Member of the envea Group. Automatic Mercury Analyzer for the Laboratory

Similar documents
AULA 254 AULA Fluorescence

Mercury Stack Monitor SM-4

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

DMA-80L TECHNICAL SPECIFICATIONS

The. Family of Mercury Analyzers. Hydra II AA Atomic Absorption Detection Liquid Samples

110 Lowell Rd Hudson, NH USA Tel:

Product Descriptions and Offerings

Atomic Absorption Spectrometer ZEEnit P series

Basic Digestion Principles

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

Sodium Chloride - Analytical Standard

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Analysis of domestic sludge using the Agilent 4200 MP-AES

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct

JAPAN QUALITY. Automated Clinical Analyzer

JAPAN QUALITY. Automated Clinical Analyzer

UV3000. Accurate, precise, and portable ambient gas point analyzer

Automated determination of the uniformity of dosage in quinine sulfate tablets using a fiber optics autosampler

S2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF

Mercury Determination in Lichen, BCR-482, Using the QuickTrace M-7600 CVAAS Mercury Analyzer

Atomic Absorption Spectrophotometry. Presentation by, Mrs. Sangita J. Chandratre Department of Microbiology M. J. college, Jalgaon

EnAlgae SOP sheet: Silicate - SFA. 1. Purpose This procedure is to analyse seawater and freshwater for silicate, SiO2.

Fusion UV/Persulfate TOC Analyzer

Automated Clinical Analyzer

Advanced technics in the. (TIC/TOC/TNb)

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

novaa 800 D Atomic Absorption Spectrometer

USGS District Laboratory, Troy, NY Dissolved Inorganic Carbon Analysis Standard Operating Procedure

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Automating Wet Chemical Analysis

CLINICAL CHEMISTRY ANALYSER. The economical solution for all your needs GIVING YOU PEACE OF MIND

FerroZine Method 1 Method to 100 µg/l Fe (10-cm cell) Reagent Solution. Instrument Adapter Sample cell DR 6000 LZV

Agilent G2350A Atomic Emission Detector (AED)

Maintenance with OQ. ZEEnit 700. Operational Qualification OQ within the scope of a maintenance for the. Atomic Absorption Spectrometer

Protein Sequencer PPSQ-31A / 33A C297-E055B

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

CHEMISTRY WORKSTATION. The power of proven quality GIVING YOU PEACE OF MIND

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

PRINCIPLE OF ICP- AES

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

SMARTCHEM 300 STATE-OF-THE-ART DIRECT READ DISCRETE ANALYZER FOR AUTOMATED CHEMISTRIES

University Wet Chemistry Analyzer Packages

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Kjeltec 2300 Analyzer Unit

Fusion UV/Persulfate TOC Analyzer

SKALAR. your partner in chemistry automation. The San ++ continuous flow analyzer

Persulfate Digestion Method Method to 150 mg/l N (HR) Test N Tube Vials

Persulfate Digestion Method Method to 25.0 mg/l N (LR) Test N Tube Vials

DR/4000 PROCEDURE NITRATE. Using Powder Pillows

Ideal and powerful solution

Oxygen Demand, Chemical

USGS Troy WSC Laboratory Inductively Coupled Plasma- NH4Cl Soil Extracts SOP 425 Jordan Road Rev. No. 2.0 Troy, NY Date: 03/16/2012 Page 1 of 7

SMARTCHEM 140 DIRECT READ DISCRETE ANALYZER FOR SIMPLE AND AUTOMATED CHEMISTRIES

GTEK Laboratory Atomic Absorption Spectrometer AAS6000 Brochure

Speed and flexibility

SKALAR. your partner in chemistry automation. Formacs series Total Organic Carbon & Total Nitrogen Analyzers

Technical Procedure for Solid Phase Extraction of THC and THC-COOH for GC-MS Analysis

Manganese III Digestion Method * (with chloride removal)

The solution for all of your

Traceable UV-Vis Reference Materials

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

SKALAR. your partner in chemistry automation. Primacs SN Protein-Nitrogen Analyzer

Zinc Metal Determination Perkin Elmer Atomic Absorption Spectrometer AAnalyst Procedures

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy

Determination the elemental composition of soil samples

/TC TC WI. Date: /TC. Secretariat: Einführendes Element Haupt-Element Ergänzendes Element

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

ISEmax CAM40/CAS40. Technical Information

Total Organic Carbon, Total Nitrogen

Hydra-C Application Note: 1076

Automatic titrators, TitroMatic

SMARTCHEM 200 STATE-OF-THE-ART DIRECT READ DISCRETE ANALYZER FOR AUTOMATED CHEMISTRIES

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

Laboratory Measurements and Procedures

DR/4000 PROCEDURE MERCURY. Phase 1: Sample Digestion must be done in a fume hood! Toxic gases may be produced.

DYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS.

The Claviature of Gas Analysis

The Elzone II Particle Count and Size Analyzer

ISO INTERNATIONAL STANDARD. Water quality Determination of trace elements using atomic absorption spectrometry with graphite furnace

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

DRAFT EAST AFRICAN STANDARD

SMARTCHEM 140. DIRECt READ DISCREtE ANAlyZER FOR SIMPlE AND AUtOMAtED CHEMIStRIES

MEASUREMENT: PART II

Alcolyzer Plus. Beer Analyzing System. ::: Unique Density & Concentration Meters

LCTech GmbH Chromatographie

á233ñ ELEMENTAL IMPURITIES PROCEDURES

Atomic Absorption Spectroscopy

Phosphorus, Total. USEPA 1 PhosVer 3 with Acid Persulfate Digestion Method Method to 3.50 mg/l PO. Test preparation

A new chapter. medicacorp.com

Standard Operating Procedure for the Analysis of Dissolved Inorganic Carbon CCAL 21A.1

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

EXPERIMENT 23. Determination of the Formula of a Complex Ion INTRODUCTION

DR/4000 PROCEDURE. IRON, Total

425 Jordan Road SOP. No. 10 Rev. No. 1.3 Troy, NY Date: 03/14/2012 Page 1 of 7

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

ION CHROMATOGRAPHY SYSTEM S 150

high performance OPTIC 3 and applications a total analytical solution

Transcription:

Member of the envea Group AULA-254 Gold Automatic Mercury Analyzer for the Laboratory Fully automated flow analysis system High performance continuous flow analysis (CFA) technique Cold Vapor Atomic Absorption Spectrometry (CVAAS) Widest dynamic linear range Rugged construction Full feature software: AULAWIN Automatic protective system cleaning Integrated GoldTrap for maximum sensitivity of <1 ng/l Extension: Automated Sample Digester module (ASD) for aqueous samples

Applications The AULA-254 Gold is a fully automatic analysis system for determining trace mercury levels in water samples and digested samples. The AULA system is designed to be the right tool for researchers and scientists. The instrument automates routine analysis: it treats each sample exactly according to a pre-specified routine. This increases efficiency and productivity in your lab. Typical applications include: Environmental monitoring: Water, soils, sludge Analysis of foodstuffs: fish, innards, plants Medicine: urine, blood, saliva, hair Geochemistry, mining Petrochemistry Metallurgy and material testing Chemical industry: process monitoring, quality control Applicable to EPA Methods: 245.1, 245.7, 1631, 7470 and 7471A Reliable and proven method: continuous flow analysis (CFA) The system s working principle is the continuous flow analysis technique. The sample is continuously drawn from the sample vial and mixed with stannous chloride. This reduces mercury into the free atomic state. The solution then flows into a special crossflow reactor where an argon stream strips the elemental mercury and carries it into an optical cell, which is placed in the light path of a detector. The cell is entirely made of fused silica and is slightly heated to avoid water condensation. Optimized mercury detection technique The AULA-254 Gold uses an atomic absorption detector. The detection technique applied measures the resonance absorption at ambient temperature using a wavelength of 253.65 nm. This analytical method is commonly known as cold vapor atomic absorption spectrometry (CVAAS). Unlike typical multi-element AA systems, the AULA-254 is specially designed to detect and quantify mercury levels. This allows top performance in analytical applications. The AULA-254 Gold uses an electro-optical stabilized electrodeless mercury discharge lamp (EDL) in connection with solid state UV detectors, resulting in excellent baseline stability and detection limits far lower than those of other AA spectrometers.

GoldTrap preconcentration The integrated mercury preconcentration module (GoldTrap) drastically enhances detection sensitivity. Using ultra pure reagents and following the guidelines for mercury analysis at ultra trace levels, the AULA-254 Gold can achieve a measuring range from 1 ppt to 5000 ppt. Small thermal inertia is an outstanding property of our latest GoldTrap design, achieved through the use of a wafer-thin ceramic substrate. Heating and cooling rates are very fast. Analysis duration is comparable to the direct method. The GoldTrap is installed inside the photometer, thus not increasing bench space requirements. The AULAWIN software enables the user to decide whether the GoldTrap preconcentration is activated or bypassed. This makes the AULA-254 a most versatile instrument for almost any application. High productivity The typical duration of a full measurement cycle is 60... 180 seconds, depending on the set parameters. ers. Measuring calibration standards, samples and QC standards is fully automatic. No long purging or rinsing procedure is needed, even when samples with high concentrations are analyzed. The AULA-254 Gold is simple to use. Samples are decanted into glass vials and positioned on the autosampler carousel. No weighing of the samples required! Reagent solution (tin-(ii)-chloride) and rinse solution (water) are filled into the corresponding bottles. A keystroke starts the automatic measurement. The operator can suspend the automatic cycle at any time to select any sample for measurement ent or remeasurement. New samples can be added, even during a sample run. Minimized memory effects Mercury tends to cling to surfaces, causing a carry-over (memory effect) that can compromise results. AULA systems minimize memory effect by using selected materials for components touched by samples and by heating the optical bench. In addition, the autosampler probe and the sample tubing are rinsed after each sample run. Even samples with concentrations in the upper measuring range do not cause carry-over.

User safety The AULA-254 Gold collects mercury vapor in a sulfurized activated carbon filter, preventing mercury to escape into the working environment. A message appears on the screen when the filter needs replacement. A fume hood is not required Automatic baseline correction The stability of the baseline is checked prior to each measurement and the zero point is adjusted automatically. Typical zero drift during a measurement is below 0.0001 absorbance units. Thermoelectric dehumidifier Conventional mercury analyzers use desiccant-filled dryer tubes or permeation tubes for removing water vapor from the mercury-loaded carrier gas, and these tubes add a maintenance burden. The AULA-254 Gold uses a maintenancefree thermoelectric dehumidifier. The gas is cooled below the dew point, excess water condenses on the wall of a small glass tube and flows back into the reactor. Absolutely no liquid carry-over! In contrast to other dryers this device has an extremely small surface, which prevents mercury adsorption. Carrier gas flow stabilisation with electronic mass flow controller (MFC) The stability of the carrier gas flow has a direct effect on the reproducibility of measurements. For this reason the AULA-254 Gold system uses a highly precise (1.5 % accuracy) electronic mass flow controller (MFC). The system saves gas by automatically shutting off flow at the end of the job. Automatic purging after exceedance of mercury concentration The instrument automatically interrupts the measurement if samples with mercury concentrations exceeding the measuring range are detected. In this case the system will clean itself immediately by purging. After being diluted, the rest of the sample can be analyzed.

Full-feature software AULAWIN The AULAWIN software offers the complete feature set of modern analytical software. Developed with substantial input from our users, it is technically mature and easy to use. Samples, calibration standards and quality control standards (QCs) are selected by simple point-and-click. AULAWIN automatically creates a corresponding sample table, and the user can further specify sample dilution factors as well as sample weight and fill-up volumes for solid sample digestion. The software makes it easy to measure a sample repeatedly. The result of each measurement is calculated automatically from the chosen calibration function and displayed in µg/l or µg/kg. The QC function assures a high level of reliability. A toolbar allows fast access to frequently used functions. The absorbance signal graph can be viewed in real time and may also be recalled later. The analytical results are filed together with all data necessary for quality assurance (date, time, user ID, sample number, calibration data, method parameters, signal graph, etc). Worksheet templates can be created and stored to minimize set-up time for routine work. The user can format report sheets so that only the required data are printed. AULAWIN sample table and display of measuring signal AULAWIN calibration graph and turntable screen

Extension: Automated sample digestion (ASD) module Samples frequently contain mercury in a complex form and require sample treatment prior to measurement. Wet chemical sample digestion turns out to be superior to thermal sample decomposition when water-based sample material is analyzed. The AULA-254 Gold system is ready to be equipped with a sample preparation system for aqueous samples and digested samples. The ASD module carries out a digestion procedure derived from standard laboratory methods. The sample flow is continuously mixed with an oxidizing reagent (e.g. potassium permanganate, potassium dichromate). The sample/oxidant mixture is then heated to approx. 98 C in a reaction coil. As a result mercury is oxidised to Hg 2+ and the sample matrix is destroyed by oxidative reactions. After the oxidation step hydroxylamine hydrochloride and tin-(ii)-chloride are added to reduce the mercury to the elemental state which is then extracted by a stream of carrier gas (Argon or nitrogen). Water samples measured directly with the AULA-ASD module (8 ml of sample + 2 ml HNO 3 + 2 ml H 2 O 2 ) yield results that closely match the same water samples that were microwave digested. Automatic sample digestion is fast: cycle time for a complete analysis is less than 4 minutes. The AULA-ASD module is economical. Average reagent consumption for 100 analyses is: 3 g hydroxylamine-hydrochloride, 1-5 g potassium permanganate 6 g tin-(ii)-chloride, 5 l water (deionized) The AULA-ASD module is suited to any application where aqueous solutions require a sample treatment prior to analysis: surface water, ground water, seepage water, effluents, process water, etc. Cold Vapor Atomic Absorption Spectrometry: the ideal method for measuring mercury Cold vapor atomic absorption spectroscopy (CVAAS) is an extremely sensitive method to measure mercury and has been used successfully over a period of many years. The cold vapor atomic absorption technique is widely used for mercury trace analysis because of its simplicity, robustness, and relative freedom from interferences. Excellent detection limits can be achieved with our modern instruments.

Standards for the AULA-System The AULA-254 Gold system meets current regulations, with capacity in reserve to meet more stringent standards. Compliant with EPA Method 7470A (liquid waste), 7471A (solid or semisolid waste), 245.1 (drinking, surface, and saline waters, domestic and industrial wastes), 245.5 (soils, sediments, bottom deposits, and sludge type materials), 245.6, ASTM E538 (caustic soda and potash), FSIS USDA Food Safety and Inspection Service Method for Mercury Determination in Food, ISO 16772 (soil quality), ISO 6637 (fruit, vegetables and derived products), ISO 11212-2 (starch and derived products), The Ontario Hydro Method (stack gas), European Method EN 1483 (water quality), EN 12497, EPA Method 245.7 (water), 1631 (water), EN 13806. AULA-254 Gold: Technical specifications Measuring principle: UV source: Stabilization method: UV-Absorption (CVAAS), Wavelength = 253.7 nm Electrodeless low-pressure mercury lamp (EDL) Reference beam method Optical cell: Fused silica (Suprasil), heated, approx. 45 Measuring range: Detection limit: Carrier gas: Autosampler: 10 ng/l to 50 µg/l (GoldTrap deactivated) 1 ng/l to 5 µg/l (GoldTrap activated) < 50 pg Hg (GoldTrap deactivated) < 5 pg Hg (GoldTrap activated) argon (optional nitrogen), 4-6 l/h, stabilized with electronic mass flow controller 53 place random access, turntable type Sample vials: Sample consumption: Heating coil temperature: Zero drift: Measuring duration: Software: El. power supply: El. power consumption: 10 ml, glass, aluminium foil disc covers approx. 1 ml approx. 98 C (AULA-ASD only) none, Auto zero before each measurement typ. 60-180 seconds AULA-WIN, Windows compatible 115 VAC / 60 Hz 230 VAC / 50 Hz approx. 100 VA, (AULA 254-ASD: 120 VA) Dimensions: approx. 37 x 38x 44 cm (W x H x D) Bench space requirements: Weight: approx. 50 x 70 cm (W x D) (PC not included) approx. 14 kg (PC not included)

The Response to an Analytical Challenge: Mercury Instrumentsts Even nowadays quantitative trace analysis of mercury is still a challenging task for the analyst. Mercury Instruments is at all times striving to develop leading edge products for mercury analysis at the highest technical level. The range of applications for our mercury analyzers is unique world-wide. Mercury Instruments GmbH Analytical Technologies Liebigstrasse 5 85757 Karlsfeld / Germany mail@mercury-instruments.de Tel.: +49(0)8131-50 57 20 Fax.: +49(0)8131-50 57 22 2018 Mercury Instruments GmbH AULA-254 Gold Specifications may be subjet to change without notice Distributed by: As a leading supplier of high precision analytical equipment, we strive at all times to offer top quality solutions. Our products are manufactured according to the ISO 9001 quality regulations. www.mercury-instruments.de