Fish embryo multimodal imaging by laser Doppler digital holography

Similar documents
Direct strain and slope measurement using 3D DSPSI

Evaluation of transverse elastic properties of fibers used in composite materials by laser resonant ultrasound spectroscopy

Laser Doppler holographic microscopy in transmission: application to fish embryo imaging

Smart Bolometer: Toward Monolithic Bolometer with Smart Functions

Towards an active anechoic room

The status of VIRGO. To cite this version: HAL Id: in2p

The FLRW cosmological model revisited: relation of the local time with th e local curvature and consequences on the Heisenberg uncertainty principle

Case report on the article Water nanoelectrolysis: A simple model, Journal of Applied Physics (2017) 122,

Vibro-acoustic simulation of a car window

Methylation-associated PHOX2B gene silencing is a rare event in human neuroblastoma.

Comparison of Harmonic, Geometric and Arithmetic means for change detection in SAR time series

A new simple recursive algorithm for finding prime numbers using Rosser s theorem

Easter bracelets for years

Beat phenomenon at the arrival of a guided mode in a semi-infinite acoustic duct

STATISTICAL ENERGY ANALYSIS: CORRELATION BETWEEN DIFFUSE FIELD AND ENERGY EQUIPARTITION

Dispersion relation results for VCS at JLab

On measurement of mechanical properties of sound absorbing materials

Thomas Lugand. To cite this version: HAL Id: tel

Influence of a Rough Thin Layer on the Potential

Evolution of the cooperation and consequences of a decrease in plant diversity on the root symbiont diversity

On the longest path in a recursively partitionable graph

Optical component modelling and circuit simulation using SERENADE suite

MODal ENergy Analysis

Completeness of the Tree System for Propositional Classical Logic

Full-order observers for linear systems with unknown inputs

Interferences of Peltier thermal waves produced in ohmic contacts upon integrated circuits

Interactions of an eddy current sensor and a multilayered structure

Diurnal variation of tropospheric temperature at a tropical station

b-chromatic number of cacti

Can we reduce health inequalities? An analysis of the English strategy ( )

Water Vapour Effects in Mass Measurement

ATOMIC STRUCTURE OF INTERFACES IN GaAs/Ga1-xAlxAs SUPERLATTICES

DEM modeling of penetration test in static and dynamic conditions

Stator/Rotor Interface Analysis for Piezoelectric Motors

L institution sportive : rêve et illusion

Sound intensity as a function of sound insulation partition

Low frequency resolvent estimates for long range perturbations of the Euclidean Laplacian

Particle-in-cell simulations of high energy electron production by intense laser pulses in underdense plasmas

Passerelle entre les arts : la sculpture sonore

Soundness of the System of Semantic Trees for Classical Logic based on Fitting and Smullyan

The parametric propagation in underwater acoustics : experimental results

Analysis of Boyer and Moore s MJRTY algorithm

IMPROVEMENTS OF THE VARIABLE THERMAL RESISTANCE

Dissipation measurements during ultrasonic fatigue tests

From Unstructured 3D Point Clouds to Structured Knowledge - A Semantics Approach

Widely Linear Estimation with Complex Data

The sound power output of a monopole source in a cylindrical pipe containing area discontinuities

The magnetic field diffusion equation including dynamic, hysteresis: A linear formulation of the problem

Impulse response measurement of ultrasonic transducers

Optically Selected GRB Afterglows, a Real Time Analysis System at the CFHT

On the beam deflection method applied to ultrasound absorption measurements

LAWS OF CRYSTAL-FIELD DISORDERNESS OF Ln3+ IONS IN INSULATING LASER CRYSTALS

On Symmetric Norm Inequalities And Hermitian Block-Matrices

Finite element computation of leaky modes in straight and helical elastic waveguides

Comment on: Sadi Carnot on Carnot s theorem.

On size, radius and minimum degree

On a series of Ramanujan

RHEOLOGICAL INTERPRETATION OF RAYLEIGH DAMPING

Hook lengths and shifted parts of partitions

Structural study of a rare earth-rich aluminoborosilicate glass containing various alkali and alkaline-earth modifier cations

A Slice Based 3-D Schur-Cohn Stability Criterion

BERGE VAISMAN AND NASH EQUILIBRIA: TRANSFORMATION OF GAMES

A new approach of the concept of prime number

Radio-detection of UHECR by the CODALEMA experiment

On Poincare-Wirtinger inequalities in spaces of functions of bounded variation

Theoretical calculation of the power of wind turbine or tidal turbine

Exogenous input estimation in Electronic Power Steering (EPS) systems

Quantum efficiency and metastable lifetime measurements in ruby ( Cr 3+ : Al2O3) via lock-in rate-window photothermal radiometry

A Simple Proof of P versus NP

Detection and Survey of Interface Defects Within a Pavement Structure with Ultrasonic Pulse Echo

Electromagnetic characterization of magnetic steel alloys with respect to the temperature

Tropical Graph Signal Processing

Lorentz force velocimetry using small-size permanent magnet systems and a multi-degree-of-freedom force/torque sensor

On Newton-Raphson iteration for multiplicative inverses modulo prime powers

Computation and Experimental Measurements of the Magnetic Fields between Filamentary Circular Coils

Optical Peregrine soliton generation in standard telecommunications fiber

Gaia astrometric accuracy in the past

Near-Earth Asteroids Orbit Propagation with Gaia Observations

The beam-gas method for luminosity measurement at LHCb

Quasi-periodic solutions of the 2D Euler equation

Sensitivity of hybrid filter banks A/D converters to analog realization errors and finite word length

Solution to Sylvester equation associated to linear descriptor systems

Estimation and Modeling of the Full Well Capacity in Pinned Photodiode CMOS Image Sensors

Simulation and measurement of loudspeaker nonlinearity with a broad-band noise excitation

Prompt Photon Production in p-a Collisions at LHC and the Extraction of Gluon Shadowing

SOLAR RADIATION ESTIMATION AND PREDICTION USING MEASURED AND PREDICTED AEROSOL OPTICAL DEPTH

Mirage detection for electrochromic materials characterization. Application to iridium oxide films

Antipodal radiation pattern of a patch antenna combined with superstrate using transformation electromagnetics

On path partitions of the divisor graph

approximation results for the Traveling Salesman and related Problems

Metal-rich T-dwarfs in the Hyades cluster

Finite volume method for nonlinear transmission problems

Ultra low frequency pressure transducer calibration

Higgs searches at L3

Approximation SEM-DG pour les problèmes d ondes elasto-acoustiques

Cr3+, Nd3+ multisites, pairs and energy transfer processes in laser crystal YAlO3

Nodal and divergence-conforming boundary-element methods applied to electromagnetic scattering problems

Using multitable techniques for assessing Phytoplankton Structure and Succession in the Reservoir Marne (Seine Catchment Area, France)

Entropies and fractal dimensions

Numerical Modeling of Eddy Current Nondestructive Evaluation of Ferromagnetic Tubes via an Integral. Equation Approach

Transcription:

Fish embryo multimodal imaging by laser Doppler digital holography Nicolas Verrier, Daniel Alexandre, Pascal Picart, Michel Gross To cite this version: Nicolas Verrier, Daniel Alexandre, Pascal Picart, Michel Gross. Fish embryo multimodal imaging by laser Doppler digital holography. Signal Recovery and Synthesis, Jul 2014, Seattle United States. (Optical Society of America) OSA Technical Digest (online) 2014, paper JTu4A.7., 2014, Imaging and Applied Optics 2014,. <http://www.opticsinfobase.org/abstract.cfm?uri=srs-2014-jtu4a.7>. <10.1364/AIO.2014.JTu4A.7>. <hal-01083826> HAL Id: hal-01083826 https://hal.archives-ouvertes.fr/hal-01083826 Submitted on 18 Nov 2014 HAL is a multi-disciplinary open access archive for the deposit and dissemination of scientific research documents, whether they are published or not. The documents may come from teaching and research institutions in France or abroad, or from public or private research centers. L archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des établissements d enseignement et de recherche français ou étrangers, des laboratoires publics ou privés.

Fish embryo multimodal imaging by laser Doppler digital holography Nicolas Verrier 1, Daniel Alexandre 1, Pascal Picart 2,3, Michel Gross 1 1 Laboratoire Charles Coulomb - UMR 5221 CNRS-UM2 CC 026 Université Montpellier II Place Eugêne Bataillon 34095 Montpellier cedex, France 2 LUNAM Université, Université du Maine, CNRS UMR 6613, LAUM, Avenue Olivier Messiaen, 72085 Le Mans Cedex 9, France 3 École Nationale Supérieure d Ingénieurs du Mans, rue Aristote, 72085 Le Mans Cedex 9, France michel.gross@univ-montp2.fr Abstract: A laser Doppler imaging scheme combined to an upright microscope is proposed. Quantitative Doppler imaging in both velocity norm and direction, as well as amplitude contrast of either zebrafish flesh or vasculature is demonstrated. OCIS codes: (090.1995) Digital holography, (110.6150) Speckle imaging, (170.6480) Spectroscopy, speckle. Citation M. Gross, N. Verrier, and P. Picart, Fish embryo multimodal imaging by laser Doppler digital holography, in Imaging and Applied Optics 2014, OSA Technical Digest (online) (Optical Society of America, 2014), paper JTu4A.7. http://www.opticsinfobase.org/abstract.cfm?uri=srs-2014-jtu4a.7 Conference Paper Signal Recovery and Synthesis Seattle, Washington United States July 13-17, 2014 ISBN: 978-1-55752-308-2 Joint Poster Session (JTu4A) 1. Introduction Combination of laser Doppler holography [1] with transmission microscopy is proposed to analyze blood in fish embryos. We have adapted a laser Doppler holographic setup to a standard bio-microscope by carrying the two beams (illumination of the object and reference) with optical fibers. Multimodal acquisition and analysis of the data is made by adjusting the reference versus illumination frequency offset and the shape of the filtering zone in the Fourier space. Considering the same set of data, we have extracted amplitude contrast of the whole fish embryo, or only the moving blood vessels. Images where the flow direction is coded in RGB color are obtained. 2. Experiment Our digital holography set-up consists in a Mach-Zehnder interferometer in which the recombining cube beam splitter is angularly tilted. The interferometer is split into an injection (a) and a recombination (b) part, which are connected, using optical fibers, to a classical upright microscope (Fig.1). The injection part (Fig. 1(a)) is used to build both object illumination (field E I ) and reference (or local oscillator (LO) E LO ) beams. Phase shifting interferometry and frequency scanning of the holographic detection frequency are made possible using the heterodyne holography method [2]. The reference arm is thus frequency shifted by using two acousto-optic modulators AOM1 and AOM2, operating at a controlled angular frequency difference ω. Reference and object fields are injected into two mono-mode optical fibers. The object is imaged by a microscope objective (MO: NA= 0.25, G=10), mounted on an upright microscope (Fig. 1(b)). The illumination field (E I ) is scattered by the studied fish embryo (zebrafish) yielding the signal field (E). Signal (E) and reference (E LO ) fields are combined using an angularly tilted beam splitter cube (BS). Interferences (i.e. E + e j ωt E LO ) between both fields are recorded on a 1360 1024 pixel (6.45 µm square pitch) 12-bits CCD camera operating at ω S /(2π) 10 Hz. Recorded data are cropped to 1024 1024 for FFT (Fast Fourier Transform) calculations. All the driving signals are synchronized by a common 10 MHz clock. Figure 2 illustrates our reconstruction procedure [4, 5] with non-doppler shifted images. We have considered here four phase holograms: H = (I 0 I 2 )+ j(i 1 I 3 ) (see Fig. 2(a)) where [ I 0..I 3 are 4 successive ] camera frames. H is refocused in the objective pupil plane leading to H 1 (k x,k y ) = F H(x,y)e j k (x2 +y 2 )/2d, where F is the FFT operator, and d is the propagation distance to refocus over the pupil (Fig. 2(b)). The pupil image is then

Fig. 1. Heterodyne digital holographic microscopy experimental arrangement (a) Injection part of the interferometer. HWP: half wave plate; PBS: polarizing beam splitter; AOM1, AOM2: acousto optic modulators (Bragg cells). (b) Classical upright microscope used for the off-axis recombinaison of reference and object beams. BS: cube beam splitter; CCD: CCD camera. Fig. 2. Spatial filtering and reconstruction principle. Holograms H(x,y) (a), H 1 (k x,k y ) (b), H 2 (k x,k y ) (c) and H 3 (x,y,z = 0) (d). The display is made in arbitrary Log scale for the average intensity H X 2.

cropped and recentered leading to H 2 (k x,k y ) (Fig. 2(c)) and the complex object field H 3 (x,y,z) is extracted by H 3 (x,y,z)=f 1 [H 2 (k x,k y ) e j(k2 x +k2 y )/2z]. Due to the red blood cell (RBC) motion, the light passing through the zebrafish undergoes a Doppler shift ω D = (k S k I ).v, where k I and k S are the illumination and scattered wavevectors, and v is the velocity. To measure the Doppler shift due to scatterer motion, we have swept the detection frequency ω from 0 to 120 Hz, and calculated two-phases holograms H = I 0 I 1 for each frequency point. To assess for the norm of the velocity vector, the signal Fig. 3. Dependance of the Doppler holographic signal H 3 (x,y) 2 with the frequency offset ω = (ω LO ω I )/(2π) for different location A to F in the insert (a). Curves are drawn with linear (a) and logarithmic (b) scales. is averaged over different zones the reconstructed image. Obtained results are depicted Fig. 3 for zones labeled in the insert of Fig. 3(a). By estimating the half-width at half-maximum of each spectra, it is possible to obtain the norm of the velocity vector. Fig. 4. Fourier space reconstructed hologram H 2 (k x,k y ) made without (a) and with (b,c) selection of the scattered wave vector k S. In (b) the selected zone is oriented in x direction. In (c), three zones obtained by rotating (b) by 0 (blue), 2π/3 (green) and 4π/3 (red) are displayed. Display is made in arbitrary log scale for H 2 2. Frequency shift is(ω LO ω I )=0. In our experiment, the reference arm frequency offset ω (which is known) is close to the Doppler shift:(k S k I ).v, where k I is know (k I is parallel to the z axis), and where k S can be selected in the Fourier space (by applying mask to H 2 (k x,k y ))). Quantitative information on the velocity v can thus be obtained. This point is illustrated by Fig. 4 and Fig 5. By filtering half of the Fourier space (Fig. 4(b)), one can discriminate RBC motion along the x direction. By

rotating the filtering zone by 0 (blue), 2π/3 (green) and 4π/3 (red), one can map in false color the reconstruction space (see Fig. 4(c)). Combining the 3 reconstructed holograms (displayed in blue, green and red) for the 3 rotations Fig. 5. Colored reconstructed hologram H 3 (x,y,z= 0) made for(ω LO ω I )/(2π)=0 Hz (a), 10 Hz (b), 20 Hz (c) displayed with a color RGB Log scale for the average intensity H 3 2. of the filtering zone, one can obtain an image where the flow-direction is coded in RGB colors. This point is illustrated Fig. 5 where blood flow direction between veins and arteries can be discriminated. 3. Conclusion We have proposed an holographic laser Doppler set-up based on heterodyne digital holography working in transmission configuration, and fitted to an upright-microscope. Upon classical holographic modalities, coupling spectral broadening measurement with RGB fluid flow-direction discrimination has made possible to obtain a quantitative Doppler measurement. We acknowledge OSEO-ISI Datadiag grant, ANR Blanc Simi 10 (n. 11 BS10 015 02) grant, and Labex Numev (convention ANR-10-LABX-20) n. 2014-1-042 grant for funding. References 1. M. Atlan and M. Gross, Laser Doppler imaging, revisited, Rev. Sci. Inst. 77, 116103 116103 (2006). 2. F. Le Clerc, L. Collot, and M. Gross, Numerical heterodyne holography with two-dimensional photodetector arrays, Opt. Lett. 25, 716 718 (2000). 3. M. Atlan, M. Gross, and E. Absil, Accurate phase-shifting digital interferometry, Opt. Lett. 32, 1456 1458 (2007). 4. N. Warnasooriya, F. Joud, P. Bun, G. Tessier, M. Coppey-Moisan, P. Desbiolles, M. Atlan, M. Abboud, and M. Gross, Imaging gold nanoparticles in living cell environments using heterodyne digital holographic microscopy, Opt. Express 18, 3264 3273 (2010). 5. F. Verpillat, F. Joud, P. Desbiolles, M. Gross et al., Dark-field digital holographic microscopy for 3d-tracking of gold nanoparticles, Opt. Express 19 26044 26055 (2011).