Vacuum Chambers. Type DK /DK /DK

Similar documents
Capacitive Pick-Up Type DB 040

Vacuum Pumps. Two general classes exist: Gas transfer physical removal of matter. Mechanical, diffusion, turbomolecular

Jumbo Cross Beam Ionizer

A 200 kev Electrostatic Accelerator

barmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8" Discharge: 8" Spherical solids handling: 3"

CF (Conflat Flange) Fittings - Adapters. (505)

Technical description of photoelectron spectrometer Escalab 250Xi

VACUUM PUMPING METHODS

Jlab FEL Photoemission DC Guns

UPGRADE AND COMMISSIONING OF THE PIAVE-ALPI ECR INJECTOR AT LNL

CapaciTorr HV 200 HIGHLIGHTS

CapaciTorr HV Pumps. making innovation happen,together

Flight Demonstration of Electrostatic Thruster Under Micro-Gravity

HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F

Design of structural components and radial-build for FFHR-d1

Connector~Tech Providing Harsh Environment Connector

HRN/HRN-C Series Hydraulic Vane Rotary Actuators

Vacuum System of Synchrotron radiation sources

Series 7500 Formed Metal Bellows Catalog 974C


Lecture 4. Ultrahigh Vacuum Science and Technology

Effect of Plasma Plume on CubeSat Structures as a Function of Thrust Vectoring

The NRC Lift/Transport system

Vacuum. Residual pressure can thwart the best cryogenic design. Each gas molecule collision carries ~kt from the hot exterior to the cold interior.

HiPace 300 with TC 110, DN 100 CF-F

Fall 2014 Mott Target Replacement and Ladder Position Re- Calibration JLAB- TN Joe Grames. September 17, 2014

POSITRON EMISSION ISOTOPE PRODUCTION CYCLOTRON AT DLNP JINR (STATUS REPORT)

Vacuum and mechanical design of ILC DR

user manual blotting Hoefer PR648 Slot blot manifold um PR648-IM/Rev.F0/08-12

Chemistry Instrumental Analysis Lecture 31. Chem 4631

HiPace 1200, with TC 1200, DN 200 CF-F

Installation, Maintenance and Operating Instructions

FVBSS fixed volume bottle

Hiden SIMS Secondary Ion Mass Spectrometers. Analysers for surface, elemental and molecular analysis

ø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke.

Ion Pump Applications

Steven C. DeCaluwe a,b, Paul A. Kienzle b, Pavan Bhargava b,c, Andrew M. Baker b,d, Joseph A. Dura b

TABLE OF CONTENT Scope 2 Alignment Systems and Procedures 2 Balancing 8 Lubrication System 10 Preservation of Spare Parts 12

CapaciTorr B MK5

SNMS. SNMS Applications. Combined SIMS and SNMS

flexible couplings for pipe repair

CLIPPER SCREEN SIZES - DECEMBER 28, 2005

ION Pumps for UHV Systems, Synchrotrons & Particle Accelerators. Mauro Audi, Academic, Government & Research Marketing Manager

ORTEC. SLP Series Silicon Lithium-Drifted Planar Low-Energy X Ray Detector Product Configuration Guide

PR CYCLONE SECONDARY SHUTOFF

Colliding and Moving Bose-Einstein Condensates: Studies of superfluidity and optical tweezers for condensate transport. Ananth P.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

API 11E - Specification for Pumping Units

HiPace 300 with TC 400, DN 100 CF-F

CRYOGENIC CONDUCTION COOLING TEST OF REMOVABLE PANEL MOCK-UP FOR ITER CRYOSTAT THERMAL SHIELD

Continued Work toward XHV for the Jefferson Lab Polarized Electron Source

A simple electric thruster based on ion charge exchange

Regular Reflectance and Transmittance Measurements of Transmissive Materials Using a STAR GEM Optical Accessory

PRODUCT & SERVICE LIST

Electron cloud experiments, and cures in RHIC

Commissioning the Front End Test Stand High Performance H - Ion Source at RAL

Previous Lecture. Electron beam lithoghraphy e - Electrons are generated in vacuum. Electron beams propagate in vacuum

Vacuum at the ESRF. current activities that benefit from simulation models

Ball screw. Linear. Coupling cover. 1Positioning table of a structure with enhanced sealing property. 3 High corrosion resistance

Development of Microwave Engine

Design, Installation and Commissioning of new Vacuum chamber for Analysing Magnet of K-130 Cyclotron

Ion Beam Sources for Neutral Beam Injectors: studies and design for components active cooling and caesium ovens

1 AT/P5-05. Institute of Applied Physics, National Academy of Sciences of Ukraine, Sumy, Ukraine

NEXTorr HV 100 HIGHLIGHTS

Investigation of anomalous heat production in Ni-H systems

ilearnalignment Alignment Training Subjects

TURBOPUMPS. For perfect vacuum solutions to challenging applications

Experimental Studies of Ion Beam Neutralization: Preliminary Results

Air Amplifers/Blowers

flexible couplings for pipe connections

Gurley Model A58 Absolute Encoder

Non-Interceptive Beam Monitor Prototype

TI 226H Calibration of Flow Check Devices using Positive Displacement Flow Meter

20-22 ISOTOPE RATIO MASS SPECTROMETER

FLSR - Frankfurt Low-Energy Storage Ring

Experimental Analysis of a Low-Power Helicon Thruster

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

Precision Ball Screw/Spline

Experimental High Energy Physics & Plasma Etching

THE INFLUENCE OF EXTERNAL MAGNETIC FIELD ON THE RADIATION EMITTED BY NEGATIVE GLOW OF A DC GLOW DISCHARGE

Pulse Height Analysis System (PHA) designed for W7-X Presented by Monika KUBKOWSKA

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

Safety Co-ordinator : Patrick Walden, TRIUMF, ext : 7340

Experimental investigation of the performance of a Parabolic Trough Collector (PTC) installed in Cyprus

REDUX WAVE SPRINGS. When Size Does Matter. Now with Metric Sizes. Europe s no 1 spring company

Ball Reverser. Ball Reverser Actuator. FLENNOR Power Transmission Products. Patented

Fiducials for BM1 Std. Vac. Chamber

ALIGNMENT OF THE SPARC LINEAR ACCELERATOR. M. Esposito, M. Paris, F. Sgamma, S. Tomassini, M. Troiani, (INFN LNF) Abstract

9. Pumps (compressors & turbines) Partly based on Chapter 10 of the De Nevers textbook.

Speed of Light in Air

A PHOTON-STOP FOR THE VLHC-2 ENGINEERING DESIGN PART 1

DEVELOPMENT OF A COMBUSTION SYSTEM FOR LIQUID OR GAS SAMPLES

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Index. Warman 13.5 / 1 CHH SuperSet Numbers Warman 3 / 2 DHH SuperSet Numbers Warman 4 / 3 EHH SuperSet Numbers Warman 6 / 4 FHH SuperSet Numbers

FOCAL X : A TEST FACILITY FOR X-RAY TELESCOPES

- A spark is passed through the Argon in the presence of the RF field of the coil to initiate the plasma

Beam Diagnostics for Mini Ion Engines

Fiducials for BM1 Std. Vac. Chamber

ERL09 WG1 DC-Gun KEK JAEA

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

Transcription:

Vacuum Chambers Type DK 020.010/DK 070.010/DK 050.010 Tel: (609) 924-3011 Fax (609) 924-3018 www.princetonscientific.com Email: info@princetonscientific.com

Vacuum Chambers Application: Vacuum chambers are used for installation of beam diagnostic devices, vacuum gauges, electrical feedthroughs, and pumping aggregates. Design of Vacuum Chamber: The distance between supporting flanges and beam axis should be uniform after optimization of various components, that must be attached. Universal elements such as compressed air actuated feedthroughs for example, can be designed with identical stroke and are subsequently exchangeable along the accelerator line. For the same reason, dimensions of supporting flanges should be uniform and should fit to a commercially available product. Considerations regarding parallelism of flanges, angular deviations, and accuracy of relevant dimensions should be constant overall in order to minimize manufacturing costs. It is of considerable advantage, in terms of maintenance and exchange of components, if all chambers are aligned correctly to the beam axis. Fig 1. Standard Diagnostic Chamber Model DK 020.010 with a length of 9.45. The chamber shown is supported on an 8 O.D. (CF- 150) pumping port. In this photo, four of five 6 O.D. (CF-100) flanges are visible. Flanges are provided for mounting of certain beam diagnostic elements. Also shown are one of the two 2 (CF-35) flanges. Cover Photograph: Vacuum Camber with UHV ports for an Emittance Measurement System.

Fig. 2 Vacuum Chamber Model DK 020.010 With beam diagnostic components (acrylic material has been used for demonstration purposes only) Technical Specifications Materials : Stainless steel Overall length : 9.45 ± 0.02 or 13.39 ± 0.02 NOTE: Distance between two planes with flanges (2 x 45 and 3 x 90 ) has been increased for the 13.39 inch version. Diameter of beam entrance/exit : 3.937 ± 0.004 Chamber diameter : 7.87 ± 0.002 Chamber height (incl. pumping port) : 16.93 ± 0.02 Number of flanges (for installation of beam diagnostics) : Five (5) Flange type : 6 O.D. ( CF-100 ) Flange orientations : Radial in two (2) planes: 1 = three (3) flanges (0, 90, 180 ); 2 = two (2) flanges (45, 135 ) Spacing between flanges and beam axis : 7.087 ± 0.004 Parallelism : 0.004 Angular accuracy vs. axis symmetry : 0.16 Number of flanges (for vacuum gauges and electrical feedthroughs) : Two (2) 2 O.D. ( CF-35 ) Orientation : 45 and 135 Spacing to beam axis : 5.90 ± 0.04

Technical Specifications (continued): Clearance between flanges/beam axis : 7.087 ± 0.004 Parallelism. 0.004 Angular accuracy vs. axis symmetry : 0.160 Number of flanges for vacuum gauges/ electrical feedthroughs : 2 ( CF-35 ) Orientation : 45 and 135 Clearance to beam axis : 5.90 ± 0.004 Pumping port : 1 x 8 O.D. ( CF-150 ) Clearance to beam axis : 9.84 ± 0.004 Sealing. : CF, Cu gaskets Leak rate (maximum) : Torrs x liters/second Surface treatment : Glass bead blasting (dry procedure). SLIT BOX Model DK 050.010 Technical Specifications: Material. : Stainless steel Overall length : 7.87 ± 0.02 Diameter of beam entrance/exit holes : 3.937 ± 0.004 Chamber diameter : 7.87 ± 0.02 Chamber height (incl. pumping port). : 16.93 ± 0.02 Number of flanges provided for slit system or diagnostics elements : Three (3) Type of flanges : 6 O.D. ( CF-100 ) Flange orientation : Radial in two (2) planes; Two (2) flanges at 0 and 180 and one (1) flange at 90. Displacement between both planes : 1.18 Clearance to beam axis. 7.087 ± 0.004 Parallelism. 0.004 inches Angular accuracy vs. axis symmetry : 0.16 Number of flanges provided for vacuum gauges/current feedthroughs : Two 2 ( CF-35 )

Technical Specifications (continued): Orientation : Radial at 45 and 135 Clearance to beam axis : 5.90 ± 0.04 Pumping port : One 8 O.D. ( CF-150 ) Clearance to beam axis : 9.84 ± 0.04 Leak rate (maximum) : 10-9 Torrs x liters/second Surface treatment : Glass bead blasting (dry procedure) Fig. 3 Slit Box as shown is provided for support of slit system applicable for UHV feedthroughs (DL series) EMITTANCE MEASUREMENT CHAMBER Model DK 070.010 Technical Specifications: Material : Stainless Steel Overall length : (18.50 ± 0.02) inches Diameter of the beam entrance- and exit holes : (3.937 ± 0.004) inches Diameter of the chamber : (9.8843 ± 0.02) inches

Technical Specifications (continued) Height of the chamber (including the pumping port) : (16.929 ± 0.02) inches Number of flanges provided for the installation of emittance measurement devices and beam diagnostics elements : 6 Orientation of flanges : radial in 2 planes 1. plane 3 x 8 O.D. ( CF-150 ) 2. plane 3 x 6 O.D. ( CF 100 ) Clearance between flanges and the beam axis : (7.087 ± 0.004) inches Parallelism : 0.004 inches Angular accuracy versus the symmetry axis : 0.16 Number of flanges provided for vacuum gauges or current feedthroughs : 2 O.D. ( CF- 35 ) Orientation : 45 and 135 Clearance to the beam axis : (5.90 ± 0.04) inches Pumping port : 1 x 8 O.D. ( CF-150 ) Clearance to the beam axis : (9.84 ± 0.84) inches Sealing : CF, Cu-gaskets Maximum leakrate : 10-9 Torr l/s Treatment of surface : Glass bead blasting (dry procedure) Fig. 4 Emittance Measurement Chamber with ports for two(2) emittance measurement Systems. High parallelism of main flanges is of extreme importance.