The new Agilent 1290 Infinity Quaternary LC

Similar documents
Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Fast and Flexible Optimization of Modifier Concentrations Using an Agilent 1290 Infinity LC System with Blend Assist

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

Application Note. Author. Abstract. Pharmaceutical QA/QC. Vinayak A.K Agilent Technologies Bangalore, India

Transferring HPLC methods from the HP 1090 Series to the Agilent 1100 Series HPLC system

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Practical Applications of Method Translation Using the Agilent Method Translation Tool Rita Steed Inside Application Engineer Agilent Technologies

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

Agilent LC & LC-MS Cannabis Testing

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Application Note. Agilent Application Solution Analysis of acaricides in honey. Authors. Abstract. Food

High Resolution Fast LC

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

Figure 1. Structures for Vitamin B2 and Vitamin B1.

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

Analysis of Beer by Comprehensive 2D-LC with the Agilent 1290 Infinity 2D-LC system

Automated method development using Agilent 1100 Series HPLC systems, Agilent ChemStation and ChromSword software. Application

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Successfully Scaling and Transferring HPLC and UPLC Methods

-xt. -xt SYSTEM. Specifications for PAL-xt Systems. Valid for PAL-xt System models only. Prep and Load Platform

LC and LC/MS Column Selection Flow Chart

Application Note. Authors. Abstract. Energy & Chemicals, Biofuels & Alternative Energy

Using the Agilent 1290 Infinity II Multicolumn Thermostat with Extreme Temperatures and Flow Rates

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Application Note Pharmaceutical QA/QC. Agilent Application Solution. Authors. Abstract. Syed Salman Lateef Agilent Technologies, Inc.

Getting More Resolution from Your LC Michael Woodman Columns and Consumables September 10, 2008

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

HPLC Method Development: Standard Practices and New Columns

Detection of Trace Level Pharmaceuticals in Drinking Water by Online SPE Enrichment with the Agilent 1200 Infinity Series Online-SPE Solution

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Fast methods for the determination of ibuprofen in drug products

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

Too Polar for Reversed Phase What Do You Do?

Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters. Application. Angelika Gratzfeld-Huesgen

HPLC Method Development with Eclipse Plus: Standard Practices and New Columns. Agilent Technologies

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted

How proteins separate on reverse-phase HPLC

Taking Full Advantage of UHPLC with Agilent 6460A Triple Quadrupole MS. Outline

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Application Note. Author. Abstract. Xinlei Yang Agilent Technologies Co. Ltd Shanghai, China

The Agilent 1290 Infinity II Multi Method Solution

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

Routine MS Detection for USP Chromatographic Methods

HPLC Praktikum Skript

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Choosing Columns and Conditions for the Best Peak Shape

Application Note. Agilent Application Solution Analysis of PAHs in soil according to EPA 8310 method with UV and fluorescence detection.

High Speed vs. High Resolution Analyses in HPLC: A Critical Performance Comparison of Column Options Using Poppe and Kinetic Plots

Comprehensive 2D-LC Analysis of Chinese Herbal Medicine

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

HPLC Separation Robustness and Ruggedness Assessing the Effects of Experimental Variables During Method Development

HPLC Method Development: Standard Practices and New Columns. Agilent Technologies February 2007

Eliminating Unwanted Variability in LC Methods: More Uptime, More Sample Throughput

Agilent 1200 Series Rapid Resolution LC and Rapid Resolution LC/MS Optimization Guide

Application. Authors. Abstract. Introduction. Hydrocarbon Processing

On the Advantages and Costs of Two-dimensional HPLC (2D-LC)

Quantification of Furocoumarins

Method Transfer between HPLC and UHPLC Instruments Equipment-related challenges and solutions

HPLC Column Troubleshooting: Is It Really The Column? LC Columns and Consumables. Robyn C. Woolley Online Application Engineer July 24, 2007.

Qualification Specifications for Agilent 1100/1200 HPLC Systems

Analysis of Phthalates in Body Wash using Solid-Supported Liquid-Liquid Extraction

Impact of Instrument Dispersion on Performance of HPLC Capillary Columns

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

for Acclaim Mixed-Mode HILIC-1 Column

ION CHROMATOGRAPHY SYSTEM S 150

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Application Note. Edgar Naegele. Abstract

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

Dilution(*) Chromatography

Comprehensive Polymer Analysis Strategies

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

William E. Barber, Ph.D. Applications Chemist October

Validated HPLC Methods

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

Acclaim Mixed-Mode WCX-1

Tips and Tricks of Faster LC Analysis Without Capital Investment It may be easier than you think!

HPLC analysis of VFAs, Furfural and HMF

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Overcome Top Challenges in Analytical Method Development and Validation

Improving HPLC Column Selection and System Performance

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Transcription:

The new Agilent 1290 Infinity Quaternary LC How binary pump-like performance can enhance your lab efficiency Sebastian Krahe Produktspezialist HPLC Agilent Technologies Page 1

The 1290 Infinity Quaternary LC System Leveraging the Performance of the 1290 Infinity Binary LC System 1290 Infinity DAD with 60mm cell (& HDR optional) 1290 Infinity TCC with broadest valve selectivity 1290 Infinity Autosampler (with Flexible Cube for lowest carry-over) 1290 Infinity Quaternary Pump Page 2

Innovation: 1290 Infinity Quaternary Pump Quaternary Pump with Binary Pump-like Performance 1290 Infinity Quaternary Pump Boost Performance Highest accuracy and precision for composition and flow, with exceptionally low delay volume Save Time Accelerates transfer of existing HPLC methods to UHPLC Reduce Costs Outstanding UHPLC performance at HPLC-like costs of ownership Page 3

1290 Infinity Quaternary Pump Various tools enabling the high performance Inlet-Weaver Switchable Jet Weaver Mixer 4-channel Degasser Multi-Purpose- Valve MCGV (Multi- Channel-Gradient- Valve) Pump Head In-line Filter Page 4

Multipurpose valve functions for highest comfort Standard Application for standard Delay Volume Page 5

Agilent 1290 Infinity Quaternary Pump Specifications & Benefits Power Range For any kind of analysis Composition Accuracy and Precision < 0.15 % RSD or 0.02 min SD ± 0.4 % (1-99 % Composition B) High RT precision in gradient runs Flow Accuracy and Precision < 0.07 % RSD or 0.01 min SD ± 1.0 % or 10 µl High RT precision in isocratic runs Composition Range 1-99 % Wide analytical range Delay Volume < 350 µl For fast quaternary gradients Page 6

Composition Accuracy and Precision Step Gradient Analysis with Tracer Different mixtures (H2O, MeOH, ACN) at different pressures and different flow rates Full application range! Page 7

Flow and Composition Accuracy and Precision Isocratic analysis of Glucocorticoids 1: Hydrocortisone 2: Beclomethasonedi-proprionate 3: Hydrocortisone acetate Column: Agilent ZORBAX Eclipse Plus C18, 4.6 x 100 mm, 5 µm (p/n 959996-902) Mobile phase: Water/ Acetonitrile = 30/70 Flow rate: 1 ml/min Stop time: 5 min Injection vol.: 3 µl (needle wash for 3 sec) Column Temp.: 30 C DAD: 254/10 nm, (ref 400/ 80 nm), 20 Hz, slit 4 nm Page 8

Flow and Composition Accuracy and Precision Isocratic analysis of Glucocorticoids mau 30 25 1 2 RT of compounds very sensitive regarding changes in mobile phase composition! 20 15 10 5 0 1 1.5 2 2.5 3 3.5 3 Water/ACN 29:71 Water/ACN 31:69 Water/ACN 30:70 min Page 9

Accuracy and Precision Isocratic analysis of Glucocorticoids Specification (< 0.07 %) mau 35 30 25 1: Hydrocortisone 2: Beclomethasonedi-proprionate 20 15 10 3: Hydrocortisone acetate 5 0 0 1 2 3 4 min Page 10

Accuracy and Precision Dynamically vs. pre-mixed solvents Isocratic composition by dynamic mixing: A/B = 70:30 Isocratic composition by premixed solvent: Which method is better? RSD RT(%) A/B = 70:30 Page 11

Accuracy and Precision Dynamically vs. pre-mixed solvents Retention time precision Single operator, single bottle Dynamic mixing For illustration only, data can be found in Agilent Application Note 5991-0098EN Page 12

Accuracy and Precision Dynamically vs. pre-mixed solvents Retention time precision Single operator, single bottle Dynamic mixing Single operator, multiple bottles For illustration only, data can be found in Agilent Application Note 5991-0098EN Page 13

Accuracy and Precision Dynamically vs. pre-mixed solvents Retention time precision Single operator, single bottle Dynamic mixing Single operator, multiple bottles Multiple operators, multiple bottles For illustration only, data can be found in Agilent Application Note 5991-0098EN Page 14

Accuracy and Precision Gradient Analysis of Clopidole Clopidole Clopidole is used as prophylactics and/or therapeutics in the prevention or treatment of coccidiosis in the poultry and rabbit industries. It is added to finished feed in a concentration range of 100 to 125mg/kg. Column: Agilent ZORBAX SB-C18, 4.6 x 250 mm, 3.5 µm (p/n 884950-567) Mobile phase: A = Water/ACN (95/5) + 0.1 % TFA B = Water/Acetonitrile(40/60) + 0.1 % TFA Gradient: 0 100 % B in 15min Flow rate: 1 ml/min Stop time: 15 min Injection vol.: 1 µl Column Temp.: 30 C DAD: 263/10 nm, (ref. 400/ 80 nm), 10 Hz Page 15

Accuracy and Precision Dynamically vs. pre-mixed solvents Gradient from 0 to 100 % with premixed solvent: H 2 O +0.1% TFA 0 100 % B ACN +0.1% TFA Gradient from 5 to 60 % B by dynamic mixing: H 2 O +0.1% TFA ACN +0.1% TFA 5 60 % B Which method is better? RSD RT(%) Page 16

Accuracy and Precision Dynamically vs. pre-mixed solvents Dynamic mixing 5 60 % B Premixed, 0 100 % B mau mau 200 150 150 100 100 50 50 0 0 6.0 6.4 6.8 7.2 7.6 min 6.0 6.4 6.8 7.2 7.6 min Page 17

Accuracy and Precision Dynamically vs. pre-mixed solvents Retention time precision 0.5 0.4 RSD RT (%) 0.3 0.2 0.1 0 Specification (< 0.15 %) 5 60 % B Dynamic mixing 0 100 % B Premixed Page 18

Agilent 1290 Infinity Quaternary Pump Specifications & Benefits Power Range For any kind of analysis Composition Accuracy and Precision < 0.15 % RSD or 0.02 min SD ± 0.4 % (1-99 % Composition B) High RT precision in gradient runs Flow Accuracy and Precision < 0.07 % RSD or 0.01 min SD ± 1.0 % or 10 µl High RT precision in isocratic runs Composition Range 1-99 % Wide analytical range Delay Volume < 350 µl For fast quaternary gradients Page 19

Ternary/Quaternary Gradients Blend Assist You need different concentrations of modifiers in your analysis, would like to have just one stocksolution and do online dilution to profite from the quaternary mixing capability of your pump? Here is a simple tool BlendAssist! Water Water 1% TFA Desired method conditions - example: 1. 5 to 95% gradient of ACN with 0.1% TFA in Water and 0.08% TFA in ACN 2. 20 80% gradient of ACN with 0.5% TFA in Water and 0.4% TFA in ACN Without BlendAssist you need to either pre-mix the required solvents or by using stock-solutions of TFA in Water and ACN to program complex gradients (%A, B, C, D). ACN ACN 1% TFA With BlendAssist: just program your binary organic/aqueous gradient and define the dilution factor! Page 20

Ternary/Quaternary Gradients Blend Assist, different Phosphate buffer concentrations H 3 C CH 3 N H 3 C CH 3 N O NH 2 C H 3 N O OH C H 2 N Disopyramide Quinidine Column: Agilent ZORBAX Eclipse Plus C18, 4.6 x 100 mm, 1.8 μm Mobile phase: A = Water B = Water/Acetonirile 20:80 + 0.05 M NaH 2 PO 4, ph=4.6 Gradient: var. Flow rate: 1.5 ml/min Stop time: 8.5 min Injection vol.: 1 µl Column Temp.: 40 C DAD: 270/10 nm, (ref. 360/ 100 nm), 20 Hz Page 21

Ternary/Quaternary Gradients Blend Assist, different Phosphate buffer concentrations mau Quinidine 400 300 Procainamide Acetyl- Procainamide 0.05 M buffer 200 0.025 M buffer 100 0 Disopyramide 0.01 M buffer 0 1 2 3 4 5 6 7 8 min Page 22

Ternary/Quaternary Gradients Blend Assist - simple Tool for Online-Dilution of Modifiers and Gradient Set-Up BlendAssist - Solvent/modifier channel definition Page 23

1290 Infinity Quaternary Pump Conclusion Full 1290 Infinity LC Power range Highest composition precision and accuracy, solvent independent and across pressure and flow rate range Full application range with binary-like pump performance! Blend Assist for Buffer/Additive Blending ISET-ready! Full flexibility! Page 24