GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Similar documents
637. Thiamethoxam. HPLC method

Chromatography. Gas Chromatography

DIQUAT DIBROMIDE. The Determination of Ethylene Dibromide in Diquat Dibromide and Diquat Dibromide / Paraquat Dichloride SL Formulations

High Performance Liquid Chromatography

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

Method for Characterization of Gum Rosin by Capillary Gas Chromatography

Understanding Gas Chromatography

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

H 3 CO H 3 CO S CH 3

-xt. -xt SYSTEM. Specifications for PAL-xt Systems. Valid for PAL-xt System models only. Prep and Load Platform

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

GAS CHROMATOGRAPHY (GC)

Principles of Gas- Chromatography (GC)

Gas Chromatography. Introduction

Volatile organic compounds (VOCs):

Packings for HPLC. Packings for HPLC

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions

Chapter content. Reference

PYRIPROXYFEN TECHNICAL

RESOLUTION OENO 33/2004 DETERMINATION OF SHIKIMIC ACID IN WINE BY HPLC AND UV-DETECTION

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

LC Technical Information

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Theory and Instrumentation of GC. Chromatographic Parameters

Introduction to Gas Chromatography

Sulfotepp impurities in Chlorpyrifos EC formulations

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Method for the determination of 1,3-butadiene

Instrumental Chemical Analysis

Gas Chromatography (GC)

7 INSTRUMENTAL CHROMATOGRAPHY

Determination of Pesticides in Aqueous Samples by On-Line Coupling Solid-Phase Extraction to Gas Chromatography with At-Column Concentrating Interface

Biochemistry. Biochemical Techniques HPLC

TECHNICAL TEMEPHOS. 1. Specification. Full specification WHO/SIT/19.R4 Revised 10 December Description

Chapter 27: Gas Chromatography

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

ProPac WCX-10 Columns

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

TECHNICAL BRODIFACOUM

CIPAC. CIPAC Free relevant impurities methods:

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

NEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009)

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Analytical Chemistry

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

STANDARD OPERATING PROCEDURES

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

Application Note 032

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

Selection of a Capillary

GB/T / ISO :2006

Chemistry Instrumental Analysis Lecture 27. Chem 4631

Speakers. Moderator. John V Hinshaw GC Dept. Dean CHROMacademy. Tony Taylor Technical Director CHROMacademy. Dave Walsh Editor In Chief LCGC Magazine

for Acclaim Mixed-Mode HILIC-1 Column

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Experiment UPHPLC: Separation and Quantification of Components in Diet Soft Drinks

Introduction to Capillary GC

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Liquid Chromatography

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Paints and varnishes Determination of volatile organic compound (VOC) content. Part 2: Gas-chromatographic method

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Introduction to Capillary GC

High Pressure/Performance Liquid Chromatography (HPLC)

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

ION CHROMATOGRAPHY SYSTEM S 150

Gas Chromatography notes

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

METHOD 8111 HALOETHERS BY GAS CHROMATOGRAPHY

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Hints for Strong Ion Exchange Resins

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

Selection of a Capillary GC Column

LUMEFANTRINUM LUMEFANTRINE

Chapter 23 Introduction to Analytical Separations

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

High Performance Liquid Chromatography

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

2401 Gas (liquid) Chromatography

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

Physical Separations and Chromatography

Quantitative determination of ethephon in soluble concentration (SL) by Ion chromatography

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography 1

Basic Principles for Purification Using Supercritical Fluid Chromatography

Determination of Volatile Substances Proof of Food Adulteration

Chemical Laboratory Techniques

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

Transcription:

Page 1 of 13 CIPAC/4105/R GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY Prepared for CIPAC by Dr M J Tandy*, P M Clarke and B White (UK) The rapid expansion in use of chromatographic methods for pesticide product analysis has led to a wide choice of chromatography columns and variation in experimental parameters, along with increased demands on instrumentation. Whilst this approach may suit agrochemical manufacturers and suppliers of a limited range of specific products, its inherent complexity can cause problems when implementing on a global basis in laboratories where many different pesticide products have to be analysed and there is less familiarity with specific product analysis. Authors of analytical methods, intended for global use via CIPAC collaborative study, should be encouraged to streamline their procedures preferably during in-house development but certainly prior to collaborative study. This paper presents guidelines on how to simplify the design of capillary gas chromatography (GC) and high performance liquid chromatography (HPLC) methods. Emphasis is placed on those important experimental parameters which can be changed to optimise method performance or kept constant in order to minimise method variation. Other parameters are identified as less critical. The key choice of chromatography column is simplified significantly to a recommended short list. Guidance is also given on the need and use of solvents, gases and internal standards. Each parameter is listed within a method format, to provide clarity along with individual explanation of its importance. These guidelines concentrate on chromatographic parameters. They are not intended to provide guidance on sample preparation or indeed acceptable quality of results. These are covered in other CIPAC guidelines such as Guidelines for CIPAC Collaborative Study Procedures for Assessment of Performance of Analytical Methods and Guidelines on method validation to be performed in support of analytical methods for agrochemical formulations. However, one benefit of using such a method format is to encourage the standardised layout of chromatographic parameters within a CIPAC method.

Page 2 of 13 THE DETERMINATION OF ACTIVE INGREDIENT IN FORMULATED MATERIALS BY CAPILLARY GAS CHROMATOGRAPHY Prepared for CIPAC by P M Clarke, M J Tandy and B White (UK)

Page 3 of 13 1 SCOPE This capillary gas chromatography (GC) method provides for the determination of active ingredient in formulated material. 2 SUMMARY OF METHOD The active ingredient content is determined by capillary gas chromatography, using an internal standard procedure. Significant parameters of the method include :- 3 CHEMICALS split injection medium bore fused silica capillary column flame ionisation detection. [State grade and recommended supplier] Safety Information All chemicals should be handled according to normal laboratory safety procedures, in a fume cupboard, wearing a laboratory coat, eye protection and suitable gloves. If in any doubt about the nature and hazards of the chemicals used in this method consult an appropriate safety manual such as: Hazards in the Chemical Laboratory, Edited by Luxon, Royal Society of Chemistry, Fifth Edition, 1992, London, ISBN 0-85186-229-2. The Sigma-Aldrich Library of Chemical Safety Data, Edited by Lenga, Second Edition, 1988, Milwaukee, WI, ISBN 0-941633-16-0. Organic Solvent, analytical grade (typically acetone, butyl/ethyl acetate or haloalkanes) Ideally this solvent should also be able to be used as extraction solvent, in which case it may be necessary to check for reaction of active ingredient during method development. Solvent chosen should not be of toxicological concern. Internal Standard, high purity (98% +) The volatility and structural functionality of the internal standard are critical to the precision obtained. Ensure internal standard is readily available from a global supplier. A high purity is desirable to minimise possible interferences. Active Ingredient, Analytical Standard of certified purity. Store refrigerated (where appropriate).

Page 4 of 13 4 APPARATUS AND OPERATING CONDITIONS The apparatus listed below is that used to establish the method. Consideration must be given to confirmation of the method on other makes of equipment, providing equivalent performance, to ensure that they are suitable. Instrument Injection Mode Injection Liner GC system, equipped with split/splitless injection and flame ionisation detection, operated in split mode. Use of an autoinjector is recommended to enable reproducible volume and speed of injection. The choice of liner, amount and type of packing, can have a critical effect on precision. Liners need to be checked or replaced on a regular basis. Otherwise a build up of less volatile material can result in adsorption, or reaction. Used split injection liners should be decontaminated as appropriate prior to silanisation. Injection load Column Dimensions Film Thickness Stationary Phase 0.5-2µl, usually 1µl (syringe size typically 10µl). Fused silica; length : 10-25 m internal diameter : 0.2-0.25 mm (0.32 mm may need to be considered) These dimensions offer a good compromise between column efficiency, analysis time and capacity. 0.1-0.25µm (sufficient phase to minimise capacity factors whilst still maintaining column efficiency and minimise elution temperature). Crosslinked dimethyl polysiloxane. This is the preferred phase as it is robust with a wide range of applications, and should be used where there are no specific benefits in using another phase. Other recommended stationary phases:- Phase Crosslinked 5% phenyl polysiloxane 95% dimethyl polysiloxane. Crosslinked 14% cyanopropylphenyl 86% dimethyl polysiloxane. Crosslinked 50% phenyl 50% dimethyl polysiloxane. Crosslinked 50% trifuoropropyl 50%. dimethyl polysiloxane Comments Improved selectivity for aromatics over dimethyl polysiloxane phase. Medium polarity phase, unique selectivity. Applicable to analysis of medium polarity compounds. Highly selective phase for resolution of halogenated compounds.

Page 5 of 13 Injection Port Temp This will need to be evaluated to minimise breakdown and optimise precision. Oven Temperature Isothermal temperature : The temperature at which the active ingredient elutes between 5-10 minutes (H 2 carrier gas) or 10-15 minutes (He carrier gas). A shorter elution time will generally reduce peak efficiency and resolution. Ensure temperature chosen is within the limits set by the column manufacturer. Initial time : Sufficient to elute active ingredient and internal standard. Temperature programme to remove formulation adjuvants if necessary Programme rate 1 Final temperature 1 Final time 1 : : : Maximum ramp rate of GC system Within the temperature limit of the column Sufficiently long to elute all components Detector Temperature 325 C or 25 C above final temperature 1. Gas Filtration Detector Gas Flow Rates Carrier gas All gases should be purified through molecular sieves. The carrier gas should be further purified through an oxygen trap. According to manufacturers recommendations. Hydrogen or helium, preferably hydrogen. The benefits of using hydrogen over helium are less critical instrument setup and quicker analysis times. However hydrogen may be reactive with reducible compounds, eg nitro compounds. Average Linear Gas Velocity : 45-55 cm s -1 (hydrogen carrier gas) 25-35 cm s -1 (helium carrier gas) The above values cover optimum performance for the recommended column internal diameter range. A higher linear velocity may be desirable to shorten the analysis if there is sufficient resolution. Split flow 60-250 ml min -1 (hydrogen carrier gas) 30-200 ml min -1 (helium carrier gas) This parameter is not generally critical when used within the above ranges. The term split flow is recommended over split ratio for ease of method setup. Data handling Correct setting of integration parameters is important for accurate definition of peak start and end points.

Page 6 of 13 5 SUITABILITY Stored or new columns may require conditioning prior to use. Perform replicate injections of calibration solution until acceptable, repeatable chromatography is obtained. Compare the chromatogram obtained with that shown in Figure 1. Provide an example chromatogram, Figure 1, with the peak of interest on scale clearly showing peak shape and retention. Measure the retention time of the active ingredient (give an acceptable time window in minutes e.g. 4.5 ± 0.5 minutes). If the peak retention time is not within the quoted window the oven temperature or the column head pressure may be adjusted but only within stipulated values (e.g. ± 10 C or ± 1 psi, respectively) Further adjustments could indicate unacceptable experimental procedure. 6 DETERMINATION Perform an injection of a sample solution. Provide an example chromatogram, Figure 2. This enables comparison with Figure 1 to illustrate the separation of other constituents eg formulation adjuvants. Perform replicate injections of the calibration and sample solutions following the recommended sequence of injection. If column performance deteriorates substantially during use, check the condition of the split injection liner and replace if necessary. If column performance remains unacceptable, then remove approximately 10 cm length from the column at the injection end. 7 METHOD VALIDATION SUMMARY Precision (The method should state the maximum relative standard deviation allowable relevant to the appropriate active ingredient content e.g. RSD < 2.1 for 5% active ingredient). Accuracy (The method should state the allowable recovery range of the active ingredient from the sample, relevant to the appropriate active ingredient content e.g. 97.0-103.0% for 1-10% active ingredient). Linearity (The method should state the range over which response is linear e.g. ± 20% of the nominal active ingredient concentration). 8 REFERENCES CIPAC/3807R Guidelines on method validation to be performed in support of analytical methods for agrochemical formulations. Guidelines for CIPAC collaborative study procedures for assessment of performance of analytical methods.

Intensity (mv) Intensity (mv) Page 7 of 13 Figure 1: Chromatogram Of Calibration Solution Multichrom 180 150 120 Active Ingredient Internal Standard 90 60 30 0 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 Time (minutes) Figure 2: Chromatogram Of Sample Solution 20.0 Multichrom 18.0 16.0 14.0 Active Ingredient Internal Standard 12.0 10.0 8.0 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 Time (minutes)

Page 8 of 13 THE DETERMINATION OF ACTIVE INGREDIENT IN FORMULATED MATERIALS BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY Prepared for CIPAC by P M Clarke, M J Tandy and B White (UK)

Page 9 of 13 1 SCOPE This high performance liquid chromatography (HPLC) method provides for the determination of active ingredient in formulated material. 2 SUMMARY OF METHOD The active ingredient content is determined by high performance liquid chromatography using an external standard procedure where possible. Internal standards are generally not essential with automated or overfilled loop injectors but may be required to ensure accurate preparation of sample solution. Significant parameters of the method include: * reversed phase chromatography with a base deactivated endcapped octadecylsilyl bonded silica column (where possible) * column temperature control * ultra-violet (UV) detection (where possible) * samples prepared in initial mobile phase (when achievable) 3 CHEMICALS [State grade and recommended supplier] Safety Information All chemicals should be handled according to normal laboratory safety procedures, in a fume hood wearing a laboratory coat, eye protection and suitable gloves. If in any doubt about the nature and hazards of the chemicals used in this method, consult an appropriate safety manual such as: Hazards in the Chemical Laboratory, Edited by Luxon, Royal Society of Chemistry, Fifth Edition, 1992, London, ISBN 0-85186-220-2. The Sigma-Aldrich Library of Chemical Safety Data, Edited by Lenga, Second Edition, 1988, Milwaukee, WK, ISBN 0-941622-16-0. Organic solvent, HPLC grade (typically methanol or acetonitrile). Water, purified conforming to ASTM type 2 or HPLC quality. Active Ingredient, Analytical Standard of certified purity. Store refrigerated (where appropriate).

Page 10 of 13 4 APPARATUS AND OPERATING CONDITIONS The apparatus listed below is that used to establish the method. Consideration must be given to confirmation of the method on other makes of equipment, providing equivalent performance, to ensure that they are suitable. Instrument Injection Mode Injection Load Column Dimensions Particle Size Stationary Phase HPLC system equipped with pump, auto-injector, column oven and UV variable wavelength detector. Use of an automated injector system or manually overfilled loop is recommended for consistency of volume of injection. 5-20 µl. Injection volume is not generally critical. Ensure that the response of the component of interest is within the linear range of the detector. Stainless steel; length : 100-250 mm internal diameter : 3-5 mm A length of less than 100 mm may give a less robust method. A diameter of less than 3 mm requires specialist equipment. A short guard column, packed with appropriate stationary phase, is recommended. Nominal particle size 3-5 µm. Deviation from this size may give rise to operational or performance problems. Base deactivated endcapped octadecylsilyl bonded silica. This is the preferred phase as it is robust with a wide range of applications. Alternative Stationary Phases Column Strong Anion Exchange (SAX) Strong Cation Exchange (SCX) Bonded Phase Silica (eg Cyano or Amino) Silica Comments For ion exchange chromatography of anions. For ion exchange chromatography of cations For specialist applications. For normal phase chromatography. Other stationary phases may be used where these give a significant benefit.

Page 11 of 13 Column Temperature Mobile Phase Flow Rate Temperature control eg at 40 C ensures consistent retention times. Other values may be used where temperature is significant in improving separation. Avoid using the description ambient as a column temperature. Express each component as a percentage by volume before mixing where possible. Measure organic and aqueous potions separately. ph may be critical for ionisible compounds. Avoid gradients unless necessary for removal of strongly retained formulation adjuvants. Include example recipe. Degassing of mobile phase is recommended. 0.5-2.0 ml min -1. Choose appropriate flow rate for column diameter eg 1.0 ml min -1 for 4.6mm id, 0.5 ml min -1 for 3.2mm id. Detector Wavelength Wavelength selected should be a wavelength in the UV spectrum of active ingredient where the change in slope is not pronounced, eg maximum or minimum. Always use a wavelength more than 10nm away from the mobile phase UV cut-off. Data Handling System Correct setting of integration parameters is important for accurate definition of peak start and end points. 5 SUITABILITY Stored or new columns may require conditioning with mobile phase(s) prior to use. State mobile phase(s), time and flow rate. Perform replicate injections of calibration solution until acceptable, repeatable chromatography is obtained. Compare the chromatogram obtained with that shown in Figure 1. Provide an example chromatogram, Figure 1, with the peak of interest on scale clearly showing peak shape and retention. Measure the retention time of the active ingredient (give an acceptable time window in minutes eg 6.3 ± 0.5 minutes). If the peak retention time is not within the quoted window, the mobile phase may be adjusted but only within stipulated values eg for mobile phase containing 50 % methanol, the methanol concentration may be adjusted by ± 5%). Further adjustments could indicate unacceptable experimental procedure.

Page 12 of 13 6 DETERMINATION Perform an injection of a sample solution. Provide an example chromatogram, Figure 2. This enables comparison with Figure 1 to illustrate the separation of other constituents eg formulation adjuvants. Perform replicate injections of the calibration and sample solutions following the recommended sequence of injection. If column performance deteriorates substantially during use, replace the guard column. Columns may require washing prior to storage. State mobile phase(s), time and flow rate. 7 METHOD VALIDATION SUMMARY Precision (The method should state the maximum relative standard deviation allowable relevant to the appropriate active ingredient content eg RSD r < 2.1 for 5% active ingredient). Accuracy (The method should state the allowable recovery range of the active ingredient from the sample, relevant to the appropriate active ingredient content eg 97.0-103.0% for 1-10% active ingredient). Linearity (The method should state the range over which response is linear eg ± 20% of the nominal active ingredient concentration). 8 REFERENCES CIPAC/3807R Guidelines on method validation to be performed in support of analytical methods for agrochemical formulations. Guidelines for CIPAC collaborative study procedures for assessment of performance of analytical methods.

Intensity Intensity Page 13 of 13 Figure 1: Chromatogram Of Calibration Solution 140 120 100 Active Ingrdient 80 60 40 20 0.0 1.5 3.0 4.5 6.0 7.5 9.0 10.5 Time (minutes) Figure 2: Chromatogram Of Sample Solution 140 120 100 Active Ingredient 80 60 40 20 0.0 1.5 3.0 4.5 6.0 7.5 9.0 10.5 Time (minutes)