Available online at Scholars Research Library

Similar documents
Appendix II- Bioanalytical Method Development and Validation

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Method Development and Validation for the Estimation of Darunavir in Rat Plasma by RP-HPLC

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

Open Access. Determination of Linezolid in Human Plasma Using Turbulent Flow Online Extraction and Tandem Mass Spectrometry INTRODUCTION:

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Impact factor: 3.958/ICV: 4.10 ISSN:

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

LC-MS-MS Method for Determination of Metolazone in Human Plasma

Definitive EtG/EtS LC-MS/MS Analysis:

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

LC-MS/MS METHOD FOR THE SIMULTANEOUS DETERMINATION OF DESLORATADINE AND ITS METABOLITE 3-HYDROXY DESLORATADINE IN HUMAN PLASMA

LC-MS/MS Analysis of Phytocannabinoids and their

DEVELOPMENT AND VALIDATION OF A HPLC METHOD FOR IN-VIVO STUDY OF DICLOFENAC POTASSIUM

A Pre-Clinical Pharmacokinetic-Pharmacodynamic Modelling and Biodistribution Studies of Donepezil Hydrochloride by Validated HPLC Method

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Sreekanth Kakarla et al. / Journal of Pharmacy Research 2015,9(12), Available online through

Received: ; Accepted:

Conc n of A OAs present (um) Conc n of B OAs present (um)

High-Throughput LC-MS/MS Quantification of Estrone (E1) and Estradiol (E2) in Human Blood Plasma/Serum for Clinical Research Purposes

Reverse Phase High Performance Liquid Chromatography method for determination of Lercanidipine hydrochloride in bulk and tablet dosage form

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Volume 6, Issue 2, January February 2011; Article-015

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Development and validation of bioanalytical method for the determination of Valcyclovir HCl in human plasma by liquid chromatoghraphy

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

Development and Validation of Stability-Indicating RP-HPLC Method for Estimation of Atovaquone

Analytical Method Development and Validation of Lafutidine in Tablet dosage form by RP-HPLC

Simple, Precise and Accurate HPLC Method of Analysis for Nevirapine Suspension from Human Plasma

RP-HPLC Method Development and Validation of Dapagliflozin in Bulk and Tablet formulation

International Journal of Pharmacy and Pharmaceutical Sciences Vol 2, Issue 1, 2010

Research Article METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF ELBASVIR AND GRAZOPREVIR BY RP-HPLC

RP-HPLC Estimation of Trospium Chloride in Tablet Dosage Forms

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

Development and validation of RP-LC method for lisinopril dihydrate in bulk and its pharmaceutical formulations

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Development and validation of RP-HPLC method for determination of marker in polyherbal marketed Kankasava formulations

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

January March JCPS Volume 6 Issue 1.

Validated RP-HPLC Method for Estimation of Cefprozil in Tablet Dosage Form

Int. J. Pharm. Sci. Rev. Res., 30(2), January February 2015; Article No. 09, Pages: 63-68

International Journal of Pharma and Bio Sciences V1(1)2010. HPLC method for analysis of Lercanidipine Hydrochloride in Tablets

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Highly sensitive and rapid analysis of synthetic dyes in sea food by LC/MS/MS

Lupin Research Park, Pune

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Low-level Determination of 4-Hydrazino Benzoic Acid in Drug Substance by High Performance Liquid Chromatography/Mass Spectrometry

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

4.1 MATERIALS 4.2 EQUIPMENTS

A validated chiral HPLC method for the enantiomeric purity of alogliptin benzoate

SIMPLE AND SENSITIVE VALIDATED REVERSE PHASE HPLC-UV METHOD FOR THE DETERMINATION OF LYMECYCLINE IN PHARMACEUTICAL DOSAGE FORMS

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

STABILITY INDICATING METHOD OF RELATED IMPURITIES IN VENLAFAXINE HYDROCHLORIDE SUSTAINED RELEASE TABLETS

High-sensitivity, high-throughput quantitation of catecholamine metabolites in urine by LC/MS/MS for clinical research

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Highly sensitive quantitative estimation of genotoxic impurities from API and drug formulation using LC/MS/MS

Development and Validation of Sensitive RP-HPLC Method for the Estimation of Glibenclamide in Pure and Tablet Dosage Forms

A High Sensitivity Dual Solid Phase Extraction LC-MS/MS Assay for the Determination of the Therapeutic Peptide Desmopressin in Human Plasma

Development and Validation of Stability Indicating RP-HPLC Method for the Determination of Anagrelide HCl in Pharmaceutical Formulation

ISSN: ; CODEN ECJHAO E-Journal of Chemistry , 9(1), 35-42

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Novus International Journal of Analytical Innovations 2012, Vol. 1, No. 3

14. Sensitive and Rapid High Performance liquid chromatography. Tandem mass spectrometry method for the estimation of

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

A New Polymer-based SPE Sorbent to Reduce Matrix Effects in Bioanalytical LC-MS/MS

VALIDATION OF HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR DETERMINATION OF STAVUDINE IN HUMAN PLASMA

Translational Biomarker Core

BD Vacutainer Barricor Blood Collection Tube is the Tube of Choice for LC- MS/MS Analysis of Bioactive Cannabinoids in Plasma

Journal of Chemical and Pharmaceutical Research

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD TO DETERMINE CINITAPRIDE HYDROGEN TARTARATE IN BULK AND PHARMACEUTICAL FORMULATION

Available online Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Ultrafast Analysis of Methadone and Metabolite EDDP in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS

CHAPTER I. Introduction of HPLC, LC-MS/MS and aim of the work

Transcription:

Available online at www.scholarsresearchlibrary.com Scholars Research Library Der Pharmacia Lettre, 2015, 7 (4):122-128 (http://scholarsresearchlibrary.com/archive.html) ISSN 0975-5071 USA CODEN: DPLEB4 A rapid and sensitive LC MS/MS assay for the determination of propafenone and its active metabolite 5 hydroxy propafenone in human plasma using hybrid SPE precipitation technology Sujan Kumar D. P. 1, Palavan C. 1 and Seshagiri Rao J. V. L. N. 2* 1 College of Pharmaceutical Sciences, Andhra University, Visakhapatnam, Andhra Pradesh, India 2 Srinivasarao College of Pharmacy, Madhurawada, Visakhapatnam, India ABSTRACT The quality of sample extraction had a significant impact on mass spectrometry results. The presence of phospholipids in the sample extracts resulted in poor quantitation and also it decreases the method robustness. Here we adopted a novel sample preparation Hybrid SPE phospholipid technology to extract plasma samples for improved phospholipid removal. This new method allowed simultaneous quantification of propafenone and 5-OH propafenone at lower levels 0.5 and 0.25 ng/ml respectively. The phospholipid free filtrate obtained through Hybrid SPE-Phospholipid cartridge was chromatographed onto Gemini C18 column (75 x 4.6 mm, 3.0 µm). An isocratic mobile phase of a mixture of 10mM ammonium formate (ph 3.0 adjusted with formic acid) and methanol (20:80%V/V) at a flow rate of 0.5 ml/min was used. Precursor ion and product ion transition for analytes and IS were monitored on a TSQ Vantage triple quadrupole mass spectrometer, operated in the positive ionization mode. Method was validated over a concentration range of 0.50-500.00 ng/ml for propafenone, 0.25-250.00 ng/ml for 5- OH propafenone. The intra- and inter-day precision over the concentration range for propafenone and 5-OH propafenone were lower than 6.1 and 14.2% (coefficient of variation, %CV), and accuracy was between 99.5 108.7 and 94.6 108.3%, respectively. By using this new Hybrid SPE-Phospholipid technology the risk of phospholipid accumulation on column was knocked out completely and resulted in good peak shape with excellent column performance. Keywords:, 5-OH propafenone, LC-MS/MS, Hybrid SPE phospholipid technology INTRODUCTION Atrial fibrillation is the most common, clinically significant arrhythmia [1, 2]. is a chiral antiarrhythmic drug used clinically as a racemate mixture of (S) and (R) propafenone. Although both enantiomers are equally potent in their activity as sodium channel blockers the (S)-enantiomer exhibits β-blocking activity approximately 100 times higher [3]. undergoes extensive first pass metabolism by cytochrome P450 2D6 into two active metabolites 5-hydroxypropafenone and N-despropylpropafenone. Both the metabolites have antiarrhythmic activity comparable to that of propafenone with a negligible β-adrenergic activity [4]. Several chromatographic methods including HPLC-UV [5-9], gas chromatography-mass spectrometry (GC-MS) [10] have been reported for the determination of propafenone and 5-OH propafenone in biological matrices. Most of the reported HPLC-UV methods have a very long run time of more than 25 min and have used a high volume of plasma (1 ml) with tedious liquid-liquid extraction steps. The HPLC method developed by Minoo afshar et al [11] has used a simple protein precipitation method with a minimal plasma volume of 250µl but the run time was 25 min. 122

Among the published LC-MS/MS methods [12-14] the method developed by Liping Pan et al [15] is the only method which has short run time of 6 min and with a limit of quantification of 1.5 ng/ml for propafenone from sustained release formulations. This method was developed in beagle dog plasma and didn t focus on separation and quantitation of its active metabolite 5-OH propafenone. To the best of our knowledge this is the first LC-MS/MS method developed for the simultaneous quantification of propafenone and its active metabolite 5-OH propafenone in human plasma in a short runtime of 4 min and with limit of quantification of 0.5 and 0.25 ng/ml respectively. Hybrid-SPE-Precipitation technology was used as sample preparation technique to achieve a sensitivity which is 10 folds higher compared to recently published method. MATERIALS AND METHODS Chemicals and materials The reference sample of propafenone hydrochloride (>98.0%) and 5 hydroxy propafenone hydrochloride (99.75%) were purchased from Clear synth labs (Mumbai, India) and d5 hydrochloride (98.22%) from Vivan Lifesciences Ltd, India and their chemical structures were shown in Fig 1. Hybrid-SPE phospholipd catridges were purchased from Sigma (Sigmaaldrich, UK). Water used for the LC MS/MS analysis was collected from Milli Q water purification system procured from Millipore (Bangalore, India). HPLC grade acetonitrile and methanol were purchased from J.T Baker (Phillipsburg, USA). Analytical grade formic acid and ammonium formate were purchased from Merck, (Mumbai, India). The control human plasma sample was procured from Deccan s Pathological Labs, (Hyderabad, India). HCl 5-OH propafenone HCl d5 HCl (IS) Fig.1 Chemical structures of propafenone, 5-OH propafenone and internal standard Chromatographic conditions An HPLC system (Shimadzu, Kyoto, Japan) consisting of a binary LC 20AD prominence pump and an auto sampler (SIL HTc) and a solvent degasser (DGU 20A3) were used for the study. The separation of analytes was performed on Gemini C18 column (75 x 4.6 mm, 3.0 µm) (Phenomenex, Cheshire, UK). Aliquots of the processed samples (20 µl) were injected onto the column, which was maintained at 35 C. An isocratic mobile phase of a mixture of 10mM ammonium formate (ph 3.0 adjusted with formic acid) and methanol (20:80%V/V) was delivered at a flow rate of 0.5 ml/min into the mass spectrometer. Mass spectrometer conditions A TSQ Vantage triple stage quadrupole mass spectrometer (Thermo Scientific,USA) with a heated electro spray ionization (HESI-II) probe operated in positive ion mode at a spray voltage of 4.0 kv, capillary temperature of 270 0 C and vaporizer temperature of 350 0 C. Sheath and auxillary gas pressures were set at 50 and 10 units respectively. Compound optimisation was done manually using Thermo TSQ Tune Master 2.1.0.1028 (Thermo Scientific,USA) by infusion into the mass spectrometer and the scan parameters were shown in Table1. Selective Reaction Monitoring (SRM) mode was used for data acquisition. Peak integration and calibration were carried out using LC Quan 2.5.2 software. 123

Table 1: Mass Spectrometry Parameters Analyte Parent ion Collision Product ion (m/z) (m/z) Energy (V) Tube lens 342.2 116.1 27 105 5-OH propafenone 358.3 116.2 31 95 -d5 347.1 121.1 28 105 Preparation of stock, working solutions, calibration and quality control samples Primary stock solutions (1 mg/ml) of propafenone, 5 hydroxy propafenone, and internal standard were prepared in methanol separately and these stocks were stored at 2 8 C. Two sets of working solutions containing a mixture of propafenone and 5-OH propafenone were prepared in methanol and water (50:50, v/v; diluent) separately for the preparation of calibration standards and quality control samples. Calibrations standards (CC) containing a mixture of two analytes were prepared by 2% addition of working solution in human blank plasma (20 µl of working solution was added to 1 ml human plasma) giving final concentrations of 0.500, 1.270, 3.750, 12.500, 24.990, 49.980, 99.960, 249.900, 425.000, 500.000 ng/ml for propafenone and 0.250, 0.640, 1.870, 6.250, 12.500, 24.990, 49.980, 124.950, 212.950, 250.000 ng/ml for 5 hydroxy propafenone. The CC samples were analyzed along with the quality control (QC) samples for each batch of plasma samples. The QC samples were prepared at five different concentration levels of 0.520 (lower limit of quantification, LLOQ), 1.350 (low quality control, LQC), 26.800 (middle quality control, MQC 1), 125.000 (MQC 2) and 375.000 (high quality control, HQC) ng/ml for propafenone and 0.260 (LLOQ), 0.700 (LQC), 12.500 (MQC 1), 65.800 (MQC 2) and 187.500 (HQC) ng/ml for 5 hydroxy propafenone. All the prepared plasma samples were stored at 40 ± 10 C. A separate working solution of internal standard (100 ng/ml) was also prepared in the diluent. HybridSPE-Phospholipid Technology (Sample preparation) HybridSPE-Phospholipid catridges were used for effective removal of phospholipids and for accurate and reproducible LC-MS/MS Analysis. Protein precipitation was performed offline by adding 100 µl of spiked plasma followed by 300 µl of 1% formic acid in acetonitrile containing internal standard (100 ng/ml) into 1.5 ml eppendorf tube. Samples were thoroughly mixed up by vortexing for 30 sec. 400 µl of the above mixture was transferred into a Hybrid SPE catridge. Samples were passed through the Hybrid SPE catridge by applying a positive vacuum. The filtrate was analyzed directly using the analytical conditions. Method validation The validation of the above method was carried out as per US FDA guidelines [16]. The parameters included selectivity, specificity, sensitivity, matrix effect, linearity, precision and accuracy, recovery, dilution integrity, and stability. RESULTS AND DISCUSSION Method development The goal of this work is to develop a simple, rapid and a sensitive LC MS/MS method for the simultaneous determination of propafenone and 5 hydroxy propafenone suitable for pharmacokinetic and bioequivalence studies. Hence, during method development different options were evaluated to optimize detection and chromatography parameters. Tuning was done in positive and negative ionization modes using ESI source. The signal intensities obtained in the positive ion mode was much higher for the analytes than the negative mode. Data in the SRM mode were considered, which showed better selectivity. Once the mass spectrometer conditions were set, chromatographic conditions such as mobile phase, flow rate, column type and injection volume were monitored to obtain the good resolution from the endogenous components which in turn affect sensitivity and reproducibility of the method. The mobile phase composition was optimized with acetonitrile and methanol by varying its proportion with volatile buffers like ammonium acetate, ammonium formate as well as acid additives like acetic acid and formic acid in varying strength. Symmetric peak shape, better separation and best sensitivity were achieved with 10mM Ammonium formate (ph 3.0 adjusted with formic acid): Methanol (20:80%V/V) as the mobile phase. Among the various chromatographic columns tested for their suitability Gemini C 18, 75 4.6 mm, 3.0µm column gave good peak shape and response even at lowest concentration level for both the analytes. The retention time of propafenone, 5 hydroxy propafenone, and internal standard (2.18, 1.71, and 2.17 min, respectively) were short enough allowing a small run time of 4.0 min with a mobile phase flow rate of 0.5 ml/min. Stable labeled internal standard is suggested for bioanalytical assays to increase assay precision and limit variable recovery between analyte and the IS. -d5 was used as internal standard in this method. 124

When used a standard protein precipitation method with acetonitrile or methanol with and without acid resulted in increased back pressure of the column after few injections. Steps were taken to back flush the column before start of each run. This didn t improve the performance of column and this explains the elution of phospholipids intermittently from the column affecting the reproducibility and peak shape. Liquid Liquid extraction with different extraction solvents yielded poor recovery for 5-OH propafenone. Before moving onto Solid phase extraction for better cleaner extracts a new technology for removal of phospholipids namely HybridSPE-Phospholipid which combines the simplicity of protein precipitation with the selectivity of solid phase extraction (SPE) for the targeted removal of phospholipids in biological plasma was evaluated. The mean recovery was more than 80% for both propafenone and 5-OH propafenone which was more than the LLE and S/N ratio was 10 times higher compared to standard protein precipitation, suggesting that the risk of phospholipid accumulation was knocked out completely and resulted in good recovery with excellent column performance using Hybrid SPE-Phospholipid technology. Method Validation Selectivity The selectivity of the method was examined by analyzing extracted blank human plasma samples from six different sources. As shown in Fig.2 and 3 for individual analytes, no significant interference in the processed blank plasma samples were observed at the retention times of the analytes and internal standard. Fig.2. Typical chromatogram of propafenone (left panel) and IS (right panel) in human blank plasma [A], plasma spiked with internal standard [B] and lower limit of quantification sample along with IS [C] 125

Fig.3. Typical chromatogram of 5-OHpropafenone (left panel) and IS (right panel) in human blank plasma [A], plasma spiked with internal standard [B] and lower limit of quantification sample along with IS [C] Sensitivity The reliable lowest limit of quantification (LLOQ) for the propafenone and 5 hydroxy propafenone was set at the concentration of 0.5 ng/ml and 0.25 ng/ml, respectively. At this concentration, the precision and accuracy results were found to be 5.38% and 106.2% and 8.17% and 99.8% for propafenone and 5 hydroxy propafenone. The signal to noise ratio (S/N) was measure at LLOQ concentration and found to be 5 for both the analytes. Matrix effect Matrix effect assessment was done with the aim to check the effect of different lots of plasma on the back calculated value of QC's nominal concentration. The precision and accuracy for propafenone at LQC concentration were found to be 5.28% and 107.2%, and at HQC level they were 4.34% and 108.2%, respectively. Similarly, the precision and accuracy for 5 hydroxy propafenone at LQC concentration were found to be 8.07% and 108.3%, and at HQC level they were 4.92% and 97.9%, respectively. These results indicate that no significant matrix effect was observed in all the six batches of human plasma for the analytes at low and high quality control concentrations. Linearity, Precision and Accuracy Ten point calibration curve was found to be linear over the concentration range of 0.50 500 ng/ml for propafenone 0.25 250 ng/ml for 5 hydroxy propafenone. After comparing the two weighting models (1/x and 1/x 2 ), a regression equation with a weighting factor of 1/x 2 of the drug to the IS concentration was found to produce the best fit for the concentration detector response relationship for both the analytes in human plasma. The mean correlation 126

coefficient of the weighted calibration curves generated during the validation was 0.99 for both the analytes. The results for intra day and inter day precision and accuracy in plasma quality control samples are summarized in Table 2. The intra day and inter day precision values were within 15% of the relative standard deviation (RSD) at low, middle 1, middle 2 and high quality control level, whereas LLOQ QCs level was within 20%. The intra day and inter day accuracy deviation values were within 100 ± 15% of the actual values at low, middle 1, middle 2 and high quality control level, whereas LLOQ QCs level was within 100± 20%. The results revealed good precision and accuracy. Table 2: Intra day and inter day precision and accuracy of the method Analyte 5-OH Conc. (ng/ml) Intra-day Precision and Accuracy (n=12; 6 from each batch) Conc. Found (Mean ± SD; ng/ml) Precision (%CV) Accuracy (%) Inter-day Precision and Accuracy(n=30; 6 from each batch Conc. Found Precision Accuracy (Mean ± SD; (%CV) (%) ng/ml) 0.520 0.5159 ± 0.02339 4.53 99.2 0.5174± 0.03168 6.12 99.5 1.350 1.3936 ± 0.08118 5.83 103.2 1.3938± 0.07837 5.62 103.2 26.800 27.4575 ± 1.67744 6.11 102.4 27.3270± 1.52385 5.52 101.9 125.000 135.9283 ± 4.12760 3.04 108.7 134.2490±5.15488 3.84 107.4 375.000 389.6733 ± 18.87515 4.84 103.9 390.5323±18.3624 4.70 104.1 0.260 0.2530±0.03061 12.10 97.3 0.2580±0.01691 6.55 99.2 0.700 0.7482 ± 0.10682 14.28 106.8 0.7284±0.05307 7.29 104.0 12.500 13.0683 ± 1.04510 8.00 104.5 13.4524±0.94297 7.01 107.6 65.800 71.2833 ± 3.77403 5.29 108.3 69.6413±3.48566 5.01 105.8 187.500 184.5042± 19.05371 10.33 98.4 177.4487±9.30913 5.25 94.64 Recovery and dilution integrity The recoveries of analytes and the internal standard were good and reproducible. The mean recovery (%) was 85.05, 80.22 and 87.58% for propafenone, 5-OH propafenone and internal standard with CV (%) less than 5%. Analyte Stability test Table 3: Stability data for propafenone and 5-OHpropafenone QC (spiked conc. (ng/ml) Mean ± SD (ng/ml Precision (%CV) Accuracy/ Stability (%) Bench top a 1.350 1.3983±0.05670 4.05 103.5 375.000 403.0500±33.04217 8.20 107.4 Freeze Thaw b 1.350 1.3248± 0.11838 8.94 98.1 375.000 405.2500±22.76015 5.62 108.0 Wet Extract c 1.350 1.2962±0.05388 4.16 96.0 375.000 384.8370± 45.44420 11.81 102.6 Auto Sampler d 1.350 1.2587 ± 0.08864 7.04 93.2 375.000 359.4095± 36.28007 10.09 95.8 Re injection e 1.350 1.4033±0.01366 0.97 101.3 375.000 403.8767±25.26407 6.26 95.4 Long term f 1.350 1.3367±0.14685 10.99 99.0 375.000 388.3633±47.80075 12.31 103.5 Bench top a 0.700 0.6880±0.05217 7.58 98.29 187.500 178.6317±10.32239 5.78 95.27 Freeze Thaw b 0.700 0.7302±0.03173 4.35 104.31 187.500 177.9167±14.17185 7.97 94.89 Wet Extract c 0.700 0.6840±0.08473 12.39 97.71 5-OH 187.500 177.8133±16.22439 9.12 94.83 Auto Sampler d 0.700 0.7100±0.04599 6.48 101.43 187.500 206.3133±14.05315 6.81 110.03 Re injection e 0.700 0.7065±0.02561 3.62 103.9 187.500 187.1900±7.89803 4.22 101.6 Long term f 0.700 0.6682±0.04208 6.30 95.4 187.500 197.8887 ± 21.84971 11.40 105.5 a after 7 h at room temperature; b after 3 Freeze thaw cycles; c after 50 h at 2 8 0 C ; d after 72 h at 2 8 0 C; e after 52 h at 2 8 0 C; at 40 0 C for 45 days The upper concentration limits can be extended to 875.0 ng/ml for propafenone and 437.5 ng/ml for 5 hydroxy propafenone and further diluted by 1/2 and 1/4 dilutions with screened human blank plasma. The precision and accuracy for propafenone at 1/2 dilution were found to be 4.55% and 92.6%, and at 1/4 dilution they were 6.35% and 90.6%, respectively. Similarly, the precision and accuracy for 5 hydroxy propafenone at 1/2 dilution were found to be 3.98% and 106.7%, and at 1/4 dilution they were 1.67% and 111.5%, respectively. 127

Stability studies Various stability experiments carried out namely bench top stability (7 h), autosampler stability (72 h), repeated freeze thaw cycles (3 cycles), reinjection stability (52 h), wet extract stability (50 h at 2 8 C) and long term stability at 40 C for 45 days. The mean % nominal values of the analytes were found to be within ±15% of the predicted concentrations for the analytes at their LQC and HQC levels (Table 3). Thus, the results were found to be within the acceptable limits during the entire validation. CONCLUSION Sample preparation plays an important role to address problems encountered during method development for quantification of small molecules from biological samples by LC-MS/MS. Matrix effect due to endogenous phospholipids results in poor sensitivity and specificity. Here we adopted a new sample preparation technique called Hybrid SPE phospholipid for cleaner extracts. The proposed method has several advantages compared to standard protein precipitation and LLE and also this is a simple single step method and can be used as alternative to Solid phase extraction for sample clean up to eliminate matrix related effects on LC-MS/MS with improved S/N ratio. Acknowledgements The authors gratefully acknowledge Well Quest Life Sciences, Hyderabad, India; for providing the necessary facilities to carried out this study. REFERENCES [1] ED Murgatroyd, AJ Camm, Lancet, 1993, 341, 1317 22. [2] TE Cuddy, SJ Connolly, Canadian Journal of Cardiology, 1996, 12, 9A 11A. [3] JT Hii, HJ Duff, ED Burgess, Clinical Pharmacokinetics, 1991, 21, 1 10. [4] KA Thompson, DH Iansmith, LA Siddoway, RL Woosley, DM Roden, Journal of Pharmacology and Experimental Therapeutics, 1988, 244, 950 955. [5] PK Kunicki, D Paczkowski, D Sitkiewicz, Polish Journal of Pharmacology and Pharmacy, 1992, 44, 161-71 [6] HY Aboul-Enein, SA Bakr, Biomedical Chromatography, 1993, 7, 38-40. [7] R Bohm, R Ellrich, R Koytchev, Die Pharmazie, 1995, 50, 542-455. [8] LR Pires de Abreu, VL Lanchote, C Bertucci, EJ Cesarino, PS Bonato, Journal of Pharmaceutical and Biomedical Analysis, 1999, 20, 209-216. [9] G Lamprecht, K Stoschitzky, Journal of Chromatography B, Analytical Technologies in the Biomedical and Life Sciences, 2009, 77, 3489-3494. [10] B Marchesini, S Boschi, Journal of Chromatography, 1983, 278, 173-178. [11] M Afshar, M Rouini, The International Journal of the Japan Society for Analytical Chemistry, 2004, 20, 1307-1311. [12] D Zhong, X Chen, Journal of Chromatography B, Biomedical Sciences and Applications, 1999, 721, 67-75. [13] X Chen, D Zhong, H Blume, European Journal of Pharmaceutical Sciences, 2000, 10, 11-16. [14] U Hofmann, M Pecia, G Heinkele, K Dilger, HK Kroemer, Journal of Chromatography B, Biomedical Sciences and Applications, 2000, 748, 113-123. [15] L Pan, Y Qian, M Cheng, P Gu, Y He, X Xu, L Ding, Acta Pharmaceutica Sinica B, 2015, 5, 74-78. [16] Guidance for industry: bioanalytical method validation, U.S. Department of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research (CDER), Center for Biologics Evaluation and Research (CBER), May 2001 128