SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Similar documents
Routine MS Detection for USP Chromatographic Methods

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

An Automated Application Template for Dissolution Studies

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate Yu 3

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

Peptide Isolation Using the Prep 150 LC System

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

IN QUALITATIVE ANALYSIS,

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

USP Method Transfer and Routine Use Analysis of Irbesartan Tablets from HPLC to UPLC

Understanding Your Spectra Module. Agilent OpenLAB CDS ChemStation Edition

Automated and accurate component detection using reference mass spectra

MassHunter TOF/QTOF Users Meeting

UPLC Intact MASS Analysis Application Kit

Webinar: How to be More Successful with your ACQUITY QDa Detector Eric van Beelen

MassHunter Software Overview

Implementation of Methods Translation between Liquid Chromatography Instrumentation

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Varian Galaxie Chromatography Data System for Preparative HPLC

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

The Theory of HPLC. Quantitative and Qualitative HPLC

Stephen McDonald, Mark D. Wrona, Jeff Goshawk Waters Corporation, Milford, MA, USA INTRODUCTION

Stephen McDonald and Mark D. Wrona Waters Corporation, Milford, MA, USA INT RO DU C T ION. Batch-from-Structure Analysis WAT E R S SO LU T IONS

ImprovIng ADmE ScrEEnIng productivity In Drug DIScovEry

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

PosterREPRINT AN INTERACTIVE PHYSICOCHEMICAL PROPERTY PROFILING SOFTWARE FOR EARLY CANDIDATE ANALYSIS IN DRUG DISCOVERY INTRODUCTION

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

Analysis of Organic Light Emitting Diode Materials by UltraPerformance Convergence Chromatography Coupled with Mass Spectrometry (UPC 2 /MS)

MALDI-HDMS E : A Novel Data Independent Acquisition Method for the Enhanced Analysis of 2D-Gel Tryptic Peptide Digests

A Total Solution for Explosives Analysis by Reversed-Phase HPLC with a Parallel HPLC System

Expediting Achiral SFC Method Development Using a Multi-Channel SFC System with MS Detection

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

Agilent All Ions MS/MS

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

A Case of Pesticide Poisoning: The Use of a Broad-Scope Tof Screening Approach in Wildlife Protection

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

C HA R AC T E RIZ AT IO N O F INK J E T P RINT E R C A RT RIDG E INK S USING A CHEMOMETRIC APPROACH

Introduction. Chapter 1. Learning Objectives

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Use of High Speed/High Resolution Size-Based Chromatographic Separation of Polymeric Mixtures with Offline Infrared Detection

Finnigan LCQ Advantage MAX

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

ACD/Labs Software Impurity Resolution Management. Presented by Peter Russell

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Multi-residue analysis of pesticides by GC-HRMS

Multi-stage Mass Spectrometry up to MS 4 on a QTof System

Basic Principles for Purification Using Supercritical Fluid Chromatography

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Q-TOF PREMIER DYNAMIC RANGE ENHANCEMENT AND ACCURATE MASS MEASUREMENT PERFORMANCE

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

High Throughpu[ Separations and Structural Information Achieved with Automated LC/MS. Michael P. Balogh, Matthew J. Dilts Waters Chromatography

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

Performing Peptide Bioanalysis Using High Resolution Mass Spectrometry with Target Enhancement MRM Acquisition

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

Simplified workflows for the Thermo Scientific icap TQ ICP-MS

Improved Automated Sample Preparation for the Analysis of 25-OH-Vitamin D3 by LC/MS/MS

BIOLIGHT STUDIO IN ROUTINE UV/VIS SPECTROSCOPY

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

[ instrument specifications ]

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

Developing Analytical Chromatographic Methods for Pharmaceutical Stability Investigations

Multi-Channel SFC System for Fast Chiral Method Development and Optimization

for XPS surface analysis

DEMONSTRATING SUPERIOR LINEARITY: THE ACQUITY UPLC PHOTODIODE ARRAY DETECTOR

Automated PIONA Analysis by ASTM D8071 and VUV PIONA+

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Jane Cooper Waters Corporation, Wilmslow, UK APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEY WORDS

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Metabolic Phenotyping Using Atmospheric Pressure Gas Chromatography-MS

WALKUP LC/MS FOR PHARMACEUTICAL R&D

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative.

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Title Experiment 7: Gas Chromatography and Mass Spectrometry: Fuel Analysis

Validation of ACQUITY UPLC Methods

Guide to Peptide Quantitation. Agilent clinical research

ICP-MS. High Resolution ICP-MS.

Discover what you re missing

[application note] INTRODUCTION EXPERIMENTAL. Specimens. Extraction

[ a ppl ic at ion no t e ]

FUSION METHOD DEVELOPMENT SOFTWARE

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Transcription:

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW Paula Hong, John Van Antwerp, and Patricia McConville Waters Corporation, Milford, MA, USA Historically UV detection has been favored in many laboratories for its ease of use, robustness, and reliability. However, some of the inherent challenges include analytes that do not have a response in a UV channel, coelutions, and unknowns, any of which can require an orthogonal approach such as mass detection. While mass detection offers a number of benefits when used in tandem with UV detection, incorporating it into an existing UV workflow can be time-consuming and laborious. Advances in both instrumentation and software now make mass detection a technique that is much more accessible to chromatographers. In this white paper, we describe the features of the ACQUITY QDa Detector and Empower 3 Software that have been purposefully designed to enable analysts to readily incorporate mass detection within a UV chromatographic workflow.

INTRODUCTION A liquid chromatography (LC) system that includes an ultraviolet (UV) detector serves as the chromatographer s traditional method development tool. Incorporating mass detection capabilities enhances the analytical range and efficacy of such systems. Specifically, it provides the chromatographer with additional analytical capabilities, including the detection of analytes that give no UV response; identifying non-homogeneous or coeluting peaks; providing information to help identify a novel or unknown sample component; and tracking peaks. In the past, setting up and verifying the performance of quadrupole instruments before acquiring mass data required significant expertise. This process includes multiple steps such as calibration and tuning the detector for a specific analyte and chromatographic conditions. Consequently, for analysts new to mass spectrometry, such a process can present a significant challenge. In recent years, instrument developers have invested heavily in improving the reliability and ease of use of mass spectrometry hardware, and many of these improvements have lead to increased system stability and more robust equipment. Automation of the hardware and acquisition software has also been an area of focus. These technological advances have given rise to mass detectors that are as intuitive to operate as UV detectors, and capable of generating high-quality mass-spectral data. 1 This white paper will describe integrating one such mass detector, the ACQUITY QDa Detector, with chromatography data software (CDS), Empower 3 Software, into the UV chromatographic workflow. Automated startup Mass detection provides many benefits to UV liquid chromatographic separations, from providing an orthogonal mode of detection to streamlining method development. Yet mass spectrometers typically require a start-up procedure that is manual and can be time-consuming. For many instruments, part of that procedure involves operating a vacuum pump (or pumps) and establishing a flow of gas for many hours prior to operation of the instrument. In addition, before data acquisition can occur, calibration and resolution checks of the instrument should be performed, requiring the analyst to manually prepare samples and ensure enough calibrant for the process to complete. These procedures can require a significant amount of the analyst s time. With the ACQUITY QDa Detector, however, startup is fully automated. Operating the system from a cold start requires simply turning it on. The instrument s automated startup tests include a source pressure test, critical read-back checks, and calibration and resolution verification all occurring within minutes of startup. The calibration and resolution verification tests use an internal calibrant, which eliminates the need for separate sample preparation. If a calibration check is required, the analyst can select it from a drop-down menu. Once run, the calibration check automatically generates a report that evaluates the results and applies the new data as an updated calibration (Figure 1). Figure 1. An internal calibrant in the mass detector enables automated calibration and resolution. This automation eliminates the need for manual sample preparation and provides added confidence to an analyst who is new to mass spectrometry. 2

Empower 3 Software simplifies adding mass detection to a chromatography project. For example, analysts wishing to collect mass detection create the appropriate system in the software, and select the appropriate detection techniques in the project. Like photodiode-array (PDA) detection, mass detection is included in the software as a project option and is incorporated into the instrument method (Figure 2). Full Scan Selected Ion Recording (SIR) Figure 2. Empower 3 Software makes adding mass detection to any chromatographic project a straightforward operation. The switch-on capability in the CDS allows the chromatographer to select necessary workflows, processing capabilities, and detectors during project setup. These features can also be incorporated into existing project. Acquiring mass spectral data with minimal adjustments For MS quantification studies, optimizing the various MS detection parameters is often necessary. This process, which can include adjusting parameter settings that affect ionization, can prove time-consuming and challenging. If the parameters are not chosen carefully, the response of the analytes can be negatively affected. With the advancements in mass detection hardware and software, the ACQUITY QDa Detector requires adjustment of far fewer parameters. Defining an instrument method requires selecting a function (full-scan or selected ion recording (SIR)) and a mass range or value (Figure 3). The default settings provide quality data for a range of compounds. If adjustment is necessary, a few key parameter settings, each relating to a specific chromatographic property, are adjustable. For example, the probe temperature relates mostly to flow rate and mobile phase composition. The capillary voltage relates mostly to flow rate. The cone voltage is truly sample-specific, and the data rate is defined by chromatographicpeak width and the range of the MS data to be acquired. Figure 3. Defining a mass detector instrument method requires minimal input. The default parameters enable the analyst new to mass spectrometry to acquire quality data for a wide range of compounds. Figure 4 shows the separation of flavonoids analyzed in both UV and full-scan, positive-electrospray ionization mode. The mass spectral data confirming peak identity were collected using the default detector settings. 3

AU 0.050 0.025 403.1 373.1 403.1 343.0 433.1 373.1 UV 315 nm 0.000 Intensity 4x10 7 2x10 7 ACQUITY QDa Total Ion Chromatogram (TIC) 1.08 1.35 1.62 1.89 2.16 2.43 2.70 2.97 3.24 3.51 min Figure 4. The default mass detector parameters provide reliable mass spectra, which can provide information to help identify a novel or unknown sample component, and to perform peak tracking. For example, in the analysis of orange extract by UV and mass detection, mass data allows for confirmation of the presence of flavonoids. Comprehensive mass and UV spectral data review Historically, integrating mass-spectral data into the workflow of a chromatographer performing UV analysis has proven challenging. Both sets of data can contain individual chromatographic and spectral windows. Processing and reviewing the results of studies is, therefore, often cumbrous, requiring evaluation of UV and mass-spectral data individually. By providing a single window for reviewing mass and UV information simultaneously (Figure 5), Empower 3 Software simplifies data evaluation. The chromatographic display appearing in the lower portion of the window includes both the UV chromatogram and mass data a total-ion chromatogram (TIC) and in its bottom trace an extracted-ion chromatograms (XIC) for the separation. Automatically generated, the XIC is an overlay of the extracted-ion chromatograms corresponding to the apex base peak extracted from the TIC for each integrated UV peak (Figure 8). The spectral information for each peak appears in the upper portion of the screen. It shows the UV and mass spectra. To help identify possible coelutions, these spectra can be displayed as three separate views: 1) the base peak at apex (Figure 5); 2) a combined view that shows the apex and (average) combined spectra; and 3) a purity view, which displays the leading, apex, and trailing segments of a peak (figure 8). This combined view is assembled automatically according to specifications in the processing method. Figure 5. Empower 3 Software provides a view of mass and UV chromatograms and spectra. The UV chromatogram can be labeled with most intense ion at the peak apex. This view provides the tools for streamlined peak tracking and identification of coeluting peaks. 4

Summarizing results into a report Many chromatography data systems, including Empower 3, make use of a relational database to store, catalog, and retrieve data. The relational database provides data traceability required for compliance-ready management of MS data, and more efficient result reporting, as compared with flat-file chromatography and mass spectrometry data systems. These databases facilitate the use of configurable report templates. Once positioned in a report, objects such as tables, plots, chromatograms, spectra, etc. automatically receive data from the relational database during report generation. Quantitative studies may require thorough documentation, particularly while adhering to compliance regulations. Chromatography data software based on a relational database simplifies quantitative reporting because all necessary information can appear in the report template. Figure 7 illustrates this feature within Empower 3 Software, with a quantitative measurement of leucine enkephalin. A configurable report template receiving information directly from the database renders many types of data. Using a base template, the report displays text-based information (titles and tables) as well as chromatograms and spectra. Figure 6 demonstrates that simultaneously displayed UV and mass-based chromatograms can appear in the same configurable report using Empower 3 Software. Figure 7. The CDS system s relational database allows all the related information for the calibration report for leucine enkephalin to be displayed in a single report. Mass detector aids method development Chromatographic method development can be labor-intensive, requiring a significant investment in analysts time. Adding mass spectrometry to method development studies offers the opportunity to simplify and accelerate the method development process. Figure 6. A relational database CDS displays text, chromatograms and spectra in configurable report. The report displays UV and MS chromatographic and spectral results in a single plot. Analytical chemists have known a single detection technique provides insufficient information for missed peaks and coelutions. For those compounds that do not absorb UV, an orthogonal detection technique is required. To address some of these challenges, multiple detectors can be used for analysis of 5

a single sample, dependent on a different physical or chemical property of the molecule. Mass detection represents one such orthogonal detection mechanism since it requires that a gas-phase ion be generated. Figure 8 illustrates the advantage of orthogonal MS detection over UV-only detection. The LC/UV chromatogram shows the presence of four peaks in a chromatographic separation. To ensure peak purity, the UV and MS spectra of each peak can be examined. Analysis of the last peak shows no differences in the UV spectra across the peak, the expected pattern for a homogeneous peak. Yet when the mass spectra across the peak are similarly examined, the changes in distribution of the masses at m/z 256.9 and m/z 293.8 indicate the elution of at least two distinct analytes in that time range, which demonstrates that five, not four, chromatographically eluting analytes exist in this separation. Mass spectral data can help track the individual sample components as their relative elution times and order change during the process of separation development. 2 Figure 9 illustrates selectivity as a function of mobile phase ph during method development. LC/UV alone would require confirming the analyte retention times by comparing the analyte with authentic standards or, alternatively, by examining the UV spectrum for each analyte. The former task is time-consuming, and the latter can be difficult for closely related species. Using mass detection, however, the selectivity change is instantly noted by tracking the mass-to-charge ratio of the individual analytes. Moreover, this information can be displayed as the peak label in both UV and mass chromatograms. In addition, when using a CDS that is designed to process mass spectral data, such as Empower 3 FR3, added tools can assist in analysis of mass spectral data. For example, the MS Peak Tracking function can be used to monitor analytes in a series of chromatograms. This may be of particular usefulness when performing method development where each analyte s retention time may vary under different method conditions such as mobile phase ph, shown in Figure 10. Using the predominate mass-to-charge ratio of each peak, the CDS can automatically track analytes for all results. The added ability to summarize the results by user-defined text such as assigned mass, provides the ability to summarize the results in an easy to read table for evaluation or reporting of the results. 3 210.6 247.3 AU 0.7 0.6 0.5 0.4 0.3 306.7 370.8 410.6438.5 472.4 210.6 247.3 305.5 Peak #4-4.014 - QDa 1: MS Scan 293.8 256.9 293.8 210.6 247.3 Leading Apex Trailing 1 2 3 4 304.3 372.0 439.7456.6 256.9 293.8 PDA 254.0 nm (200-500)nm Figure 8. For the analysis of an API and related impurities, UV detection alone indicates the presence of four analytes by the number of chromatographically separated peaks. The addition of mass detection suggests the presence of two coeluting analytes present in peak 4. Analysis of the leading, apex, and trailing segments of the peak demonstrate varying ion ratios of the two major ions, thereby confirming the coelution. 0.2 0.1 0.0 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 4.0 4.1 4.2 4.3 4.4 4.5 min 6

0.50 ph 3 AU 0.25 286.1 300.2 196.0 342.1 316.1 202.0 224.1 258.0 AU 0.00 0.50 0.25 ph 4 196.0 202.0 286.1 182.1 300.2 342.1 316.1 224.1 258.1 Figure 10. Empower 3 report table for MS Peak Tracking with varying mobile phase ph. This report table was tailored to summarize and track retention times of the chromatograms in Figure 9, using a defined text string (Assigned Mass). 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 Minutes Figure 9. Mass detection provides a straightforward approach to tracking selectivity changes. For example, an API and related impurities was analyzed under different mobile phase ph conditions. Peak tracking, using the most intense ion at the peak apex, enables identification of selectivity differences without injecting standards individually for each set of chromatographic conditions. CONCLUSIONS Analytes that lack a UV-detectable chromophore require a means of orthogonal detection such as mass detection. Until recently, incorporating mass detection as part of the UV chromatographic workflow has required MS method development and instrument expertise. Also, reviewing chromatographic and spectral data for both detectors has traditionally meant viewing each set of data separately, making data evaluation burdensome. Utilizing an intuitive, automated mass detector, such as the ACQUITY QDa Detector, controlled by a compliant-ready data system like Empower 3 Software provides these benefits: Simple on/off capability of the mass detector, reducing startup time and enabling data acquisition within minutes. Using an intelligent CDS system, mass detection can be integrated as part of the workflow by selecting the appropriate instrument modules and detection capability from among the project properties. Automated startup and instrument checks provide greater confidence in results. Reviewing both chromatographic and spectral results from UV and mass detectors in a single window enables efficient, peak-by-peak data review. The ability of mass detection to identify coeluting peaks provides additional information. With the addition of an automated mass detector that has been designed to be a synergistic element of a chromatographic system, analytical chemists performing UV chromatographic separations now have the ability to significantly increase their method development capabilities without the complexity of a traditional mass spectrometer. References 1. Hong P, McConville PR. Combining Mass and UV Spectral Data with Empower 3 Software to Streamline Peak Tracking and Coelution Detection. Application Note 720004846EN, Waters Corporation, 2014. 2. Maziarz M, McCarthy SM, and Wrona M. Improving Effectiveness in Method Development by Using a Systematic Screening Protocol for a USP Method (Metocloproamide HCl and Related Substances). Application Note 720005026EN, Waters Corporation, 2014. 3. Maziarz, M. and Wrona M. Streamline Method Development with Empower 3 MS Peak Tracking. Technology Brief 720005721EN, Waters Corporation, 2016. Waters, The Science of What s Possible, ACQUITY, QDa, and Empower are registered trademarks of Waters Corporation. All other trademarks are the property of their respective owners. 2016 Waters Corporation. Produced in the U.S.A. August 2016 720005054EN LM-PDF Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 2000 F: 1 508 872 1990 www.waters.com