However, due to the complexity of thermal flow the Nusselt correlations are experimentally determined. By different flow channel geometries or even different flow speeds, the equation can be entirely different. In this paper by calculating the oil flow in the slot channel with CFD, a modified Nusselt correlation specifically for the studied channel is generated. In this way, the temperature calculation for direct coil cooled machine can be more precise. This modeling procedure is described in Figure 2. Figure 2. Modeling procedure of thermal analysis of direct coil cooled machine 2.2 Modeling of machine with LPTN A direct coil cooled switched reluctance machine is proposed for the investigation. The machine has an 18/12 tooth combination and can deliver up to 70 kw power. The maximal speed is larger than 18,000 rpm. For modeling, the thermal behavior of the machine in the circumferential direction is assumed to be periodically symmetric. Thus in the cross section plane 1/36 of the stator, shown in Figure 3(a), and 1/24 of the rotor is considered in the thermal model. The stator and rotor are both divided into yoke and tooth. Due to the large thermal resistance of winding insulation, the coils are discretized into 6 segments. The oil flow has contact with winding segments and stator yoke. In the axial direction, the temperature rise of oil flow 3

along the machine is regarded, because the oil have relatively low thermal capacity compare to water. End-windings are modeled on both front ends of the motor. These end windings are completely submerged in oil, and modeled according to the thermal behavior described in Figure 3(b). With this configuration the temperature gradient caused by oil flow, see Figure 1, can be included. In the laminar channel flow with fluid guiding structure, the flow in the channel is reflected by the guiding structure and forming a 3-dimentional velocity field, which is presented in Figure 4(a). This effect prevents the thermal development along the channel and enhances heat transfer to wall periodically. Figure 4(b) present the wall temperature of a slot cooling channel with guiding structure. (a) (b) Figure 3. Section for thermal modeling: Half-tooth section of the stator (a); End-winding area (b) 2.3 CFD study of cooling channel In the direct coil cooled machine, the slot channels are formed by electric windings, and can have large aspect ratio in the cross section. The fluid guiding structure further increases heat transfer along the cooling channel periodically. These effects cannot be precisely represented by using classical Nusselt number correlations. A variety of Nusselt correlations can be used for solving heat transfer issues in laminar flow regime [7], most of the correlations can be written in the following form: Nu,, The oil flow in the machine slot is in the laminar flow regime and has thermal entrancing effect. A correlation considering the thermal entrancing effect was provided by Sieder & Tate [8]. Nu 1.86 / /. This equation is valid for flow in short channels, where the thermal entrancing effect is dominant. In the equation the basic influence factors, e.g. Reynolds number and Prandlt number on heat transfer are taken into account. The term D/L implies that the shorter the channel is, the larger the thermal entrancing effect can be. The effect of the term is limited due to the power, however, it represent the influence of temperature gradient in the fluid flow. The fluid near a heated wall has higher temperature and hence lower viscosity. (a) (b) Figure 4. Coolant flow in a slot channel with optimized fluid guiding structure: Velocity field (a); Temperature distribution of heated wall (b) Although the mechanism are different, the fluid guiding structure and the thermal entrancing region actually have both heat transfer enhancement effect, which can be captured by the factors described in the Sieder-Tate correlation. Thus the following equation form is proposed to represent the channel flow with fluid guiding structure. Nu Since the discussed slot channel has a constant D/L ratio, the D/L term is then taken out of the equation. In CFD analysis the flow rate v and inlet temperature T in are considered as input variables. The Nusselt number Nu, and all other variables e.g. Re, Pr, viscosities and can all be calculated. In the end, through regression analysis the parameters a, b, c in the equation can be evaluated. 4

After these parameters are solved, the new correlation can represent the heat transfer of stator slot channels and then be transferred into LPTN model for machine thermal study. The solver for the analysis is chosen based on Reynolds-averaged Navier-Stokes (RANS) governing equations. With the RANS equations the Reynolds stress term in Navier-Stokes equations is averaged, which resulted in a flow and heat transfer with suppressed fluctuation. Commercial CFD software ANSYS FLUENT is utilized for the calculation. The analysis setup is shown in Table 2. The fluid for the study is a special developed type of transmission oil. Table 2. Setup of the CFD analysis Boundary Definition Fluid TYPE-I Inlet Temperature -30 100 C Inlet Flow Speed 0.001 0.3 m/s Heat Flux on Wall 51 kw/m 2 Figure 5 plots the CFD calculated correlation between the Nu and Re, Pr,. The Re and Pr is combined and presented by the non dimensional Peclet number (Pe). The Peclet number have the major influence on Nusselt number, and the ratio further illustrate the temperature influence on the viscosity gradient. The viscosity of oil rises exponentially as the temperature decreases. At low inlet temperature the heat transfer reduces while the viscosity ratio between wall and bulk rises. thermal effect of fluid guiding structure cannot be captured by this standard correlation. Avg. temperature of target wall [ C] 300 250 200 150 100 50 0 0.00 5.00 10.00 15.00 CFD @ -20 C inlet CFD @ 80 C inlet Sieder Tate @ 80 C inlet LPTN @ 30 C inlet Flow rate [l/min] Figure 6. Comparison of wall temperature between classical Sieder-Tate and developed correlation 3 Experimental setup CFD @ 30 C inlet Sieder Tate @ 30 C inlet LPTN @ -20 C inlet LPTN @ 80 C inlet The prototype machine is equipped with both direct coil cooling structure and conventional water cooling jacket, shown in Figure 7, which can be activated separately. With this configuration, the influence from machine manufacturing can be excluded during the experimental comparison. Figure 5. Result of CFD analysis A comparison to standard Sieder-Tate correlation is plotted in Figure 6. The derived correlation agrees well with the CFD simulation for channel with fluid guiding structure. The standard Sieder- Tate correlation is calculated for a channel with the same hydraulic diameter and length. The wall temperature is overestimated, which implies the Figure 7. Cut view of prototype machine with both water jacket and direct coil cooling The comparison is conducted on a test bench, shown in Figure 8, under room temperature with 6 l/min flow rate. The machine is connected both with a water temperature control unit and an oil temperature control unit. 29 type-k thermal couples are mounted in the stator stack, slot winding area, end-winding, rotor etc. In the slot winding area, thermal couples are mounted on the middle section of the coils. Since the slot winding area can have large temperature gradient, thermal couples are mounted on 3 different coils to compensate possible error due to sensor positioning. To present temperature gradient along 5

the axial direction of the machine, thermal couples are mounted on both ends of the coil. Temperature [ C] 160 140 120 100 80 60 40 Figure 8. Prototype machine on test bench 4 Comparison with water cooled machine To exactly compare the cooling performance without influenced by high frequency uncertainties, e.g. eddy current due to skin effect and proximity, the prototype machine is applied with direct current. At the beginning of the experiment, one cooling circuit is chosen to be activated. And a constant voltage of 2 V is applied to all of the three phases of the machine to generate power losses. By applying losses to the coils, the temperature in the machine structure will rise to an equilibrium level, at which the temperature in the machine no longer changes. As soon as no significant temperature changes can be observed in the machine, the power supply is then shut down and another voltage of 2.4 V is applied to the coils. With this test configuration the temperature behavior in the machine can be compared. Also in the coils, the variation of electric resistance regarding temperature change can be documented. Figure 9 plots the temperature behavior of the machine with activated water jacket cooling. In the LPTN model, the boundary to oil is removed in this case and the heat transfer of water jacket is added to the model. The dashed lines are values from experiments, and solid lines are values from model simulation. The maximal temperature in coil swings into 120 C, when the coils are applied with 2 V, and approx. 150 C, when 2.4 V is applied. The average stator temperature stays low during the operation. Avg. stator temperature remains under 45 C. 20 0 500 1000 1500 Time [s] CoilMaxExpWat StatAvgExpWat CoilMaxSimWat CoilAvgSimWat CoilAvgExpWat Water CoilMinSimWat StatAvgSimWat Figure 9. Temperature behavior in water jacket cooled machine Figure 10 present the temperature behavior of the machine with activated direct coil cooling. The modeling approach with CFD, which is described in section 2, is deployed. The result from LPTN model agrees well with the values from experiment. The model slightly overestimates the temperatures in the machine for approx. 3 K, which is acceptable. The end-winding on the fluid inlet side have lower temperature than the end-winding on the fluid outlet side, approx. 10 K. In the machine with direct coil cooling, the temperature gradient is significantly lower. The maximal coil temperature is reduced by 90 K compare to water jacket cooling. Temperature [ C] 65 60 55 50 45 40 35 30 25 20 0 200 400 600 800 1000 Time [s] EndCoOutExp EndCoInExp SlotCoAvgExp StatAvgExp Oil EndCoOutSim EndCoInSim SlotCoAvgSim Figure 10. Temperature behavior in direct coil cooled machine This thermal difference also influences the electric resistance of the machine. Making the direct coil cooled machine more energy efficient. The phase current in the experiments are presented in Figure 11. The coil resistance is reduced by 18.5 % when the direct coil cooling is activated. 6

Phase current [A] 200 150 100 50 0 0 200 400 600 800 1000 1200 1400 1600 Time [s] IphaWat IphaOil Figure 11. Phase current behavior during measurement In the test the thermal resistance from machine hotspot to fluid is reduced by 74 % when the machine is cooled with direct coil cooling, although the applied losses are 20 % higher. When comparing at the same losses level, the direct coil cooling shows a reduction of more than 80 %. Table 3 compares the effectiveness of cooling as the machine is operating. When the coil cooling is activated, the rated torque output can be raised to the peak torque level. At the same time, water jacket cooling provides much lower output. Table 3. Rated torque output of the prototype machine Machine Speed [rpm] Coil Cooled, Conti. Torque [Nm] Water Jacket Cooled, Conti. Torque [Nm] 3000 110 29 6000 100 20 5 Conclusions In this paper, an advanced LPTN modeling approach with CFD analysis is presented. Particular focus is put onto the thermal boundary to coolant flow. This is especially important for estimating the thermal behavior of the direct coil cooled machine. The proposed correlation with CFD analysis is compared with standard Sieder- Tate correlation. The developed LPTN model is then used in the comparison with water jacket cooling. To exclude the influences from high frequency, direct current experiment is conducted on the prototype machine. The simulation results agree well with the experiments. Direct coil cooling reduces hotspot thermal resistance by 80 %. The continuous torque output can be raised to 300 %. Also, the thermal influence on the electric resistance is compared and discussed. Acknowledgments This activity is supported by the European Community Seventh Framework Programme, Optimized Electric Drivetrain by Integration (ODIN), website: http://www.fp7-odin.eu/, grant agreement no.: 314331. The authors would like to thank DLR, Robert Bosch GmbH, and Consortium of ODIN Project for all organizational and technical supports. References [1] M. Popescu; D. Staton; D. Dorrell; F. Marignetti; D. Hawkins, "Study of the thermal aspects in brushless permanent magnet machines performance," Electrical Machines Design Control and Diagnosis (WEMDCD), 2013 IEEE Workshop on, vol., no., pp.60,69, 11-12 March 2013. [2] Z.Y. Liu; T. Winter; M. Schier, "Direct coil cooling of a high performance switched reluctance machine (SRM) for EV/HEV applications", 2014, Manuscript submitted for publication. [3] P.H. Mellor; D. Roberts; D.R. Turner, "Lumped parameter thermal model for electrical machines of TEFC design," Electric Power Applications, IEE Proceedings B, vol.138, no.5, pp.205,218, Sep 1991. [4] A. Bejan, Convection Heat Transfer, 2nd ed., Wiley, New York, 2005. [5] D.A. Staton and A. Cavagnino, Convection heat transfer and flow calculation suitable for electric machines thermal models, IEEE Trans. Ind. Appl., vol. 55, no. 10, pp. 3509 3516, Oct. 2008. [6] J. R. Simonson, Engineering Heat Transfer, 2nd ed. Basingstoke, U.K.: Macmillan, 1988. [7] F.P. Incropera and D.P. DeWitt, Fundamentals of Heat and Mass Transfer. Hoboken, NJ: Wiley, 1990. [8] E.N. Sieder, G.E. Tate, Heat Transfer and Pressure Drop of Liquids in Tubes. Industrial. Engineering Chemistry, 28, 1429, 1936. [9] G. Dajaku and D. Gerling, An improved lumped parameter thermal model for electrical machines, in Proc. 17th ICEM, 2006, pp. 1 6. Authors Zhengyu Liu received his B.Sc. degree in 2009 from the Tongji University Shanghai, China, and the M.Sc. degree in 2012 from technical university Berlin, Germany. Currently, he is a PhD student, supported from Robert Bosch GmbH, in the Institute of Vehicle Concepts in German Aerospace Center (DLR). 7

Thomas Winter received his Dipl. Ing.(FH) from University of Applied Science Esslingen in 2000. From 2000 until now he works as a Development Engineer for the Robert Bosch GmbH. His current work includes the advanced development of electric drives for hybrid and electric vehicles. Dr. Michael Schier who heads the department of vehicle energy concepts at the German Aerospace Center (DLR), received his diploma and Dr degree in Electrical Engineering with specialisation in energy technologies and electrical drives at the Technical University of Kaiserslautern, Germany. 8