Determination of Solubility Parameters using Inverse Gas Chromatography

Similar documents
Understanding Surface Energy

Characterization of Surface Properties of Glass Fibers by Inverse Gas Chromatography

Characterization of Surface Properties of Glass Fibers by Inverse Gas Chromatography

Determination of Carbon Fibre-Polymer Interactions by Inverse Gas Chromatography

Characterisation of Microporous Materials by Finite Concentration Inverse Gas Chromatography

Inverse Gas Chromatography

Recent advances in Inverse Gas Chromatography - IGC - measurements of HSP. RALF DUEMPELMANN, ERIC BRENDLE and STEVEN ABBOTT

DVS INTRINSIC. The easy-to-use solution to complex water sorption challenges.

Investigation of Thermodynamic Properties of Hyperbranched Poly(ester amide) by Inverse Gas Chromatography

Research Article Surface Characterization of Phenylpropanolamine Drug by Inverse Gas Chromatography

Automated multi-vapor gravimetric sorption analyzer for advanced research applications

Acid-base Polymeric Engineered Foams for Adsorption of Micro-Oil Droplets from Industrial Effluents

DVS Intrinsic Compact and Economical Dynamic Vapor Sorption System

Thermodynamic Interactions between PVA-Solvent Mixtures, by Means of Inverse Gas Chromatography Measurements

10/27/10. Chapter 27. Injector typically 50 C hotter than oven

The Vacuum Sorption Solution

Pharmaceutical Characterisation. Dr. Lidia Tajber and Dr. Krzysztof Paluch School of Pharmacy and Pharmaceutical Sciences, Trinity College Dublin

Sem /2007. Fisika Polimer Ariadne L. Juwono

GAS CHROMATOGRAPHY (GC)

Subject Index. See for options on how to legitimately share published articles.

Chapter 27: Gas Chromatography

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

Headspace Technology for GC and GC/MS: Features, benefits & applications

Chromatography. Gas Chromatography

Improving Adhesive Bonding of Composites Through Surface Characterization Using Inverse Gas Chromatography (IGC) Methods

Understanding Importance of Water Sorption Isotherm Shape, Hysteresis, and Models on Pharmaceutical Materials

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

Introduction to Gas Chromatography

Measuring TEWL or Moisture Flux Across Artificial Skin

INTERFACE PREDICTION: INVERSE GAS CHROMATOGRAPHY (IGC) AND ITS POTENTIAL APPLICATION TO FIBRE-MATRIX ADHESION PROBLEMS

APPLICATION NOTE. A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline

New ways to characterize 'hard' and 'soft' surface properties by IGC-ID. Eric BRENDLE

INVERSE GAS CHROMATOGRAPHIC MEASUREMENT OF SOLUBILITY PARAMETERS IN LIQUID CRYSTALLINE SYSTEMS

Principles of Instrumental Analysis

Instrumental Chemical Analysis

DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making

CHAPTER 6 GAS CHROMATOGRAPHY

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5


GC Instruments. GC Instruments - Sample Introduction

FACULTY OF PHARMACY. M. Pharmacy I Semester (Suppl.) Examination, November 2015 (Common To All) Subject: Pharmaceutical Analytical Techniques

Gas Chromatography. Chromatography Laboratory Course. Dr. Christian Jungnickel Chromatography Course GC September 2005

Magnitudes of Back Diffusion During Long-Term Diffusive Sampling of Volatile Organic Compounds Using Carbotrap and Chromosorb 106

Volatile organic compounds (VOCs):

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Gas Chromatography. Vaporization of sample Gas-solid Physical absorption Gas-liquid Liquid immobilized on inert solid

Ultra-Inert chemistry for Trace Level Analysis

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Thermogravimetric Analysis Advanced Techniques for Better Materials Characterisation

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

Gas Chromatography (GC)

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

Chapter 4 Polymer solutions

Development and Validation of GC-FID Method for the Quantification of N-Iodosuccinimide

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications

Application Note. Abstract. Authors. Introduction

Val Joly (16-20 June 2014)

Thermal Analysis Excellence

Particle Size Determinations: Dynamic Light Scattering: page 161 text

Ch24. Gas Chromatography (GC)

İsmet KAYA Department of Chemistry, Faculty of Sciences and Arts, Department of Chemistry, Faculty of Sciences and Arts, Received

( Gauss),, Gauss,, Giddings [1,2 ] Dose [3 ]

7 INSTRUMENTAL CHROMATOGRAPHY

Some Recent Developments in Headspace Gas Chromatography

Determination of Normal Hydrocarbons C 5 -C 18 Using Silanized Algerian Bentonite (B 1100 ) as Support in Gas Chromatographic Analysis

next generation Welcome to the Dispersion options Smarter particle sizing Your sample, expertly processed and prepared Particle size

Spectroscopy and Chromatography

EVALUATING THE SURFACE ENERGY OF SURFACE SIZED PRINTING AND WRITING PAPERS

Facilitated transport of thiophenes through Ag 2 O-filled PDMS membranes

Understanding Gas Chromatography

Liquids, Solids, and Intermolecular Forces or. Why your Water Evaporates and your Cheerios Don t. Why are molecules attracted to each other?

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Preformulation & Solid State Chemistry Services

See for options on how to legitimately share published articles.

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Selection of a Capillary

Adsorption Processes. Ali Ahmadpour Chemical Eng. Dept. Ferdowsi University of Mashhad

Journal of Chromatography A

How To Select the Correct GC Column. Simon Jones Application Engineer

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

Lack of correlation of polymer-drug dispersion stability with Hildebrand or Hansen Solubility Parameters

Study of Cellulose Interaction with Various Liquids

Lab 3 Guide: Gas Chromatography (GC) (Sept 8-14)

Chapter content. Reference

Selection of a Capillary GC Column

Design, Testing and Pharmaceutical Applications of a Gas Pressure Controller Device for Solid - Gas Microcalorimetric Titration

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

Hiden Isochema. Gravimetric Gas & Vapor Sorption Analyzers. Hiden Isochema IGA Series. Advancing Sorption Analysis

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

Experiment 6 Simple and Fractional Distillation

Gel Permeation Chromatography - GPC

Application. Gas Chromatography March 1998

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Correlation of Water Vapor Adsorption Behavior of Wood with Surface Thermodynamic Properties

Transcription:

Determination of Solubility Parameters using Inverse Gas Chromatography Anett Kondor PhD IGC-SEA Product Manager and igc Product Specialist 7 th April 017

Overview Introduction Inverse Gas Chromatography Solubility Parameter Hansen Solubility Parameter Q&A

Introduction Spectroscopic techniques will normally yield analytical information on solid state materials such as what is present, where is it present and how much is present. This data contain little, if any, thermodynamic information. The best techniques for determining surface thermodynamic and related physicochemical information about solid surfaces use vapour phase molecules as molecular probes for studying, in detail, gas-solid interactions sorption techniques. 3

Advantages Techniques that use vapour-phase probes offer a number of significant advantages over traditional analytical or spectroscopic approaches including: samples can be studied under real world conditions ambient temperature and pressure; probe molecules can be chosen with chemical properties that are appropriate or relevant to the information required or problem to be addressed and may be site specific both bulk and surface properties can be elucidated as molecular probes can diffuse into materials giving an insight into internal molecular structure; vapour-phase molecular probes are extremely sensitive probes for determining the surface chemistry at sub-monolayer coverages for particulate materials; typically, both kinetic and equilibrium thermodynamic data can be obtained using molecular probe techniques.

Sorption Instruments The two main characterization techniques in current usage that use molecular vapour sorption approaches for characterizing solid state materials are dynamic vapour sorption (DVS) and inverse gas chromatography (igc). Surface Measurement Systems (SMS) is the World Leader Company in Sorption Science. SMS produces the first commercial igc system and it is the lead company in dynamic sorption technique.

Inverse Gas Chromatography

Introduction Inverse Gas Chromatography (IGC) principles*: 1st developed in 1960 s. The igc-sea system is the first commercial inverse Gas Chromatography technique. It is specially designed to determine the surface energy heterogeneity but nevertheless suitable to measure different surface and bulk properties of solid materials such as Adsorption isotherms, Heat of sorption, Glass Transition Temperature, Solubility Parameters and so on.

Animation by L. Teng, Surface Measurement Systems IGC Principles

igc-sea Introduction Gas phase injection (like Headspace) - 1 vapor reservoirs (50 ml) Carrier gas is helium column position oven design: 0 to 150 C Background Humidity Controller Flame Ionization Detector (FID) User Friendly Control and Analysis Software Carbon fiber cotton hair granules powder medical metal implants Safety Features: Hydrogen Leak & Organic Vapor Leak Detectors

SEA Calculation theories Unique Analysis Software (Cirrus Plus) for the quick sample analysis, which contains the all methods and theories. The surface energy calculation based on surface coverage.

Properties measured by IGC-SEA The IGC-SEA provides unique access to the following physico-chemical properties of a wide range of solid materials in a controlled humidity environment: Dispersive and Polar Surface Energies Heats and Entropies of Adsorption Acid/Base Interactions BET Specific Surface Area Phase Transitions Sorption Isotherms Permeability, Solubility and Diffusion Competitive (Multicomponent) Adsorption Thermodynamic Work of Cohesion and Adhesion Surface Energy heterogeneity mapping Constantly extend the applications future applications e.g. Chemisorption

igc Principle Pack a column with the sample of interest Select probes Non-polar solvent for the dispersive interaction Polar solvents for the specific interactions Inject them at infinite and/or finite dilution From the retention time the different physicochemical properties can be determined

Benefits of igc-sea column position oven design - two sample can be prepared and can be run sequentially, automatically No need for outgassing facilities, since this will be achieved by conditioning the sample inside the column and flashing it with inert gas Easier column packing procedure due to the column is straight Precise and wide range of injectable amounts vapour phase injection not liquid Automatic injection system and automatic calculation Excellent reproducibility (RSD 1% for surface energy)

Solubility Parameter The Solubility Parameter is directly related to the cohesion energy density and therefore stability of a material: E V vap m 1/ H vap V m RT 1/ CED 1/ Applications: Drug delivery Formulation Storage stability Coatings Polymer compatibility Optimising solvent selection for nanoparticle preparation Adamska & Voelkel (005) Inverse gas chromatographic determination of solubility parameters of excipients. Int. J. Pharm., 304, p11-17.

Application of the Hildebrandt theory in combination with Flory-Huggins concept Determination of the Activity Coefficient Ώ from the ret.-volume V N Calculation of the Flory-Huggins interaction parameter χ Solubility Parameter 6 11 0 6 0 10 10 73.15 ln ln T R V B P V MW P R m N 1 1 1 ln ln m m V V D D

KappaInf/V (mol/m^3) Solubility Parameter Variation of probe molecule or temperature Solubility Plot Guilett Approach: 0-10000.00 0.003 0.004 0.005 0.006 0.007 1 RT V RT 1 1 RT S V 1-0000 -30000-40000 -50000 Water linear fit Benczedi Approach: ( / V1 ) 1 R (1/ T) 1/ -60000-70000 1/T (1/K) Solubility Parameter for Starch:.6 MPa 1/ (measured between 373 K and 433 K)

delta1²/(r*t)-kappainf/v1 (Mol/m³) Solubility Parameter Ref.: SMS IGC Application Note 18 180000 160000 140000 10000 100000 80000 60000 40000 0000 0 Solubility Parameter Plot 0 5000 10000 15000 0000 5000 363.15 linear fit Hildebrandt Sol. Parameter for PMMA: 19.08 MPa 1/ (measured at 363 K with Undecane, Decane, Nonane, Octane, Heptane, Dichloromethane, 1-Butanol, Ethyl Acetate, 1,4-Dioxane) delta1 (Pa)^½ Literature value: 17.4 1.3 MPa 1/

Hansen Solubility Parameters Dispersive component: Solvents: Alkanes T d p h d slope alkanes R T Polar component: Solvents: Aromatic hydrocarbons Ketones, Nitropropane p slope polar slope alkanes R T Hydrogen Bonding component: Solvents: Alcohols, Pyridine h slope alcohols slope alkanes R T

Hansen Solubility Parameters T d p h Hansen Total Sol. Parameter for Polymer X:.13 MPa 1/ Literature: 19.30 MPa 1/ 1 R T V 0 1 (measured at 343 K with 3 solvents)

Solubility Parameter Relationship between oral absorption in humans and solubility parameters Solubility parameter and oral absorption Martini, L. et al, Europ. J. Pharm. Biopharm. 48 (1999), 59-63 Correlation between release rate of chlorohexidine from ethylcellulose films and solubility parameters Casting solvent controlled release of chlorhexidine from ethylcellulose films prepared by solvent evaporation Jones, D. et al, Int. J. Pharm. 114 (1995), 57-61 SMS Ref.: Application Note 05 IGC Solubility Starch SMS User s Publication: Journal of Chromatography A, 116 (009) 1551 1566, A. Voelkel, Inverse gas chromatography as a source of physiochemical data K. Adamska, A. Voelkel, A. Berlinska; The solubility parameter for biomedical polymers - Application of inverse gas chromatography, Journal of Pharmaceutical and Biomedical Analysis 17 (016) 0

Thank you for your attention! Head Office: United States Office: Surface Measurement Systems, Ltd. Surface Measurement Systems, Ltd, NA 5 Wharfside, Rosemont Road 15 8th Street SW, Suite 1 London HA0 4PE, UK Allentown PA, 18103 Tel: +44 (0)0 8795 9400 Tel: +1 610 798 899 Fax: +44 (0)0 8795 9401 Fax: +1 610 798 0334 Email: science@surfacemeasurementsystems.com

Q&A Any questions or thoughts?