DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

Similar documents
Oscillation Flow Meter for Gases

Thermal Mass Flow Meter for Gases

DVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids. Range from liquids, acids and caustic solutions:

Industrial Resistance Thermometers according to DIN Model MWD

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids

Full Metal Variable Area Flow Meter and Counter

Infrared Hand-Held Thermometers

Ultrasonic Gas Flow Meter

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Operating Instructions for Digital Manometer. Model: MAN-SD

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

Mass Flow Meter and Controller

Infrared Hand-Held Thermometers

Electromagnetic Flowmeter

ED 701 General Industry Pressure Transmitter

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

2017 Source of Foreign Income Earned By Fund

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Pressure Measurement Single-range transmitters for general applications

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

Gear Wheel Flowmeter for viscous liquids Model DZR. (option 3):

Canadian Imports of Honey

Volumetric Flow Measurement

VersaFlow Ultrasonic clamp-on Flowmeter Specifications

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Facts and figures MULTILIFT SELECT 15

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

ISEmax CAM40/CAS40. Technical Information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Heat Meter WR 200-D. 2 temperature inputs for Pt100 in four-wire circuit. Exact calculation of the heat parameters according IAPWS-IF97

Direct-operated 2/2-way solenoid valves Type EV210B

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

Technical specification FLUXUS F502TE

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.

close to performances of the turbine gas meters designed for custody transfer measurements.

Direct-operated 2/2-way compact solenoid valves Type EV210A

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

BSH Description. 2. Features. 3. Applications. 4. Pinning information. N-channel enhancement mode field-effect transistor

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Cyclone Click to go to the page. Cyclone

Integral V-Cone Flowmeter VD series

Solenoid valves 2/2-way direct-operated type EV210A

Pressure transmitters for industrial applications MBS 32 and MBS 33

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

MODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

Reflex-Radar BM 100 A

Coriolis Mass Flow Measurement System promass 60 (HART)

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter

HiPace 1200, with TC 1200, DN 200 CF-F

FXP DATASHEET JUNHO 2013

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

Pressure Transmitter ED 701

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

PAA-ANALYZERS PRINCIPLE OF OPERATION

HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter

PRODUCT CATALOGUE PREssURE switch

Solenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

tekcor TKC Multivariable Coriolis Flow Sensors

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

PHT4NQ10LT. 1. Description. 2. Features. 3. Applications. 4. Pinning information. N-channel enhancement mode field-effect transistor

Fitting PS P - B - R2

SVH with HYDROVAR (HVL range)

Bilateral Labour Agreements, 2004

Working pressure. 420 bar. Style T. Style B. Style D Style V Style Z. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.

Cooling Water Flow Regulator

04 June Dim A W V Total. Total Laser Met

READY TO SCRAP: HOW MANY VESSELS AT DEMOLITION VALUE?

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

FLOW SENSOR FOR LIQUID MEDIA Serie 210

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

VK2 volume flow controller Overview

Field mounted Temperature Transmitter TF212/TF212-Ex

Transcription:

Oscillation Flowmeter for gases measuring monitoring analysing DOG1/3 Measuring ranges: 0.2 20... 200 20000 m 3 /h air p max : PN 40; t max : 120 C Connection: flange DN 25... DN 400 Material: cast iron, steel or stainless steel Accuracy: ±1.5 % of measured value No moving parts Longterm stability S5 1/09 2014 KOBOLD companies worldwide: ARGENTINA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLoMBIA, CZECHIA, DOMINICAN REPUBLIC, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, ROMANIA, SINGAPORE, SOUTH KOREA, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring 2224 D65719 Hofheim/Ts. Head Office: +49(0)6192 2990 +49(0)6192 23398 info.de@kobold.com 1

Oscillation Flowmeter Model DOG1, DOG3 Description The KOBOLD flowmeter DOG1 and DOG3 are used for noncontact flow measurement of gases. The medium flows through an orifice in a tube. Bypass bores are located at the sides. The dynamic pressure at the orifice causes part of the gas volumetric flow to flow into the bypass. The division ratio remains constant over the whole measuring range. The bypass channel contains the Oscillator the measuring cell itself. When the gas flows through the measuring cell, a gas column oscillates in a Ushaped channel mounted to the left and right. This oscillation frequency is proportional to the flow velocity and thus to the total volume flow. The oscillation frequency is sensed with a hot wire sensor. An electrical alternating signal is generated that is displayed in the seriesconnected. Application The inner, connected flow channels are generously dimensioned. The constant changes of direction of the flow in the channels have a selfcleaning effect. The devices are therefore extremely dirt resistant and have no consumables. The mounting position can be chosen at will. When condensate forms in the gas, the horizontal mounting position with the sensing element pointing upwards is recommended. The gas flow velocity anywhere in the pipework upstream of the flowmeter should not exceed the sound velocity. Pressure drops above critical and pulsating streams must be avoided. The recommended inlet pipe section is 10xDN and the outlet pipe section 5xDN. Areas of Application Compressed air Natural gas, biogas, fermentation gas Propane Hydrogen gas Nitrogen Argon Technical Data Measuring accuracy: ±1.5% of meas. value (at Qt 100%*) ±5% of measured value (at 1%Qt *) *The lower limit Q t depends on the density Qt= 8% at density 1 kg/m 3 Qt= 4% at density 2 kg/m 3 Qt= 2% at density 4 kg/m 3 Qt= 1% at density 8 kg/m 3 Repeatability: 0.1% of measured value Temperature span: 40...+120 C 40...+60 C (ExVersion) option 40... +100 C (Exversion) Ambient temperature: max. 80 C 25...+60 C (ExVersion) Operating pressure: DOG11/12.., DOG31/32..: PN 16 DOG12/13.., DOG32/33..: PN 40 Span: DOG1..: 1:100 DOG3..: 1: 50 Sensor: hotwire, RDC Protection: IP 65 Materials Housing: DOG11..: cast iron 0.6025 DOG13..: steel 1.0345 DOG33..: steel 1.0715 DOG12/32..: st. steel 1.4404/1.4436 Orifice: stainless steel 1.4436 Sensing element: polyphenylene sulfide (PPS) Sensor: platinum Gaskets: silicone, nitrile or FPM Electronics DOG X Electrical connection: conduit thread Protection: IP 65 Display: 4digit LCD display, counter Power supply: 230 V AC 10%, +12%/ 48 62 Hz Input: hot wire sensor Pulse output 1: 12 V DC, max.100 ma, open collector Pulse output 2: potentialfree contact decadic 250 V AC,max. 3 A Analogue output: 4... 20 ma max. 500 Ω Ambient temperature: 0... +50 C Permissible distance: max. 50 m to DOG1, DOG3 max. 1000 m to DOG2 Connection cable: minimum 0.5 mm 2, screening recommended ExVersion: ` II 1G EEx ia IIC T4 2 1/09 2014

Oscillation Flowmeter Model DOG1, DOG3 1/09 2014 Electronics DOG W/Z/Q for DOGflowmeters and all meters with pulse detection by means of a proximity switch (model NAMUR) Electrical connection: terminal Protection: IP 65 Mounting type: wall mounting Display: 2 x digits LCD with backlit display line 1: flow rate (Nm 3 /h, Nm 3 /min, m 3 /h, m 3 /min, kg/h, kg/min), 7 digits, floating decimal point current pressure (barg), only available for option Q Default pressure for all models line 2: totaliser (Nm 3, m 3, kg), 12 digits, floating decimal point current temperature ( C, F, K), only available for option Q Default temperature for all models Engineering units are configured at the factory and should thus be mentioned in the P. O. while ordering. DOG W Display indication: flow rate/accumulated volume, resettable Output: pulse, 1224 V open collector or 12 V DC active DOG Z Display indication: Output: DOG Q Flow calculator input signal from: flow rate/accumulated volume, resettable 1/ pulse, 1224 V open collector or 12 V DC active 2/ 4... 20 ma, galvanic isolated (a) gas flowmeter pulse, (b) pressure transmitter 4...20 ma (1x bar g), (c) temperature sensor Pt 100 Builtin calculation function for PT correction Display indication of all process parameters Output signal: (i) pulse, resettable, for selected units, e.g. m 3, Nm 3 or kg (ii) 4...20 ma, galvanic isolated, with selected volume or mass units, such as m 3 /h, Nm 3 /h or kg/h All models have a builtin linearisation function of the flow meter signal Input signal (pulse train) Flowmeter DOG: directly or Proximity switch: max 8 V DC (high level) Speed range: 0...500 Hz Over voltage protection: 24 V Input signal (analogue) Temperature sensor: Pt 100 (four wire lead comp.) Pressure transducer: 4...20 ma Basic measuring resolution: 12 bit Accuracy: 0.05 % at 20 C Update rate: 1 update/sec Reverse polarity: no ill effects Over current limit: 12 V DC, 100 ma (fault protected) Output signal (i) pulse train assignable to uncompensated or PT compensated volume total, or mass total 12 V DC active (voltage pulse) alt. passive (open collector, max 24 V DC load) pulse width adjustable (ii) isolated analogue output signal 4...20 ma assignable to uncompensated or PT compensated flow rate Adjustable damping: time constant 0.54.0 sec Accuracy: 0.1% of full scale at 20 C Update rate: 5 updates/sec Maximum load: 500 Ω 3

Oscillation Flowmeter Model DOG1, DOG3 Order Details for DOG1 with flange (Example: DOG1101L F25N S Q) Measuring range air [m³/h] 0.35... 35 0.7... 70 0.6... 60 1.0... 100 0.9... 90 1.8... 180 1.1... 110 2.5... 250 0.9... 90 1.7... 170 3.5... 350 1.4... 140 4.0... 400 7.0... 700 2.7... 270 6.5... 650 9.0... 900 4... 400 8... 800 15... 1500 6... 600 12... 1200 30... 3000 12... 1200 25... 2500 60... 6000 20... 2000 40... 4000 75... 7500 30... 3000 50... 5000 130... 13000 40... 4000 70... 7000 140... 14000 50... 5000 100... 10000 160... 16000 Material cast iron DOG1101L.. DOG1102L.. DOG1103L.. DOG1107L.. DOG1108L.. DOG1109L.. DOG1110L.. DOG1111L.. DOG1112L.. DOG1116L.. DOG1117L.. DOG1118L.. DOG1119L.. DOG1120L.. DOG1121L.. Model Connection flange Gasket Remote Material Material Standard PN 16 Special PN 40 steel st. steel only GG, VA only steel, st. steel DOG1304L.. DOG1305L.. DOG1306L.. DOG1313L.. DOG1314L.. DOG1315L.. DOG1322L.. DOG1323L.. DOG1324L.. DOG1325L.. DOG1326L.. DOG1327L.. DOG1328L.. DOG1329L.. DOG1330L.. DOG1331L.. DOG1332L.. DOG1333L.. DOG1334L.. DOG1335L.. DOG1336L.. DOG1337L.. DOG1338L.. DOG1339L.. DOG1340L.. DOG1341L.. DOG1342L.. DOG1201L.. DOG1202L.. DOG1203L.. DOG1207L.. DOG1208L.. DOG1209L.. DOG1210L.. DOG1211L.. DOG1212L.. DOG1213L.. DOG1214L.. DOG1215L.. DOG1216L.. DOG1217L.. DOG1218L.. DOG1219L.. DOG1220L.. DOG1221L.. DOG1222L.. DOG1223L.. DOG1224L.. DOG1225L.. DOG1226L.. DOG1227L.. DOG1228L.. DOG1229L.. DOG1230L.. DOG1231L.. DOG1232L.. DOG1233L.. F25N = DN 25 F25S = DN 25 F32N = DN 32 F32S = DN 32 F40N = DN 40 F40S = DN 40 F50N = DN 50 F50S = DN 50 F65N = DN 65 F65S = DN 65 F80N = DN 80 F80S = DN 80 F1HN = DN 100 F1HS = DN 100 F1ZN = DN 125 F1ZS = DN 125 F1FN = DN 150 F1FS = DN 150 F2HN = DN 200 F2HS = DN 200 F2FN = DN 250 F2FS = DN 250* F3HN = DN 300 F3HS = DN 300 F3FN = DN 350 F4HN = DN 400 * not for DOG12 (stainless steel) ** Engineering units are configured at the factory and should thus be mentioned in the P.O. while ordering Please state the exact operating conditions (gas types, flow volume, pressure, temperature, installation position etc.) when ordering. S = silicone N = nitrile V = FPM with external...e RDC input, without display, with EX protection, with analogue and pulse output...x RDC input, with display for instantaneous value and total, with EX protection, with analogue and pulse output...w** resettable pulse output...z** resettable, pulse output, 4...20 ma...q** flow calculator, input: pulse, Pt 100, 4...20 ma (pressure) output: pulse and 4...20 ma 4 1/09 2014

Oscillation Flowmeter Model DOG1, DOG3 Order Details for DOG3 with flange (Example: DOG3301L F25N S Q) Measuring range air [m³/h] 0.4... 20 0.7... 35 1.4... 70 0.4... 20 1.8... 90 3.5... 180 0.4... 20 2.2... 105 5... 250 1.8... 90 3.5... 170 7... 350 2.8... 140 8... 400 14... 700 5.4... 270 13... 650 18... 900 8... 400 16... 800 30... 1500 12... 600 25... 1250 60... 3000 24... 1200 50... 2500 30... 3000 40... 2000 80... 4000 150... 7500 60... 3000 100... 5000 260... 13000 80... 4000 140... 7000 280... 14000 100... 5000 200... 10000 320... 16000 Material steel DOG3301L.. DOG3302L.. DOG3303L.. DOG3307L.. DOG3308L.. DOG3309L.. DOG3310L.. DOG3311L.. DOG3312L.. DOG3313L.. DOG3314L.. DOG3315L.. DOG3316L.. DOG3317L.. DOG3318L.. DOG3319L.. DOG3320L.. DOG3321L.. DOG3322L.. DOG3323L.. DOG3324L.. DOG3325L.. DOG3326L.. DOG3327L.. DOG3328L.. DOG3329L.. DOG3330L.. DOG3331L.. DOG3332L.. DOG3333L.. DOG3334L.. DOG3335L.. DOG3336L.. DOG3337L.. DOG3338L.. DOG3339L.. DOG3340L.. DOG3341L.. DOG3342L.. Model Connection flange Gasket Remote Material Standard PN 16 Special PN 40 st. steel only GG, VA only steel, st. steel DOG3201L.. DOG3202L.. DOG3203L.. DOG3207L.. DOG3208L.. DOG3209L.. DOG3210L.. DOG3211L.. DOG3212L.. DOG3213L.. DOG3214L.. DOG3215L.. DOG3216L.. DOG3217L.. DOG3218L.. DOG3219L.. DOG3220L.. DOG3221L.. DOG3222L.. DOG3223L.. DOG3224L.. DOG3225L.. DOG3226L.. DOG3227L.. DOG3228L.. DOG3229L.. DOG3230L.. DOG3231L.. DOG3232L.. DOG3233L.. DOG3234L.. DOG3235L.. DOG3236L.. DOG3237L.. DOG3238L.. DOG3239L.. DOG3240L.. DOG3241L.. DOG3242L.. F25N = DN 25 F25S = DN 25 F40N = DN 40 F40S = DN 40 F50N = DN 50 F50S = DN 50 F65N = DN 65 F65S = DN 65 F80N = DN 80 F80S = DN 80 F1HN = DN 100 F1HS = DN 100 F1ZN = DN 125 F1ZS = DN 125 F1FN = DN 150 F1FS = DN 150 F2HN = DN 200 F2HS = DN 200 F2FN = DN 250 F2FS = DN 250 F3HN = DN 300 F3HS = DN 300 F3FN = DN 350 F3FS = DN 350 F4HN = DN 400 F4HS = DN 400 * Engineering units are configured at the factory and should thus be mentioned in the P.O. while ordering S = silicone N = nitrile V = FPM with external...x RDC input, with display for instantaneous value and total, with EX protection, with analogue and pulse output...w* resettable pulse output...z* resettable, pulse output, 4...20 ma...q* flow calculator, input: pulse, Pt 100, 4...20 ma (pressure) outputs: pulse and 4...20 ma Please state the exact operating conditions (gas types, flow volume, pressure, temperature, installation position etc.) when ordering. Order Details Spare Sensor for gas flowmeter max. medium temperature: +60 C Order Code: ERSDOG5193 1/09 2014 5

Oscillation Flowmeter Model DOG1, DOG3 Pressure Loss/Flow The diagram applies for gases with a density of air at NPT (0 C and 1000 mbar). The pressure loss is always proportional to the density of the gas. For example, the pressure loss doubles at 100% higher operating pressure. Calculating the Actual Density The actual density can be calculated with the following formula: D = D 0 *P *T 0 T D 0 = density at 1 bar abs. and 0 C (= 273 K) T = temperature in K (= C + 273 for example 20 C = 273 + 20 = 293 K) T 0 = 273 K P = operating pressure in bar (absolute pressure) Dimensions and Weight DOG1 L H Calculating the Norm Flow P 273 Q N = Q 1.013 T Q N = norm flow at 1.013 bar abs. and 0 C Q = operating flow P = operating pressure in bar (absolute pressure) T = operating temperature in K D Dh Ds DN L D Dh Ds 6 Number of holes H H with AVF 25 300 115 85 14 4 130 165 10 32 300 140 100 18 4 140 175 11 40 300 150 110 18 4 140 175 12 50 300 165 125 18 4 145 180 13 65 300 185 145 18 4 155 190 14 80 300 200 160 18 8 160 195 20 100 300 220 180 18 8 200 235 23 125 300 250 210 18 8 230 265 20 150 350 285 240 22 8 255 290 26 200 350 340 295 22 12 280 315 36 250 450 405 355 26 12 305 340 53 300 500 460 410 26 12 330 365 70 350 500 520 470 26 16 360 395 83 400 500 580 525 30 16 380 415 90 Weight [kg] 1/09 2014

Oscillation Flowmeter Model DOG1, DOG3 Dimensions and Weight DOG3 Dimensions of Electronics DOG E/X 65 82 193 135 DN 50 65 DN D Weight [kg] 25 65 10 32 65 11 40 65 12 50 65 13 65 65 14 80 65 20 100 65 23 125 65 20 150 65 28 200 65 36 250 65 53 300 65 70 350 65 90 400 65 120 Dimensions of Electronics DOG...W/Z/Q 155 106 8 180 175 D=5 194 Accessory Valve in the bypass (between measuring tube and measuring cell) for easy sensor changing and for protection of the sensor when starting the installation. 1/09 2014 7