costech instruments ECS 4010 Elemental Combustion System CHNS-O

Similar documents
ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

Rapid Catalyst Screening Reactors

Agilent G2350A Atomic Emission Detector (AED)

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS

Petrochemical. Transformer Oil Gas Analysis - TOGA

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

1.0 Reactive Gas Chromatography Design and Setup Procedure for Catalyst Pelletization & Inlet Packing Software and Method.

METHOD VALIDATION REPORT

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

AOAC Official Method 2016.xx. Determination of Total Sulfur in Fertilizers by High Temperature Combustion

Fusion UV/Persulfate TOC Analyzer

IRMS. perspective. Isotope Ratio Mass Spectrometry.

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0.

The art of elemental analysis

Elemental Analysis: CHNS/O characterization of polymers and plastics

PRINCIPLE. III. EQUIPMENT a. FlashEA 1112 b. Micro balance c. Computer IV. MATERIALS a. Two forceps (curved tip)

Fusion UV/Persulfate TOC Analyzer

SKALAR. your partner in chemistry automation. Primacs SN Protein-Nitrogen Analyzer

CHEMISTRY WORKSTATION. The power of proven quality GIVING YOU PEACE OF MIND

novaa 800 D Atomic Absorption Spectrometer

Elemental Analysis: NCS characterization of paper

Drug Testing Solutions INDIKO DRUG TESTING ANALYZER. 1 P F

PERSPECTIVE STABLE ISOTOPE RATIO MS

AutoChem II 2920 A Catalyst Characterization Laboratory

CLINICAL CHEMISTRY ANALYSER. The economical solution for all your needs GIVING YOU PEACE OF MIND

High-Pressure Volumetric Analyzer

GAS CHROMATOGRAPHY (GC)

SKALAR. your partner in chemistry automation. Formacs series Total Organic Carbon & Total Nitrogen Analyzers

AutoChem II 2920 The Cayalyst Characterization Laboratory

Thermo Scientific GasBench II

Thermo Finnigan LTQ. Specifications

Quantification of total nitrogen according to the Dumas method (Musts and Wines) (Resolution Oeno 13/2002)

EA-IRMS: Fast and Precise Isotope Analysis of Liquids on a Delta V Isotope Ratio MS with a High Temperature Conversion Elemental Analyzer

OXITEST Oxidation Test Reactor

ChromTech HPLC System

RS 1700/1900/2300/2900 High Density Reticle Stockers

TPDRO 1100 Advanced Catalyst Characterization. For Temperature Programmed Desorption, Reduction, Oxidation and Chemisorption

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Magnetic Property Measurement System

RS-C Flexible Reticle Stocker

Defining quality standards for the analysis of solid samples

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

SKALAR. your partner in chemistry automation. Primacs SNC Total Carbon and Total Nitrogen Analyzer

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary.

ConFlo III An Interface for High Precision d 13 C and d 15 N Analysis with an Extended Dynamic Range

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Structural characterization begins with a purity check!

Protein Sequencer PPSQ-31A / 33A C297-E055B

Kjeltec 2300 Analyzer Unit

Headspace Technology for GC and GC/MS: Features, benefits & applications

CapaciTorr HV 200 HIGHLIGHTS

Coflore Agitated Cell Reactor

Understanding Gas Chromatography

JAPAN QUALITY. Automated Clinical Analyzer

Finnigan LCQ Advantage MAX

high performance OPTIC 3 and applications a total analytical solution

CapaciTorr HV Pumps. making innovation happen,together

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

PERSPECTIVE STABLE ISOTOPE RATIO MS

TGA Thermal Gravimetric Analysis

Accurate and Precise Sulfur Analysis using the Thermo Scientific FlashSmart Elemental Analyzer

Oxygen Demand, Chemical

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

473-SHX Dew Point Mirror

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Total Organic Carbon Analysis of Solid Samples for Environmental and Quality Control Applications

Varian Galaxie Chromatography Data System for Preparative HPLC

Mercury Stack Monitor SM-4

Figure 1 Enlargement of Powdered Activated Carbon by microscope.

Thermo Scientific TPDRO 1100 Advanced Catalyst Characterization

SOPHISTICATED DESIGN, INTUITIVE OPERATION, RESEARCH-GRADE RESULTS

Nitrogen/Protein determination of infant food by the Thermo Scientific FlashSmart Elemental Analyzer using helium or argon as carrier gases

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

O P E R A T I N G M A N U A L

SIFT-MS. technology overview

S2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF

The solution for all of your

Microscopy Cryostat System

Sub-ppt Atmospheric Measurements Using PTV-GC-FID and Real-Time Digital Signal Processing

Oxygen Demand, Chemical

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

HYPHENATED TECHNOLOGY GUIDE

2401 Gas (liquid) Chromatography

Freezing point osmometry

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

Hydrogen & Chlorine monitoring for the Chlor-Alkali Industry

Edgetech Instruments Inc.

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Application Note S/SL

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Transcription:

instruments ECS 4010 Elemental Combustion System CHNS-O costech Costech Analytical Tecnologies Inc. 26074 Avenue Hall, Suite 14 Valencia, CA 91355 - USA Phone: (661) 297-2395 Fax: (661) 297-5492 e-mail: sales@costechanalytical.com url: www.costechanalytical.com

ECS 4010 Innovation in elemental analysis The Elemental Combustion System 4010 was designed as an advanced analytical platform for CHNS-O elemental analysis and Nitrogen/ Protein determination. It is based on an automatic analytical unit whose operation - from sampling up to signal detection - is microprocessor controlled. It represents an evolution in the technique of elemental analysis by "flash combustion/chromatographic separation and multi-detector techniques". Traditionally, automatic instruments for CHNS-O elemental analysis have been divided into two groups; micro and macro elemental analysis. Samples for micro EA are easily analyzed by sophisticated automatic instruments using the technique of combustion/gas chromatography. For the analysis of stable isotopes of CHNS-O, a sampling system is required which does not contaminate the sample with atmospheric nitrogen and oxygen, especially working at very low levels. Advanced, highly stable catalysts are required to avoid any material exchange to the combusted gases. To increase throughput and minimize maintenance time and cost, a simple approach to the design of the analyzer is essential, especially for macro sample analysis where all combustion gases pass through the detector system without splitting or diluting. Instrument description Starting from the basic furnace design; the ECS 4010 has two, large capacity (up to a 26 mm OD reactor) furnaces. Optional fittings let you quickly and easily switch between combustion/reduction reactors of different diameters. You can work with reactors from 10,5 mm to 26 mm OD. The furnaces are mounted in a specially designed SS enclosure with an extremely efficient insulating material. This keeps the entire cabinet cool to the touch and allows the furnaces to heat from ambient to operating temperature in 1.5 hours. The electronics and power supplies are completely isolated from the furnace compartment and have their own separate cooling fan. The ECS monitors, and can display, the temperatures of the power supply, and electronics. It will also display the input line voltage supply. The ECS 4010 consists of three modules; The first module is the combustion system, the second is the detector system, and the third is the data handling system. When the three systems are combined the user can choose the required analytical configuration. The first module consists of sampling, combustion and pneumatics. The autosamplers available are a sealed, Zero Blank sampler, and an open carousel sampler, where samples can be added continuously. The movement of the Zero Blank autosampler is controlled by a microstepping motor. You can choose either a 32 or 50 position carousel through the instrument software, and since it is completely sealed to atmosphere there is no contamination of the samples from nitrogen or oxygen. This is especially useful for stable isotope analysis. The second choice of sampler

has carousels which are open to the atmosphere, but samples can be added continuously and the number of sample positions is 147. The ECS 4010 is equipped with two furnaces. Temperature control of the combustion furnace is up to 1100 o C, and the reduction furnace 800 o C. The furnace dimensions and special fittings allows you to use a wide variety of reactors to tailor the analyzer to your laboratory needs (small and large samples, CHNS-O analysis, and N/Protein). The connection fittings for the quartz reactors make it fast and easy to replace the inserts in the combustion reactors (removal of ash and residue), for longer tube and catalyst life. The unique pneumatic system can be switched between three operating modes; Micro, Semi-Micro and Macro. By selecting a mode you choose the volume of oxygen for sample combustion. The gases (helium, oxygen and servo) are controlled by reliable SS diaphragm regulators for accurate flow control. Servo gas control is provided for use with our pneumatically actuated autosampler. A separate purge regulator is provided for flexibility in purge gas flow and volume. separated by gas chromatography for CHNS-O analysis, or sent to a mass spectrometer for isotopic analysis. For the gas chromatographic technique a high stability oven, with temperature control from 30-110 0 C, and a wide range of GC column lengths are available. The TCD (thermal conductivity detector) has been specially designed for this application, special features include; preheating of combustion gases before entering the detector to stabilize gas temperature, and a twin encapsulated filament which requires no reference gas flow. The advantages of the this are; simplicity of the combustion/detector system (low maintenance, minimum down time), efficiency of the combustion, and no splitting or dilution of the combustion gases, all combustion products are measured. The third module is EAS, our Windows TM based software package, for instrument control, data acquisition and report generation. A multichannel 24 bit A/D interface connects the ECS to a PC for data acquisition and instrument control. Sample information is entered, the software collects raw data from the TCD, creates the calibration, and generates reports including statistical information. Data can be easily exported to EXCEL TM in ASCII format for post-run calculations or exporting to LIMS. A reprocessing software option is available for setting up methods and transferring data from a remote computer, or working with data out of the laboratory. Interface boards can be ordered for 1,2, or 4 channels. The second module is the detector system for measuring the combustion (or pyrolysis) products. These combustion gases can be

OPERATING PRINCIPLE During normal system operation, helium carrier gas circulates within the analytical circuit which consists of a combustion reactor for CHNS and N/Protein, or a pyrolysis reactor for Oxygen. The carrier gas brings the products of combustion, or pyrolysis to a gas chromatographic separation column and TCD detector for CHNS-O analysis, or a multidetector system for N/Protein determination. C/H/N/S Elemental Analysis At the start of the analytical cycle the helium carrier gas is switched to a volume of oxygen which is chosen by the operator depending on the size and composition of the sample. The samples are dropped sequentially into the combustion reactor prior to the arrival of oxygen. The sample and tin capsule react with oxygen and combust at temperatures of 1700-1800 o C and the sample is broken down into it s elemental components, N 2, CO 2, H 2 O and SO 2. High performance copper wires absorb the excess oxygen not used for sample combustion. The gases flow through the gas chromatographic (GC) separation column which is kept at a constant temperature (+/- 0.1 o C). As they pass through the GC column, the gases are separated and are detected sequentially by the TCD. The TCD generates a signal, which is proportional to the amount of element in the sample. The EAS software compares the elemental peak to a known standard material (after calibration) and generates a report for each element on a weight basis. For Continuous Flow Isotope ratio Mass Spectroscopy, the separated gases are carried to the mass spectrometer interface and into the MS source. Oxygen Analysis Helium carrier gas circulates through the analytical circuit, which consists of a pyrolysis reactor which is filled with a special nickelized carbon wool contact material heated to 1080 o C, a trap for acidic gases formed by the pyrolysis, a GC column which will separate the gas mixture, and a TCD. Samples are dropped automatically into the pyrolysis reactor, break down and the released oxygen reacts with the nickel carbon wool to form CO (2C + O 2 = 2 CO) and N 2, if present in the sample. The mixture of N 2 and CO gases flow through the gas chromatographic (GC) separation column which is kept at a constant temperature (+/- 0.1 o C). As they pass through the GC column, the gases are separated and the CO peak is detected by the TCD. The TCD generates a signal which is proportional to the amount of CO in the sample. The EAS software compares the CO peak to a known standard material (after calibration) and generates a report for oxygen concentration on a weight basis.

ECS 4010 features and benefits Sampling options Zero Blank sampler, 32 or 50 positions 150 position open carousel sampler Direct injection (syringe) of gases Combustion and Reduction Tubes Diameters (OD) 10.5 mm 18 mm 20 mm 26 mm Simple, easy fittings to change tube diameters. Inserts for ash removal G.C. Oven and Separation Column Temperature range 30-110 o C Temperature control +/- 0.1 o C Standard and custom column lengths for different applications Dual filament TCD No reference gas required Pre-heating of combustion gases Mass Spectrometer or Other Detectors EAS Software Windows 95/98/NT Instrument control via RS232 Export data to Excel or LIMS Actualizes results

AUTOSAMPLERS Interior view - 50 position carousel The Zero Blank autosampler developed by Costech, uses a sealed carousel design. All samples are purged simultaneously with helium in an enclosed chamber. This eliminates any nitrogen background (from atmosphere) which is introduced in the open carousel sampler when it moves to drop the sample into the reactor. The microstepper motor which drives the autosampler can switch from a 50 position carousel to a 32 position carousel for large or bulky samples. The autosampler controls (set in the ECS software) are; manual advance, carousel selection (50 or 32 position), and jog, which is used to initially align the carousel. Optional Isolation Valve An optional valve to minimize system changes is available. It replaces the standard drop tube and is the same length. The carrier gas connection is below the valve and a separate purge connection is provided above the valve. When opening the Zero Blank Autosampler carousel to add samples it is only necessary to turn the valve, isolating the entire carousel section. The carrier gas will continue to flow through the rest of the analytical circuit. After adding samples to the carousel, close the lid, turn on the purge flow and let the carousel purge for 2-5 minutes. Close the purge vent, turn off the purge flow, and open the isolation valve.

Pneumatic Autosampler Our 150 position pneumatic autosampler has carousels (three) which are open to atmosphere, and samples can be added continuously while running. The sample holes in the carousels are 11.5 mm in diameter and can accommodate samples like glass fiber filters or large, bulky samples. A large viewing port allows you to clearly see the sample combustion during the analysis. Continuous Flow EA-IRMS The ECS 4010 uses the combustion/gc separation technique for elemental analysis. This makes it perfectly suitable for continuous flow, stable isotope analysis. All instrument parameters are controlled by an internal microprocessor, no external computer or software is required when connected to a mass spectrometer. All that is needed for the EA/MS application is the ECS base unit and an autosampler. The ECS will accept an external start signal from any mass spectrometer, so the two instruments can function together. Our Zero Blank autosampler is unique, and is especially suited for EA-IRMS:The sealed carousel design eliminates any nitrogen background (blank). Two interchangeable carousels, 50 positions for normal size samples, and 32 positions for large samples, are available and can be changed in just 1 minute. An optional isolation valve minimizes system changes when adding samples to the carousel. To measure total CHNS-O, as well as the isotope ratios from the mass spectrometer simultaneously, our EAS software can be synchronized with the mass spectrometer so the two instruments run in the same time frame. This is because EAS will accept an external start signal; the mass spectrometer software starts the ECS, then the ECS sends an external start signal to EAS to begin data acquisition. Mass Spectrometer for Stable Isotope Analysis

INSTRUMENT CONTROLS Select Operational Mode CHNS or Oxygen Analysis Micro/Semi-Micro/Macro Set Temperatures Combustion/Reduction Furnaces GC Oven Program Timing Functions Run time Sample Start Oxygen injection Monitor Line voltage Electronics & power supply temp. TCD Signal gain Electronic zero TECHNICAL SPECIFICATIONS Sample Size Micro <1-5 mg (density dependent) Semi-Micro 5-50 mg Macro up to 500 mg of organic material Measuring Range Autosamplers Catalyst consumption Dimensions Power Software 0-100% CHNS-O Zero Blank, sealed carousel, microstepper motor 147 position, open carousel, pneumatic >1000 Analyses for Micro & Semi-Micro 79 x 55 x 34 cm 220V 50/60 Hz Windows TM 95/98/2000/NT

EAS Software for Elemental Analysis EAS is a data station developed for acquiring and evaluating data from the TCD (Thermal Conductivity Detector) in the ECS 4010 and reporting the elemental concentrations. A Sample Table and Calibration File are created containing information on standard reference materials (used for calibration) and unknown samples. After the calibration samples are analyzed and a calibration curve established, concentration results for unknown samples will be reported. The EAS station is designed as a board to be installed in a PC computer and the corresponding software package for Windows TM. The board contains one to four independent integrating A/D converters and controlling inputs and outputs. The station allows for simultaneous data acquisition from up to four detectors independently in the background, data analysis, baseline correction and for calibrated or non-calibrated data processing. Results may be printed on any printer with a wide range of optional print parameters, and tables, data, and chromatograms exported to files or directly to other programs running under Windows TM. Calibration files enable you to carry out calibration-based calculations with an external standard method. Each calibration file may contain up to 20 concentration levels for each component. Computer and operating system requirements The EAS station may be run under any of the following systems: Windows 3.1, 3.11, Windows 95/98/ ME and Windows NT/2000. For Windows 3.1 and 3.11 with moderate demands on speed a 386/40 computer with 4 to 8 MB memory is sufficient. For Windows 95/98/ME we recommend at least 486/100 computer with 16 MB memory, and for Windows NT/2000 a Pentium/90 computer with 32 MB.

CONSUMABLES Costech offers a complete line of consumables and accessories for its lines of analytical instruments. Capsules, quartz tubes, reagents, standard reference materials, oxidation and reduction catalysts, chromatographic columns, autosamplers, and data acquisition software packages. To reduce the cost of sample analysis it is important to increase the number of samples which can be run using the minimum amount of catalysts, and to reduce the cost of disposal of the exhausted catalysts and reagents. New, optimized catalysts are available for all configurations and applications. Catalysts are certified for physical/chemical properties, chemical purity and reactivity. Quartz reactors Tin and Silver Capsules Catalysts Copper Wires Standards Reagents GC Separation Columns

PART NUMBERS 40.11.001 Base Unit configured for pneumatic autosampler 40.10.001 Base Unit configured for pneumatic and electronic autosampler 41.10.000 Pneumatic autosampler, w/1, 50 position carousel 41.10.100 Carousel number 1 41.10.200 Carousel number 2 41.10.300 Carousel number 3 41.00.001 Zero Blank Autosampler, w/50 position carousel 41.00.002 Zero Blank Autosampler, w/32 position carousel 41.00.100 Control module for Zero Blank Autosampler 41.00.200 50 position carousel for the Zero Blank autosampler 41.00.300 32 position carousel for the Zero Blank autosampler 41.00.110 Isolation valve for Zero Blank autosampler 41.00.120 Gas injection device, in-line 41.00.130 Direct gas injection device, for combustion tube 42.10.001 EAS Software package, includes single channel A/D board, software and cable 42.10.002 EAS Software package, includes 2 channel A/D board, software and cable 42.10.004 EAS Software package, includes 4 channel A/D board, software and cable 099006 Sartorius M2P Microbalance, 1 ug readability (0.001 mg) 43.13.001 Consumables kit for 1000 Nitrogen Analyses 43.13.002 Consumables kit for 1000 Nitrogen/Carbon Analyses 43.13.003 Consumables kit for 1000 Nitrogen/Carbon/Hydrogen Analyses 43.13.004 Consumables kit for 1000 Nitrogen/Carbon/Sulfur Analyses 43.13.005 Consumables kit for 1000 Nitrogen/Carbon/Sulfur/Hydrogen Analyses 43.13.006 Consumables kit for 1000 Nitrogen/Carbon/Sulfur/Hydrogen- Oxygen Analyses