APPLICATION OF ELECTRIC IMPEDANCE TOMOGRAPHY IN MATERIAL DISTRIBUTION MEASUREMENT IN THE PROCESS OF MAGNETIC SEPARATION

Similar documents
6 th International Conference on Electromagnetic Wave Interaction with Water and Moist Substances

Mircea cel Batran Naval Academy Scientific Bulletin, Volume XIII 2010 Published by Mircea cel Batran Naval Academy Press, Constanta, Romania

Non-Iterative Object Detection Methods in Electrical Tomography for Robotic Applications

Estimating Probability of Detection Curves Related to Eddy Current Sender Receiver Probes

The Effect of Cooling Systems on HTS Microstrip Antennas

Technique for the electric and magnetic parameter measurement of powdered materials

Model of Mass and Energy Transfer in a Clinker Rotary Kiln

ELECTRICAL AND THERMAL DESIGN OF UMBILICAL CABLE

Finite Element Modeling of Ultrasonic Transducers for Polymer Characterization

Finite element analysis of an eddy current heater for wind or water kinetic energy conversion into heat

TRAJECTORY MODELING OF A MICRO PARTICLE IN MAGNETIC FIELD FOR MAGNETIC SEPARATORS APPLICATION

Two-dimensional Tissue Image Reconstruction Based on Magnetic Field Data

A Magnetohydrodynamic study af a inductive MHD generator

PROCEEDINGS of the 5 th International Conference on Chemical Technology 5 th International Conference on Chemical Technology

Experimental study of dynamic thermal behaviour of an 11 kv distribution transformer

MAGNETIC MATERIAL CHARACTERIZATION BY OPEN SAMPLE MEASUREMENTS

Thermal Field in a NMR Cryostat. Annunziata D Orazio Agostini Chiara Simone Fiacco

Imants Matiss, Riga Technical University, Andris Purvinsh, Riga Technical University

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

THREE-DIMENSIONAL NONLINEAR INVERSION OF ELECTRICAL CAPACITANCE TOMOGRAPHY DATA USING A COMPLETE SENSOR MODEL

Optimization of two-dimensional permanent magnet arrays for diamagnetic levitation

Magnetic Drug Targeting in Cancer Therapy

Maglev by a passive HT C superconducting short runner above the magnetic guideway

we can said that matter can be regarded as composed of three kinds of elementary particles; proton, neutron (no charge), and electron.

Effusivity is defined as the square root of the product of thermal conductivity, k, density,

Study on volume reduction of cesium contaminated soil by magnetic separation

UNIVERSITY OF TRENTO MULTISCALING RECONSTRUCTION OF METALLIC TARGETS FROM TE. R. Azaro, M. Donelli, D. Franceschini, and A.Massa.

Inductance and Current Distribution Analysis of a Prototype HTS Cable

Light, Electricity and Liquids. By Vitaliy Zamsha and Vladimir Shevtsov

University Of Pennsylvania Department of Physics PHYS 141/151 Engineering Physics II (Course Outline)

THE APPROACH TO THE ANALYSIS OF ELECTRICAL FIELD DISTRIBUTION IN THE SETUP OF PAPER INSULATED ELECTRODES IN OIL

Geophysical Applications GPR Ground Penetrating Radar

&XUUHQWGLVWULEXWLRQLQVXSHUFRQGXFWLQJ GRPDLQV VXEMHFW WR WUDQVSRUW FXUUHQW DQG H[WHUQDO PDJQHWLF ILHOG 7KH HTXLYDOHQW HOHFWULFQHWZRUN

VELOCITY MEASUREMENT SIMULATIVE STUDY OF TWIN PLANE ECT USING ADVANCED CROSS CORRELATION TECHNIQUE

Dielectric properties of biological tissues at frequencies below 1 MHz. Azadeh Peyman

Operation of an Electromagnetic Trigger with a Short-circuit Ring

PHY481 - Lecture 29 Chapter 9 of PS, Chapters 6,7 of Griffiths

Expanding Your Materials Horizons

Chapter 2 Basics of Electricity and Magnetism

USAGE OF NUMERICAL METHODS FOR ELECTROMAGNETIC SHIELDS OPTIMIZATION

C80. Calvet Calorimeter From ambient to 300 C. A trademark of KEP Technologies group

Displacement Current. Ampere s law in the original form is valid only if any electric fields present are constant in time

White Paper. Perform Conductivity Measurements In Compliance with USP <645>

STRONG DOUBLE LAYER STRUCTURE IN THERMIONIC VACUUM ARC PLASMA *

B for a Long, Straight Conductor, Special Case. If the conductor is an infinitely long, straight wire, θ 1 = 0 and θ 2 = π The field becomes

Motional Electromotive Force

Capacitive Sensors for Measuring Complex Permittivity of Planar and Cylindrical Test-pieces

Development of a cryogenic induction motor for use with a superconducting magnetic bearing

CHAPTER 2. COULOMB S LAW AND ELECTRONIC FIELD INTENSITY. 2.3 Field Due to a Continuous Volume Charge Distribution

Department of Physics Preliminary Exam January 2 5, 2013

Flashover Performance of Station Post Insulators under Icing Conditions based on Electric Field Distribution

Smart Pigs. Adrian Belanger March 7,

Energy-Based Variational Model for Vector Magnetic Hysteresis

Determining the effective electromagnetic properties of negative-refractive-index metamaterials from internal fields

Feasibility Study of Capacitive Tomography

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland. First Physics at CMS

Design of a laminated-steel magnetic core for use in a HT-SMES

University of Huddersfield Repository

STUDY OF HEAT TRANSFER MECHANISMS DURING THE LENS TM PROCESS

Control Synthesis of Discrete Manufacturing Systems using Timed Finite Automata

Research and Development of Nanoparticle Characterization Methods

Evaluation of Material Plate Proprieties Using Inverse Problem NDT Techniques

Cryogenic and Electrical Test Results of a 30 M HTS Power Cable

Energy balance in self-powered MR damper-based vibration reduction system

Volume Fraction Determination of an Oil- Continuous Three Phase System using Electrical Capacitance Volume Tomography

A MAGNETOHYDRODYNAMIC STUDY OF BEHAVIOR IN AN ELECTROLYTE FLUID USING NUMERICAL AND EXPERIMENTAL SOLUTIONS

Evaluation of Capacitance in Motor Circuit Analysis Findings. Howard W Penrose, Ph.D., CMRP President, SUCCESS by DESIGN

Piezoelectric Resonators ME 2082

Applied Fluid Mechanics

CRYOGENIC CONDUCTION COOLING TEST OF REMOVABLE PANEL MOCK-UP FOR ITER CRYOSTAT THERMAL SHIELD

EDDY CURRENT DETECTION OF SUBSURFACE CRACKS IN ENGINE DISK BOLTHOLES

Applied Fluid Mechanics

ADAM PIŁAT Department of Automatics, AGH University of Science and Technology Al. Mickiewicza 30, Cracow, Poland

Digital Spectrometric System for Characterization of Mixed Neutron Gamma Field in the Experimental Reactor LR-0

THREE-DIMENSIONAL RECONSTRUCTION OF CONDUCTIVE CRACKS FROM EDDY CURRENT TESTING SIGNALS

Neural Network Modeling of Parallel-Plain Fin Heat Sink

FEATURE ARTICLE. The CS-100 Series High-precision Chemical Solution Monitor in the Semiconductor Cleaning Process. Takaaki Yada.

NONLINEAR MAGNETO-OPTICAL EFFECTS IN DIELECTRICS EMBEDDED WITH FERROMAGNETIC NANOPARTICLES

Use of Near Infrared Spectroscopy for in- and off-line performance determination of continuous and batch powder mixers: opportunities & challenges

NUMERICAL ANALYSES OF ELECTROMAGNETIC FIELDS IN HIGH VOLTAGE BUSHING AND IN ELECTROMAGNETIC FLOW METER

FINITE ELEMENT MODELING OF THE BULK MAGNITIZATION OF RAILROAD WHEELS TO IMPROVE TEST CONDITIONS FOR MAGNETOACOUSTIC

Numerical Simulation Modelling for Velocity Measurement of Electromagnetic Flow Meter

Sensitivity Analysis of 3D Magnetic Induction Tomography (MIT)

Assessing COMSOL Performances on Typical Electromagnetic Problems Faced by Turbo-Generator Manufacturers

Experimental investigation of the variation of HFE electric properties with temperature

3. Detector Systems. This chapter describes the CANDU detector systems.

Design of a Superconducting Magnet for Lorentz Force Electrical Impedance Tomography (LFEIT)

Trek electrostatic voltmeters Setup, environment, working conditions

Measurement of Industrial Alcohol Concentration Capacitance Method and AIA-GA Nonlinear Correction

Agronomy Research 15(3), , 2017

On Electromagnetic-Acoustic Analogies in Energetic Relations for Waves Interacting with Material Surfaces

Forward Problem in 3D Magnetic Induction Tomography (MIT)

A Review on Gas Solid Cyclone Separator Parametric Analysis Shah Nikhil 1

IN QUALITATIVE ANALYSIS,

New Facilities for Multiphysics Modelling in Opera-3d version 16 By Chris Riley

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

Magnetic Force on a Moving Charge

THE THEORETICAL AND EXPERIMENTAL STUDY OF CLAW POLE ALTERNATORS

CFD STUDY OF MASS TRANSFER IN SPACER FILLED MEMBRANE MODULE

Modelling II ABSTRACT

Transcription:

Czech Society for Nondestructive Testing NDE for Safety / DEFEKTOSKOPIE 2012 October 30 - November 1, 2012 - Seč u Chrudimi - Czech Republic APPLICATION OF ELECTRIC IMPEDANCE TOMOGRAPHY IN MATERIAL DISTRIBUTION MEASUREMENT IN THE PROCESS OF MAGNETIC SEPARATION Alicja IDZIASZEK-GONZALEZ*, Stefan WÓJTOWICZ* *Electrotechnical Institute, Warsaw, Poland Contact e-mail: gonzalez@iel.waw.pl Abstract The main objective of that work is to present a novel system solution that applies parameter control system to magnetic separator. The control system utilizes spatial distribution measurements taken by Electrical Impedance Tomography (EIT) unit. Magnetic separation is a process of material segregation based on difference in magnetic properties of materials. The key issue here is to obtain sufficiently high magnetic field and its gradient that is possible with application of superconducting magnets. The basis of superconducting technique in magnetic separation has been built for decades and is widely employed in High Gradient Magnetic Separators. The EIT is a noninvasive method of recovering electric parameters based on the electrical surface measurement. Presently some experimental projects are pursued aiming at commercial applications of proposed solution. In EIT the distribution of conductivity σ, permittivity ε and permeability µ is searched for. The EIT imaging is the solution of inverse problem, searching for parameter distribution that determines the conductivity or permittivity of investigated object. To find a general solution of that problem is difficult and cannot be obtained analytically. However it is possible to get an approximate solution based on iterative methods. The industrial applications are related to noninvasive examinations and belong to the area of process tomography. The main problem of applying tomographic imaging in magnetic separator is developing of multielectrode sensor array. The image is constructed based on measured signals coming from the sensors. The quality of image influences separation parameters in control system. The paper presents the schema of separation process control system, outline of separator device with superconducting magnetic field source and tomographic units and impedance tomography sensor. Key words: magnetic separator, Electrical Impedance Tomography, high gradient magnetic field. 1. Introduction. Separation in magnetic field characterized by high values of magnetic flux density and field gradient has been used in industry and science for several years. The progress in technologies utilizing magnetic separation is strictly correlated to achieving high fields at reasonable costs. The advances in magnetic technologies concern mainly water treatment, metal removal in food processing, kaolin decolorization in paper manufacturing industry, steel factories and power plants. High Gradient Magnetic Separation (HGMS) technique is beneficial to ore enrichment, coal desulfurization, food and pharmaceutical industries [2, 3]. The review of various DEFEKTOSKOPIE 2012 115 Defektoskopie rijen 2012.indd 115 22.10.2012, 13:49:54

separation methods are discussed in [1]. Some of the limitations for applying superconductor magnets in magnetic separation process are listed in [4, 5]. Recently, the research on separation covers diverse commercial applications [6, 7]. 2. Separation process. The principle behind magnetic separation process is to segregate materials with different magnetic characteristics. The key issue here is achieving relatively high magnetic field and field gradient. It is obtainable due to employment of superconducting magnets. The basis for their applications in high field generating have been created for decades. Separation process Transfer system A Feed transfer system A&B Separation chamber Transfer system B Speed of feed transfer control Defining of feed parameters Control of separation compartment Defining of output parameters Feed outlet control Magnetic separation control system Fig.1 Scheme of the separation process. Separation process takes place automatically if the system consists of following functional blocks: - Feed transfer to the inlet of the separation chamber; - Separation chamber that flowing feed is being separated within; - Transfer system of isolated feed; 116 DEFEKTOSKOPIE 2012 Defektoskopie rijen 2012.indd 116 22.10.2012, 13:49:54

- Measurement system of ingoing and outgoing materials; - Elements of control system of separation compartment, speed of feed transfer and isolated products - Control system of separation process. The connection between individual elements of the system is shown in Fig. 1. The indicator of the process quality is separation efficiency per unit time expressed by the following formula: where: separation mass efficiency of material A determined at the separator outlet i; portion of material A traversing per unit time measured at the separator outlet i; portion of material A traversing per unit time measured at the separator inlet; mass of material A per unit time traversing through the separator outlet i; mass of material B per unit time traversing through the separator outlet i; mass of material A traversing per unit time through the inlet; mass of material B traversing per unit time through the inlet; indicates the outlet number. Similarly, the separation efficiency indicator per unit volume and flow time can be determined. The indirectly measured values are material masses traversing in unit time and, and. Having measured the above values the separator control system adjusts the position of the separation compartment, setpoint of flow speed and its value at the outlets. 3. Electrical Impedance Tomography EIT is a noninvasive method of recovering electric parameters based on the electrical surface measurement. The parameters that space-time distribution is searching for are conductivity σ, dielectric permittivity ε oraz permeability µ. Recovering is the solution of inverse problem, i.e. searching for parameter DEFEKTOSKOPIE 2012 117 Defektoskopie rijen 2012.indd 117 22.10.2012, 13:49:54

distribution that determines electrical quantities on the periphery of an object. Finding the general solution is difficult and cannot be obtained analytically. However it is possible to get an approximate solution based on iterative methods. The industrial applications of EIT are related to noninvasive examinations and belong to the area of process tomography [10]. Feed is a mixture of components varying in electrical properties. Depending on the properties that distinguish investigated components one of the investigation method is chosen. The inlet and outlet sensors are disposed on the periphery of the separator chamber that has been depictured in Fig. 2. Paramagnetic particles (in red) response to high gradient magnetic field in the separation zone of the chamber. Diamagnetic parts (in blue) are passing through that zone practically not reacting to the field. The EIT inlet sensor registers spatial distribution of impedance before the feed enters the separation zone. Based on multielectrode sensor measurements the value of is found. The spatial impedance distribution is characterized by the relationship developed in calibration process. Inlet EIT inlet sensor Separation chamber Separation zone Superconducting magnet EIT outlet sensor Fig.2 Separation chamber with indication of EIT sensor location 118 DEFEKTOSKOPIE 2012 Defektoskopie rijen 2012.indd 118 22.10.2012, 13:49:54

The EIT outlet placed below the separation zone measures impedance in multielectrode system using the data acquisition algorithm. The obtained spatial distribution of impedance parameters is the basis for distribution reconstruction of material A content. Through comparing and contrasting the inlet distribution with inlet feed contents the feed composition at every stage of the procedure is specified. The sensor design is described elsewhere [8, 9]. The material distribution image is created after registering the sensor signals. The image quality influences separation parameters in the control system. 4. Experimental setup for distribution measurement. The separation chamber is cylinder-shaped (Fig.3, a). Superconducting magnets generate axially symmetric field. Considering the mixing process that takes place in the separation zone material distribution at the inlet is uniform (level y 1 ). That has been shown in Fig. 3, where x denotes an axis parallel to the diameter of the cylinder. m m1+m2 y m1 m2 x y m1+m2 y 1 m1 b) m m2 m1+m2 y 2 m1 x=s m x s m2 x z a) c) d) Fig. 3 Feed content distribution. a) Geometry of separation chamber; b) Feed content distribution at the inlet level; c) Feed content distribution at the outlet level; d) Feed content distribution as a function of separation distance. DEFEKTOSKOPIE 2012 119 Defektoskopie rijen 2012.indd 119 22.10.2012, 13:49:54

The components of the mixture can be two substances that masses are denoted as m 1 and m 2 (blue and red colored). The distribution of flowing substance is described by the function along the radius at the outlet level (level y 2 ). The function needs to be a good approximation of experimental data. The model parameters are identified for specific application. One can write: where: scalar components of identified model parameters; scalar components of control system setting; - scalar components of incoming quantities ; scalar components of confounders; An analytical form of function is fitted arbitrarily and the parameters are determined as a result of parametric identification of the model for a given model structure. Next, the parameters are calculated by optimization method as a sufficiently close approximation of data measured by EIT method. 5. Control system. Tomographic measurements are taken sequentially on input and output of the chamber. Next, the input data taken at the input are processed to get the boundary parameters of the control system determined by the average feed content determines. Then, processing of the data taken at the output results in some particular functions (2). The decision on the system setting is made after integration of: (3) The following conditions are met: (4) 120 DEFEKTOSKOPIE 2012 Defektoskopie rijen 2012.indd 120 22.10.2012, 13:49:55

where: position of separation compartment ; initial speed of feed movement; - integral s value of distribution function of material A over the interval s (0,s); - minimal value of integral ; - maximal value of integral; - maximal speed of feed movement; - minimal change of feed transfer speed; - minimal change in compartment s position. The control process is determined by given experimental data, separator s setup and a priori characteristics of the separator and feed. The conditions (4) constitute noncomplicated schema of controlling that needs to be specified in laboratory or industrial conditions. First of all the arguments of function (2) are considered; i.e. parameter accuracy of component distribution function, initial quantities, confounders and their mutual interaction. The accuracy, precision of the system settings, relations between the respective control system blocks need to be specified. 6. Conclusions Electrical Impedance Tomography is a powerful tool to noninvasively study distribution of mixture components. In order to achieve reliable distribution one selects an appropriate information carrier, electrical parameter related to specific material that assure detecting of separating components. Additionally, magnetic separation performed in high gradient field requires separated components have various magnetic characteristics. The key problem here is to properly design the multielectrode sensors. If the separated components are weakly conductive capacitive sensors should be used. In case of high conductance resistive sensors are employed. Application of eddy current sensors is considered if one cannot have any direct contact with feed. In practice the use of all the sensors are limited by many others factors, not mentioned here, that depends on the process. The distribution image of substances inside the chamber is a result of data processing by numerical algorithms based on the registered signals. The estimation of the distribution greatly influences separation parameters in control system. The paper present the schema DEFEKTOSKOPIE 2012 121 Defektoskopie rijen 2012.indd 121 22.10.2012, 13:49:55

of control system dedicated to magnetic separators, outline of separator device utilizing superconductive magnets and tomographic unit. In the process of magnetic separation controlled by EIT the time factor plays an important role. It is a dynamic process that implies simultaneous measurements and analysis that result in images. The employed algorithm takes into account the dynamic character of evaluated images [11] that imposes the detailed study of conditions present during separation. The described algorithm enables the time adaptive processing. The characterized system and related solutions are the subject of laboratory investigation of Measurement and Diagnostics Department of Electrotechnical Institute in Warsaw [12]. 7. References 1. C. T. Yavuz, A. Prakash, J. T. Mayo, V. L. Colvin.: Magnetic Separations: From steel plants to biotechnology, Chemical Engineering Science 64 (2009) 2510 2521. 2. S. Ergun and E.H. Bean: Magnetic Separation of Pyrite from Coals. Raport of Investigation no. 7181, U.S. Bureau of Mines, Pittsburg, September 1968. 3. E. Maxwell, D.R. Kelland: High Gradient Magnetic Separation in Coal Desulfirization. IEEE Transactions on Magnetics, vol. Mag-14, No. 5, September 1978. 4. M. Brożek, A. Cieśla, W. Pilch: Preliminary Investigation on Application of Superconducting Separator to Upgrading of Kaolin. Physical Problems of Mineral Processing, 1991, 24, 203-209. 5. T. Ohara, H. Kumakura, H. Wada: Magnetic separation using superkonducting magnets. Elsevier, Phisica C 357-360 (2001)1272-1280. 6. A. Cieśla: Practical aspects of high gradient magnetic separation using superconducting magnets. Physicochemical Problems of Mineral Processing, 37 (2003), 169-181] 7. A. Stanci, C. D. Buioca, V. Iusan: The improvement of quality of coal using magnetic separation. Applied physics electromechanics methods, Rom. Journ. Phys., Vol. 51, Nos. 1 2, P. 97 100, Bucharest, 2006. 8. B. Matusiak, A. Romanowski, K. Grudzień: Designing an electrical capacitance tomography sensor for the purpose of investigating liquid flows. Proceedings of the Electrotechnical Institute, vol. 239, 2008. 9. M. G. Rasteiro, R. Silva1, F. A. P. Garcia, P. Faia: Electrical Tomography: a review of Configurations and Applications to Particulate Processes. KONA Powder and Particle Journal No.29 (2011) s. 67-80. 10. D. Holder: Electrical Impedance Tomography: Methods, History and Applications, IOP Publishing, Bristol, UK, 2005. 11. A. Idziaszek-Gonzalez, S. Wójtowicz: Sequential measurement in optical tomography system integrated with magnetic separator. Proceedings of the Electrotechnical Institute, vol. 255, 2012. 12. A. Idziaszek-Gonzalez, S. Wójtowicz: Analysis of material separation process performed in wet drum magnetic separators. Proceedings of the VII Conference in Jamrozowa Polana 19-21. IX.2012. 122 DEFEKTOSKOPIE 2012 Defektoskopie rijen 2012.indd 122 22.10.2012, 13:49:55