B6VMAX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Water terminal control solutions

3 Port, 2-Ton Outdoor Heat Pump

Today s A/C systems include:

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012

GB5BM Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler WARRANTY

VRF Technical Data Book

1. DEFINITIONS. B. BTUH Hourly Rate of change in Mass Heat BTUH = * CFM * ΔT (Air Heat Transfer) BTUH = 500 * GPM * ΔT (Water Heat Transfer)

REPAIR PARTS. DSZC 16/18 SEER Remote Heat Pump

4HP13 PRODUCT SPECIFICATIONS 13 SEER SPLIT SYSTEM HEAT PUMP WARRANTY

ENVIRONMENTALLY SOUND R 410A REFRIGERANT

REPAIR PARTS. GPH14 H-SERIES R-410A Package Heat Pumps GPH1424H41AA GPH1430H41AA GPH1436H41AA GPH1442H41AA GPH1448H41AA GPH1460H41AA

AIR COOLED CONDENSING UNIT

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP

nufacturing Company, L.P San Felipe, Suite

PARTS MANUAL Gas Furnace F9MAC, G9MAC

nufacturing Company, L.P San Felipe, Suite

END4X, ENW4X, ENA4X. Product Specifications VERTICAL EVAPORATOR COILS ALL N COIL MODELS CASED N COILS UNCASED N COILS ENA4X WARRANTY*

AIR CONDITIONERS 2016 COLLECTION. Window Portable Dehumidifier Through The Wall Ductless Split Units. Online Interactive Edition v.1.

REPAIR PARTS. GPG14 "M" Series Residential Package Gas Units. This manual is to be used by qualified technicians only. This manual replaces RP-G3001.

EXPLODED DIAGRAM - PARTS VIEW

ENH4X. Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS WARRANTY*

MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH

6.0 EC-SERIES CUBERS EC200-EC300-EC400-EC500-EC606 AIR, WATER AND REMOTE

PARTS LIST WATER SOURCE HEAT PUMPS HLH/HLV

Parts. Package Terminal Air Conditioner. Models and manufacturing numbers in this manual. This manual replaces RP revision 0.

REPAIR PARTS. GPH13 "M" Series Horizontal Package Heat Pumps GPH1324M41AA GPH1330M41AA GPH1336M41AA GPH1342M41AA GPH1348M41AA GPH1360M41AA

GMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace

Welcome. HVAC Change Out Regulations and Rater Verification California Track

REPAIR PARTS. DSXC16/18 Remote Condensing Units. This manual is to be used by qualified technicians only. This manual replaces RP-580D.

Product Data. CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow

REPAIR PARTS. DSZC 16/18 SEER Remote Heat Pump

REPAIR PARTS. GPH H-SERIES Package Heat Pumps

Inverter Multi-Split System

AIR COOLED CONDENSING UNIT

REPAIR PARTS. GPH13 "H" Model Package Heat Pumps GPH1324H41AB GPH1330H41AB GPH1336H41AB GPH1342H41AB GPH1348H41BB GPH1360H41BB

15.0 UNDERCOUNTER CUBERS EUC150B2 EUC200B3-EUC200-UC20B-UC20 AIR AND WATER COOLED

CEILING CASSETTE SPLIT SYSTEMS

REPAIR PARTS. DSXC 16/18 SEER Remote Condensing Unit

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

REPAIR PARTS. GPH14 Multi-Position Residential Package Heat Pump. This manual is to be used by qualified technicians only.

FFHT1831QE2 FFHT1831QM2 FFHT1831QP2 FFHT1831QQ2 FFHT1831QS2

nufacturing Company, L.P San Felipe, Suite 500

REPAIR PARTS. GPH14 H-Series Package Heat Pumps. This manual is to be used by qualified technicians only. This manual replaces RP-631C.

Product Data. CNPHP, CNRHP Evaporator Coil N Coil --- Cased Horizontal CNPHP / CNRHP

REPAIR PARTS. GPH14 "H" Residential Package Heat Pump

REPAIR PARTS. GPH14 "M" Series Residential Package Heat Pump. This manual is to be used by qualified technicians only.

REPAIR PARTS. A/GPG13 Package Gas Units

Case Study of Chilled Water Loop Low DT Fault Diagnosis

EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series

Laird Thermal Systems Application Note. Precise Temperature Control for Medical Analytical, Diagnostic and Instrumentation Equipment

REPAIR PARTS. GMS95 Single Stage Upflow Furnace GMS950453BXAB GMS950703BXAB GMS950704CXAB GMS950904CXAB GMS951155DXAB.

REPAIR PARTS. CPLT 13 SEER Series Condensing Units CPLT24-1 CPLT24-1A CPLT30-1 CPLT30-1A CPLT36-1 CPLT42-1 CPLT48-1 CPLT60-1

REPAIR PARTS. GPC13 "M" Series 3-5 Ton Package Coolers

Electrolysis System CHLORINSITU V (PLUS)

REPAIR PARTS. GPH16 Horizontal Package Heat Pumps. This manual is to be used by qualified technicians only.

Product Data. CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow CAPVU

REPAIR PARTS. AVPTC Air Handler. This manual is to be used by qualified technicians only. This manual replaces RP-775E.

REPAIR PARTS. GPG13 "M" Series Package Gas Unit

SUBMITTAL DATA: MXZ-5C42NA MULTI-INDOOR INVERTER HEAT PUMP SYSTEM

Interactivity-Compatibility. TA Hydronic College Training

McQuay Climate Control Singer. Incremental. NE, NH, NR Vintages C, D. TYA, TAA Vintages A, B. Last Manufactured: 1999

PARTS CATALOG MXZ-3C54VA - E1 MXZ-3C68VA - E1 MXZ-4C71VA - E1 MXZ-4C80VA - E1 MXZ-5C100VA - E1 MXZ-6C120VA - E1 OUTDOOR UNIT. No. OBB584 HFC.

SUBMITTAL DATA: MXZ-3C30NA MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM

REPAIR PARTS. GPC15 Horizontal Package Cooling Units

PARTS MANUAL Gas Furnace F8MXN, F8MXL, G8MXN, G8MXL

R- 410A R-22 Size (tons) Shipping Weight (lbs) WLAU184AA 1-1/ WLAU182AA 1-1/ WLAU244AA. Model /2

REPAIR PARTS. *PD14 Dual Fuel Package Units

REPAIR PARTS 14 SEER DUEL FUEL PACKAGE MODELS

Product Data CNPVP, CNPVT, CNPVU, CNRVU EVAPORATOR COIL N COIL - CASED AND UNCASED UPFLOW, DOWNFLOW

REPAIR PARTS. DP13CH Residential Package Heat Pump

BV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

nufacturing Company, L.P San Felipe, Suite 500

PARTS CATALOG. No. OBB702 REVISED EDITION-C. Models

REPAIR PARTS. APG10*A 10 SEER Package Gas Unit

Parts Manual R410A Models

PARTS CATALOG MUZ-FE09NA MUZ-FE09NA - 1 MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBB543 REVISED EDITION-C.

McQuay Climate Control Singer

Intuitive air velocity and IAQ.

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

REPAIR PARTS. GMV9* Variable Speed Furnace

ISM Evolution. Elscolab. Nederland BV

REPAIR PARTS. DZ13SA Remote Heat Pumps (3-Phase) DZ13SA0363AA DZ13SA0483AA DZ13SA0484AA DZ13SA0603AA DZ13SA0604AA

REPAIR PARTS. [A/G]PG15 Package Gas-Electric Units

nufacturing Company, L.P San Felipe, Suite 500

MOTORIZED 3-WAY VALVE APPLICATION INSTRUCTIONS FOR LOW TEMPERATURE PROTECTION KIT MODELS PB AND CF/CH

Parts List, Wiring Diagrams

REPAIR PARTS. *MVC95 Variable Speed Furnace

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

REPAIR PARTS. ASX16 Remote Condensing Unit

REPAIR PARTS. SSZ14 R-410A Remote Heat Pumps

REPAIR PARTS. AMH95 Amana brand 95% Hybrid Furnace AMH950453BXAA AMH950703BXAA AMH950704CXAA AMH950904CXAA AMH950905DXAA AMH951155DXAA

REPAIR PARTS. GPC14 H-Series Package Cooling Units. This manual is to be used by qualified technicians only. This manual replaces RP-622C.

REPAIR PARTS. GSZ 13 SEER R410A Remote Heat Pumps

Data Center Solutions: OASIS Indirect Evaporative Cooler. Craig MacFadyen EMEA & APAC Technical Sales Manager Data Center Solutions

REPAIR PARTS. *MVM96 Variable Speed Furnace

Goodman Manufacturing Company, L.P San Felipe, Suite 500 Houston, TX 77056

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Transcription:

ClimateMaster s Tranquility 22 Raj Hiremath Director of Residential Marketing 1

CLIMATEMASTER Industry leader since 1950 s First to introduce 2-stage 27 EER unit First to introduce Outdoor split system with internal pumping components NOW, again first to introduce FULLY communicating controls AND VARIABLE SPEED internal water flow control options 2

NEEDS Consumers Dealers Comfort Low operating cost Environmentally friendly / Efficient First cost Sell-ability / Consumer interest Reliable Easy to install Easy to service Leverage new, cost effective technology to deliver solutions to satisfy these needs 3

GEOTHERMAL PRODUCT INSTALLATION Ground Closed Loop Applications Ground Water (open) Loop Applications Flow Center Water control valve Flow regulator 4

CHALLENGES WITH CURRENT TECHNOLOGY Additional space for flow controller / outside valves Fixed speed water flow for two stage units (not optimized) Wasted pump energy in fixed speed, mismatched pumps Higher cost to achieve 2-stage compressor / Variable speed airflow One-way archaic communication between thermostat and unit 5

TRANQUILITY SERIES Complete product-line Packaged systems FORCED AIR (WATER TO AIR) HYDRONIC (WATER TO WATER) Medium temperature Tranquility 27 2-stage Tranquility 22 2-stage Tranquility 20 1-stage Tranquility Medium Temperature Split systems High temperature Compressor section Indoor section Tranquility Indoor Tranquility Outdoor Tranquility Air Handler Tranquility Cased evap coil Tranquility High Temperature 6

TRANQUILITY 22 DIGITAL 7

TRANQUILITY 22 DIGITAL Up to 22 EER / 4.1 COP (qualifies for Federal Tax Credit) Competitive pricing Compact Plug-and-play water flow Two-way communication between thermostat and unit 2-stage compressor & ECM motor are standard Energy Star qualifying warranty 8

NEW TECHNOLOGY PLUG & PLAY Internal Variable Speed Flow Controller Variable speed pump Internal Motorized Modulating Valve Motorized modulating valve Internal variable speed flow-matches with two stage operation Ideal for closed loop applications Space / time saving (no external FC) Controlled by ΔT Flush valves on front of unit inside panel Expansion tank to avoid flat loops Internal motorized modulating valve matches with two stage operation Ideal for open loop applications and multiunit applications with central pump Time saving Controlled by ΔT 9

NEW TECHNOLOGY COMMUNICATION BEFORE NOW Fan motor Up to 14 Wires Up to 14 Wires Fan motor 4 Wires No board 4 Wires old C / DXM control old non-communicating thermostat New C / DXM2 control New communicating thermostat 10

NEW TECHNOLOGY COMMUNICATION Higher intelligence and control Configuration, Monitoring, & Diagnostics ON THERMOSTAT Configure and display operation / fault data at digital thermostat Integrated ECM control and safeties Plug & play internal variable speed water flow control enabled No need to rely on flashing LEDs, guessing dip-switches to diagnose and configure units

NEW TECHNOLOGY COMMUNICATION Configure Monitor Diagnose Fan CFM Water target ΔT Water GPM Water temperature Air temperature Enhanced Fault codes on thermostat Fault code history on thermostat A I R F L O W S E L E C T I O N C F M H E A T S T A G E 1 6 0 0 H E A T S T A G E 2 7 5 0 A U X I L I A R Y H E A T 8 5 0 E M E R G E N C Y H E A T 8 5 0 C O O L S T A G E 1 5 2 5 C O O L S T A G E 2 7 0 0 C O O L D E H U M 1 4 2 5 C O O L D E H U M 2 5 5 0 C O N T I N U O U S F A N 3 5 0 H E A T O F F D E L A Y 6 0 C O O L O F F D E L A Y 3 0 P R E V I O U S N E X T Configure - example C O N T R O L S T A T U S P U M P O P E R A T I O N P U M P S P E E D 6 0 % P U M P W A T T S 1 4 0 F L O W R A T E G P M 7. 4 P R E V I O U S Monitor - example

NEW TECHNOLOGY COST REDUCTION Air Coil Water Coil Tranquility 20 Tranquility 22 Tranquility 20 Tranquility 22 25% smaller 40% smaller Efficiency Tranquility 20 Tranquility 22 Full Load EER 20.2 16.2 Part Load EER N/A 22.1 EnergyStar Tier 3 Tier 3

EASE OF INSTALL / SERVICE Small footprint, less height Swinging control board Attention to access to components Less wires Easy disconnect harnesses 14

26.3 33.5 26 30.6 SIZE 3 Ton Dimensional Comparison Height TZ 22 Base TS 20 46.5 50.5 48.4 47.5 22.4 25.4 TZ 22 TS 20 Comp. A Comp. B 22.3 Comp. A 24.25 Comp. B 15

FEATURES Comfort Efficiency Product EER / COP 2-Stage Compressor ECM Standard Filter Size EnergyStar Most Efficient Night Setback Demand Reduction TZ 22 22.0 / 4.1 Yes Yes 1 Yes Yes Yes TS 20 20.2 / 4.2 No No 2 No No No Comp A 17.3 / 3.5 No Yes 1 No No No Comp B 19.7 / 4.1 No Yes 1 No No No 16

FEATURES (cont.) Install and service Product Closed Loop Flow Controller Open Loop Water flow Control 4-Wires to T stat Configure at T stat (ΔT+CFM) Monitor at T Stat (GPM, water temp., CFM) Diagnosis at T Stat (Faults/history) TZ 22 TS 20 Comp A Comp B Internal variable speed External fixed speed External fixed speed External fixed speed Internal mot. modulating valve Yes Yes Yes Yes External No No No No External No No No No External No No No No 17

TRANQUILITY 22 DIGITAL FEATURES AND BENEFITS Price Efficiency Easy to Install & Service Lowest of ClimateMaster families and very competitive against competition Up to 22 EER / 4.1 COP Variable speed air & water flow for maximum efficiency Smallest footprint in industry Plug & Play internal variable speed waterflow Ease of access to components Easy monitoring / diagnostics at thermostat (communicating) Reliability New electronic monitoring / safeties Tin plate air-coil / stainless steel drain pan Variable speed waterflow to better match demand 18