LEP Faraday effect

Similar documents
Measurement of Verdet Constant in Diamagnetic Glass Using Faraday Effect

/15 Current balance / Force acting on a current-carrying conductor

Planck's "quantum of action" and external photoelectric effect (Item No.: P )

Physical Structure of Matter. Hall effect in p-germanium Solid-state Physics, Plasma Physics. What you need:

Magnetic field outside a straight conductor (Item No.: P )

Magnetic field of single coils / Biot-Savart's law

Coherence and width of spectral lines with Michelson interferometer

Fresnel s law, theory of reflection

Normal and anomalous Zeeman effect

β-spectroscopy Fig. 1: Experimental set-up for determining inductance from the resonant frequency of an oscillatory circuit.

Physical Structure of Matter /07 Zeeman effect/ normal and anomalous version. Physics of the Electron. What you need:

Physical Structure of Matter Hall effect in p-germanium with Cobra3. Solid-state Physics, Plasma Physics.

Atomic and nuclear physics

Physics 476LW. Advanced Physics Laboratory - Faraday Rotation

NAPREDNI FIZIČKI PRAKTIKUM II studij Geofizika POLARIZACIJA SVJETLOSTI

Physical Structure of Matter

KERR EFFECT. Monochromatic, vertically polarized light impinges on a PLZT element (leadlanthanum-zirconium-titanium

Physics 476LW Advanced Physics Laboratory The Faraday Effect

Optics. Measuring the line spectra of inert gases and metal vapors using a prism spectrometer. LD Physics Leaflets P

Magnetic field of single coils/ Biot-Savart s law with Cobra4

Dispersion and resolving power of the prism and grating spectroscope (Item No.: P )

Physics: Waves, Sound/Light, Electromagnetic Waves, Magnetism, Mains Electricity and the National Grid

Lab #13: Polarization

DISPERSION OF A GLASS PRISM

Physical structure of matter Band gap of germanium with Cobra3. Solid-state Physics, Plasma Physics. What you need:

LEP Hall effect in p-germanium with Cobra3

PLANNING EXPERIMENT (SECTION B)

Atomic and nuclear physics

GEOMETRICAL OPTICS Practical 1. Part II. OPTICAL SYSTEMS

DISPERSION VERY SHORT ANSWER QUESTIONS. Two identical prisms made of the same material placed with their based on opposite sides (of the

3B SCIENTIFIC PHYSICS

The Zeeman Effect refers to the splitting of spectral

Practical 1P4 Energy Levels and Band Gaps

LEP Coupled pendula

End correction = 0.2cm Actual length of object X = = 1.3cm. Constant gradient (straight line) = uniform acceleration. = 98 cm/s 100 cm/s

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Ordinary Level

PHYSICS 126, MESA COLLEGE Laboratory Manual

PHYSICS ORDINARY LEVEL

Never switch on the equipment without the assistants explicit authorization!

4. What is the speed (in cm s - 1 ) of the tip of the minute hand?

Characteristic curves of a solar cell

Practical 1P4 Energy Levels and Band Gaps

tip conducting surface


Investigating the Hall effect in silver

Answer all the questions in this section in the spaces provided.

ATOMIC PHYSICS BLACK-BODY RADIATION Practical 4 STUDY OF THERMAL RADIATION LAWS

Measurements in Optics for Civil Engineers

Mechanics Moment and angular momentum. Dynamics. What you need:

Objectives. Faraday Rotation. Introduction. component. polarizers are at 0 with respect to. reduced to

PHYSICS 5054/21. Published

Physics 116 Experiment 1. Introduction to Measurement and Error Analysis (PHY 115 and 117)

Moment of inertia and angular acceleration

GCSE PHYSICS. Materials For this paper you must have: a ruler a scientific calculator the Physics Equations Sheet (enclosed).

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Hall effect in germanium

Electricity. Measuring the force on current-carrying conductors in a homogeneous magnetic field. LEYBOLD Physics Leaflets P

Tuesday 24 May 2016 Morning Time allowed: 1 hour 30 minutes

Topic 4: Waves 4.3 Wave characteristics

Mechanics. Reversible pendulum Dynamics. What you need: Complete Equipment Set, Manual on CD-ROM included. What you can learn about

TRANSFORMERS B O O K P G

Core Concept. PowerPoint Lectures to accompany Physical Science, 8e. Chapter 7 Light. New Symbols for this Chapter 3/29/2011

Cambridge International Examinations Cambridge Ordinary Level

2. OPERATIONAL CONDITIONS

A) n 1 > n 2 > n 3 B) n 1 > n 3 > n 2 C) n 2 > n 1 > n 3 D) n 2 > n 3 > n 1 E) n 3 > n 1 > n 2

Forced oscillation - Pohl s pendulum with measure Dynamics. Equipment TEP

Book Page cgrahamphysics.com Transformers

YEAR 11- Physics Term 1 plan

Mechanics. Centrifugal force Dynamics. What you need: Complete Equipment Set, Manual on CD-ROM included. What you can learn about

Specimen Paper. Further Additional Science Unit 3 Physics 3 [CODE] Time allowed 60 minutes

ATOMIC PHYSICS PHOTOELECTRIC EFFECT Practical 2 DETERMINATION OF PLANCK S CONSTANT BY MEANS OF THE STOPPING POTENTIAL

Obtain an optical "bench" setup (there should be three sliding mounts on the calibrated horizontal bar. The setup is shown in the diagram below.

CBSE QUESTION PAPER. PHYSICS (Theory)

AP Waves/Optics ~ Learning Guide

Magnetic moment in the magnetic field (Item No.: P )

Physics by Discovery Standards (2nd Semester)

Introduction to Optics

Shadows (umbra and penumbra) (Item No.: P )

Photoelectric Effect Experiment

Introduction. Procedure. In this experiment, you'll use the interferometer to EQUIPMENT NEEDED: Lens 18mm FL. Component holder.

Thermochemistry/Calorimetry LEC Heat capacity of gases. What you need: What you can learn about. Principle and tasks

n(λ) = c/v(λ). Figure 1: Dispersion curves for some common optical glass types.

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Ordinary Level

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education

Rutherford experiment with MCA

Polarization of Light and Birefringence of Materials

X-ray absorption. 4. Prove that / = f(z 3.12 ) applies.

Critical parameters of

Measurement of basic constants: length, weight and time

EXPERIMENT 2-6. e/m OF THE ELECTRON GENERAL DISCUSSION

Refraction at the glass-air boundary (Item No.: P )

DEPARTMENT OF NATURAL SCIENCES. PHYS 1112, Exam 3 Section 1 Version 1 December 6, 2004 Total Weight: 100 points

= 115V. = = = C/m 2

Cambridge International Examinations Cambridge Ordinary Level

P5 Revision Questions

Cambridge International Examinations Cambridge Ordinary Level

[2] [2] Fig. 4.1

Final Worksheet. Equation And Constant Summary

Pearson Edexcel GCSE Physics/Science Unit P1: Universal Physics

An accessory to the polarizing microscope for the optical examination of crystals.

Transcription:

Related topics Electromagnetic field interaction, electron oscillation, electromagnetism, polarisation, Verdet s constant, Hall effect. Principle and task The angle of rotation of the polarisation-plane of plane polarized light through a flint glass rod is found to be a linear function of the product of the mean flux-densitiy and the length of the optical medium. The factor of proportionally, called Verdet s constant, is investigated as a function of the wavelength and the optical medium. Equipment Glass rod for 06496.00 1 Coil, 600 turns 06514.01 2 Pole pieces, drilled, 1 pair 06495.00 1 Iron core, U-shaped, laminated 06501.00 1 Housing for experiment lamp 08129.01 1 Halogen lamp, 12 V/50 W 08129.06 1 Holder G 6.35 f. 50/100 W halo.lamp 08129.04 1 Double condenser, f 60 mm 08137.00 1 Var.transformer, 25VAC/20VDC, 12A 13531.93 1 Voltmeter 5/15 V DC 07037.00 1 Commutator switch 06034.03 1 Teslameter, digital 13610.93 1 Hall probe, axial 13610.01 1 Lens, mounted, f +150 mm 08022.01 1 Lens holder 08012.00 1 Table top on rod, 18.5 11 cm 08060.00 1 Object holder, 5 5 cm 08041.00 1 Colour filter, 440 nm 08411.00 1 Colour filter, 505 nm 08413.00 1 Colour filter, 525 nm 08414.00 1 Colour filter, 580 nm 08415.00 1 Colour filter, 595 nm 08416.00 1 Polarizing filter with vernier 08611.00 2 Screen, translucent, 250 250 mm 08064.00 1 Optical profile-bench, l 1000 mm 08282.00 1 Base f. opt. profile-bench, adjust. 08284.00 2 Slide mount f. opt. pr.-bench, h 30 mm 08286.01 2 Slide mount f. opt. pr.-bench, h 80 mm 08286.02 5 Universal clamp 37715.00 1 Connecting cord, 750 mm, red 07362.01 3 Connecting cord, 750 mm, blue 07362.04 3 Problems 1. To determine the magnetic flux-density between the pole pieces using the axial Hall probe of the teslameter for different coil currents. The mean flux-density is calculated by numerical integration and the ratio maximum flux-density over mean flux-density established. 2. To measure the maximum flux-density as a function of the coil current and to establish the relationship between mean flux-density and coil current anticipating that the ratio found under 1. remains constant. 3. To determine the angle of rotation as a function of the mean flux-density using different colour filters. To calculate the corresponding Verdet s constant in each case. 4. To evaluate Verdet s constant as a function of the wavelength. Fig. 1: Experimental set-up for quantitative treatment of the. PHYWE series of publications Laboratory Experiments Physics PHYWE SYSTEME GMBH 37070 Göttingen, Germany 22601 1

Fig. 2: Condenser, ƒ = 6 cm Coloured glass Polariser Test specimen (flint glass SF6) Analyser Lens, ƒ = 15 cm Translucent screen. judgement about the complete extinction, it may eventually be better to remove the screen and to follow the adjustment of the analyser by eye-inspection. The maximum coils current under permanent use is 2 A. However, the current can be increased up to 4 A for a few minutes without risk of damage to the coils by overheating. Theory and evaluation When a transparent medium is permeated by an external magnetic field, the plane of polarisation of a plane-polarized light beam passing through the medium is rotated if the direction of the incident light is parallel to the lines of force of the magnetic field. This is called the. Set-up and procedure Set up the equipment as shown in Fig. 1 and 2. The 50 W experimental lamp is supplied by the 12 V AC constant voltage source. The DC output of the power supply is variable between 0 and 20 VDC and is connected via an amperemeter to the coils of the electromagnet which are in series. The electromagnet needed for the experiment is constructed from a laminaded U-shaped iron core, two 600-turn coils and the drilled pole pieces, the electromagnet then being arranged in a stable manner on the table on rod. In oder to demonstrate the experimentally, plane-polarized light is passed through a flint-glass SF6 cylinder, supported between the drilled pole pieces of an electromagnet. An analyser arranged beyond the glass cylinder has its polarisation plane crossed in relation to that of the polariser, so that the field of view of the face of the glass cylinder projected on the translucent screen appears dark. When current flows through the coils of the electromagnet, a magnetic field is produced, permeating the glass cylinder in the direction of irradiation. The rotation now occuring in the plane of oscillation of the light is indicated by resetting the analyser to maximum extinction of the translucent screen image. After reversing the polarity of the coil current, the experiment is repeated with the opposite magnetic field direction. After the flux-density distribution has been measured, the 30 mm long flint glass cylinder is inserted in the pole piece holes and the jack is raised so that the magnet is interpolated in the experimental set-up between the two polarisation filters. First of all, the experiment lamp 2, fitted with a condensor having a focal length of 6 cm, is fixed on the optical bench. This is followed by the diaphragm holder with coloured glass, two polarisation filters and a lens holder with a mounted lens of ƒ = 15 cm. The translucent screen is put in a slide mount at the end of the optical bench. The ray paths have been traced in Fig. 2. The planes of polarisation of the two polarisation filters are arranged in parallel. The experiment lamp is switched on and the incandescent lamp moved into the housing until the image of the lamp filament is in the objective lens plane. The electromagnet is then moved into the path of the image rays and is positioned so that the pole piece holes with the inserted glass cylinder are aligned with the optical axis. By sliding the objective lens along the optical bench, the face of the glass cylinder is sharply projected onto the translucent screen. Adjustment is completed by inserting the coloured glass in the diaphragm holder. The polarizing filter should permanently have a position of + 45. In this case the analyser will have a position of 45 ± for perfect extinction with being a function of the coil current, respectively of the mean flux-density. Regarding the Fig. 3: Flux-density distribution between the pole pieces for different coil currents. 2 22601 PHYWE series of publications Laboratory Experiments Physics PHYWE SYSTEME GMBH 37070 Göttingen, Germany

1. In the absence of the flint glass cylinder, the distribution of the magnetic flux-density is determined in the space between the pole pieces. Using the axial probe of the teslameter, which can easily be moved through one of the holes of the pole pieces when fixed in a universal clamp on a slide mount, the flux-density is measured anolg the whole gap in steps of 5 mm. The procedure is repeated for different current intensities. The results are shown in Fig. 3. The flux density increases strongly to the center of the gap and decreases to either side. Whatever the coil current may be, the ratio maximum flux-density over mean flux-density (found by numerical integration) is in each case approximately equal to 1.5. 2. Starting from the maximum flux-density in the gap we can now easily attribute a mean flux-density to the test specimen for any coil current given. The corresponding graph has been plotted in Fig. 4. For all further considerations it is anticipated that the test specimen is submítted to this mean flux-density. 3. If the polariser and analyser are crossed, the translucent screen image appears dark. It brightens up when the coil current is switched on and a longitudinal magnetic field is generated between the pole pieces. Adjustment of the analyser through a certain angle produces maximum extinction of the light (Position 1). If the direction of the magnetic field is reversed by changing the polarity of the coil current, the analyser must be adjusted in the opposite direction in order to darken the brightened field of view again (Position 2). The difference between position 2 and position 1 of the analyser is equal to 2. Fig. 5 to Fig. 9 show the angle 2 as a function of the mean flux-density for five different colour filters. It is observed that the plane of polarisation is rotated around the direction of propagation of the light which coincides with the direction of the magnetic flux-density vector. The angle of rotation becomes greater the higher the mean flux-density is. For a particular wavelength we find a linear relationship between the angle of rotation and the mean flux-density B. It can also be shown that the angle of rotation is proportional to the length l of the test specimen (Here: l = 30 mm) Hence: l B The proportionality factor V is called Verdet s constant. V is a function of the wavelength and the refractive index n ( ). = V( ) l B From the slopes of the graphs shown in Fig. 5 to Fig. 9 we find the following values for V( ): V( ) in degree V( ) in radians T m T m Colour filter = 440 nm 2857 49.8 Colour filter = 505 nm 1825 31.8 Colour filter = 525 nm 1647 28.7 Colour filter = 580 nm 1428 24.9 Colour filter = 595 nm 1210 21.1 The values shown in the table were calculated using the relation: V( ) = B l 4. Verdet s constant as a function of the wavelength can be represented by the following empirical expression*: V( ) = n 2 ( ) 1 A + B with: A = 10 7 [radians/t ], B = 10 19 [radians/t ] and 0 = 156.4 [nm] 2 2 0 Fig. 4 : Mean flux-density between the pole pieces as a function of the coil current. * Technical Information No. 17, Schott Company, Mainz, West Germany. PHYWE series of publications Laboratory Experiments Physics PHYWE SYSTEME GMBH 37070 Göttingen, Germany 22601 3

R Fig. 5: Angle of rotation of the polarisation-plane as a function of the mean flux-density for = 440 nm. Fig. 6: Angle of rotation of the polarisation-plane as a function of the mean flux-density for = 505 nm. 4 22601 PHYWE series of publications Laboratory Experiments Physics PHYWE SYSTEME GMBH 37070 Göttingen, Germany

Fig. 7: Angle of rotation of the polarisation-plane as a function of the mean flux-density for = 525 nm. Fig. 8: Angle of rotation of the polarisation-plane as a function of the mean flux-density for = 580 nm. PHYWE series of publications Laboratory Experiments Physics PHYWE SYSTEME GMBH 37070 Göttingen, Germany 22601 5

R Fig. 9: Angle of rotation of the polarisation-plane as a function of the mean flux-density for > 595 nm. as the mean wavelength for the UV resonances of flint glass SF6. A graphical representation of Verdet s constant as a function of the wavelength for flint glass SF6 is found in Fig. 10. The cross-points in Fig. 10 represent the measured values V(440 nm), V(505 nm), V(525 nm), V(580 nm) and V(595 nm). They coincide reasonably well with the values predicted by the above formula. Fig. 10: Verdet s constant as a function of the wavelength + measured values --- theoretical values. 6 22601 PHYWE series of publications Laboratory Experiments Physics PHYWE SYSTEME GMBH 37070 Göttingen, Germany