GAS CAMERA MOBILE IMAGING SYSTEM FOR VISUALISING METHANE PLUMES AT DISTANCES BETWEEN 0 M AND 100 M AND MORE

Similar documents
Remote Detection of Methane by Infrared Spectrometry for Airborne Pipeline Surveillance: First Results of Ground-Based Measurements

Remote Measurement of Emissions by Scanning Imaging Infrared Spectrometry

EM 27/SUN Series. Innovation with Integrity. For Atmospheric Measurements FT-IR

Infrared imaging Fourier-transform spectrometer used for standoff gas detection

Electromagnetic Radiation and Scientific Instruments. PTYS April 1, 2008

ABB Remote Sensing Atmospheric Emitted Radiance Interferometer AERI system overview. Applications

Calibrating the Thermal Camera

Infrared thermography

Introduction to Fourier Transform Infrared Spectroscopy

Chapter 18. Fundamentals of Spectrophotometry. Properties of Light

PERFORMANCE AND EXAMPLES OF MEASUREMENTS OF A MID INFRARED INTERFEROMETRIC HYPERSPECTRAL IMAGER

Fabry-Perot Interferometer for atmospheric monitoring useful for EAS detection E.Fokitis 1, K. Patrinos 1, Z. Nikitaki 1

Advanced Spectroscopy Laboratory

Introduction to Fourier Transform Infrared Spectroscopy

Introduction to RS Lecture 2. NR401 Dr. Avik Bhattacharya 1

2001 Spectrometers. Instrument Machinery. Movies from this presentation can be access at

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Because light behaves like a wave, we can describe it in one of two ways by its wavelength or by its frequency.

Design and Development of a Smartphone Based Visible Spectrophotometer for Analytical Applications

Remote Sensing Systems Overview

Characterization of high temperature solar thermal selective absorber coatings at operation temperature

Physical Basics of Remote-Sensing with Satellites

How does your eye form an Refraction

Thermal And Near infrared Sensor for carbon Observation (TANSO) On board the Greenhouse gases Observing SATellite (GOSAT) Research Announcement

Chemistry Instrumental Analysis Lecture 15. Chem 4631

Real-time ppb CO 2 Impurity Detection by an Advanced FTIR- UVF System

HIGH TEMPERATURE MEASUREMENT BY THERMOGRAPHY ON CSP

The Spectral Radiative Effects of Inhomogeneous Clouds and Aerosols

Optical Spectrometers

PRINCIPLES OF REMOTE SENSING. Electromagnetic Energy and Spectral Signatures

Course Details. Analytical Techniques Based on Optical Spectroscopy. Course Details. Textbook. SCCH 211: Analytical Chemistry I

Electro-Optical System. Analysis and Design. A Radiometry Perspective. Cornelius J. Willers SPIE PRESS. Bellingham, Washington USA

Fourier Transform Infrared. Spectrometry

Radiative heat transfer

Characterization and Calibration of a Fourier Transform Spectroradiometer for Solar UV Irradiance Measurements

PRINCIPLES OF PHYSICAL OPTICS

Application of Hydroxyl (OH) Radical Ultraviolet Absorption Spectroscopy to Rocket Plumes

Ground and On-Orbit Characterization and Calibration of the Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS)

Atmospheric Lidar The Atmospheric Lidar (ATLID) is a high-spectral resolution lidar and will be the first of its type to be flown in space.

Astronomy. Optics and Telescopes

Chemical Detection Using the Airborne Thermal Infrared Imaging Spectrometer (TIRIS)

Introduction to Photovoltaics

Characterisation & Use of Array Spectrometers

Radiation in the atmosphere

ABSTRACT. a Institute for Space Imaging Science, University of Lethbridge, Alberta, T1K 3M4, Canada; b Joint

Scanning, standoff laser-based leak imaging and quantification Co-authors:

RS DYNAMICS ECOPROBE 5. Portable IR/PID Gas Analyzer PID. PID and IR Analyzers

Introduction to FT-IR Spectroscopy

Lecture 26. Regional radiative effects due to anthropogenic aerosols. Part 2. Haze and visibility.

Chapter 5. Telescopes. Copyright (c) The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

FAFF20: Multispectral Imaging

n ( λ ) is observed. Further, the bandgap of the ZnTe semiconductor is

Tananyag fejlesztés idegen nyelven

Chemometric Approach to the Calibration of Light Emitting Diode Based Optical Gas Sensors Using High-Resolution Transmission Molecular Absorption Data

LIDAR. Natali Kuzkova Ph.D. seminar February 24, 2015

Radiation and the atmosphere

HYPERSPECTRAL IMAGING

MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE

ME 476 Solar Energy UNIT TWO THERMAL RADIATION

Chapter 4 Nadir looking UV measurement. Part-I: Theory and algorithm

Light and Telescope 10/24/2018. PHYS 1403 Introduction to Astronomy. Reminder/Announcement. Chapter Outline. Chapter Outline (continued)

Inaugural University of Michigan Science Olympiad Tournament

Energy and Radiation. GEOG/ENST 2331 Lecture 3 Ahrens: Chapter 2

MULTICHANNEL NADIR SPECTROMETER FOR THEMATICALLY ORIENTED REMOTE SENSING INVESTIGATIONS

Hyperspectral Atmospheric Correction

White Paper. Overview: NDIR Definition:

Detection of trace contamination on metal surfaces using the handheld Agilent 4100 ExoScan FTIR

FIRST FIELD MEASUREMENTS AND DEVICE IMPROVEMENTS FOR MULTI SPECTRAL VOLUME SCATTERING METER (MVSM)

Polarimetric measurements of long-wave infrared spectral radiance from water

Exploring the Atmosphere with Lidars

SOME ASPECTS OF PYROMETRY OF "WHITE" OBJECTS V.E.

Lecture 2: principles of electromagnetic radiation

Todays Topics 3/19/2018. Light and Telescope. PHYS 1403 Introduction to Astronomy. CCD Camera Makes Digital Images. Astronomical Detectors

Astronomy 203 practice final examination

Remote Sensing How we know what we know A Brief Tour

Photoelectric Effect

How does your eye form an Refraction

University of Cyprus. Reflectance and Diffuse Spectroscopy

Calibration capabilities at PTB for radiation thermometry, quantitative thermography and emissivity


NIGAS. i o n. N B C D e t e c t. The Neutron Induced Gamma Spectrometer

IR spectral characterization of customer blackbody sources: first calibration results

Fourier Transform Infrared Spectrometry

Optical Systems Program of Studies Version 1.0 April 2012

Influence of sun radiation on results of non-contact temperature measurements in far infrared range

Vladimir Vavilov. Tomsk Polytechnic University, Russia

Hampton University 2. University of Wisconsin-Madison 3. NASA Langley Research Center

1901 Application of Spectrophotometry

FOURIER TRANSFORM INFRARED SPECTROSCOPY (FTIR)

What are the most important properties of a telescope? Chapter 6 Telescopes: Portals of Discovery. What are the two basic designs of telescopes?

Fourier Transform Infrared Spectroscopy (Perkin Elmer - Spectrum One)

PARCWAPT Passive Radiometry Cloud Water Profiling Technique

Lecture # 04 January 27, 2010, Wednesday Energy & Radiation

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

Automatic Adjustment of Integration Time in the NIR Camera for Calibrated Temperature Measurement during Inductive Heating Processes

Chapter 6 Telescopes: Portals of Discovery

Near-Infrared Spectroscopy of Nitride Heterostructures EMILY FINAN ADVISOR: DR. OANA MALIS PURDUE UNIVERSITY REU PROGRAM AUGUST 2, 2012

A thermal detector combines an absorber and a temperature sensor

Reflectivity in Remote Sensing

Computer faceted thermal model of helicopter

Transcription:

23rd World Gas Conference, Amsterdam 2006 GAS CAMERA MOBILE IMAGING SYSTEM FOR VISUALISING METHANE PLUMES AT DISTANCES BETWEEN 0 M AND 100 M AND MORE Main Author Peter Schwengler, E.ON Ruhrgas AG, Pipelines Competence Centre Germany Co-Author Dr. Roland Harig, TUHH, Hamburg University of Technology Germany - 1 -

TABLE OF CONTENTS 1. Abstract 2. Body of Paper 2.1 Introduction 2.2 Passive Remote Sensing of Methane 2.3 Infrared Remote Sensing Systems 2.4 Field Measurements 2.5 Results 2.6 Conclusion 3. Authors 4. References 5. List of Figures - 2 -

1. ABSTRACT In order to ensure the safe and economic operation of natural gas networks and gas plants, leaks should be detected as soon and efficient as possible. Currently, hand-held systems based on flame ionisation detectors or semiconductor gas sensors are used to inspect pipelines and plants. Scanning imaging FTIR spectrometry is a new method for remote detection and imaging of gases in the atmosphere. Based on this method scientists of the Hamburg University of Technology in cooperation with E.ON Ruhrgas AG developed a tool for identifying and visualising natural gas clouds purposely or accidentally released from gas transport facilities during operation or construction. The superposition of a video image and a false colour image of the gas cloud allows the localisation of the source of methane. Currently a field-portable gas camera system is under way that will provide an improved spatial resolution compared to realised systems and allows an real time imaging of a gas cloud containing a methane fraction. The new Gas Camera is based on of a focal plane array detector combined with a frequency-selective element selecting narrow IR frequency bands characteristic for methane emission. This system does not longer employ a mirror scanning infrared system. Similar to the FTIR system, a conventional digital video image taken in the visible frequency range is superimposed on the IR-image, in order to relate the infrared measurements of a cloud to the location of the release. The new device will be a mobile imaging system for detecting and visualising methane plumes at distances between 0 m and 100 m. The project Gas Camera is funded by a GERG-Partner Group consisting of E.ON Ruhrgas AG, Snam Retegas, Gasunie, Fluxys and Esders Engineering. In this paper experiments that proved the effectiveness of both methods as well as first experiments with the measurement set-up that will be used for the planned detection system are presented. - 3 -

2. Body of Paper 2.1 Introduction In order to further improve the safe and economic operation of natural gas networks and gas plants it is advantageous to use remote and real time sensing systems for the detection of small gas leakages. Given that an effective system has to be mobile, highly sensitive and also easy to use, infrared multi spectral imaging had been chosen as basis for the design. In order to locate gas clouds easily and intuitively, a video image is superimposed onto the gas image. Current passive remote detection systems available on the market are based on Fourier-transform infrared (FTIR) spectrometry. Based on this method, a scanning imaging remote sensing system has been developed at Hamburg University of Technology (TUHH). The system employs an interferometer with a single detector element (Bruker OPAG 22, Bruker Daltonics) in combination with a telescope and a synchronised scanning mirror. The results of the spectral analyses are displayed by an overlay of a false colour image, the gas cloud image, on a video image. In cooperation with E.ON Ruhrgas AG the system has been applied to the detection and visualisation of natural gas clouds. Current FTIR systems like the mirror scanning systems are tested under hard field conditions, e.g. for detection of hazardous gas clouds in military applications. The disadvantage is that there is a speed limit given by the scanning rate which is necessary to get low detection limits. Furthermore those systems are to heavy to be manually transported. For an effective system a highly sensitive hand-held equipment, a Gas Camera, has to be developed which allows to see where gas exits are located. That means with a Gas Camera it is possible to monitor large areas and get an image of a gas cloud that is easy to interpret by the operator. Gas cloud visualisation is the core of the innovation. The goal of the project Gas Camera is to develop a mobile, hand-held, unit suitable for detecting methane escaping from small leaks, The Gas Camera will cover distances from the gas source of 0 up to at least 100 m. The design should allow to detect and localise leaks efficiently in real time, several times per second, and cover a universal and broad range of applications. The newly designed remote sensing system is intended to increase the safety during construction or operation of gas transport facilities and pipelines. The design should allow to detect and localise leaks efficiently in real time and cover a universal and broad range of applications. The expectation in remote sensing systems is to increase the safety issues during constructions or operation of power plants and pipelines by using a more effective gas detection system. - 4 -

2.2 Passive Remote Sensing of Methane by Infrared Spectro-Radiometry Gas clouds can be detected from a distance by infrared spectrometry. The detection is based on the analysis of radiation absorbed and emitted by the molecules of the clouds. The method is a passive detection method which exploits existing thermal background radiation for the analysis. Figure 2-1 illustrates the measurement set-up. In order to describe the characteristics of spectra measured by a passive infrared spectrometer a model in which the atmosphere is divided into plane-parallel homogeneous layers along the optical path may be used (Reference 1, 2). In most cases a model with three layers is sufficient to describe the basic characteristics of the measured radiation (Figure 2-1). Radiation from the background (layer 3) propagates through the vapour cloud (layer 2) and the atmosphere between the cloud and the spectrometer (layer 1). The cloud and atmospheric layers are considered homogeneous with regard to all physical and chemical properties. The radiation containing the signatures of all layers is measured by the spectrometer. Spectroradiometer Layer 1 Layer 2 Layer 3 T 1,τ 1 T 2,τ 2 L 3 Atmosphere Cloud Background Figure 2-1: Radiative transfer model. In this model the spectral radiance at the entrance aperture of the spectrometer L 1 is L 1 = 1 1) B1 + τ1 2 ) [(1 τ B τ ] ( τ + L 2 2 3, (1) where τ i is the transmittance of layer i, B i is the spectral radiance of a blackbody at the temperature of layer i, T i. L 3 is the radiance that enters the layer of the cloud from the background. The quantities in Equation (1) are frequency-dependent. - 5 -

If the background layer is given by a topographical target, the radiation entering the cloud L 3 contains radiation emitted by the surface and reflected radiation. L = a F( Ω, Ω ) L ( Ω ) dω + ε ( Ω 2π ) B( T 3 s down s bg ). (2) Here, a is the surface albedo, Ω s is the solid angle subtended by the aperture of the spectrometer. F(Ω s,-ω) is the surface biconical reflectance function for incident solid angle -Ω and emergent solid angle Ω s. ε(ω s ) is the directional surface emittance, and B(T bg ) is the radiance emitted by a blackbody at temperature T bg. The radiation incident on the background L down contains ambient radiation (L am ) and radiation from the sky (L sky ). The dependence on frequency is left implicit again. If the temperatures of the layers 1 and 2 are equal, Equation (1) can be simplified: L ( L ) 1 = B1 + τ 1τ 2 3 B1 (3) The spectral radiance difference caused by the cloud layer and the atmosphere L = L 1 -L 3 is given by L = ( 1 τ L τ, (4) 1 2 ) 13 where L 13 = B 1 -L 3. Equation (4) shows that the signal is basically given by the transmittance of the cloud and the atmosphere multiplied with the spectral radiance difference L 13. L 13 is proportional to the difference between the temperature of the gas and the background (first order approximation for a background with high emittance). - 6 -

2.3 Infrared Remote Sensing Systems In this work, two passive infrared remote sensing systems were used. The first system is a passive scanning infrared gas imaging system (SIGIS) which was originally developed at TUHH for the identification and visualisation of pollutant clouds. It comprises an interferometer with a single detector element (OPAG 22, Bruker Daltonik, Leipzig, Germany), an azimuth-elevation-scanning mirror actuated by stepper motors, a data processing and control system with a digital signal processor, and a personal computer (Figure 2-2). The system is described in detail in Reference 3. As a first step towards in the development of an imaging gas detection system, this system was adapted for the detection of methane. For the visualisation of gas clouds, the scanning mirror is sequentially set to all positions within the field of regard. The size and the direction of the field of regard and the spatial resolution (i.e. the angle between adjacent fields of view) are variable. Each interferogram measured by the interferometer is recorded by the FTIR (Fourier Transform InfraRed) DSP system, Fourier transformed, and the spectrum is transferred to the PC. A video processing system records and analyses images of a video camera. The spectrum is analysed and the results are visualized by a video image, overlaid by false colour images representing the density of the gas cloud. For a target compound, in our case methane, images of the coefficient of correlation between the measured spectrum and a reference spectrum of methane, the signal-to-noise ratio, and the temperature of the background are produced (Figure 2-2). Figure 2-2: Block diagram of SIGIS. - 7 -

The second system is a laboratory prototype of an imaging gas detection system, a Gas Camera. The system comprises an infrared detection system with a focal plane array (FPA, AIM Infrarot-Module GmbH, Heilbronn, Germany), a filter wheel with interference filters, and a personal computer. The interference filters have a narrow bandpass-characteristic. The passband of one Filter matches the absorption band of the target gas (target gas filter). The passband of a second filter does not contain strong absorption lines of the target gas (reference filter). The filter characteristics are illustrated in Figure 2-3. Moreover, Figure 2-3 shows the absorption band of methane that is used for the detection. Transmission/Absorbance 0.8 0.6 0.4 0.2 Filter 2 (Reference) Filter 1 (Target Gas) 0 700 800 900 1000 1100 1200 1300 1400 Frequency (cm -1 ) Figure 2-3: Selection of spectral bands using interference filters. - 8 -

In order to perform first field tests, the laboratory prototype was equipped with portable electronics (Figure 2-4). A PC program controlling all required functions of the focal plane array and the filter system has been developed. The PC software acquires data from the FPA and accumulates images in the different spectral bands of the filters (Figure 2-3). These images or difference images are displayed as false colour images. The system allows measurements, analysis, and display of the resulting images in real time. FPA Filter system Figure 2-4: Prototype System. - 9 -

2.4 Field Measurements To examine the feasibility of infrared remote sensing for leak detection, measurements were performed with the SIGIS system described in chapter 2.3. In order to simulate a leak in a pipeline, methane was released approximately 1 m below the ground through a cylindrical probe stuck into the soil. The gas partial discharged through the ground and partial escaped through the tiny gap between probe and soil. Measurements with the SIGIS system were performed from the roof of a building at a distance of approximately 100 m. During the measurements weak winds prevailed. Figure 2-5 shows the location of the release of methane from the position of the remote sensing system. For each measurement, a field of regard consisting of 30 20 directions was scanned. For the detection of methane, the spectra were analysed in the spectral range 1280-1320 cm -1. In order to examine the detection capabilities of the imaging system, measurements with the prototype gas camera were performed as the second development step. Figure 2-6 shows results of a measurement of a methane plume from a distance of approximately 20 m. The release rate of methane was 200 L/h from an 8 mm nozzle. The methane plume is clearly observable in Figure 2-6. - 10 -

2.5 Results Figure 2-5 shows results of measurements at a release rate of 50 m/h. The results are visualised in false colour images as described in chapter 2.4. In each direction of the scanning mirror, one interferogram was measured. Closed to the position of the release of methane, the signal to noise ratio increases. Since the spatial resolution of the system is limited the point of release is difficult to identify. The minimum gas escape detected was 25 L/h. The measurements confirm that natural gas clouds can be detected from a distance by passive infrared spectrometry. Release of Methane 0 7.3 Signal-to-noise ratio Figure 2-5: Location of the methane release with including video image overlay by false colour image. - 11 -

Figure 2-6 exhibits a photograph of a release location overlaid by the results of the gas camera. The release rate of methane in this case was about 200 L/h. The methane plume is clearly observable as shown in Figure 2-6. These first tests show that the new technology enables the detection of small gas releases over large distances. Because the type of gas to be detected in the application envisaged is known and an unambiguous identification is not necessary, the spectral resolution may be lower, while good resolution in terms of space is required. Thus, a reproducing gas detection system like a Gas Camera can be designed by combining a focal plane array detector, consisting of many relatively small detector elements, with an element selective to frequency or wavelength. Methane plume Release of Methane Figure 2-6: Measurement of a methane plume. The investigations confirmed that infrared multispectral imaging allows the detection and visualisation of gas clouds from long distances. In particular the second system, that employs an infrared array detector, is well-suited for leak detection at plants and pipelines and for surveillance of construction and maintenance tasks. Based on this device it is envisaged to develop a portable field prototype Gas Camera that will be evaluated by field tests under real conditions on-site during the next 3 years. - 12 -

2.6 Conclusion Scanning imaging FTIR spectrometry is a new method for remote detection and imaging of gases in the atmosphere. Based on this method scientists of the Hamburg University of Technology in cooperation with E.ON Ruhrgas AG developed a tool for identifying and visualising natural gas clouds purposely or accidentally released from gas transport facilities during operation or construction. The superposition of a video image by a false colour image of the gas cloud allows the localisation of the source of methane. The investigation results suggest to base the new gas detection system Gas Camera on the combination of a focal plane array detector with frequency-selective elements selecting narrow IR frequency bands characteristic for methane. The first detection experiments with the laboratory system show that small leaks can be localised by the system. It has been proven by the first tests performed by a laboratory set-up that a gas camera system will provide a good spatial resolution and real time imaging of a methane cloud. Similar to the FTIR system, a conventional video image taken in the visible frequency range is to be superimposed on the IR-image, in order to relate the infrared measurements of a cloud to the location of the release. The new device will be a mobile imaging system for detecting and visualising methane plumes at distances between 0 m and 100 m. The project Gas Camera is funded by a GERG-Partner group. - 13 -

3. Authors Main Author: Dipl.-Ing. Peter Schwengler E.ON Ruhrgas AG Pipelines Competence Centre Halterner Straße 125 46284 Dorsten Germany Co-Author: Dr. Roland Harig Hamburg University of Technology Institute for Measurement Technology Harburger Schlossstraße 20 21071 Hamburg Germany - 14 -

4. References 1. Beer, R.: Remote Sensing by Fourier Transform Spectrometry, (Wiley, New York 1992). 2. Flanigan, D. F.: Prediction of the limits of detection of hazardous vapors by passive infrared with the use of Modtran, Applied Optics 35, 6090-6098 (1996). 3. Harig, R., Matz, G., Rusch, P.: Scanning Infrared Remote Sensing System for Identification, Visualization, and Quantification of Airborne Pollutants in Instrumentation for Air Pollution and Global Atmospheric Monitoring, James O. Jensen, Robert L. Spellicy, Editors, Proc. SPIE 4574, 83-94 (2002). - 15 -

5. List of Figures Figures: Figure 2-1: Radiative Transfer Model Chapter 2.2 Figure 2-2: Block Diagram of SIGIS Chapter 2.3 Figure 2-3: Selection of Spectral bands using Chapter 2.3 interference Filters Figure 2-4: Prototype System of Gas Camera Chapter 2.3 Figure 2-5: Location of Methane Gas Release with Chapter 2.4 Video image overlaid by false color image Figure 2-6: Measurement of Mathane Plume Chapter 2.4-16 -