Dynamic Behavior of Three phase Inductions Motors as Loads in an Electric Power System with Distributed Generation, a Case of Study.

Similar documents
Power System Stability and Control. Dr. B. Kalyan Kumar, Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai, India

Control of Wind Turbine Generators. James Cale Guest Lecturer EE 566, Fall Semester 2014 Colorado State University

DEVELOPMENT OF DIRECT TORQUE CONTROL MODELWITH USING SVI FOR THREE PHASE INDUCTION MOTOR

Comparative Analysis of Speed Control of Induction Motor by DTC over Scalar Control Technique

From now, we ignore the superbar - with variables in per unit. ψ ψ. l ad ad ad ψ. ψ ψ ψ

Equivalent Circuits with Multiple Damper Windings (e.g. Round rotor Machines)

Parameter Estimation of Three Phase Squirrel Cage Induction Motor

ECEN 667 Power System Stability Lecture 18: Voltage Stability, Load Models

Introduction to Synchronous. Machines. Kevin Gaughan

Transient Analysis of Three Phase Squirrel Cage Induction Machine using Matlab

CHAPTER 5 SIMULATION AND TEST SETUP FOR FAULT ANALYSIS

Modeling Free Acceleration of a Salient Synchronous Machine Using Two-Axis Theory

ECE 585 Power System Stability

ECE 325 Electric Energy System Components 7- Synchronous Machines. Instructor: Kai Sun Fall 2015

Simulations and Control of Direct Driven Permanent Magnet Synchronous Generator

EFFECTS OF LOAD AND SPEED VARIATIONS IN A MODIFIED CLOSED LOOP V/F INDUCTION MOTOR DRIVE

An Introduction to Electrical Machines. P. Di Barba, University of Pavia, Italy

Mathematical Modelling of an 3 Phase Induction Motor Using MATLAB/Simulink

DIRECT TORQUE CONTROL OF PERMANENT MAGNET SYNCHRONOUS MOTOR USING TWO LEVEL INVERTER- SURVEY PAPER

AC Induction Motor Stator Resistance Estimation Algorithm

The synchronous machine (detailed model)

EE 742 Chapter 3: Power System in the Steady State. Y. Baghzouz

DESIGN AND MODELLING OF SENSORLESS VECTOR CONTROLLED INDUCTION MOTOR USING MODEL REFERENCE ADAPTIVE SYSTEMS

The synchronous machine (SM) in the power system (2) (Where does the electricity come from)?

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

SIMULATION OF STEADY-STATE PERFORMANCE OF THREE PHASE INDUCTION MOTOR BY MATLAB

Behaviour of synchronous machine during a short-circuit (a simple example of electromagnetic transients)

Mathematical Modelling of Permanent Magnet Synchronous Motor with Rotor Frame of Reference

Lecture 9: Space-Vector Models

COMPARISION BETWEEN TWO LEVEL AND THREE LEVEL INVERTER FOR DIRECT TORQUE CONTROL INDUCTION MOTOR DRIVE

Three phase induction motor using direct torque control by Matlab Simulink

International Journal of Advance Engineering and Research Development SIMULATION OF FIELD ORIENTED CONTROL OF PERMANENT MAGNET SYNCHRONOUS MOTOR

Model of Induction Machine to Transient Stability Programs

Three Types of Fuzzy Controllers Applied in High-Performance Electric Drives for Three-Phase Induction Motors

EE 6501 POWER SYSTEMS UNIT I INTRODUCTION

Generalized Theory of Electrical Machines- A Review

INDUCTION MOTOR MODEL AND PARAMETERS

Research on Permanent Magnet Linear Synchronous Motor Control System Simulation *

Robust sliding mode speed controller for hybrid SVPWM based direct torque control of induction motor

Nonlinear Electrical FEA Simulation of 1MW High Power. Synchronous Generator System

Dynamics of the synchronous machine

Dynamic Modeling of Surface Mounted Permanent Synchronous Motor for Servo motor application

Final Exam, Second Semester: 2015/2016 Electrical Engineering Department

DIRECT TORQUE CONTROL OF THREE PHASE INDUCTION MOTOR USING FUZZY LOGIC

Implementation of Twelve-Sector based Direct Torque Control for Induction motor

Wind Turbines under Power-Grid Partial Islanding

3 d Calculate the product of the motor constant and the pole flux KΦ in this operating point. 2 e Calculate the torque.

KINGS COLLEGE OF ENGINEERING Punalkulam

Use of the finite element method for parameter estimation of the circuit model of a high power synchronous generator

Generators. What its all about

Electric Machines I Three Phase Induction Motor. Dr. Firas Obeidat

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

DTC Based Induction Motor Speed Control Using 10-Sector Methodology For Torque Ripple Reduction

Unified Power System Analyses and Models using Equivalent Circuit Formulation

Synchronous machine with PM excitation Two-axis model

Lesson 17: Synchronous Machines

Doubly salient reluctance machine or, as it is also called, switched reluctance machine. [Pyrhönen et al 2008]

Sensorless Speed Control for PMSM Based On the DTC Method with Adaptive System R. Balachandar 1, S. Vinoth kumar 2, C. Vignesh 3

Direct Torque Control of Three Phase Induction Motor Using Fuzzy Logic

Independent Control of Speed and Torque in a Vector Controlled Induction Motor Drive using Predictive Current Controller and SVPWM

A Direct Torque Controlled Induction Motor with Variable Hysteresis Band

Dynamic d-q Model of Induction Motor Using Simulink

Steady State Modeling of Doubly Fed Induction Generator

Chapter 5 Three phase induction machine (1) Shengnan Li

MATLAB SIMULINK Based DQ Modeling and Dynamic Characteristics of Three Phase Self Excited Induction Generator

SPEED CONTROL OF PMSM BY USING DSVM -DTC TECHNIQUE

SCHOOL OF ELECTRICAL, MECHANICAL AND MECHATRONIC SYSTEMS. Transient Stability LECTURE NOTES SPRING SEMESTER, 2008

A Simplified State Model for Wind Turbines

Simulation of Direct Torque Control of Induction motor using Space Vector Modulation Methodology

Lecture 1: Induction Motor

The influence of the self-excited induction machine into the electrical grid under instability situation - Real case measurement

CHAPTER 3 ANALYSIS OF THREE PHASE AND SINGLE PHASE SELF-EXCITED INDUCTION GENERATORS

Gentle synchronization of two-speed synchronous motor with asynchronous starting

A Power System Dynamic Simulation Program Using MATLAB/ Simulink

Electromagnetic Torque From Event Report Data A Measure of Machine Performance

Chapter 3 AUTOMATIC VOLTAGE CONTROL

PERFORMANCE ANALYSIS OF DIRECT TORQUE CONTROL OF 3-PHASE INDUCTION MOTOR

Synchronous Machines

SHORT QUESTIONS AND ANSWERS. Year/ Semester/ Class : III/ V/ EEE Academic Year: Subject Code/ Name: EE6501/ Power System Analysis

INDUCTION MOTOR TORQUE DURING FAST BUS TRANSFERS

Massachusetts Institute of Technology Department of Electrical Engineering and Computer Science Electric Machines

EFFICIENCY OPTIMIZATION OF VECTOR-CONTROLLED INDUCTION MOTOR DRIVE

Modeling of Direct Torque Control (DTC) of BLDC Motor Drive

Modelling of Closed Loop Speed Control for Pmsm Drive

HOW TO DEAL WITH ELECTROMAGNETIC DISTURBANCES CAUSED BY NEW INVERTER TECHNOLOGIES CONNECTED TO PUBLIC NETWORK

Internal Model Control Approach to PI Tunning in Vector Control of Induction Motor

Fault Calculation Methods

SSC-JE EE POWER SYSTEMS: GENERATION, TRANSMISSION & DISTRIBUTION SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous)

Loss analysis of a 1 MW class HTS synchronous motor

Experimental and Finite Element Analysis of an Electronic Pole-Change Drive

EE2351 POWER SYSTEM OPERATION AND CONTROL UNIT I THE POWER SYSTEM AN OVERVIEW AND MODELLING PART A

Predicting, controlling and damping inter-area mode oscillations in Power Systems including Wind Parks

Permanent Magnet Synchronous Motors (PMSM). Parameters influence on the synchronization process of a PMSM

ELG4112. Electromechanical Systems and Mechatronics

Lecture 8: Sensorless Synchronous Motor Drives

Speed Sensor less Control and Estimation Based on Mars for Pmsm under Sudden Load Change

Fault Analysis Power System Representation

Decoupling control for aircraft brushless wound-rotor synchronous starter-generator in the starting mode

A STATIC AND DYNAMIC TECHNIQUE CONTINGENCY RANKING ANALYSIS IN VOLTAGE STABILITY ASSESSMENT

Transcription:

Dynamic Behavior of Three phase Inductions Motors as Loads in an Electric Power System with Distributed Generation, a Case of Study. Marcelo Rodrigo García Saquicela, Ernesto Ruppert Filho, José Luis Azcue Puma. School of Electrical and Computer Engineering, State University of Campinas (UNICAMP), Campinas, SP, Brazil Email:{Ernesto Ruppert Filho} ruppert@fee.unicamp.br {José Luis Azcue Puma} jose.azcue@ufabc.edu.br Abstract- One of the basics characteristics of a power electric system is guarantee the power supply to the loads reliable and uninterrupted, the modern power systems have minimal conditions for proper operation, one of studies of major concern is stability. The studies most considering the electric power system as a whole, taking into account elements that affect their behavior, mainly including the dynamic model of the loads. Within industrial environments loads are formed by three phase induction motors, these loads must be modeled dynamically in detail to be possible a faithful study of the system and its real influence into the power system. Will be made dynamic tests into am industrial electric power system selected to verify the influence of induction motor loads, the motors also are controlled with DTC technique and the system can operate with internal generation. I. INTRODUCTION Most of analyses of electric power systems are made with statics methods like P-V curves, the dynamic of the loads doesn t are taken in count. According [] the margins reductions of active power into P-V curves when the portion of loads composed by induction motors increases is because this type of loads have voltage dependence with the consumption of reactive power that are the typical behavior of this kind of loads. This is the reason why some researches talk about that systems composes with induction motors loads may represent a problem in terms of stability, if a disturb occur like short circuit of a loss of grid, this kind of loads may leave to the system to an unappropriated behavior []. The dynamic simulation of the nonlinear behavior of an electric system provides a reproduction more accurate of the phenomenon that occurs on a power grid. Meanwhile this analysis involves high computational cost, and don t show information about stability margins of the system. Its application is restricted to studies of coordination of control and protection devices, in specific situation of voltage collapse. [3]. For this reason, this work shows the dynamic simulation of a facility power electric system with three phase s induction motors as main loads, to look out the influence with and without control of the electromagnetic torque and activate internal power generation, as a case of distributed generation. The power grid under analysis belongs to a mining factory and the large induction motors correspond to stone crushers. II. SYSTEM MODEL A. Description of the industrial electric power system The industrial unit is formed for a substation, transformers, breakers, constant impedance loads, synchronous machines, electric power lines, three phase induction motors and its respective controls, based on [4]. The facility referred is located in São Paulo Brazil, rearranged for the study purpose like a mining factory with four three phase induction motors operating as stone crushers, the industrial grid have three salient poles synchronous machines, each one of 6.5 MVA, the induction machines are 5 hp squirrel cage. The substation has a short circuit level of 3 MVA, delivering a voltage of 38 kv, the power system is composed for loads modeled like constant impedance and the induction motors, the operation of the synchronous generators can be consider a case of distributed generation. Fig. illustrates a power grid under study. https://doi.org/.484/repqj3.84 3 RE&PQJ, Vol., No.3, April 5

Swing Bus 38kV 3MVA ψ r = L r i r + L m i s (.4) TR- 38-.5kV TR-9.5-4.6kV Load,7MVA Fp =,9 GS3 65 KVA 46 V Fp=.85 Load,5MVA Fp =,9 TR-8.5-4.6kV TR- 38-.5kV GS 65 KVA 46 V Fp=.85 Load 3 6,65MVA Fp =,9 TR-7.5-4.6kV GS 65 KVA 46 V Fp =.85 TR-3 4MVA 38-.5kV Load 4 Load 5,75MVA,3MVA Fp =,9 Fp =,9 TR-5 MVA.5-.3kV TR-4 4MVA 38-.5kV TR-6 MVA.5-.3kV T.I.M. T.I.M. T.I.M. T.I.M. Motor 5 hp Fp =.9 Motor 5 hp Fp =.9 Motor 3 5 hp Fp =.9 Fig.. Diagram of the industrial electrical power system B. Dynamic model of three phase induction motor The dynamic behavior of the three phase induction motor (T.I.M.) is governed by a set of differentials equations that can be placed in space vector form [5]. These equations show the relationship between linkages fluxes with estator and rotor windings with electrical currents and voltages of these windings. The differentials equations of estator and rotor voltages, can be represented on the stationary reference frame, system used in the simulations, are shown below (.) to (.4), using the definition of the voltage space vector, the current space vector and the magnetic flux space vector with the stator and rotor windings. the letter s is used for the stator variables and the letter r is used for the rotor variables. u s = R s i s + dψ s dt (.) u r = R r i r + dψ r jω r ψ r (.) dt ψ s = L s i s + L m i r (.3) Motor 4 5 hp Fp =.9 The compact form of these equations makes their application extremely convenient. The first terms of the equations (.) and (.) represents the voltage drops into the electrical resistances of the stator and rotor windings respectively. The second term represents the electromotive force of transformation of each winding, which are the first derived of the spatial vectors of the linkage magnetic fluxes with the stator and rotor. Finally the term jω r ψ r, represent the rotational electromotive force on the rotor produced by its rotation within the rotating magnetic field made by the stator currents. The equations (.) to (.4) are written in the form of spatial vectors of the linkage magnetic fluxes with the stator and rotor respectively. The spatial vectors of the currents, linkages fluxes and voltages of stator winding into the stationary reference frame are represented by: i s = 3 [i as(t) + i bs (t) a + i cs (t) a ] = i ds + ji qs (.5) ψ s = 3 [ψ as(t) + ψ s B(t) a + ψ s C(t) a ] = ψ ds + jψ qs u s = 3 [u as(t) + u bs (t) a + u cs (t) a ] = (.6) u ds + ju qs (.7) C. Control of three-phase induction motor For controlling of large induction motors was adopted the strategy based on direct torque control (DTC) using space vector modulation [6]. This control strategy uses the orientation of magnetic field by the stator flux for independent control of electromagnetic torque. According [7], can be use a two level inverter for controlling a motor of large scale (until 46 V) and it was implemented in this work. Others control strategies, like Direct Self Control can also be used. https://doi.org/.484/repqj3.84 4 RE&PQJ, Vol., No.3, April 5

D. Direct torque control of three-phase induction machine The purpose in the direct torque control is manipulate directly the stator flux linkage vector and the electromagnetic torque by the appropriated selection of the switching activation vectors of the feeding three-phase induction motor. The vectors selections are made restricting errors of the electromagnetic torque and the stator flux within two PI controllers, to achieve a quick answer of the electromagnetic torque, an acceptable switching frequency and low harmonic losses. DTC allows a quick response of the electromagnetic torque. In the symmetric three phase induction motor, one of the forms of representation of electromagnetic torque is through vector product between the spatial flux vector of flux linkage and stator current vector. T em = 3 Pψ s x i s (.8) Wherein ψ s and i s are the spatial vectors of the flux linkage and stator current respectively, P is the number of pole pairs. Into (.8) both vectors are represented into the stationary reference frame. We have to consider ψ s = ψ s e jρ s and i s = i s e jα s, where ρ s and α s are the angles of the spatial vectors of the flux linkage and stator current in relationship with the real axe of the reference frame system, then from the equation, it follows that: T em = 3 P ψ s i s sin(α s ρ s ) = 3 P ψ s i s sin ( α ) (.9) Wherein α = α s ρ s is the angle between the spatial vectors of flux linkage and the stator current. If an adequate voltage must be applied into the stator in such a way to keep the stator flux constant and the same could get a quick change in the angle ρ s, then the electromagnetic torque will vary rapidly. If the angle increase, will produce a positive electromagnetic torque, but, if the angel decrease, will produce a reduction of the electromagnetic torque. In conclusion, to control the spatial vector of the stator flux (module and angle) is necessary to generate an appropriate voltage vector through the inverter that feeds the three-phase induction motor. III. SIMULATION AND RESULTS Several teste were made, divided into scenarios, feeding the system with only the substation power supply, with and without electronic converters activating the induction machines, and feeding the system with the power of the substation and the synchronous generators. A. First scenario In this first group of tests, the conditions are that the industrial electric system is supplied only by the substation connection, without intervention of the synchronous generators. Two cases are compared, the first one without direct torque control of the four three-phase induction motors, and the other one with direct torque control of the inductive machines. We noted that currents in the substation are different in case one and in case two, as shown; current (A) (p.u.) 5 4 3 - - -3-4 -5.5.5.5 3 3.5 4 Fig.. Current delivered by the substation without DTC control of induction machines. current (A) (pu) 5-5.5.5.5 3 3.5 4 Fig. 3. Current delivered by the substation with DTC control of induction machines. https://doi.org/.484/repqj3.84 5 RE&PQJ, Vol., No.3, April 5

.5.5 -.5 -.5 We divided the industry power system into two blocks of inductive loads, each block formed by two inductive motors, each motor of 5 hp, 3 V and.78 MVA. As we can see in figure and figure 3, these two blocks of motors are activated in different times, t= second and t= seconds, the given current in the first case is about 533.4 A (pu) and in the second case is about 35.4 A (pu). In the first case, the electromagnetic torque of the machines is not controlled, like we see in the next figure. x 4 - -.5.5.5 3 3.5 4 reactive power (MVAr) (pu) B. Second Scenario In this second scenario the industry is supplied by the distributed generators and the power of the substation, it was verified that in all buses the voltage increase about 3%, because the system has more energy reserves, thanks to the synchronous generators of salient poles. The reactive power consumed in the system without DTC control is bigger than the system with DTC control of the three phase motors. 6 x 6 4 8 6 4 -.5.5.5 3 3.5 4 Fig. 4. Electromagnetic torque without control Fig. 6. Reactive power in induction machines without DTC control. 3.5 x 4 3.5.5.5 -.5.5.5.5 3 3.5 4 reactive power (MVAr) (pu).5 x 7.5.5 -.5 - -.5 - -.5.5.5.5 3 3.5 4 4.5 5 Fig. 5. Electromagnetic torque with control. As we can see in the figure 5, the generated electromagnetic torque (blue) follows very well the reference torque (green), in general with the DTC control takes about one second to stabilize the torque of the induction machine, without DCT, it takes about two seconds. Fig. 7. Reactive power in induction machines with DTC control. The electromagnetic torque of figure 8 without control, takes about. seconds to stabilize https://doi.org/.484/repqj3.84 6 RE&PQJ, Vol., No.3, April 5

.5 x 4.5.5 -.5 - -.5 -.5.5.5 3 3.5 4 Fig. 8. Electromagnetic torque In the other hand, with the control of torque, the machine takes about.65 seconds to stabilize the electromagnetic torque. REFERENCES [] L. P. da Silva, V. da Costa, Voltage stability including detailed induction motor models IEEE Trans. On industry application, Jun.. [] L. Peng, Study on the voltage stability of induction motor load, IEEE PES, Power System conference and exposition, 4. [3] Kundur, Power System Stability and Control,3th edition. McGraw-Hill Education, 994. [4] F. C. Lima Trindade, Analysis of Protection Systems and Control Industrial facilities with Synchronous Generators During islanded operation UNICAMP, February 9. [5] P. C. Krause, Analysis of Electric Machinery and Drive Systems, IEEE press. [6] T. G. Habetler, F. Profumo, Direct torque control of induction machines using space vector modulation, IEEE Trans, vol. 8, No. 5, October 99. [7] B. Wu, High Power Converters and AC Drives, IEEE press, 6.. 4 x 4 3 - - -3.5.5.5 3 3.5 4 4.5 5 Fig. 9. Controlled electromagnetic torque. IV. CONCLUSIONS When the system was simulated with the direct torque control (DTC), the reactive power consumed by the induction motors decrease, but the active power increase. The system present more stability when operates with the DTC control over the machinery and the distributed generators. The electromagnetic torque shows a quick response with the control applied as expected, in some applications like mine industry it is recommended for an optimal performance of the process. https://doi.org/.484/repqj3.84 7 RE&PQJ, Vol., No.3, April 5