Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

Similar documents
Acid-Base Titration. Sample

Standardizing a Solution of Sodium Hydroxide. Evaluation copy

Conductometric Titration & Gravimetric Determination of a Precipitate

Using Conductivity to Find an Equivalence Point

Acid-Base Titration. Evaluation copy

Experimental Procedure

Conductimetric Titration and Gravimetric Determination of a Precipitate

Conductimetric Titration and Gravimetric Determination of a Precipitate

Ka of Unknown Acid In this experiment you will determine the Ka of an unknown acid by titration with the sodium hydroxide.

THE IDENTIFICATION OF A SOLID ORGANIC ACID

Our Drop Counter sensor now features housing for two electrode sensors, an anti-twist mechanism, an indicator LED and two cable guides.

Titration of Acids and Bases

Acid-Base Titration. Computer OBJECTIVES

Experiment 2: Reaction Stoichiometry by Thermometric Titration

TITRATION CURVES INTRODUCTION. Read and/or review Sections 4.10 and 16.7 in your textbook.

Shown below is a sample titration curve for a diprotic acid. Note the two equivalence points.

So, What Does it Indicate?

Acid-Base Titration. Volume NaOH (ml) Figure 1

Acid-Base ph Titration Introduction

for a Weak Acid 1-ring stand stir plate and stir bar ph Probe ml burette 1-50 ml and ml beaker Drop counter ph 7.00 buffer 0.

O H 3 O 1 1 A. O 1 1 OH (K w

Chemistry with Mr. Faucher. Acid-Base Titration

Experiment 7 Buffer Capacity & Buffer Preparation

Determining the K sp of Calcium Hydroxide

Titration of a strong acid with a strong base with Cobra4

CHM 152 updated May 2011 Lab 8: Titration curve of a Weak Acid

So, What Does it Indicate?

pka AND MOLAR MASS OF A WEAK ACID

INSTRUCTOR RESOURCES

Determination of the K a of a Weak Acid and the K b of a Weak Base from ph Measurements

ph Titration Curves You will need about 10 ml of ~6M NaOH solution and about 40 ml of each acid solution and about 1.5 grams of KHP.

Kinetics of Crystal Violet Bleaching

ph Measurement and its Applications

Chemistry Determination of Mixed Acids

# 12 ph-titration of Strong Acids with Strong Bases

LABORATORY INVESTIGATION

6 Acid Base Titration

INTRODUCTION TO ACIDS, BASES AND TITRATION

Standardization of a Primary Standard & Determination of Concentration by Acid-Base Titration

ph Titration of H 3 PO 4 Mixtures Calculation of K 1, K 2, and K 3

EXPERIMENT 15. USING CONDUCTIVITY TO LOOK AT SOLUTIONS: DO WE HAVE CHARGED IONS OR NEUTRAL MOLECULES? rev 7/09

Acid-Base Titration Curves Using a ph Meter

Experiment 8 and 9 Weak Acids and Bases: Exploring the Nature of Buffers

The Synthesis and Analysis of Aspirin

Pre-lab: Read section 9.9 (pages ) on acid-base titrations in the textbook. Complete the attached pre-lab by Tuesday, June 2.

Determination of the Equivalent Weight and Ionization Constant of a Weak Acid

Spectrophotometric Determination of pka of Phenol Red

Experiment: Titration

iworx Sample Lab Experiment GB-2: Membrane Permeability

Microscale Acid-Base Titration

#13 ph-titration of Weak Acids with Strong Bases

Energy and Energy Conversion Minneapolis Community and Tech. College Principles of Chemistry 1 v q water = m water C water T water (Equation 1)

ACID-BASE TITRATION (MICROSCALE)

GETTING THE END POINT TO APPROXIMATE. Two hours

Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE

Experiment 3: Acids, Bases, and Buffers

Experiment 7: ACID-BASE TITRATION: STANDARDIZATION OF A SOLUTION

POGIL LAB EXERCISE 15 HOW DO YOU STANDARDIZE AN ACID AND BASE?

A Study of Beer s Law Prelab

Related concepts Electrolyte, electrical conductance, specific conductance, ion mobility, ion conductivity, conductometry, volumetry.

Determination of an Equilibrium Constant

To see how this data can be used, follow the titration of hydrofluoric acid against sodium hydroxide:

CHEM Practice to be done before the lab. Experiment 9 Introduction to Volumetric Techniques II. Objectives

Acid-Base Titrations Using ph Measurements Prelab

The Determination of an Equilibrium Constant

Potentiometric measurement of ph

Experiment 20: Analysis of Vinegar. Materials:

Chemical Reactions: Titrations

HESS S LAW: ADDITIVITY OF HEATS OF REACTION

Experiment 14 It s Snow Big Deal

Determining the Concentration of a Solution: Beer s Law

ENTHALPY OF FORMATION OF MgO

Ka Acid Dissociation Constant Minneapolis Community and Technical College Principles of Chemistry II, C1152 v.1.16

Lab 5 Enthalpy of Solution Formation

TEC. Titration curves and buffering capacity with Cobra4

Acid-Base Titration Curves Using a ph Meter

Acid Base Titration Experiment ACID - BASE TITRATION LAB

Magnetic Fields. Experiment 1. Magnetic Field of a Straight Current-Carrying Conductor

Investigation #2 TEMPERATURE VS. HEAT. Part I

This lab will be conducted in groups but the lab report must be completed and submitted individually.

+ H 2 O Equation 1. + NaOH CO 2 Na

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013

Volumetric analysis involving acids and alkalis

Microscale Acid-Base Titration

Introduction. Concepts Kinetics Order of reaction Reaction rate Colorimetry. Background

EXPERIMENT 6. Properties of Buffers INTRODUCTION

Molarity of Acetic Acid in Vinegar A Titration Experiment

Titration 3: NH 3 Titrated with HCl

ELECTRICAL CONDUCTION IN SOLUTIONS

HESS S LAW: ADDITIVITY OF HEATS OF REACTION

DETERMINATION OF THE SOLUBILITY PRODUCT OF GROUPII HYDROXIDES

Exercise 2-2. Titration of a Strong Acid EXERCISE OBJECTIVES

TRATION: ANALYSIS OF VINE

Ascorbic Acid Titration of Vitamin C Tablets

Electrochemistry LEC Potentiometric ph titration (phosphoric acid in a soft drink) What you need: What you can learn about

The Determination of an Equilibrium Constant

Table of Contents. Purpose... 2 Background... 2 Prelab Questions... 3 Procedure:... 3 Calculations:... 4

1iI1E. The Determination of 0 an Equilibrium Constant [LU. Computer

Experiment C-10 Titration of a Strong Acid and a Strong Base

Titration 2: CH 3 COOH Titrated with NaOH

Transcription:

INTRODUCTION Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base Chemists frequently make use of the equivalent weight (eq. wt.) as the basis for volumetric calculations. The meaning of equivalent weight can change depending upon the type of reaction which serves as the basis for analysis, i.e., neutralization, oxidation-reduction, precipitation, or complex formation. Furthermore, it should be noted that the chemical behavior of a substance must be carefully specified if its equivalent weight is to be unambiguously defined. The equivalent weight of a substance involved in a neutralization (acid/base) reaction is defined as that weight which reacts with or contributes 1 gram formula weight of hydrogen ion in that reaction. This is discussed at some length in your textbook. In this experiment, you will be given a compound which is either a pure weak acid or a pure weak base. You are asked to determine the nature of the substance (i.e. is it an acid or a base?), its equivalent weight, and its dissociation constant. If possible, using the values you obtain and the CRC Handbook, identify your compound. REAGENTS Ethanol, phenolphthalein and methyl red indicators are provided for you. PROCEDURE 1. Obtain your unknown weak acid or base, and dry it as instructed to do so if it is a solid. 2. To determine the nature of your compound: Dissolve a small amount of your unknown in water. If you find your unknown to be rather insoluble in water, try heating the solution. If this also proves unsuccessful, you will need to switch to a 10% ethanol/water mixture. Using Litmus paper determine whether your unknown is an acid or base. Likewise, Hydrion paper may be used. 3. If your compound is a weak acid, you will need to prepare a standard (ca. 0.1M) solution of NaOH for titration. If your compound is a weak base, you will need a standard (ca. 0.1M) solution of HCl to titrate your unknown sample. 4. Perform a quick and dirty titration to get an estimate of the equivalent weight of your unknown. Weigh out a small amount (~0.5 g) of your unknown and dissolve it in 50 ml of water (or appropriate solvent) in a 250 ml Erlenmeyer flask. Add 2-3 drops of indicator (phenolphthalein for an acid, methyl red for a base), and titrate the sample to the appropriate endpoint. 5. Determination of the equivalent weight. Using the results of the quick and dirty titration, estimate the mass of unknown that would require ~40 ml of titrant to reach the endpoint. Accurately weigh out 3-4 samples of this mass of your unknown (separately). Dissolve each in 50 ml of solvent in 250-mL Erlenmeyer flasks. Add 2-3 drops of indicator, titrate and then calculate the equivalent weight of your unknown.

6. Next you will collect titration curve data to determine the dissociation constant for your unknown. You will use a computer-based data acquisition system to collect this data. The procedure below outlines the use of this system. Before acquiring the hardware for the measurement, weigh out enough (to the nearest 0.1 mg) of your unknown to require ~ 50 ml of titrant into a 250 ml beaker (not an Erlenmeyer flask!). Dissolve the sample as you found necessary before in ~100 ml of solvent. If you heat your solution, let it cool to room temperature before titrating. If you wish to use an indicator for this titration, use phenolphthalein for an acidic unknown, methyl red for one that is basic. An indicator is not essential for this titration, since you are monitoring the ph of the solution with the meter, but it is interesting to watch how the color change correlates with change in ph. 7. Procedure for using a LabQuest interface to determine titration curve and export data that can be analyzed in LoggerPro. (Portions adapted from the Vernier website). See Appendix 1 on page 5 for instructions for using a computer and LoggerPro interface for data collection. NOTE: If you are unfamiliar with the LoggerPro system, please read the Introduction to LoggerPro 3 available at chemlab.truman.edu. A. Connect the ph Sensor to CH 1 of the LabQuest interface. Lower the Drop Counter onto a ring stand and connect its cable to DIG 1. B. Turn the LabQuest on (if you have not already done so). The interface should recognize the presence of both the ph sensor and drop counter. If the sensors are not recognized, consult your instructor. C. Obtain the plastic 60 ml reagent reservoir. Close both valves by turning the handles to a horizontal position. Follow the steps below to set up the reagent reservoir for the titration. 1. Rinse the reagent reservoir with a few ml titrant. 2. Use a utility clamp to attach the reservoir to the ring stand. 3. Fill the reagent reservoir with slightly more than 60 ml of the titrant (the exact volume isn t critical. 4. Place a waste beaker beneath the tip of the reservoir and drain a small amount of the titrant into beaker so that it fills the reservoir s tip, then close both valves. D. Calibrate the drops that will be delivered from the reagent reservoir 1. From the Sensors menu on the LabQuest, choose Calibrate and select the Drop Counter. 2. Place a 10 ml graduated cylinder directly below the slot on the Drop Counter, lining it up with the tip of the reagent reservoir. 3. Open the bottom valve on the reagent reservoir (vertical). Keep the top valve closed (horizontal). Tap Calibrate Now.

4. Slowly open the top valve of the reagent reservoir so that drops are released at a slow rate (~1 drop every second or two). You should see the drops being counted on the LabQuest screen. If you don t see this, consult your instructor. 5. When the volume of the titrant solution in the graduated cylinder is between 9 ml and 10 ml, close the bottom valve of the reagent reservoir. 6. Enter the precise volume of titrant solution (read to the nearest 0.1 ml) in the edit box. Also record the number of Drops/mL displayed on the screen in your notebook. Tap OK E. Calibrate the ph sensor using two ph buffers (7 and 4 if titrating with base or 7 and 10 if titrating with acid) 1. From the Sensors menu on the LabQuest, select Calibrate and choose the ph Sensor. 2. Immerse the ph Sensor in the ph 7 buffer. Tap Calibrate Now. Observe the value under Live voltage, once it has stabilized, enter 7.00 for Value 1 and tap Keep 3. Remove the ph sensor from the ph 7 buffer, rinse it with distilled water, and immerse it into the second buffer.. Observe the value under Live voltage, once it has stabilized, enter the corresponding ph for Value 2 and tap Keep 4. Tap OK to exit the calibration routine. The ph sensor is now ready for use. It should be removed from the buffer solution and placed into your unknown solution. F. Assemble the apparatus 1. Place the magnetic stirrer on the base of the ring stand. 2. Insert the ph Sensor through the large hole in the Drop Counter. 3. Lift up the ph Sensor, and place the beaker containing the unknown solution onto the magnetic stirrer. Lower the ph Sensor into the beaker. 4. Place a small magnetic stir bar in the solution, making sure that it does not touch the bulb of the ph Sensor. Adjust the position of the Drop Counter as necessary. 5. Adjust the reagent reservoir so its tip is just above the Drop Counter slot. 6. Turn on the magnetic stirrer so that the stir bar is stirring at a moderate rate. G. You are now ready to begin collecting data. Tap the green Collect arrow on the bottom left of the screen. No data will be collected until the first drop goes through the Drop Counter slot. Fully open the bottom valve. The top valve should still be adjusted so drops are released at a rate of about 1 drop every 1-2 seconds. When the first drop passes through the Drop Counter slot, check the data table to see that the first data pair was recorded. H. Continue collecting data until you observe a plateau in the ph. When the reaction is complete, turn the bottom valve of the reagent reservoir to a closed (horizontal) position. Titrate until no appreciable change in ph occurs (about ph 12 if adding NaOH or ph 2 if

adding HCl). This should put you well past the end point. Tap the red Stop button on the bottom left of the screen. I. Use the LabQuest File menu to save your data on the LabQuest. For further data analysis, you will need to either e-mail the file to yourself or transfer the file to a USB thumb drive (or both if you are a little paranoid!). a. To e-mail the file to yourself, you must first log in to the wireless network. Tap on the Wi-Fi icon next to the battery icon on the bottom right of the screen. Tap on the gear icon on the top right side of the screen that appears to open the Network Settings screen. On the Network Settings screen, select the TrumanSecureWireless network and use your Truman credentials to log in. Once you are logged in, tap OK and tap the X in the connections window to return to the data screen. From the data screen, tap File and select Email and Data File. In the screen that appears, enter your e-mail address in the To field, tap Done and Send. In your inbox you should receive a message from trumalabquest@gmail.com that has the LoggerPro data file attached. b. You can also transfer the data file to a USB flash drive by inserting the drive into the USB port on the LabQuest and tapping File and Save. The screen that appears should have a USB drive icon on the top left of the screen, if it does not, be sure the USB drive has been inserted completely. Tap on the USB icon to select the flash drive and tap Save to save the file to the drive. 8. Either in LoggerPro or by exporting the data to an Excel spreadsheet (see the LoggerPro s Help menu for instructions if necessary), graph your data (ph on the Y-axis, volume of titrant on the X-Axis), and determine the end point(s). From the graph, it is possible to determine the acid dissociation constant(s), K a, or the base dissociation constant(s), K b. One useful method for doing so employs the Henderson-Hasselbach equation: ph = pk a - log ([HA]/[A - ]) or poh = pk b - log ([B]/[HB + ]) 9. Using three points on your graph, obtain an average K a or K b value. If you have not obtained a sufficient number of points near the end point, you may wish to repeat the titration since you now know the approximate location of the end point. 10. Attempt to identify your unknown, justifying your proposed compound. On your unknown cards, please report the following: a. Whether you had an acid or a base. b. Standard solution used and its molarity. c. Size of the 3 samples used for number 6. d. Each equivalent weight and the average. e. 3 K a or K b values and their average. f. Your best attempt at the identity of your compound.

APPENDIX 1: Collecting Titration Curve Data using the LoggerPro interface and a computer Procedure for using a LoggerPro interface and computer to determine titration curve. (Portions adapted from the Vernier website) NOTE: If you are unfamiliar with the LoggerPro system, please read the Introduction to LoggerPro 3 available at chemlab.truman.edu. A. Connect the ph Sensor to CH 1 of the computer interface. Lower the Drop Counter onto a ring stand and connect its cable to DIG/SONIC 1. B. Start the Logger Pro program on your computer. The software should automatically recognize the presence of the LabPro interface and indicate that by showing the LabPro icon immediately below the button bar near the top left corner of the display. C. Click on the LabPro icon (or select the LabPro by clicking on the Experiment menu and selecting Set Up Sensors). 1. In the window that opens, ensure that the ph probe and Drop Counter are mapped to their corresponding channels. If they are not, they can be mapped by clicking on the appropriate icon for the sensor and dragging it to the desired channel. D. Click on the Data Collection icon (the one that looks like a stopwatch) to bring up the data collection window. This window can also be accessed through the Experiment menu. 1. In the data collection window, click on the Mode drop down list and select Digital Events. 2. Ensure that By Pressing the Stop Button on the Toolbar is selected under End Collection 3. Click Done 4. You should now have at least one plot on the display that has ph on the y-axis and volume on the x-axis. If more than one such plot appears, it can be deleted. E. Obtain the plastic 60 ml reagent reservoir. Close both valves by turning the handles to a horizontal position. Follow the steps below to set up the reagent reservoir for the titration. 1. Rinse the reagent reservoir with a few ml titrant. 2. Use a utility clamp to attach the reservoir to the ring stand. 3. Fill the reagent reservoir with slightly more than 60 ml of the titrant (the exact volume isn t critical. 4. Place a waste beaker beneath the tip of the reservoir and drain a small amount of the titrant into beaker so that it fills the reservoir s tip, then close both valves. F. Calibrate the drops that will be delivered from the reagent reservoir

1. From the Experiment menu in LoggerPro, choose Calibrate and select the Drop Counter. 2. Place a 10 ml graduated cylinder directly below the slot on the Drop Counter, lining it up with the tip of the reagent reservoir. 7. Open the bottom valve on the reagent reservoir (vertical). Keep the top valve closed (horizontal).click the Start button. 8. Slowly open the top valve of the reagent reservoir so that drops are released at a slow rate (~1 drop every second or two). You should see the drops being counted on the computer screen. If you don t see this, consult your instructor. 9. When the volume of the titrant solution in the graduated cylinder is between 9 ml and 10 ml, close the bottom valve of the reagent reservoir. 10. Enter the precise volume of titrant solution (read to the nearest 0.1 ml) in the edit box. Also record the number of Drops/mL displayed on the screen in your notebook. G. Calibrate the ph sensor using two ph buffers (7 and 4 if titrating with base or 7 and 10 if titrating with acid) 1. From the Experiment menu in LoggerPro, select Calibrate and choose the ph Sensor. 2. Immerse the ph Sensor in the ph 7 buffer. Click Calibrate Now. The value under Reading 1 should begin to approach 7.00. Once it has stabilized, click Keep 3. Remove the ph sensor from the ph 7 buffer, rinse it with distilled water, and immerse it into the second buffer. The value in Reading 2 should approach the ph of this buffer. Once it has stabilized, click Keep 4. Click Done to exit the calibration routine. The ph sensor is now ready for use. It should be removed from the buffer solution and placed into your unknown solution. H. Assemble the apparatus 1. Place the magnetic stirrer on the base of the ring stand. 2. Insert the ph Sensor through the large hole in the Drop Counter. 3. Lift up the ph Sensor, and place the beaker containing the unknown solution onto the magnetic stirrer. Lower the ph Sensor into the beaker. 4. Place a small magnetic stir bar in the solution, making sure that it does not touch the bulb of the ph Sensor. Adjust the position of the Drop Counter as necessary. 5. Adjust the reagent reservoir so its tip is just above the Drop Counter slot. 6. Turn on the magnetic stirrer so that the stir bar is stirring at a moderate rate. I. You are now ready to begin collecting data. Click Collect. No data will be collected until the first drop goes through the Drop Counter slot. Fully open the bottom valve. The top valve should still be adjusted so drops are released at a rate of about 1 drop every 1-2

seconds. When the first drop passes through the Drop Counter slot, check the data table to see that the first data pair was recorded. J. Continue collecting data until you observe a plateau in the ph. When the reaction is complete, turn the bottom valve of the reagent reservoir to a closed (horizontal) position. Titrate until no appreciable change in ph occurs (about ph 12 if adding NaOH or ph 2 if adding HCl). This should put you well past the end point. Continue with step 8 on page 4. APPENDIX 2: ALTERNATE METHOD FOR COLLECTING TITRATION CURVE DATA Titrate the compound, following the titration with a ph meter. You will need to obtain a ph meter with an electrode and a stir bar. Consult your instructor on the proper use of the ph meter. Weigh out 1 gram (to the nearest 0.1 mg) into an appropriately sized beaker. Dissolve the sample as you found necessary before in 100-150 ml of solvent. If you heat your solution, let it cool to room temperature before titrating. If you wish to use an indicator for this titration, use phenolphthalein for an acidic unknown, methyl red for one that is basic. An indicator is not essential for this titration, since you are monitoring the ph of the solution with the meter. Titrate, recording milliliter and ph readings. It is probably best to add the titrant in ca. 1 ml increments until near the equivalent point when very small increments must be added. Be sure to allow the ph meter to equilibrate before adding the next volume of titrant. Titrate until no appreciable change in ph occurs (about ph 12 if adding NaOH or ph 2 if adding HCl). This should put you well past the end point.