Chem 454 instrumental Analysis Exam 1 February 6 th, 2008

Similar documents
Spectroscopy Problem Set February 22, 2018

Exam 1 Chem 454 February 9, total points

1. Cyclic voltammetry involves the measurement of a diffusion controlled at an electrode in which the is controlled. (4 points)

Instrumental Analysis

Exam 3 Chem 454 April 25, 2018, Name

2] The plate height in chromatography is best described as 2

3) In CE separation is based on what two properties of the solutes? (3 pts)

Chem 434 -Instrumental Analysis Hour Exam 1

Ch 313 FINAL EXAM OUTLINE Spring 2010

HPLC. High Performance Liquid Chromatography (HPLC) Harris Chapter 25

Fall 2012 Due In Class Friday, Oct. 19. Complete the following on separate paper. Show your work and clearly identify your answers.

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

Chemistry 112 Name Exam III Form A Section April 2,

Chem 321 Name Answer Key D. Miller

CHEM 10123/10125, Exam 3

HPLC Background Chem 250 F 2008 Page 1 of 24

Chemistry 325 Instrumental Methods of Analysis March 13, Final Exam. Name

CHEM 429 / 529 Chemical Separation Techniques

2014 학년도 1 학기 분석화학실험. 담당교수 : 이원용 ( 연구실 : 과 443-C, 전화 : , 전자우편 : 분광분석 / / 분리분석 / 전기분석화학

Analytical Topics to Consider in preparation for the MFAT/GRE

Introduction to Chromatographic Separations

Luminescence Spectroscopy Excitation is very rapid (10-15 s). Vibrational relaxation is a non-radiational process. It involves vibrational levels of

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

Chemistry 524--Final Exam--Keiderling Dec. 12, pm SES

CHEM J-14 June 2014

Questions on Instrumental Methods of Analysis

Chemistry 112 Name Exam III Form A Section November 13,

Gas Chromatography. Chromatography Laboratory Course. Dr. Christian Jungnickel Chromatography Course GC September 2005

CHEM 221 Instrumental Analysis FINAL EXAM May 10, 2016

Name: Regents Chemistry Date:

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

25. A typical galvanic cell diagram is:

CHEM J-8 June /01(a)

Chem 310, Fall 2005 Final Exam December 15, :15-12:15 (You must stop working at 12:15!)

CHEM 221 Instrumental Analysis FINAL EXAM May 10, 2016

Chapter 15 Molecular Luminescence Spectrometry

Luminescence transitions. Fluorescence spectroscopy

Chapter 7 Electrochemistry

Introduction to Pharmaceutical Chemical Analysis

GAS CHROMATOGRAPHY. Mobile phase is a gas! Stationary phase could be anything but a gas

Chapter 31 Gas Chromatography. Carrier Gas System

CHEMISTRY 102 FALL 2010 FINAL EXAM FORM C Section 502 DR. KEENEY-KENNICUTT PART 1

ELECTROCHEMISTRY OXIDATION-REDUCTION

ANALYSIS OF LEAD IN SEAWATER

CHMC 16 Instrumental Analysis (Syllabus)

Chromatographic Analysis

Complete the following. Clearly mark your answers. YOU MUST SHOW YOUR WORK TO RECEIVE CREDIT.

CHEMISTRY 13 Electrochemistry Supplementary Problems

Ch 11 Practice Problems

Chem 4501 Introduction to Thermodynamics, 3 Credits Kinetics, and Statistical Mechanics. Fall Semester Homework Problem Set Number 12 Solutions

2. a) R N and L N so R L or L R 2.

Electrochemical Cells

Analytical Chemistry

CHEM J-12 June 2013

Electrochemical Cells

Gas chromatography. Advantages of GC. Disadvantages of GC

CHEMISTRY 123 FALL 2010 Midterm #2

2401 Gas (liquid) Chromatography

COURSE DELIVERY PLAN - THEORY Page 1 of 6

Chromatographic Separation

Topic 8. Chromatography

Chemistry 30 Review Test 3 Redox and Electrochemistry /55

Instrumental Chemical Analysis

2. Balance the following reaction. How many electrons would be transferred?

Oxidation-Reduction Review. Electrochemistry. Oxidation-Reduction Reactions. Oxidation-Reduction Reactions. Sample Problem.

CHEMISTRY - CLUTCH CH.18 - ELECTROCHEMISTRY.

Topics in the November 2014 Exam Paper for CHEM1101

Oxidation refers to any process in which the oxidation number of an atom becomes more positive

BCIT Winter Chem Final Exam

Lecture 27 Chapter 19, Sections 3-4 Galvanic Cells Electrochemical Potential

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Chromatography and other Separation Methods

Chapter 19: Oxidation - Reduction Reactions

Remember - Ions are more soluble in water than in organic solvents. - Neutrals are more soluble in organic solvents than in water.

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Chapter 19: Electrochemistry

Reflection = EM strikes a boundary between two media differing in η and bounces back

School of Chemistry UNIVERSITY OF KWAZULU-NATAL, WESTVILLE CAMPUS JUNE 2009 EXAMINATION CHEM340: INSTRUMENTAL ANALYSIS.

CH 223 Sample Exam Exam II Name: Lab Section:

Molecular Luminescence Spectroscopy

Chemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES

Separation Sciences. 1. Introduction: Fundamentals of Distribution Equilibrium. 2. Gas Chromatography (Chapter 2 & 3)

Ultraviolet-Visible Spectroscopy

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

GAS CHROMATOGRAPHY (GC)

CHEM 3590 Final examination 2017 Instructor : Dr. Hélène Perreault Monday December 11, 1:30-4:30 pm, Frank Kennedy Gold Gym seats

ii) Describe the various types of detectors used in IR spectroscopy.

General Chemistry Exam 3 Chem 211 Section 03, Spring 2017

CHEMISTRY 102 EXAM 4 FORM 4D

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

High Pressure/Performance Liquid Chromatography (HPLC)

Part One: Introduction. a. Chemical reactions produced by electric current. (electrolysis)

a. Orange b. Green c. Red d. Yellow e. Colorless, because the crystal field splitting is so large that the absorption is shifted into the ultraviolet

Spiro-Configured Bifluorenes: Highly Efficient Emitter for UV Organic Light-Emitting Device and Host Material for Red Electrophosphorescence

ph = pk a + log 10{[base]/[acid]}

Chem 401 Unit 3 Exam F18 (Buffers, Titrations, Ksp, Transition Metals & Electrochemistry)

Exam3Fall2009thermoelectro

Fourier Transform Infrared Spectrometry Prelab Last modified: June 17, 2014

Chemistry 102 Chapter 19 OXIDATION-REDUCTION REACTIONS

Chem 75 Winter, 2017 Practice Exam 3

Transcription:

Chem 454 instrumental Analysis Exam 1 February 6 th, 2008 1 Name: 1] A glass electrode was immersed into a solution of ph 4.33 gave a response of 677.1 mv. This electrode was used to measure a sample solution and gave a response of 544.7 mv. What is the ph of the sample? (15 points) 2] A silver electrode responds with a potential of 0.729 V when 25.00 ml of 0.0400 M KBr solution is mixed with 20.00 ml of 0.200 M AgNO 3 (aq). What is the standard reduction potential of Ag +? What is the half reaction for that E 0? (See Homework Problem 22 5c) (15 points) AgBr K sp = 5.0e 13 3] Polarographic analysis of Cd 2+ yielded a diffusion current of 2.89 µa for a 10.0 ml sample. A spike of 1.00 ml of 0.112 mm added to that sample yielded a diffusion current of 4.32 µa. What is the concentration of Cd 2+ in the sample? (15 points) 4] Essay Question: What are the diffusion (or faradaic) and the capacitive current s in voltammetry? Emphasize the differences between them, a diagram may be helpful. Which is the signal, and which is the background? (15 points) 5] What is the 90% confidence interval for the following measurements? (15 points) 10.22 11.03 10.71 10.47 10.83 Half Reaction E 0 O 2 + 4H + + 4e > 2H 2 O +1.23 Fe(CN) 6 3 + e > Fe(CN) 6 4 +0.36 2H + + 2e > H 2 0.00 Pb 2+ + 2e > Pb 0.126 PbSO 4 + 2e > Pb + SO 4 2 0.355 Fe 2+ + 2e > Fe 0.41 6] Which of the species above is the strongest oxidizing agent? (5 points) 7] Which of the above is the strongest reducing agent? (5 points) 8] From the data in the Table above calculate the K sp of PbSO 4. (15 points)

Chem 454 instrumental Analysis Exam 1 February 6 th, 2008 2 Answers 1] A glass electrode was immersed into a solution of ph 4.33 gave a response of 677.1 mv. This electrode was used to measure a sample solution and gave a response of 544.7 mv. What is the ph of the sample? (15 points) E = const + 0.0592 log(h + ) or E = const 0.0592 ph 0.6771 = const 0.0592 (4.33) const = 0.9333 0.5447 = 0.9333 0.0592 ph ph = 6.56 2] A silver electrode responds with a potential of 0.729 V when 25.00 ml of 0.0400 M KBr solution is mixed with 20.00 ml of 0.200 M AgNO 3 (aq). What is the standard reduction potential of Ag +? What is the half reaction for that E 0? (See Homework Problem 22 5c) (15 points) AgBr K sp = 5.0e 13 mmol Br added = 25.0 ml (0.0400 M) = 1.00 mmol Ag + added = 20.0 ml (0.200 M) = 4.00 mmol Ag + left after precipitation = 4.00 1.00 = 3.00 [Ag + ] = 3.00 mmol/45.0 ml = 6.67e 2 E = E 0 0.0592 log (Ag + ) 0.729 V = E 0 0.0592 log 1/(6.67e 2) E 0 = 0.799 V Ag + + e = Ag E 0 = 0.799 V 3] Polarographic analysis of Cd 2+ yielded a diffusion current of 2.89 µa for a 10.0 ml sample. A spike of 1.00 ml of 0.112 mm added to that sample yielded a diffusion current of 4.32 µa. What is the concentration of Cd 2+ in the sample? (15 points) We know that i α C Therefore: i 1 /i 2 = C 1 /C 2 let x = conc [Cd 2+ ] 2.89/4.32 = x/((0.112/11) + (10*x/11)) x = 1.74e 2 mm 4] Essay Question: What are the diffusion (or faradaic) and the capactive current s in voltammetry? Emphasize the differences between them. Which is the signal, and which is the background? (15 points) 5] What is the 90% confidence interval for the following measurements? (15 points) 10.22 11.03 10.71 10.47 10.83 x bar = 10.65 s = {[(10.22 10.65) 2 + (11.03 10.65) 2 + (10.71 10.65) 2 + (10.47 10.65) 2 + (10.83 10.65) 2 ]/(5 1)} 1/2 = 0.32 μ = x bar ± ts/n 1/2 = 10.65 ± 2.132(0.32)/5 1/2 = 10.65 ± 0.31

Chem 454 instrumental Analysis Exam 1 February 6 th, 2008 3 Half Reaction E 0 O 2 + 4H + + 4e > 2H 2 O +1.23 Fe(CN) 6 3 + e > Fe(CN) 6 4 +0.36 2H + + 2e > H 2 0.00 Pb 2+ + 2e > Pb 0.126 PbSO 4 + 2e > Pb + SO 4 2 0.355 Fe 2+ + 2e > Fe 0.41 6] Which of the species above is the strongest oxidizing agent? (5 points) O 2 7] Which of the above is the strongest reducing agent? (5 points) Fe 8] From the data in the Table above calculate the K sp of PbSO 4. (15 points) Cathode: PbSO 4 + 2e 2 > Pb + SO 4 Anode: Pb > Pb 2+ + 2e Cell Rxn and K sp : PbSO 4 > Pb 2+ 2 + SO 4 E 0 = 0.355 + 0.126 = 0.229 V ΔG = nfe = RT ln K E 0 = 0.0592/n log K 0.229 = 0.0592/2 log K sp K sp = 1.8e 8

Chem 454 instrumental Analysis Exam 1 February 6 th, 2008 4

Chem 454 instrumental Analysis Exam 1 February 6 th, 2008 5

Chem 454 instrumental Analysis Exam 2 March 5, 2008 1 You may keep these questions after the exam. Please record your name on the Scantron sheet and turn it in when you are finished. 1] Raman Active stretches are a result of changes in: a) Redox potential b) Dipole Moment c) Polarization d) Intersystem Crossing e) Overpotentials 2] Spectral absorbances in the near IR region are a result of a) Δν = 1 b) Δν > 1 c) Δν < 1 d) Δν = 0 e) Δν = 1 1 2 3 F = fluorescence; P = phosphorescence; E = excitation 3] In the diagram taken from your text (above) the three labeled regions represent a) 1 F, 2 P, 3 E b) 1 P, 2 E, 3 F c) 1 E, 2 P, 3 F d) 1 P, 2 F, 3 E e) 1 E, 2 F, 3 P

4 Chem 454 instrumental 3 Analysis Exam 2 March 5, 2008 2 5 1 2 6 7 8 Questions 4 8 regard the figure above 4] In the diagram above which of the following represent vibrational relaxations? a) 5 b) 7 c) 1 d) 8 e) 4 5) Which of the following represent an absorbance? a) 1 b) 2 c) 3 d) 4 e) 5

Chem 454 instrumental Analysis Exam 2 March 5, 2008 3 6] Which of following represents an emission? a) 1 b) 2 c) 3 d) 4 e) 5 7] Which of the following is an intersystem crossing? a) 2 b) 1 c) 8 d) 5 e) 4 8] Which of the following is a forbidden electronic state transition? a) S 2 S 1 b) S 0 S 1 c) S 1 S 0 d) T 1 S 0 e) None of the above

Chem 454 instrumental Analysis Exam 2 March 5, 2008 4 9] The block diagram above is a representation of a) FT IR b) photodiode array c) CCD d) scanning IR e) potentiostat 10] Which of the following is a form of white noise? a) shot noise b) flicker noise c) 60 Hz d) W lamp e) rap & C+W music 11] Which of the following is a form of environmental noise? a) shot noise b) flicker noise c) 60 Hz d) W lamp e) thermal noise 12] Why is spectrofluorometry potentially more sensitive than spectrophotometry? a) the absorbance, A is not subject to shot noise b) the absorbance, A is proportional to P 0, whereas the analytical signal, F is proportional to the ratio P 0 /P c) the analytical signal F is not subject to 60 Hz noise d) the analytical signal, F is proportional to P 0, whereas absorbance, A is proportional to the ratio P 0 /P e) the absorbance, A is subject to 60 Hz noise I II 13] Which of the compounds above are expected to have greater fluorescent signal and why? a) compound I because its longer lived triplet state b) compound II because of collisional deactivation c) compound I because of great structural rigidity d) compound II because of great structural rigidity e) compound I because of collisional deactivation

Chem 454 instrumental Analysis Exam 2 March 5, 2008 5 Questions 14 17 are based on the diagram above. If needed ask the proctor to draw benzene and biphenyl on the chalk board. 14] Which of spectra is most likely Na vapor? a) b) c) d) 15} Which is most likely biphenyl in hexane? a) b) c) d)

Chem 454 instrumental Analysis Exam 2 March 5, 2008 6 16] Which is most likely benzene in hexane? a) b) c) d) 17] Which is most likely benzene vapor? a) b) c) d) 18] The diagram above is a representation of a) UV vis absorbance spectrophotometer b) Scanning IR c) FT IR d) Fluorometer e) monochrometer

Chem 454 instrumental Analysis Exam 2 March 5, 2008 7 19] The diagram above is a representation of a a) FT IR b) CCD spectrometer c) PDA spectrometer d) Scanning IR e) Scanning UV vis spectrophotometer 20] A Beer s law measurement was made at 355 nm on a 9.00 ml sample with analyte X. Its absorbance A, was found to be 0.200. A spike of 1.0 ml of 1.00 mm compound X was made on that sample and A was found to be 0.250. What is the concentration of X in the sample? a) 5.00 mm b) 1.00 mm c) 0.500 mm d) 0.286 mm e) 0.132 mm

Chem 454 instrumental Analysis Exam 2 March 5, 2008 8 Exam 2 Answers 1. C 2. B 3. E 4. D 5. A 6. 2 7. D 8. D 9. B 10. A 11. C 12. D 13. D 14. A 15. D 16. C 17. B 18. C 19. B 20. D 0.200/0.250 = x/{(1/10)1.00 + (9/10)x} X = 0.286 mm

Name: 10 questions @10 points each 1] Describe chemical ionization in mass spectrometry. What type of information is it likely to give about the analyte? 2] What is the electro osmotic effect in capillary electrophoresis? Why do all species migrate to one electrode? Do they migrate to the cathode or the anode? What is the general order of migration time for cations, anions, and neutrals? Why are neutrals poorly resolved? 3] When considering the van Deemter equation, why does HPLC require small column packing particles? 4] What is gradient elution and how does this differ from an isocratic one? What advantage does gradient elution have over isocratic separations? When using a C 18 stationary phase is it more beneficial to increase or decrease m.p. composition polarity during elution? 5] What is meant by a bulk property detector? Give an example of an HPLC detector that is based on bulk properties and one that is not. 6] Why do capillary columns predominate in analytical GC? 7] What is temperature programming in GC? How does it gain an advantage over single T separations? 8] What is the electron capture detector? Explain its basis for operation, why is N 2 necessary? What types of species are detected with the ECD? 9] Generally, it is thought by many chromatography dilettantes that twice the column length will give you twice the separation power. Comment on why this is false. 10] A GC FID analysis was conducted on a soil sample containing pollutant X. The following separations were conducted: t r (minutes) peak area Injection 1 21.1 ppm Toluene Internal Standard 10.11 36,242 33.4 ppm X 14.82 45,997 Injection 2 21.1 ppm Toluene Internal Standard 10.05 38,774 unknown concentration X 14.77 39,115 What is the concentration of X in the sample? Chem 454 Exam 3 April 23, 2008 1

ANSWERS 1] Describe chemical ionization in mass spectrometry. What type of information is it likely to give about the analyte? See for example: http://en.wikipedia.org/wiki/chemical_ionization 2] What is the electro osmotic effect in capillary electrophoresis? Why do all species migrate to one electrode? Do they migrate to the cathode or the anode? What is the general order of migration time for cations, anions, and neutrals? Why are neutrals poorly resolved? http://en.wikipedia.org/wiki/capillary_electrophoresis 3]When considering the van Deemter equation, why does HPLC require small column packing particles? H = A + B/u + Cu In the v D equation the MT effects predominate, i.e. Cu. Increasing the surface area/bulk ratio of the s.p. is a way to great improve the MT between the two phases. This requires small diameter supports for the s.p. The cost is the pressure required to squeeze the m.p. through the space between the smaller diameter particles. 4] What is gradient elution and how does this differ from an isocratic one? What advantage does gradient elution have over isocratic separations? When using a C 18 stationary phase is it more beneficial to increase or decrease m.p. polarity during elution? Gradient elutions vary the m.p. solvent composition and polarity during separation. This has an advantage over isocratic separations where solvent compostions are kept constant. A gradient elution will allow for the separation of a large variety of species with a broad spectrum of polarities with a much shorter times than isocratic ones. Generally it s best that polarity decrease during separation when using a C 18 s.p. If a non polar m.p. is used at the beginning of the elution, there will be no retention between the solutes and the C 18 s.p. 5] What is meant by a bulk property detector? Give an example of an HPLC detector that is based on bulk properties and one that is not. See problem 28 7 h. Measure a physical property of the m.p. Example UV vis absorbance, fluorescence techniques are examples of bulk property detectors. Electrochemical detectors are not, since they are based on redox exchanges with solutes near the electrode surface. 6] Why do capillary columns predominate in analytical GC? Again this gets back to the v D eqn. The B/u, longitudinal diffusion term contributes most to band broadening in the gas phase. Capillary columns allow for the unobstructed and therefore faster flow of the gaseous m.p. over their packed counterparts. 7] What is temperature programming in GC? How does it gain an advantage over single T separations? Chem 454 Exam 3 April 23, 2008 2

By going from colder to warmer temperatures, it is possible to add another dimension separation of solutes beyond the chromatographic ones. This is based on boiling point differences. Generally the initial T is below that of the solutes species and slowly ramped up. See also problem 27 3. 8] What is the electron capture detector? Explain its basis for operation, why is N 2 necessary? What types of species are detected with the ECD? See http://www.instrumentalchemistry.com/gasphase/pages/ecd.htm Nickel 63 source emits energetic electrons collides with N 2 (introduced as make up gas or can be used as carrier gas) producing more electrons: Ni 63 => e e + N 2 => 2e + N 2 + The result is a constant current that is detected by the electron collector (anode). Chem 454 Exam 3 April 23, 2008 3

As an analyte flows through past the Ni 63 source electron capture is possible by electron withdrawing species: A + e => A Current decreases as a result of e capture by analyte. This is one of the few instances in which a signal is produced by a decrease in detectable phenomenon. Sensitive to electron withdrawing groups especially towards organics containing F, Cl, Br, I also, CN, NO 2 9] Generally, it is thought by many chromatography dilettantes that twice the column length will give you twice the separation power. Comment on why this is false. Remember that Rs α L 1/2. See chapter 26 pages 776 782. So 2x the column length increase resolution by 1.4. Also remember that B/u effects increase with separation time and 2x will increase t by 2x. Also, using a longer column uses more m.p. and decreases experimental throughput. 10] A GC FID analysis was conducted on a soil sample containing pollutant X. The following separations were conducted: t r (minutes) peak area Injection 1 21.1 ppm Toluene Internal Standard 10.11 36,242 33.4 ppm X 14.82 45,997 Injection 2 21.1 ppm Toluene Internal Standard 10.05 38,774 unknown concentration X 14.77 39,115 What is the concentration of X in the sample? 39,115*(36,242/39,115)*(33.4ppm/45,997) = 26.3 ppm Chem 454 Exam 3 April 23, 2008 4