Increasing the Multiplexing of Protein Quantitation from 6- to 10-Plex with Reporter Ion Isotopologues

Similar documents
Relative quantification using TMT11plex on a modified Q Exactive HF mass spectrometer

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Relative Quantitation of TMT-Labeled Proteomes Focus on Sensitivity and Precision

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Quantitation of TMT-Labeled Peptides Using Higher-Energy Collisional Dissociation on the Velos Pro Ion Trap Mass Spectrometer

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap

Targeted protein quantification

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Improved 6- Plex TMT Quantification Throughput Using a Linear Ion Trap HCD MS 3 Scan Jane M. Liu, 1,2 * Michael J. Sweredoski, 2 Sonja Hess 2 *

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

High-Field Orbitrap Creating new possibilities

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

TOMAHAQ Method Construction

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

A Platform to Identify Endogenous Metabolites Using a Novel High Performance Orbitrap MS and the mzcloud Library

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

MetWorks Metabolite Identification Software

Improving Intact Antibody Characterization by Orbitrap Mass Spectrometry

Carbonyl-Reactive Tandem Mass Tag (TMT) Reagents for Mass Spectrometry-Based Quantitative Glycomics

Self-assembling covalent organic frameworks functionalized. magnetic graphene hydrophilic biocomposite as an ultrasensitive

Mass Spectrometry and Proteomics - Lecture 5 - Matthias Trost Newcastle University

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

A Quadrupole-Orbitrap Hybrid Mass Spectrometer Offers Highest Benchtop Performance for In-Depth Analysis of Complex Proteomes

Peptide Targeted Quantification By High Resolution Mass Spectrometry A Paradigm Shift? Zhiqi Hao Thermo Fisher Scientific San Jose, CA

Quan/Qual Analyses. Unmatched Confidence for. Thermo Scientific Q Exactive Orbitrap LC-MS/MS System. Identify Quantify Confirm

An Evaluation of Various High-Resolution, Accurate-Mass Scan Modes for In Vitro Drug Discovery Screening

Workflow concept. Data goes through the workflow. A Node contains an operation An edge represents data flow The results are brought together in tables

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Fast, Effective XPS Point Analysis of Metal Components

for XPS surface analysis

HR/AM Targeted Peptide Quantitation on a Q Exactive MS: A Unique Combination of High Selectivity, Sensitivity and Throughput

of mass spectrometry

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

NPTEL VIDEO COURSE PROTEOMICS PROF. SANJEEVA SRIVASTAVA

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Key Words Q Exactive Focus, Orbitrap, veterinary drugs, small molecule HRAM quantitation, small molecule HRAM screening, UHPLC, vdia

Reagents. Affinity Tag (Biotin) Acid Cleavage Site. Figure 1. Cleavable ICAT Reagent Structure.

Quantitation of a target protein in crude samples using targeted peptide quantification by Mass Spectrometry

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

Introduction to Fourier Transform Infrared Spectroscopy

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Fast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Achieving robust, accurate TMT quantitation efficiency with Tribrid technology

High-Resolution Accurate-Mass (HRAM) Phthalate Screening using Direct Analysis in Real Time (DART) Ambient Ionization

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites

The Power of LC MALDI: Identification of Proteins by LC MALDI MS/MS Using the Applied Biosystems 4700 Proteomics Analyzer with TOF/TOF Optics

Monitoring Protein PEGylation with Ion Exchange Chromatography

Designed for Accuracy. Innovation with Integrity. High resolution quantitative proteomics LC-MS

Direct Analysis using Paper-Spray Mass Spectrometry: Method Development for the Rapid Screening of Drugs of Abuse for Forensic Toxicology

Methods for proteome analysis of obesity (Adipose tissue)

Amine specific Labeling Reagents for Multiplexed Relative and Absolute Protein Quantitation

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

High-Throughput LC-MS/MS Quantification of Estrone (E1) and Estradiol (E2) in Human Blood Plasma/Serum for Clinical Research Purposes

Crosslinking mass spectrometry (XL-MS) goes mainstream

Peptide Labeling with Isobaric Tags Yields Higher Identification Rates Using itraq 4-Plex Compared to TMT 6-Plex and itraq 8-Plex on LTQ Orbitrap

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Charles Yang, Dipankar Ghosh, Jonathan Beck Thermo Fisher Scientific, San Jose, CA, USA

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM

Enhancement of Linearity and Response in Charged Aerosol Detection

Detection of Mycotoxins in Corn Meal Extract Using Automated Online Sample Preparation with Liquid Chromatography-Tandem Mass Spectrometry

Analysis of Labeled and Non-Labeled Proteomic Data Using Progenesis QI for Proteomics

Proteome-wide label-free quantification with MaxQuant. Jürgen Cox Max Planck Institute of Biochemistry July 2011

Q Exactive TM : A True Qual-Quan HR/AM Mass Spectrometer for Routine Proteomics Applications. Yi Zhang, Ph.D. ThermoFisher Scientific

Quantitative and Qualitative Confirmation of Pesticides in Beet Extract Using a Hybrid Quadrupole-Orbitrap Mass Spectrometer

Introduction to Fourier Transform Infrared Spectroscopy

Targeted Proteomics Environment

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

HILIC Method Development in a Few Simple Steps

MS Based Proteomics: Recent Case Studies Using Advanced Instrumentation

Computational Methods for Mass Spectrometry Proteomics

SILAC and TMT. IDeA National Resource for Proteomics Workshop for Graduate Students and Post-docs Renny Lan 5/18/2017

HOWTO, example workflow and data files. (Version )

Tandem mass spectra were extracted from the Xcalibur data system format. (.RAW) and charge state assignment was performed using in house software

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Advanced Fragmentation Techniques for BioPharma Characterization

DIA-Umpire: comprehensive computational framework for data independent acquisition proteomics

Workshop: SILAC and Alternative Labeling Strategies in Quantitative Proteomics

High-Resolution Enabled 12-Plex DiLeu Isobaric Tags for Quantitative Proteomics

Rapid Distinction of Leucine and Isoleucine in Monoclonal Antibodies Using Nanoflow. LCMS n. Discovery Attribute Sciences

Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

protein quantitation

TMT10plex Mass Tag Labeling Kits and Reagents

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Screening Method for 30 Pesticides in Green Tea Extract Using Automated Online Sample Preparation with LC-MS/MS

Improved Precision of itraq and TMT Quantification by an Axial Extraction Field in an Orbitrap HCD Cell

Transcription:

Increasing the Multiplexing of Protein Quantitation from 6- to 1-Plex with Reporter Ion Isotopologues Rosa Viner, 1 Ryan Bomgarden, 2 Michael Blank, 1 John Rogers 2 1 Thermo Fisher Scientific, San Jose, CA, USA; 2 Thermo Fisher Scientific, Rockford, IL, USA

Overview Purpose: To develop Tandem Mass Tag (TMT ) 1-plex reagents by combining current Thermo Scientific TMTsixplex reagents with four TMT6 reagent isotope variants on multiple high-resolution mass spectrometry platforms. Methods: HeLa cell lysates and bovine serum albumin (BSA) digests were labeled with Thermo Scientific TMT1plex reagents. Aliquots from six, eight or all ten channels were mixed in different ratios and analyzed on three different Thermo Scientific Orbitrap -based instruments. Results: We have extended the multiplexing capabilities of TMT reagents from 6 to 1 without increasing the size or structure of the tag by utilizing the 6 mda mass difference between 13 C and 15 N isotopes of the mass tag reporter ions. Mass spectrometry analysis on three different Orbitrap-based instruments using FT MS2/MS3 shows no negative effect on the number of protein identifications or quality of quantification in a complex digest by increasing sample multiplexing from 6 to 1. Introduction Amine-reactive isobaric tags (TMT or itraq ) enable concurrent identification and multiplexed quantification of proteins in different samples using tandem mass spectrometry. Increasing the number of isobaric tag-labeled samples that can be compared in a single experiment is highly desirable. However, it has been reported that increasing multiplexing by using larger tagging molecules significantly decreases the number of identified and quantified proteins and peptides. 1 Here, we demonstrate that 1-plex multiplexing can be achieved with high resolution mass spectrometry utilizing the 6 mda mass difference between 15 N and 13 C stable isotopes by combining current TMTsixplex reagents with four TMT6 isotope variants without loss of protein identifications and quality of quantification in a complex digest. Methods Sample Preparation HeLa cell lysates (Thermo Scientific, Rockford, IL) and bovine serum albumin (BSA, Sigma, St.Louis, MO) were reduced, alkylated and digested with LysC and/or trypsin. Samples were then labeled with TMT1plex reagents (Figure 1) according to manufacturerʼs instructions. Aliquots from six, eight or all ten channels were mixed in equimolar ratios. To assess the impact of peptide co-isolation on quantification, HeLa digest labeled with Thermo Scientific TMT8plex reagents was spiked with BSA digest labeled with TMT1plex reagents mixed at fixed ratios (16:8:4:2:1:1:2:4:8:16). LC-MS A Thermo Scientific EASY-nLC 1 HPLC system and Thermo Scientific EASY- Spray source with Thermo Scientific Acclaim PepMap 1 2 cm x 75 μm trap column and Thermo Scientific EASY-Spray PepMap RSLC C18 25 or 5 cm x 75 μm ID column were used to separate peptides with a 5-25% acetonitrile gradient in.1% formic acid over 6 min for single proteins or 21 min at a flow rate of 3 nl/min for HeLa digest. Samples (5 ng injections) were analyzed on Thermo Scientific Q Exactive, Orbitrap Elite and Orbitrap Fusion Tribrid mass spectrometers using FT HCD MS2 or synchronous precursor selection (SPS) MS3 fragmentations (Orbitrap Fusion MS). Data Analysis Thermo Scientific Proteome Discoverer software version 1.4 was used to search MS/MS spectra against the Swiss-Prot human+bsa database using SEQUEST HT search engine. Static modifications included carbamidomethylation (C) and TMTsixplex (N-terminal, K). Dynamic modifications included methionine oxidation and deamidation (N,Q). Resulting peptide hits were filtered for maximum 1% FDR using the Percolator algorithm. 2 The TMT1plex quantification method within Proteome Discoverer software was used to calculate the reporter ratios with mass tolerance ±1 ppm without applying the isotopic correction factors. Only peptide spectra containing all reporter ions were designated as quantifiable spectra. A protein ratio was expressed as a median value of the ratios for all quantifiable spectra of the peptides pertaining to that protein. For spiked in BSA experiments with data originating from the MS2 HCD method, a precursor co-isolation filter of 25% was applied. This eliminated peptides where contributions from co-eluting, nearly isobaric peptide species could interfere significantly with the reporter ion signals coming from the peptide of interest. For data sets obtained with the MS3-based method which contained both MS2 and MS3 spectra, CID(MS2) spectra were used for peptide identification and HCD(MS3) that contained reporter ions were used for quantification 3. 2 Increasing the Multiplexing of Protein Quantitation from 6- to 1-Plex with Reporter Ion Isotopologues

Results Comparison of unlabeled to TMT6-, 8- or 1-plex labeled HeLa digests. We have extended the previously reported 4,5 TMT8plex set of reagents to a 1plex set for multiplex peptide quantitation without increasing the size or altering the structure of the tag (Figure 1). The TMT1plex reagents utilize the 6 mda mass difference between 13 C and 15 N isotopes which are measured by high-resolution LC-MS n. In order to accurately quantify all ten channels, all reporter ions need to be baseline resolved. We determined the minimum resolution to separate all ten channels for an MSn resolution to be 35K at m/z 2 (~5K at m/z 12) as shown in Figure 2. At this resolution, an accurate ratio calculation for the all reporter ions can be achieved using a mass tolerance window of up to 1 ppm without applying isotope correction factors. FIGURE 1. Thermo Scientific TMT1plex Reagents structures and reporter ion mass for TMT6plex tags (blue), TMT8plex (green) and TMT1plex (orange). TMT1-126 126.1277261 TMT1-127N TMT1-127C 127.124761 127.13189 TMT1-128N TMT1-128C 128.1281158 128.1344357 TMT1-129N TMT1-129C 129.131476 129.137795 TMT1-13N TMT1-13C 13.1348254 131.138182 TMT1-131 13.1411453 ETD cleavage site HCD cleavage site FIGURE 2. Optimal resolution settings to resolve isotope variants. Q Exactive MS Transient 128 ms RP 35K@m/z 2 OT Elite MS Transient 96 ms RP 3K@m/z 4 OT Fusion MS Transient 128 ms RP 6K@m/z 2 To benchmark the performance of new higher multiplexing reagents, we prepared a Lys-C, trypsin HeLa cell digest and analyzed unlabeled and TMT-labeled samples (equimolar 6-, 8- or 1-plex) on three different Orbitrap-based instruments. Acquisition methods used for Orbitrap Elite, Q Exactive and Orbitrap Fusion MS are summarized in Table 1. Compared to unlabeled HeLa digest, HCD MS2 of TMT6plex-labeled samples consistently identified at least 8% as many protein groups, with no loss in identified proteins/peptides with 8plex and 1plex samples compared to TMT6plexlabeled samples, depending on the instrument (Figure 3). All three multiplexed samples consistently quantified more than 98% of identified peptides and proteins compared to unlabeled samples. Thermo Scientific Poster Note PN ASMS13_W617_RViner_e 6/13S 3

TABLE 1. Instrument settings used for TMT experiments. FT MS1 Parameter Q Exactive MS Orbitrap Elite MS Orbitrap Fusion MS Resolution settings (FWHM at m/z 2) 14, 12, 12, Target value 3e6 1e6 2e5 Injection time 12 12 5 FT MS2 HCD HCD HCD Resolution settings (FWHM at m/z 2) 35, 3, 6, Target value 1e5 5e4 1e5 Injection time 25 25 12 Isolation width (Da) 2 2 2 Top N 1 15 3 sec FIGURE 3. Identification and quantification results for TMT experiments on three Orbitrap instruments. Number of total peptide identifications (A) and protein groups (B) are shown at 1% FDR for 5ng HeLa digest. The number of quantifiable proteins and peptides is also shown. Results represent an average of two replicate runs for each sample. A. 4 35 3 Peptides 25 2 15 1 5 Total Quantified Total Quantified Total Quantified Q Exactive MS Orbitrap OT Elite MS MS Orbitrap OT Fusion Fusion MS MS Unlabeled TMT6 TMT8 TMT1 B. Protein groups 45 4 35 3 25 2 15 1 5 Total Quantified Total Quantified Total Quantified Q Exactive MS Orbitrap OT Elite Elite MS MS Orbitrap OT Fusion Fusion MS MS Unlabeled TMT6 TMT8 TMT1 4 Increasing the Multiplexing of Protein Quantitation from 6- to 1-Plex with Reporter Ion Isotopologues

Quantitative precision and accuracy. Two main factors contribute to decreased quantitative accuracy when using isobaric tags: 1) interference in reporter ion mass regions and 2) interference from co-isolation of precursor ions. Interference from background ions in the reporter region can be addressed by scanning with high resolution (Figure 2). Co-isolation interference has been recently addressed by using a multi-notch (SPS)MS3 experiment on an LTQ Orbitrap Velos or Orbitrap Elite instrument 4,6 and by combining a narrow precursor isolation width and fragmentation at the apex of the LC. 7 FIGURE 4. Synchronous Precursor Selection MS3 TMT workflow for accurate quantification. Precursor MS2 IT CID Multi-notch isolation 5 fragments selected FTMS 3 HCD of selected notches Reporter ions FIGURE 5. Accuracy and precision of TMT1 BSA quantitation spiked into TMT8 HeLa matrix using MS2 vs MS3 methods on Orbitrap Fusion MS. Expected (A) and observed (B) ratios normalized to 126 reporter ion intensity. Results represent an average of two replicate runs for each sample. A. B. Expected BSA peptide reporter Ion ratios Observed BSA peptide reporter ion ratios 2 18 16 14 12 1 8 6 4 2 2 18 16 14 12 1 8 6 4 2 BSA (16:8:4:2:1:1:2:4:8:16) + HeLa (1:1:1::1:1:1::1:1) BSA alone TMT 1 BSA, 5 fmol:129:64:32:16:8:8:16:32:64:129 TMT 8 HeLa, 5 ng 126 127N 127C 128N 128C 129N 129C 13N 13C 131 BSA+ HeLa SPS MS3 BSA+ HeLa MS2 ( 1.2 amu isolation) 126 127N 127C 128N 128C 129N 129C 13N 13C 131 Thermo Scientific Poster Note PN ASMS13_W617_RViner_e 6/13S 5

FIGURE 6. Identification and quantification of TMT1-labeled BSA digest spiked into TMT8-labeled HeLa using MS2 vs MS3 methods on the Orbitrap Fusion MS. Number of HeLa proteins (A) and BSA peptide (B) identifications are shown at 1% FDR. Results represent an average of two replicate runs for each sample. A. B. Protein groups 45 4 35 3 25 2 15 1 HeLa MS2 MS3 Peptides 4 35 3 25 2 15 1 BSA MS2 MS3 5 5 Total Quantified Sequence coverage Total Quantified To assess the impact of peptide co-isolation on quantification, TMT8plex-labeled HeLa samples were equally mixed (1:1:1:1:1:1:1:1) and spiked with BSA labeled with TMT1plex reagents mixed at different ratios (16:8:4:2:1:1:2:4:8:16). The sample (5 fmol BSA + 5 ng HeLa digest) was then analyzed on an Orbitrap Fusion MS using narrow precursor isolation (1.2 amu) by HCD MS2 or a novel SPS MS3 fragmentation/quantification method (Figures 4 & 5). 4 The SPS( multi-notch) MS3 method significantly improved quantitative accuracy for the spiked BSA peptide digest as shown in Figure 5B. The percent of proteins quantified employing the MS3 approach was over 95% with less than 25% loss in identified proteins due to the improved scan rate of the Orbitrap Fusion MS (Figure 6). These results significantly outperform previously reported single notch MS3 acquisition methods for both number of quantified proteins and quantitative accuracy. 3,6 Conclusion Mass spectrometry analysis on three different Orbitrap-based instruments shows no negative effect on number of protein identifications or quality of quantification in complex digest by increasing TMT multiplexing from 6 to 1. Higher-resolution analysis, at least 35K@ m/z 2, is required for the accurate TMT1plex reagent reporter ion measurements. Precursor co-isolation effect in complex samples can be addressed to a large extent by relying on the reporter ion intensities extracted from MS3 spectra. The Orbitrap Fusion MS demonstrated significant improvements in the number of peptide identifications and quantifiable proteins using TMT reagents compared to the previous series of instruments. A novel FT MS3 Synchronous Precursor Selection method implemented on the Orbitrap Fusion MS showed only ~25% loss of identified proteins and an excellent 95% quantitation rate with significantly improved quantification accuracy for BSA digest peptides spiked into a complex proteome matrix. References 1. Pichler, P.; Kocher, T.; Holzmann, J.; Mazanek, M.; Taus, T.; Ammerer, G.; Mechtler, K. Anal. Chem. 21, 82: 6549 6558. 2. Kall, L. Canterbury, J, Weston, J., Noble, W.S., MacCoss, M. Nature Meth. 27, 4: 923-925. 3. Viner, R.; Scigelova, M.; Zeller, M.; Oppermann, M.; Moehring, T.; Zabrouskov, V. Thermo Fisher Scientific Application Note #566, 212 4. McAlister, G., Huttlin, E.L.; Haas, W.; Ting, L.; Jedrychowski, M.P.; Rogers, J.C.; Kuhn, K.; Pike, I.; Grothe, R.A,; Blethrow, J.D.; Gygi, S.P. Anal Chem. 212. 84: 7469-7478. 5. Werner, T., Becher, I.; Sweetman,G.; Doce,C.; Savitski, M.; Bantscheff, M. Anal Chem. 212. 84: 7188-7194. 6. Ting, L.; Rad, R.; Gygi, S. P.; Haas, W., Nature Methods 211, 8, 937-94. 7. Savitski, M. M.; Sweetman, G.; Askenazi, M.; Marto, J. A.; Lang, M.; Zinn, N.; Bantscheff, M. Anal. Chem. 211, 83: 8959 8967. 6 Increasing the Multiplexing of Protein Quantitation from 6- to 1-Plex with Reporter Ion Isotopologues

www.thermoscientific.com 213 Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization. itraq is a trademark of Applera Corporation. Tandem Mass Tag, TMT are trademarks of Proteome Sciences plc. SEQUEST is a registered trademark of the University of Washington. Mascot is a trademark of Matrix Science, Ltd. Swiss-Prot is a registered trademark of Institute Suisse de Bioinformatique (Sib) Foundation Switzerland. All other trademarks are the property of Thermo Fisher Scientific, Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Thermo Fisher Scientific, San Jose, CA USA is ISO 91:28 Certified. Africa-Other +27 11 57 184 Australia +61 3 9757 43 Austria +43 1 333 5 34 Belgium +32 53 73 42 41 Canada +1 8 53 8447 China +86 1 8419 3588 Denmark +45 7 23 62 6 Europe-Other +43 1 333 5 34 Finland/Norway/Sweden +46 8 556 468 France +33 1 6 92 48 Germany +49 613 48 114 India +91 22 6742 9434 Italy +39 2 95 591 Japan +81 45 453 91 Latin America +1 561 688 87 Middle East +43 1 333 5 34 Netherlands +31 76 579 55 55 New Zealand +64 9 98 67 Russia/CIS +43 1 333 5 34 South Africa +27 11 57 184 Spain +34 914 845 965 Switzerland +41 61 716 77 UK +44 1442 233555 USA +1 8 532 4752 ASMS13_W617_RViner _E 6/13S