Exhaust noise a new measurement technology in duct

Similar documents
The diagram below. to the by the. outlet into. calculation. Since TRANSMISSION VIA STRUCTURE. Vibration Via Supports Duct Breakout

ON SOUND POWER MEASUREMENT OF THE ENGINE IN ANECHOIC ROOM WITH IMPERFECTIONS

Vibration Generations Mechanisms: Flow Induced

Prediction of Sound Propagation From Power Transmission Plant

Sound power qualification of a turbocharger in enclosed environment using an innovating acoustic imaging processing: Generalized Acoustic Holography

Analysis and Control of Noise Emissions of a Small Single Cylinder D.I. Diesel Engine

Effect of Length and Porosity on the Acoustic Performance of Concentric Tube Resonators

Fundamentals of silencing and their practical application in screw compressor plants

Comparison of Noise Test Codes when Applied to air Compressors

Method of Measuring Machinery Sound Within an Equipment Space

THE ACOUSTIC IMPEDANCE MEASUREMNET SYSTEM USING TWO MICROPHONES

Sound power level measurement in diffuse field for not movable sources or emitting prominent discrete tones

Experimental determination of far field sound power due to panel and vent radiation of a portable diesel generator

Sound power level determinations at laboratory and field environments: An experimental comparison

Noise Attenuation for Chimney Engineers presented by Steven Reid at the CICIND Conference Lisbon Sept CICIND

Wojciech ŁAPKA, Czesław CEMPEL

In-situ measurements of the complex acoustic impedance of materials in vehicle interiors

Multi Acoustic Prediction Program (MAPP tm ) Recent Results Perrin S. Meyer and John D. Meyer

Modeling and simulation of windows with noise mitigation and natural ventilation

University of Kentucky

Product Data. Brüel & Kjær B. Sound Intensity Calibrator Type 3541

PRODUCT DATA. Sound Intensity Calibrator Type 3541-A. Uses and Features

Sound Power Measurement of Domestic Boilers

Comparison of Two Methods for Measurement of Horn Input Impedance

American International Journal of Research in Science, Technology, Engineering & Mathematics

Acoustics - Determination of sound power levels of noise sources - Precision methods for anechoic and semi-anechoic rooms

Prediction of Transformer Core Noise

Evaluation of standards for transmission loss tests

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1

Basics of Sound and Noise. David Herrin, Ph.D., P.E. University of Kentucky Department of Mechanical Engineering

Engineering Noise Control

PREDICTION OF FAN SOUND POWER

Dominant noise sources identification as cost-effective way in total sound power reduction. Slobodan Jankovic 1, Miodrag Ivkovic 2

Numerical Prediction of the Radiated Noise of Hermetic Compressors Under the Simultaneous Presence of Different Noise Sources

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Drop towers and fitness flooring assemblies

Turbomachinery Aeroacoustics

Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method

WHITE PAPER. Challenges in Sound Measurements Field Testing JUNE 2017

Modeling Measurement Uncertainty in Room Acoustics P. Dietrich

Introduction to Acoustics Exercises

Consideration of the pulsation as a design criterion for a newly developed oil-injected process gas screw compressor

Answer - SAQ 1. The intensity, I, is given by: Back

Document No 10/6298/001/GLA/O/R/001 Issue : B2. Kingspan Renewables Ltd. Kingspan KW6 Wind Turbine Noise Performance Test

Environmental Effects and Control of Noise Lecture 2

ROOM RESONANCES USING WAVE BASED GEOMET- RICAL ACOUSTICS (WBGA)

Uncertainties associated with the use of a sound level meter

Treatment of Tonal Sound in the Development of Fan Sound Ratings

1 Wind Turbine Acoustics. Wind turbines generate sound by both mechanical and aerodynamic

1. Introduction. 2. ISO 3745 and ISO standard comparison

DETERMINATION OF AIRBORNE SOUND POWER LEVELS EMITTED BY GEAR UNITS

Summary. The basic principles of the simulation technique SERT

MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE

Design and Development of Automobile Silencer for Effective Vibration Control

Measures and sources of sound. Professor Phil Joseph

Cyclical Mutation of Stator and Rotor Designs and Their Impact to the Acoustic Behavior of Induction Motor

Numerical Model of the Insertion Loss Promoted by the Enclosure of a Sound Source

EXPERIMENTAL INVESTIGATION OF NOISE PARAMETERS IN HVAC SYSTEMS

AP Physics Problems Simple Harmonic Motion, Mechanical Waves and Sound

Product Data. Brüel & Kjær B. Sound Power Source Type Introduction

Transmission loss of rectangular silencers using meso-porous and micro-perforated linings

Muswellbrook Coal Company

Physics 221: Optical and Thermal Physics Exam 1, Sec. 500, 14 Feb Please fill in your Student ID number (UIN): IMPORTANT

Active Minimization of Acoustic Energy Density to Attenuate Radiated Noise from Enclosures

Ecolibrium. All natural. A new style for supermarkets? THE OFFICIAL JOURNAL OF AIRAH AUGUST 2017 VOLUME 16.7 RRP $14.95

Swirl Diffusers Type DLA 7 and DLA 8

Fan Noise Control by Enclosure Modification

FAN ENGINEERING. Fan Sound & Sound Ratings

Sound radiation and transmission. Professor Phil Joseph. Departamento de Engenharia Mecânica

Influence of loudspeaker directivity on the measurement uncertainty of the acoustic testing of facades.

Improving the Accuracy of Dynamic Vibration Fatigue Simulation

SOUND ABSORPTION OF SLAT STRUCTURES FOR PRACTICAL APPLICATIONS

Uncertainties in Acoustics

Physics 25 Section 2 Exam #1 February 1, 2012 Dr. Alward

Chapter 10: Vibration Isolation of the Source

Some considerations on noise monitoring for air handling equipments

Noise Testing and Prediction Methods for Multi-Point Ground Flares

Acoustic Quantities. LMS Test.Lab. Rev 12A

TRANSFORMER CORE NOISE MEASUREMENT AND PREDICTION

1618. Dynamic characteristics analysis and optimization for lateral plates of the vibration screen

Report. Draft. Laboratory for Acoustics

Estimating Community Sound Levels of Large Industrial Equipment

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Standard Practices for Air Speed Calibration Testing

Last time: small acoustics

Acoustic design of lightweight cabin walls for cruise ships

(a) Explain what is meant by the following words: (2) (b) The diagram shows the path of two microwaves arriving at point S. 6cm S. 12 cm.

PRACTICE NO. PD-ED-1259 PREFERRED May 1996 RELIABILITY PAGE 1 OF 6 PRACTICES ACOUSTIC NOISE REQUIREMENT

MEASUREMENT OF INPUT IMPEDANCE OF AN ACOUSTIC BORE WITH APPLICATION TO BORE RECONSTRUCTION

Effect of effective length of the tube on transmission loss of reactive muffler

ODEON APPLICATION NOTE Calibration of Impulse Response Measurements

A Transfer Matrix Method for Estimating the Dispersion and Attenuation of Plane Waves in a Standing Wave Tube

Sound field decomposition of sound sources used in sound power measurements

Nonlinear Losses in Electro-acoustical Transducers Wolfgang Klippel, Daniel Knobloch

Noise in enclosed spaces. Phil Joseph

Measurement of Acoustic Properties of light weight concrete SL-Deck

Test Report. RI Acoustic Lab. Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier. 20 Feb. 07

DELTA Test Report. Measurement of sound absorption coefficient for 15 mm Fraster felt Plus acoustic panels with mounting depth 45 mm

Acoustic Environment of the VEGA Launch Vehicle at Lift-Off

ISO INTERNATIONAL STANDARD

Transcription:

Exhaust noise a new measurement technology in duct Mr Claes-Göran Johansson MSc,Sen. Scient. Acoustics ABB Corp.Research, Västerås Sweden, claes-goran.johansson@se.abb.com Mr Kari Saine MSc, Wärtsilä Finland Ltd, Engine Technology, Vaasa Finland, kari.saine@wartsila.com Mr Petter Johansson Consultant, Ztreme Engineering, Gothenburg Sweden petter.johansson@ztreme.com Prof. Mats Åbom The Royal Institute of Technology, Stockholm Sweden matsabom@kth.se. Abstract / Background The noise emission from large internal combustion engines, from kw to MW, is inherently difficult to predict with a high degree of confidence. How the actual noise field propagates within a complex exhaust gas system and how to measure exhaust noise where the gas flow in the duct could be as high as m/s and temperature about 4 degree. This translates to increased cost for silencer over-sizing or added costs associated with an exhaust gas system that fails to meet the required noise signature. This paper deals with a new and verified hot gas (< 6 C) in-situ noise measurement technology called SESAM (Silencer & Exhaust System Acoustic Measurement). It makes it possible to accurately measure source strength and specific insertion loss of the various components in the exhaust train behind large or 4 stroke diesels and power plant gas turbine. Also these measurements can be carried out easy way under field conditions with this portable system. When designing an exhaust system for diesel engine it is most important to have a correct source spectrum for the engine and the noise requirement raised by the final customer in order to do the precision design for the attenuation in the system. In the past the source spectrum of diesel engines always has been an issue of large uncertainty due to the fact that no general reliable measurement procedure exists. The paper presents the practical induct SESAM technology and discusses measurement results versus the time consuming and less accurate classic method. The system was tested at Wärtsilä Vaasa factory with real engine exhaust environmental. Also the loadspeaker was used as a sound source.. Measurements setup The purpose of the SESAM-test was to perform the measurements with both loudspeaker and an engine. In both cases noise levels were measured inside the duct and after open duct by the classical method. All the measurements were performed at Wärtsilä Vaasa factory during last year, 4. Below a general layout of the measurements is presented. The length between duct inlet (in the test cell) and the open duct (on the roof) is 6,9m and has 4 bends, each with 9 degree, see photo and. The induct measurement holes are located 6,9 to,9 meters from the inlet. On the roof the system was opened up and a meter duct (photo ) was removed. At this point the classical method for sound power measurement was done. Induct measurements was done before this open duct as well as after the silencer (then with closed duct again). The classical method was first calibrated (Qcorr) with a loudspeaker source to minimize the influence of the surroundings at the open duct. Measurements were performed with the diesel engine

running at different loads. After disconnecting the engine a special loudspeaker source was applied to the duct inlet and similar measurements was performed at cold conditions. on roof Loudspeaker source (Calibrated power out +internal micr.inside 6 Duct open Silencer On the ground 9 Position - movable microphone distance m 6 holes available Before silencer 6 34 Roof Removable part Open duct Silencer Sesam probe Induct before silencer holes available duct diam mm 8 Sesam probe Induct after silencer Loudspeaker Roof / floor Engine W8L 3 4 Loudspeaker source in a box with an internal microphone. This source was calibrated in free field and then applied to the duct when the engine was disconnected D ROOF turbo to 3 diam 3 diam 4 diam TPS 8 T-A =, m (,4+,3 ) A-B =,4 m (,4 ) B-C = 6,m ( 3,6 +,4 +, ) C-D =,4m (6,9-6,=,4 ) Induct temperature Celsius % / 3grd idling / grd % / 34grd 98 8 Total duct length - Engine(T) to open duct (D)= (,+,4+6,+,4=8, m - Loudsp.box (B) to open duct (D) = 6,+,4=6,9m 9 8 6 3 3 3 Gas mass-flow approx,,9 kg/s for 894rpm. 4 Gas density,64kg/m3 at 34dgr. Gas flow velocity induct (d=,m) at measurement points is 3,m/s C = Recommended positions 4 = 6 = 3 4 6 8 9 8 = 4 3 3 98 8 9 = 3 8 Vertical duct = 6 -H oles before the silencer Φ 3 -Chosen to fit the recom- B mendation distances ( ) A Spatial averaging of 6 sondpositions 3 4 6 Speed 9pm Engine W8L Fig. Overview first part of the exhaust duct system. Details regarding the exhaust system attached to engine W8L and important data for the evaluation of the induct measurements. 3. Induct versus Classic method with loudspeaker at the inlet of the duct Comparing injected sound power with measured power in the duct - using the measurement probe will primarily indicate if the bends contribute with attenuation. If so it would only be expected above Hz. The duct itself has minor attenuation because of the short length (<m). First measurement classic measurement of sound pressure level (on the roof) calculated to sound power radiated at 9 degree angle at the open duct. Second measurement- six flush measurements averaged to induct sound power and adjusted for end reflection and directivity radiated at 9 degree angle at the open duct.

Photo. The loudspeaker box mounted for radiation into the duct. Injected sound power spectrum, first measured externally in free field and then corrected after mounting on duct. The classic method to estimate the radiated sound power (Lw) from any type of sound source is standardized by enclosing the source within a fictive surface and then measure the sound pressure level (Lpi) at many points (n) on this surface. Normally the surface is half a Lw = Lp - log Q + log 4 π r Lp = log /n Σ ( Lp/ + Lpi/ +...+ Lpn/ ) Lw = sound power level n= number of measurement point Lpi = sound pressure value at point (i) Lp = logaritmic average for all points log Q = directivity = for a half hemisphere r = radius (m) hemisphere (Q=) with the centre on a hard and sound reflecting ground. Position of the actual source should be at the centre. The radius (r) is normally chosen larger than the largest dimension of the source. After the average (Lp,average) from a measurement is calculated, the power (Lw) is found by logarithmic adding half of the hemisphere surface (log 4π *r*r/). Measurement over a half hemisphere was not possible on the roof. This situation is very normal at engine manufacturers in general and causes problems to follow the classic acoustic standard. In fact only one direction could be used for significant measurements and in that direction 6 points was corrected and averaged, photo. Photo. Surrounding at the roof. The points had number (-) and the pole radius as an average seen from the open duct center was, 4 meter. Each measurement value (Lpi) was corrected with (logqcorr, i). The formula for the classic value of the sound power then became: I= L w, classic = log /6 Σ I= ( (Lp -log Q co rr - log 4 πr ) i= (Lp -log Q co rr - log 4 πr ) i= +...+ ) 3

Lw (dbl) FIG(6..) Sound Power, Speaker Excitation, Classic Method, Calibr Environment (Qcorr), Mean radius =.4m, 6 Pole Pos, Log Avr (Pos to ) Lw(6...) = Lp + *Log(Qcorr) -*Log(4*pi*r^), LwTot = 4 dbl 9 8 Fig. Sound Power, Speaker Excitation, Classic Method, Calibr. Environm. (Qcorr), LwTot = 4 dbl 6 3, 4 63 8 6 3 4 63 8 6 3 4 63 8 4. Induct method to estimate the sound power radiated at the open duct In order to find the radiated sound power at the open end of the duct - and be able to do the comparison with the classic method SPL (dbl) FIG(6..) SPL Measured In Duct, Loudspeaker Excitation, LogAvr 6 Holes, Open Duct the random spectrum in fig 3 has to be recalculated from flush measured sound pressure level to radiated sound power. This is done by corrections for duct area, multimode transition, end reflection and directivty (9 degree). 9 8 3, 4 63 8 6 3 4 63 8 6 3 4 63 8 Fig 3. SPL Measured In Duct, Loudspeaker Excitation, LogAvr 6 Holes Comparing with the classic method can be seen in fig 4 and the deviation between the two results in fig. Totally for the induct method 6, dbl and the classic method 4 dbl. The db difference is acceptable and induct method also should show the highest value because that method covers the power more efficient inside the duct. The classic method - in our case usable with 6 points in only one direction could never cover all radiated power accurately. Lw (dbl) FIG(6..8) Sound Power In Duct, Speaker Excitation, SESAM Probe Measurement, LwTot =6, dbl (6..) Sound Power,Speaker Excitation, Classic Method, Calibr Environ LwTot = 4dBL Fig 4. Sound Power in Duct, Speaker Excitation, SESAM Probe Measurement compared to Classic Method 9 8 Individually per /3 octave band the difference is <db except for and 63 Hz. Normally sound predictions from 6 3, 4 63 8 6 3 4 63 8 6 3 4 63 8 models are forgiving in the sense that large deviations on the /3 octave level averages out and the total value comes close. This happens when the deviations are spread symmetrically around the correct value. 4

The geometrical size of the surrounding ducts on the roof are close to ½ a wavelength at Hz and consequently a strong influence could be expected on the directivity field in the classic measurement. At 63 Hz the injected sound spectrum from the loudspeaker had the lowest input and problems with the background influence FIG(6..9) Difference of Sound Power, Speaker Excitation, Classic Method - SESAM Probe Measurement is believed to be the reason for the (dbl) Diff(6..9) = Lw(6..) - Lw(6..8), Total Diff = -. dbl deviation. - - 3 4 63 8 6 3 4 63 8 6 3 4 63 8 Fig. Difference of Sound Power, Speaker Excitation, Classic Method - SESAM Probe Measurement - Lw (dbl) 9 8 FIG(6..8) Sound Power In Duct, Speaker Excitation, SESAM Probe Measurement, LwTot =6, dbl (6..) Sound Power,Speaker Excitation, Classic Method, Calibr Environ LwTot = 4dBL Difference caused by not accurate Directivity field for the Classic Method Shape of the Loudspeaker Spectra injected at the Duct Inlet Low injected level, 63Hz is extra sensitive for Background Noise in the Classic Method Fig 6. At 63 Hz the sound power level is 86 dbl for the classic method. This power value corresponds to 86 log/4π 9, = 63 dbl sound pressure value which might have been caused by the background level on the roof. 6 3 4 6 8 9 3 4 6 8 9 3 4 6. Induct method versus Classic method, diesel engine at load % The analysis is similar with the exception that: - the loudspeaker source is changed to engine W8L - a special spatial averaging method is used to improve the accuracy of the induct method. Temperature in the exhaust gas is 3 Celsius degree and the flow speed m/s at the probe positions. The engine is injecting much higher sound power level into the inlet duct in comparison with the loudspeaker and the spectrum is a line spectrum with many harmonics. The engine speed 9 rpm creates an ingnition frequency of 6 Hz. On the roof the duct is open and the duct between the SPL (dbl) 6 4 3 FIG(..A) SPL of W8L Engine, In Duct SESAM Probe Measurements - Hole,4,6,8,9 & for Load: % (Probe Transfer Corrected) Open Duct, /4 oct band Hz 3Hz 4Hz 6Hz 88Hz 8Hz Hz Hz Hole Hole 4 Hole 6 Hole 8 Hole 9 Hole engine and this opening is finite with a length of approximate 8 meter. This length and the duct temperature constitute duct resonances and standing wave phenomena s. Fig. Illustration of duct resonances in the finite duct after the engine.,,,, Freq /4 octave band

The spatial averaging technique - over 6 holes at chosen distances for a known gas temperature eliminates the problem with the unknown positions of standing waves inside the duct. From six spectrums measured with flush mounted probe one space averaged spectra is calculated. First measurement - six flush measurements averaged to induct sound power. Induct sound power adjusted for end reflection and directivity radiated at 9 degree angle at the open duct. Second measurement - classic measurement of sound pressure level (on the roof) recalculated to sound power radiated at 9 degree angle at the open duct. 6. Spatial averaging of 6 induct measurements Fig 8 shows the measured sound pressure levels for 6 different holes along the duct. Notice the large deviations SPL (dbl) 4 3 FIG(..) SPL of W8L Engine, In Duct SESAM Probe Measurements - Hole,4,6,8,9 & for Load: % (Probe Transfer Corrected) Open Duct Hole Hole 4 Hole 6 Hole 8 Hole 9 Hole between the spectrums depending on the position of the probe. The standing wave pattern inside the duct has pressure maxima and pressure minima versus distance and frequency in such a way that an efficient averaging technique is needed to create one spectrum. 9 8 3, 4 63 8 6 3 4 63 8 6 3 4 63 8 Fig 8. SPL of W8L Engine, Open Duct SESAM Probe Measurements Hole, 4,6,8,9 & for Load: %. Spatial averaging of the 6 hole induct measurement - result Comparing normal logarithmic averaging with the spatial averaging very little deviation was found for this actual measurement, fig 9. A conclusion that this would also be the case for other measurements is not correct because the premises could be completely different. Fig shows the spread in the measurements for each / 3 octave band (max/min) and the standard deviation of the measurement error versus the spatial average method (zero line). Standard dev. = (square root((/6) sum(i-te value spatial value)exp)). SPL (dbl) 6 Induct Meas with SESAM Probe, Engine W8L at %, Lp(..) = 6 Holes Spatial RMS Method Lp(..) = Log Avr 6 Holes Fig 9. Induct Meas with SESAM Probe, Engine W8L at % Spatial RMS Method compared with Log Avr 6 Holes 4 3 3 4 63 8 6 3 4 63 8 6 3 4 63 8 6

(dbl) FIG(..3) Standard Deviation & Spread of Measurment Error using Spatial RMS Method on 6 Holes compared with one arbitrary Measurment at one Hole out of the same 6 Holes MIN MAX MEAN DEV (+/-) STANDARD DEV (S) Fig. Standard Deviation & Spread of Measurement Error using one arbitrary hole in relation to the Spatial rmsmethod (with 6 holes)-the zero level. - 3 4 63 8 6 3 4 63 8 6 3 4 63 8 8. Sound Power diesel engine - comparing induct method with classic method Comparing with the classic FIG(.3.8) Sound Power In Duct, W8L at % Load, SESAM Probe Measurement, LwTot =36 dbl Lw (dbl) (.3.) Sound Power,W8L at % Load, Classic Method, Calibr Environ LwTot = 38 dbl method the deviation between 4 the two results is shown in fig. Totally the induct method 3 gave 36 dbl and the classic method gave 38 dbl. 9 Fig. Sound Power In Duct, W8L at % Load, SESAM Probe Measurement compared with Classic Method, Open Duct 8 3 4 63 8 6 3 4 63 8 6 3 4 63 8 Individually per /3 octave band the difference is < 6dB, fig, but the spread deviations averages down totally to db. The db difference is acceptable but the induct method should show the highest total value because that method covers the power more efficiently inside the duct. However that is not seen in this engine measurement. The difference with the random noise loudspeaker test, see fig4, is the harmonic spectrum caused by the engine. To accurate capture distinct tones, with the classic method, would need a dramatically improvement of the precautions for the classic measurement. The reason for the high tone contributions at 63 and Hz in the classic measurement is therefore caused by the bad acoustic environment on the roof in combination with an engine spectrum built by distinct tones and too few possible measurement points. FIG(.3.9) Difference of Sound Power, W8L at %, Classic Method - SESAM Probe Measurement Diff(.3.9) = LwClassic(.3.) - LwSesam(.3.8), TotDiff = dbl (dbl) 3 4 63 8 6 3 4 63 8 6 3 4 63 8 - Fig. Difference of Sound Power, W8L at %, Open Duct Classic Method - SESAM Probe Measurement, Tot Diff = dbl - - 9. CONCLUSION All induct measurements with the probe technique gave fast and reliable results. The flexible and battery supported SESAM vest-system made it very easy to change between different measurement locations without extra time delays.

Photo 3. Induct measurements with SESAM The classic method was performed at a realistic situation for an engine manufacturer. The acoustic precautions for the classic method were: - problems with background noise - not free field conditions - disturbed near field - too few measurement points and directions to cover a hemisphere surface Sound power was injected with two different sources - a large loudspeaker (cold system without gas flow) and the engine W8L (hot system with gas flow). Comparing the two methods for the two different sources showed a total difference of < db. The induct method is easier and more accurate when two frequency independent constants are needed to calculate the induct sound power from only six flush mounted measurements. The classic method on the other hand needs times more measurement points in free field, a frequency dependant directivity function, a frequency dependant end reflection function and ash-, break out-and bend attenuation corrections to achieve the same induct sound power. The classic method can only be performed by opening up a duct system. The induct method on the other hand can be performed almost anywhere on an exhaust system. Reference CG.JOHANSSON, K.SAINE, P.JOHANSSON, M.ÅBOM: Exhaust Noise-a new novel in situ measurement technology in duct. th International conference sound and vibration -.., Lisbon. 8