Varian 380-LC. ELSD for Routine HPLC and GPC Analysis. Key Benefits

Similar documents
Agilent 1260 Infinity Evaporative Light Scattering Detector (ELSD)

Varian 385-LC. ELSD for Low Molecular Weight Compounds

Agilent 385-ELSD Evaporative Light Scattering Detector

Agilent 385-ELSD Evaporative Light Scattering Detector

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

Analysis of pharmaceuticals using HPLC with evaporative light scattering detection

Evaporative Light Scattering Detector (ELSD)

Quantitation of Surfactants in Samples by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

Discover what you re missing

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Sensitive HPLC Method for Triterpenoid Analysis Using Charged Aerosol Detection with Improved Resolution

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

Fast methods for the determination of ibuprofen in drug products

Quantitation and Characterization of Copper Plating Bath Additives by Liquid Chromatography with Charged Aerosol Detection

Basic Principles for Purification Using Supercritical Fluid Chromatography

Direct Analysis of Surfactants using HPLC with Charged Aerosol Detection

Varian Galaxie Chromatography Data System for Preparative HPLC

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Instrumentation & Software

HPLC Analysis of Non-volatile Analytes Using

Using the Agilent 1290 Infinity II Multicolumn Thermostat with Extreme Temperatures and Flow Rates

No Chromophore? No Problem! Universal HPLC Detection. The world leader in serving science

Routine MS Detection for USP Chromatographic Methods

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

HPLC Praktikum Skript

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

Enhancement of Linearity and Response in Charged Aerosol Detection

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Corona Veo the Next Generation Charged Aerosol Detector

penta-hilic UHPLC COLUMNS

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

High Throughpu[ Separations and Structural Information Achieved with Automated LC/MS. Michael P. Balogh, Matthew J. Dilts Waters Chromatography

Analysis of Silicone Oils by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

DEMONSTRATING SUPERIOR LINEARITY: THE ACQUITY UPLC PHOTODIODE ARRAY DETECTOR

Selecting Detectors for Compounds with No Optical Absorbance


Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

ChromTech HPLC System

Comprehensive Polymer Analysis Strategies

Peptide Isolation Using the Prep 150 LC System

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

IN QUALITATIVE ANALYSIS,

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Optimizing GPC Separations

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Charged Aerosol Detection and Evaporative Light Scattering Detection Fundamental Differences Affecting Analytical Performance

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

HPLC Analysis of Nonvolatile Analytes Using Charged Aerosol Detection

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

LC and LC/MS Column Selection Flow Chart

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Introduction to Fourier Transform Infrared Spectroscopy

Application Note. Author. Abstract. Pharmaceutical QA/QC. Vinayak A.K Agilent Technologies Bangalore, India

Analytical Instrumentation

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Nexera UC Unified Chromatography

MODERN HPLC FOR PRACTICING SCIENTISTS

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

for Acclaim Mixed-Mode HILIC-1 Column

Charged Aerosol Detection 101

C18 Column. Care & Use Sheet

AUTOMATED CHROMATOGRAPHY SYSTEMS. Featuring EZ Prep

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Pharmaceutical Analysis of API and Counter Ions in Complex Formulations in a Single Injection

Chemistry Instrumental Analysis Lecture 27. Chem 4631

A Novel LC-ELSD Method for the Quantification of 2-Deoxy D-Glucose Using HILIC Chromatography

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

Automating Gradient Method Development in Flash Chromatography For Greater Productivity and Minimizing Solvent Use

Automated and accurate component detection using reference mass spectra

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

ChromegaChiral TM CSP Media and Columns

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

A Total Solution for Explosives Analysis by Reversed-Phase HPLC with a Parallel HPLC System

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

IR-LC Deposition and Detection System. Polymer Deformulation and Additive Analysis by a Single GPC-IR Run

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Quantitation and Characterization of Copper and Nickel Plating Bath Additives by Liquid Chromatography

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets

Transcription:

D ATA S H E E T EVAPORATIVE LIGHT SCATTERING DETECTOR ELSD for Routine HPLC and GPC Analysis Evaporative light scattering detectors are ideal for detecting analytes with no UV chromophore as they do not rely on the optical properties of a compound. The Evaporative Light Scattering Detector is the latest high performance ELS detector from Varian Polymer Laboratories, with almost 20 years experience in the design and manufacture of evaporative light scattering detectors. The Evaporative Light Scattering Detector is the smallest and most flexible ELSD available. Patented gas flow technology gives the 380-LC unrivalled detection capability at ambient temperatures and uniform response across a gradient. This precision instrument operates up to 20 C, with a heated nebulizer that makes it a perfect match for a wide range of applications and LC techniques, including GPC. To detect everything you inject with high sensitivity, the is the ELSD of choice for all high temperature applications. Key Benefits High sensitivity provides superb responses for all compounds, down to low nanogram levels. Unrivalled response to semi-volatile compounds at ambient temperature from patented gas flow technology. Operation up to 20 oc gives improved evaporation of difficult solvents and better response to non-volatile compounds. Low dispersion and high-speed data output rates are the perfect match for Fast LC applications. Superb reproducibility below 2 % gives reliable and accurate results. Full DMSO transparency ensures that responses from early eluting compounds are not hidden. Multi-vendor software control and data acquisition using Varian s Galaxie chromatography data system, and other vendors interfaces, eliminates the need for an analog to digital converter. Fully compatible with the Varian 920-LC analytical HPLC system for enhanced chromatographic performance. Complementary to LC/MS. The smallest ELSD footprint frees up bench space for a less cluttered and safer working environment. Simple set up means that you can be up and running in less than five minutes, straight out of the box.

The is an advanced evaporative light scattering detector from Polymer Laboratories, now a part of Varian, Inc. The 380-LC is ideal for the detection of non-volatile compounds, where temperatures of 00 o C or above are required. The instrument benefits from fast data output rates and extremely low dispersion for fast LC, and delivers a universal response down to the low-nanogram range for truly representative analysis. Reproducibility is less than 2 % for improved consistency of results. Control and digital data collection come as standard for multi-vendor platforms and so there is no need for an analog to digital converter. On-the-fly adjustment of light source intensity can save time during a run. All this in the smallest footprint around. Being complementary to LC/MS, and offering unrivalled flexibility and sensitivity, the is the ELSD of choice for demanding, high temperature applications. Varian s Family of Evaporative Light Scattering Detectors ELS detection is the powerful alternative to RI and UV for all compounds; just inject it and detect it, right down to low nanogram levels. ELSDs provide a universal response independent of the optical properties of the analyte and so there is no loss of important information. You can use Varian s ELSDs for a very wide range of analytical techniques, including HPLC (analytical and preparative), LC/MS, SFC, high throughput screening, GPC/SEC, TREF and GPEC. The range of application areas is equally broad, encompassing pharmaceuticals, nutraceuticals, combinatorial libraries, carbohydrates, lipids, phopspholipids, triglycerides, fatty acids, amino acids, polymers and surfactants. Choose the right Varian ELSD for your needs. HPLC analysis: Non-volatile compounds Semi-volatile compounds Highly volatile compounds Ambient GPC analysis High temperature GPC analysis Varian 385-LC Varian 380-LC PL-ELS 000 yes yes yes yes yes x yes x x yes yes yes x x yes Instrument Qualification - IQ, OQ All Varian Polymer Laboratories ELSD detectors are rigorously tested to a high specification before they are shipped, and detailed IQ, OQ documentation is included with every unit. In addition, our detectors can be incorporated into any HPLC system, and a complete Qualification Workbook is provided to help you. Uniform Mass Response Varian ELSDs are not dependent on a compound s optical properties and so the ELSD provides a more uniform response than UV-VIS, making it the ideal detector for purity analysis or where calibration standards are not available. Column: Polaris C8 5 µm, 50 x 4.6 mm Eluent: Water:Acetonitrile : Flow Rate:.0 ml/min Injection Volume: 0 µl Detection: (neb=30 o C, evap=30 o C, gas=.4 SLM) For non-volatile compounds, where temperatures of 00 C or above are required, the is the instrument of choice. The Varian 385-LC delivers sub-ambient evaporation down to 0 C, providing maximum sensitivity for compounds with significant volatility below 30 C. prednisone dexamethasone UV @ 280 nm The PL-ELS 000 is designed for routine GPC, including high boiling point solvents. For further information on Varian s other ELSDs, see our datasheets Varian 385-LC and PL-ELS 000. 0 2 min 3 4 5 Figure. The Varian ELSD delivers a more uniform mass response than UV from a : mixture. Page 2

Varian ELSDs - Better by Design Evaporative light scattering detection involves a three stage process.. Nebulization utilizing an inert gas stream to form a plume of uniformly sized droplets. 2. Evaporation of the eluent generating a plume of nonvolatile solute particles. 3. Optical detection where the intensity of scattered light is proportional to the mass of solute passing through the optical chamber. Nebulization Efficient nebulization using low gas flow rates is a feature of Varian ELS detectors. Independent nebulizer temperature control and digital gas flow control provide excellent stability and reproducibility. Baseline noise is minimized by the removal of any poorly nebulized eluent via a drain port. Separation of Non-volatile Compounds The is ideal for non-volatile compounds with a weak or no chromophore, such as surfactants, sugars, polymers and lipids, where evaporation temperatures of >80 o C are advantageous. Column: Phenyl hexyl 5 µm, 50 x 4.6 mm Eluent A: 0.5 g/l Ammonium acetate in Water Eluent B: Methanol Gradient: 70-00 % B in 4 min Temperature: 35 C Flow Rate:.0 ml/min Detection: (neb=35 C, evap=60 C, gas=. SLM) Peak Identification. Erucamide 2. Tinuvin 326 3. Irgafos 68 4. Irganox 2 3 4 Evaporation The nebulized stream passes through an independently temperature-controlled evaporator tube where solvent is removed at high temperature, leaving the less volatile solute particles behind. The features patented gas flow control technology with a short evaporator tube that gives an extremely low swept volume for minimal peak dispersion. This provides maximum resolution from the separation, especially important for work with small columns. 0.3 2.6 min 3.9 5.2 6.9 Figure 2. Excellent baseline stability of four polymer additives. Column: C8 5 µm, 250 x 4 mm Eluent A: Acetonitrile Eluent B: Dichloromethane Gradient: 25-45 % B in 45 min, 45-90 % B in 5 min, hold Flow Rate: 5 µl Detection: (neb=60 C, evap=50 C, gas=.6 SLM) diglycerides gas inlet detector eluent inlet triglycerides liquid waste light source Optical detection The solute particles are detected as they pass through the optical chamber. The high power LED and advanced design of the electronics delivers maximum sensitivity. monoglycerides fatty acids UK Patent 0304253.8, US Patent 6/0238744 0 min 30 Figure 3. Separation of a sample of sesame oil. Page 3

Separation of Semi-Volatile Compounds The is also ideal for separating compounds with different degrees of volatility, as shown in Figure 4. With the nebulizer and evaporator running at the same temperature, 50 o C, non-volatile indapamide gives a large response but the other more volatile components give very poor peak response due to loss through evaporation. As the temperatures are reduced to 35 o C, and even more so at ambient, the reveals much improved recovery data of the semi-volatile components, with no deterioration in baseline stability. Peak Identification. Acetanilide 2. Indapamide 3. Ibuprofen 4. Dibutylphthalate Sample: 2 mg/ml in DMSO 50 o C Column: C8, 5 µm, 50 x 4.6 mm Eluent A: 0. % TFA in Water Eluent B: 0. % TFA in Acetonitrile Gradient: 60-90 % in 5 min Flow Rate:.0 ml/min Injection Volume: 20 µl Sample Concentration: mg/ml Detection: Varian ELSD (gas=.6 SLM) DMSO Transparency for High Throughput Screening The vast majority of combinatorial libraries screened by high throughput methods are stored in dimethylsulfoxide (DMSO). UV and mass spectrometry will miss potential drug compounds that have no UV chromophore and so ELSD is commonly used. However, at the low evaporator temperatures required to detect volatile components, the presence of DMSO in the sample can mask the response of early eluting compounds. In the Varian 380- LC, the addition of a carefully controlled stream of gas to the evaporation step enables complete removal of the DMSO to take place without increasing the operating temperature. Column: 5 µm, 50 x 4.6 mm Eluent A: 0. % HFBA in Water Eluent B: 0. % HFBA in Acetonitrile Gradient: 5-30 % B in 0 min, 30-80 % B in 5 min Flow Rate:.0 ml/min Injection Volume: 20 µl Detector: (neb=25 C, evap=25 C, gas as shown) 35 0 C DMSO 2 3 4 ambient gas=.2 SLM 0 min 9 Figure 4. The ability of the to operate at ambient improves data quality. gas=.8 SLM 0 min 5 Figure 5. Increasing gas flow on the provides DMSO transparency. Page 4

Superb RSD Excellent reproducibility below 2 % gives reliable and accurate results - you can have complete confidence in your data. Column: Pursuit C8 5 µm, 50 x 4.6 mm Eluent: Water:Acetonitrile 40:60 Flow Rate:.0 ml/min Injection Volume: 0 µl Detection: (neb=40 C, evap=40 C, gas=.4 SLM) Improved Sensitivity over an RI Detector The ELSD has better baseline stability and sensitivity than an RI detector, making it an extremely suitable choice for carbohydrate analysis. Column: PL Hi-Plex Ca, 250 x 4 mm Eluent: Water Flow Rate: 0.6 ml/min Temperature: 85 o C Injection Volume: 0 µl Detection: (neb=30 C, evap=30 C, gas=.6 SLM) RI Peak Identification. Melezitose 2. Maltose 3. Glucose 4. Mannose 5. Fructose 6. Ribitol (adonitol) 2 3 4 5 6 0 2 3 4 5 min Figure 6. Fifty caffeine injections produce an RSD of.27 %, demonstrating the excellent reproducibility of of the. Sophisticated Galaxie Software for Integrated Control of the System, Data Analysis and Reporting Control and data acquisition using Varian s Galaxie chromatography data system, with options for other multi-vendor control, provides maximum flexibility for the with any HPLC or GPC system. 0 min 23 Figure 7. The ELSD delivers more stable baselines and much improved sensitivity compared to an RI detector. Page 5

Specification Light source Detector LED 480 nm (Class LED Product) Photomultiplier tube digital signal processing Temperature range Evaporator OFF, 30-20 C ( C increments) Nebulizer OFF, 30-90 C ( C increments) Gas requirements Flow rate 0.9 SLM to 3.25 SLM @ 25 C with integrated controlled gas shutoff valve Eluent flow rate Analogue output Digital output Communication Instrument operation PC operation (software) Power requirements Detector status Pressure operating range 0.2-5 ml/min 0 - V FSD 24 bit digital data, 0 or 40 Hz Serial (RS232) Remote start Input Remote A/Z Contact closure 60 00 psi (4-6.7 bar) TTL Graphical vacuum fluorescent display with keypad Real-time control via ELSD Dimension Software Ten predefined methods Galaxie Chromatography Software, standalone control software utilities, Chromeleon Software, ChemStation Control Software, EZChrom Elite Control Software (released later in 2008) 90/20V AC or 220/250V AC 50/60 Hz 2A max Standby, run Size Unpackaged 200 x 450 x 45 mm (w x d x h) Weight Unpackaged 3 kg Safety features Gas shut off valve, vapor and leak detection Ordering Information Product Description Part Number (0 V) PL0890-00 (240 V) PL0890-0240 Varian ELSD Dimension Software PL0890-0375 Varian ELSD Driver for ChemStation PL0890-0380 Galaxie LC Driver Software 850244000 Varian, Inc. www.varianinc.com North America: 800.926.3000, 925.939.2400 Europe The Netherlands: 3.8.67.000 Asia Pacific Australia: 63.9560.733 Latin America Brazil: 55..3238.0400 Other sales offices and dealers throughout the world check our Web site GC LC MS GPC/SEC AA ICP ICP-MS UV-Vis-NIR FT-IR Fluorescence Dissolution NMR MRI FTMS Consumables Data Systems Polymer Laboratories (PL), the PL Logo, Galaxie, Polaris, Pursuit, Chromeleon, EZChrom Elite, Varian and the Varian Logo are trademarks or registered trademarks of Varian, Inc. in the U.S. and other countries. SI-287 03/08 Printed in UK 2008 Varian, Inc.