OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Similar documents
INFRARED THERMOMETER Model : TM-959

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Acceleration/Velocity/Displacement VIBRATION METER

Dual laser + type K thermometer INFRARED THERMOMETER

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

VIBRATION METER. Instruction Manual.

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

InfraRed Thermometer with Laser Pointer

Mini Environmental Quality Meter

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

Bright Advance Corporation

DIGITAL THERMOMETER OPERATOR S MANUAL

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

473-SHX Dew Point Mirror

566/568. Infrared Thermometers. Getting Started

473 Dew Point Hygrometer

473 Dew Point Hygrometer

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount

O P E R A T I N G M A N U A L

INSTRUCTION MANUAL RS 51 & RS 52 DIGITAL THERMOMETER

E2T0 DVP

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

Analog - Digital multimeters

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

Minimum (-31) every 10 s -35 (-31)

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

INFRARED THERMOMETER TM0819

MN-ISO-2000FN-E. ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL

MODEL: MO Digital DC Milliohm Meter OPERATING INSTRUCTION

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual


DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

Traceable Big-Digit Type-K Thermometer Big digits are readable from 15 feet away. For additional Type-K probes, see page 41.

Nixie Clock Manuela Desktop. User Manual

DATA SHEET. Thermocouple module with digital I²C-Interface - THMOD-I²C. Characteristic features. Areas of application. Features.

Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

Infrared Hand-Held Thermometers

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

1450 First Ave. Page 1 of 10 Chippewa Falls, WI (800) or (715) Fax: (715)

Microcare LCD Solar MPPT User Documentation

Gun-Type Professional Infrared Thermometer MODEL: ST 653. Instruction Manual

Dewpoint Meter Data Sheet / Instructions

IR 80-H. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 500~1700

Temperature Measurement

iweathar EDGE V Installation Guide Copyright 2012 iweathar. All rights reserved.

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

ea980r Digital Anemometer User Manual

High Accuracy High Speed in Your Process

Data Sheet / Instructions. Dewpoint MeterO

Infrared Thermometer Model CA879

Operating Instructions for Digital Manometer. Model: MAN-SD

HD32.2 WBGT Index HD 32.2 INSTRUMENT FOR THE ANALYSIS OF THE WBGT INDEX

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

AlphaLab Gaussmeter Model VGM -- Instructions

IR/Thermistor Pen. Instruction Manual

THERMOCOUPLE CHARACTERISTICS TRAINER

HD32.2 WBGT Index HD32.3 WBGT-PMV. [ GB ] - WBGT index. - PMV index and PPD

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

Operator's Manual. optris BR 400. Calibration source

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

Circular Motion and Centripetal Force

IR 40. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 0~1000

Air velocity & IAQ measuring instruments

INE-PHS-3E ph Meter Operating Manual

RADIATION-METER TM-91/TM-92

INE-DDB-303A Portable Conductivity Meter Instruction Manual

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

Heat Meter WR 200-D. 2 temperature inputs for Pt100 in four-wire circuit. Exact calculation of the heat parameters according IAPWS-IF97

THERMYS 150. Advanced field reference thermometer / temperature calibrator

Operating Instructions 5 Day Weather Station with Color Screen Model: DG-TH8805 INDOOR UNIT

Bante210 Benchtop ph Meter Instruction Manual

optris LaserSight Operators manual

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

One-hand ph/temperature measuring instrument

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

4 - Way Acceptance Low Maintenance Easy Installation Re - Programmable Flash ROM Auto Self -Adjusting Sensor System

OPERATING INSTRUCTIONS

Instruction Manual. Solar Weather Centre With Wireless Weather Vane. Product Code: WS5056C. Solar Powered Outdoor Weather Data Collector

Air velocity & IAQ measuring instruments

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

Minute Impulse Clock Controller I01DN

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

Digital Multi-Day Max/ Min/Current Air and Soil Temperatures Protocol

BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D

One-Year Limited Warranty

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

Transcription:

3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a complex and delicate instrument, its durable structure will allow many years of use if proper operating techniques are developed. Please read the following instructions carefully and always keep this manual within easy reach. OPERATION MANUAL

TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS...2 3. FRONT PANEL DESCRIPTION... 7 3-1 Display... 7 3-2 Power On/Off Button... 7 3-3 Sensor Button ( Left Button )... 7 3-4 REL Button ( Down Button )... 7 3-5 Hold Button ( Back-light Button )...7 3-6 REC Button... 7 3-7 / Button ( Up Button )... 7 3-8 Emissivity Button ( Laser Button )...7 3-9 RS232 Output Socket...7 3-10 Battery Compartment/Cover... 7 3-11 Thermocouple (Type J/K/R/E/T) Input Socket...7 3-12 IR Sensing Head...7 3-13 Pt 100 ohm Input Socket...7 3-14 Laser Guide... 7 4. IR MEASURING PROCEDURE...8 4-1 General IR Measurement...8 4-2 Laser Target Guide... 9 4-3 Measurement Field/Distance...10 4-4 Disturbance...10 4-5 Emissivity Adjustment...11 4-6 Offset Value Adjustment... 12 4-7 Others... 13 5. THERMOCOUPLE ( Type K/J/R/E/T ) MEASURING PROCEDURE... 13 6. PT 100 ohm MEASURING PROCEDURE... 14 7. DATA HOLD, RECORD, RELATIVE, LCD BACK-LIGHT, AUTO POWER OFF DISABLE...15 8. BATTERY REPLACEMENT... 17 9. RS232 PC SERIAL INTERFACE...17 10. OPTIONAL ACCESSORIES & PROBES...18

1. FEATURES * 3 in 1, Infrared thermometer + Pt 100 ohm thermometer + Thermocouple ( Type K/J/R/E/T ) thermometer. * The best professional thermometer in the world. * Microcomputer circuit with high performance. * Wide temperature measuring range. * Build in & select button on the front panel. * 0.1 degree resolution for Pt 100 ohm & type K/J/T/E. * Data hold function for storing the desired value on display. * Memory function to record the maximum & minimum reading. * Build in a REL button, useful for relative measurement. * LCD display with back light. * Sensor select button on the front panel, easy to change different type probe. * Infrared thermometer, non-contact temperature measurement, -20 to 400 ( -4 to 752 ), precise non contact temperature measurement. * Emissivity adjustment for IR thermometer. * Laser guide for IR temperature measurement. * 4 wires PT 100 probe input, cooperate with an 0.00385 alpha coefficient, meet DIN IEC 751, high precision. * Thermocouple probe accept 5 different types : type K, type J, type R, type T, type E. * RS 232 data output, easily cooperate with computer. * Optional data acquisition software for data record. * Auto power off saves battery life. * Built-in low battery indicator. * Heavy duty & compact housing case with stand. * Operate from 006P DC 9V battery. * Patent pending in TAIWAN, CHINA, USA, GERMANY... 1

2. SPECIFICATIONS 2-1 General Specifications Display 51 mm x 32 mm supper large LCD display, 15 mm ( 0.6" ) digit size. Sensor 1. Infrared thermometer Type ( Non contact temperature measurement ) 2. Platinum Pt 100 ohm ( 0.00385 alpha coefficient, meet DIN IEC 751 ) 3. Thermocouple probe @ Thermocouple type K @ Thermocouple type J @ Thermocouple type T @ Thermocouple type E @ Thermocouple type R Functions,, Data hold, Memory ( Max., Min. ), Relative measurement, LCD back light, Emissivity adjustment (IR thermometer). Resolution 0.1 degree or 1 degree. Circuit Exclusive microcomputer circuit, the software build in linearity correction function instead of the traditional hardware circuit. Emissivity Range : 0.20 to 1.00. Adjustment Adjustment by pushing button on front panel. Laser Guide Red laser light, less than 1 mw, Meet EN60825 Probe Input Pt 100 ohm probe : Socket DIN 4 pin socket. Thermocouple couple probe : Standard 2 pin thermocouple socket. 2

Sampling Time Approx. 1 second. Hold Function To freeze the display reading value. Memory Recall Memorize the Maximum, Minimum reading. Offset Available for IR thermometer, Adjustment Pt 100 ohm & Thermocouple thermometer Adjustment by pushing button on front panel. Over Indication Show " - - - - ". Data Output RS232 PC serial interface. Power Supply Alkaline or heavy duty type, DC 9V battery, 006P, MN1604 ( PP3 ) or equivalent. Power Approx. DC 11 ma ( w/o laser light on ). Consumption Approx. DC 16 ma ( with laser light on ). * Above consumption value is caculated under the function of IR thermometer & without LCD back light. Operating 0 to 50 (32 to 122 ). Temperature Operating Less than 80% RH. Humidity Size HWD 200 x 68 x 30 mm ( 7.9 x 2.7 x 1.2 inch ). Weight 220 g/0.48 LB. Standard Operational manual... 1 PC. Accessory Optional Thermocouple couple ( Type K ) probe : & accessories Model : TP-01, TP-02A, TP-03, TP-04. Temp. Probe Pt 100 ohm probe : Model : TP-100 (Refer page 18, RS232 cable page 19 ) Model : UPCB-02 Application software, windows version. Model : SW-U101-WIN 3

2-2 Electrical Specifications A. Infrared Thermometer Resolution/ 1-20 to 400 ranges 1-4 to 752 Accuracy 3 % of reading or 3 ( 5 ), which ever is greater. * Accuracy test under the measurement range less than 300 ( 572 ). * Meter operating temp. within 23 5 & the emissivity value of measurement target set to 0.95. * Spec. tested under the 20 cm dia. black body, the measuring distance from the probe sensing Head is 30 cm. * Spec. tested under the environment RF Field Strength less than 3 V/M & frequency less than the 30 MHz only. Temp. Sensor Thermocouple pie. Emissivity * By push button. Setting Setting range : 0.20 to 1.00. * Factory preset emissivity value to 0.95, which will cover 90% of a typical application. Measurement 6 to 12 micro meter. Wave length Region Distance Factor D/S : Approx. 7:1. D - Distance, S - Spot. 4

B. Thermocouple ( type K/J/R/E/T ) Thermometer Sensor Reso- Range Accuracy Type lution Type K 0.1-50.0 to 1300.0 ( 0.2 % + 0.5 ) -50.1 to -100.0 ( 0.2 % + 1 ) 0.1-58.0 to 2372.0 ( 0.2 % + 1 ) -58.1 to -148.0 ( 0.2 % + 1.8 ) Type J 0.1-100.0 to 1150.0 ( 0.2 % + 0.5 ) -50.1 to -100.0 ( 0.2 % + 1 ) 0.1-58.0 to 2102.0 ( 0.2 % + 1 ) -58.1 to -148.0 ( 0.2 % + 1.8 ) Type T 0.1-50.0 to 400.0 ( 0.2 % + 0.5 ) -50.1 to -100.0 ( 0.2 % + 1 ) 0.1-58.0 to 752.0 ( 0.2 % + 1 ) -58.1 to -148.0 ( 0.2 % + 1.8 ) Type E 0.1-50.0 to 900.0 ( 0.2 % + 0.8 ) -50.1 to -100.0 ( 0.2 % + 1 ) 0.1-58.0 to 1652.0 ( 0.2 % + 1.5 ) -58.1 to -148.0 ( 0.2 % + 1.8 ) Type R 1 0 to 600 ( 1 % + 5 ) 601 to 1700 ( 1.5 % + 5 ) 1 32 to 1112 ( 1 % + 10 ) 1113 to 3092 ( 1.5 % + 10 ) Remark : a. Accuracy value is specified for the meter only. b. Accuracy is tested under the meter's environment temperature within 23 5. c. Linearity Correction : Memorize the thermocouple's curve into the intelligent CPU circuit, 5

C. Platinum PT 100 ohm Thermometer Resolution Range Accuracy 0.1-200.0 to 850.0 ( 0.2 % + 0.5 ) 0.1-328.0 to 1562.0 ( 0.2 % + 1.0 ) Remark : a. Accuracy value is specified for the meter only. b. Accuracy is tested under the meter's ambient temperature within 23 5. c. Linearity Correction : Memorize the Pt 100 ohm's curve into the intelligent CPU circuit. d. Pt 100 probe input, cooperate with an 0.00385 alpha coefficient, meet DIN IEC 751. e. Input socket : DIN 4 pin socket. f. 4 wires Pt 100 ohm probe ( model : PT-100 ) is optional, refer to page 18. 6

3. FRONT PANEL DESCRIPTION Fig. 1 3-1 Display 3-8 Emissivity Button 3-2 Power On/Off Button ( Laser Button ) 3-3 Sensor Button 3-9 RS232 Output Socket ( Left Button ) 3-10 Battery Compartment/Cover 3-4 REL Button 3-11 Thermocouple ( Down Button ) (Type J/K/R/E/T) Input Socket 3-5 Hold Button 3-12 IR Sensing Head ( Back light Button ) 3-13 Pt 100 ohm Input Socket 3-6 HREC Button 3-14 Laser Guide 3-7 / Button ( Up Button ) 7

4. IR MEASURING PROCEDURE 4-1 General IR Measurement Measuring consideration of the " Emissivity " All objects emit invisible energy. The amount of energy is emitted proportional to the object's temperature & its ability to emit energy. This ability is called emissvity based upon the material that object is made of and its surface roughness. Emissivity values range from 0.1 for a very reflective object to 1.00 for a black body. The probe of this IR THERMOMETER senses energy and calculates the temperature based on the amount of IR energy it receives and a factory set emissivity value is 0.95, which will cover 90% of the typical applications. However if the emissivity value of the measured material is not 0.95, then should adjust the " Emissivity Value ". The procedure of the emissivity adjustment, please refer to " 4-5 How to Calculate & Adjust the Emissivity, page 11 " 1) Power On : Power on the meter by pressing the " Power Off/On Button " ( 3-2, Fig. 1 ). The display will count down from " 99999 ", " " 88888 "... to " " 00000 ", then show the IR temperature value ( approx. room temperature value ) & the emissivity value on the right bottom corner of the LCD. 8

IR 0.95 Remark : Suppose the approx.. room temperature is 21 2) Select the " " " " display unit pressing " / Button " ( 3-7, Fig. 1 ). 3) Hold the meter, point the " IR Sensing Head " ( 3-12, Fig. 1 ) to the measured object. The meter will display the spot's temperature values. Consideration : a) The displayed value may fluctuate if the meter is shaken or suddenly stretched etc. during measurement. b) The devices automatically compensate for tempearture of the sensor influenced by the ambient temperature. When carry out the standard measurement, the device can be measured quickly for normal environment temp. changes with 23 5 For more accurate measure- ment, keep it approx. 30 min. in a new temperature. c) When low temperature objects are measured directly after high temperature objects, some time is required for the display to stabilize. 4-2 Laser Target Guide Pressing the " Laser Button " ( 3-8, Fig. 1 ) once will activate the laser light from the " Laser Guide " ( 3-14, Fig. 1 ). The Laser Target Guide is a useful tool to approximately locate the measured target of IR thermometer. 9

4-3 Measurement Field Distance/Spot ( D/S ) value The object must large than spot size calculated by the measurement Distance/Spot ratio ( Distance Factor, refer to page 4 ). For accurate measurement, a 1.5 times distance/spot size is recommended. Careful collimating is required when the object is not large enough, if the temperature of the object or a part of it is higher ( or lower ) than the ambient temperature. After the direction of the probe ( little move the probe ), the ideal collimating is obtained the display registers the maximum ( or minimum ) reading. However the emissivity of the object and its ambient must be roughly the same. 4-4 Disturbance Objects with low emissivity or objects with a low temperature but high emissivity, emit little infrared energy. Fig. 2 10

For this reason, measurement of these objects is effected by powerful infrared energy radiated from nearby objects with high emissivity or high temperature. For example, when such objects are measured in sunlight, erratic measurement happened because of powerful radiated energy from the sun and reflected by the surface of the object and received by the sensor. 4-5 Emissivity Adjustment A factory set emissivity value of 0.95, which will cover 90% of the typical applications. However to match the correct emissivity with the specific value of the object is important in order to obtain the true temperature. When the emissivity of the object is known & its value is not 0.95. It is necessary to adjust the emissivity value again. The adjustment procedures are listed as following : a) Press the " Emissivity Button " ( 3-8, Fig. 1 ) continuously for at least 2 seconds. The emissivity value will flash, then release the button. b) Use the " Down Button " ( 3-4, Fig. 1 ), " Up Button " ( 3-7, Fig. 1 ) or the " Left Button " ( 3-3, Fig. 1 ) to adjust the required emissivity value. Press the " Emissivity Button " continuously for at least 2 seconds again. The emissivity value will stop flashing. Release the button, the adjustment procedures are completely finished. 11

4-6 Offset Value adjustment Caused by the environment temperature change or other reasons... Then the measuring value may drift few degrees ( 1, 2 or 3 degrees ). If found that the measuring values exist little deviation especially when measuring the low temperature, then adjust the offset value will make the compensation & let the measured value precisely. The offset value adjustment procedures are as following : a) Use two fingers to press the " Hold Button " ( 3-5, Fig. 1 ) & " REC Button " ( 3-6, Fig. 1 ) together & not release. The small digit ( right bottom corner of LCD ) will show the same value of main LCD ( big digit ). For example : IR 21 b) Still hold on the " Hold Button " & the " REC Button ", use the " Down Button " ( 3-4, Fig. 1 ), " Up Button " ( 3-7, Fig. 1 ) to adjust the big display until the required exact environment temp. value appeared. For example : IR 21 12

Then release all buttons, the small digit display ( right bottom corner of LCD ) will disappear, the offset adjustment procedures are completely finished. For example : IR 0.95 4-7 Others a)if the meter seems to be giving incorrect reading. Then the object may exist the not correct emissivity value (0.95), then it is necessary to make the right emissivity correction. procedures ( refer 4-5 ). b) If the surface for measuring is covered by frost or other material, clean it expose the surface. c) If the surface for measuring is highly reflective, apply masking tape or apply the known " block body paint " ( such as emissivity 0.95 ). 5. THERMOCOUPLE ( Type K/J/T/E/R ) MEASURING PROCEDURE 1) After power on the meter, select the sensor type ( Type K/J/T/E/R ) by pressing " Sensor Button " ( 3-3, Fig. 1 ). The display will show the symbol of K, J, R, E, T. 2) Insert the temp. probe plug into the " Thermocouple Input Socket " ( 3-11, Fig. 1 ). 13

3) Select the " " " " display unit by pressing " / Button " ( 3-7, Fig. 1 ). 4) Display will show the temperature reading that measured from the probe. 5) Offset Value adjustment : Same as 4-6, refer to page 12. Consideration : * When insert the probe plug into the temp. input socket, please take care to observe the correct polarity. * When the probe plug is first inserted into the thermometer socket, or if the probe is changed, the plug must be allowed to stabilize at temperature of the socket, which is in thermal contact with cold junction compensation device, for greatest accuracy is to be achieved. This will take a couple of minutes and only apply if the probe plug has previously been exposed to an ambient temperature different to that thermometer. 6. PT 100 ohm MEASURING PROCEDURE 1) After power on the meter, press the " Sensor Button " ( 3-3, Fig. 1 ) until the LCD show the mark of " Pt3850 " 2) During the power on, Plug the Pt 100 temp. probe ( TP-100, optional ) into the " Pt 100 ohm Input Socket " ( 3-13, Fig. 1 ) 3) Select the " " " " display unit by pressing " / Button " ( 3-7, Fig. 1 ). 4) Display will show the temperature reading that measured from the probe. 5) Offset Value adjustment : Same as 4-6, refer to page 12. 14

7. DATA HOLD, RECORD, RELATIVE, LCD BACK LIGHT and AUTO POWER OFF DISABLE 7-1 Data Hold 1) During the measurement, pressing the " Hold Button " ( 3-5, Fig. 1 ) will freeze the measured value & the LCD will show " HOLD " symbol. 2) Press the " Hold Button " again to cancel the data hold function 7-2 Data Record ( Maximum, Minimum reading ) 1) The DATA RECORD function displays the maximum and minimum readings. To start the DATA RECORD function, press the " REC Button " ( 3-6, Fig. 1 ) once. " REC " symbol will appear on the LCD display. 2) With the " REC " symbol on the display : (a) Press the " REC Button " ( 3-6, Fig. 1 ) once, the " Max " symbol along with the maximum value will appear on the display. (b) Press the " REC Button " again, the " Min " symbol along with the minimum value will appear on the display. (c) To exit the memory record function, press the " REC Button " continuously for at least 2 seconds. The display will revert to the current reading. 7-3 Relative measurement 1) During the measurement, the circuit will memorize the last measured value if press the " REL Button " ( 3-4, Fig. 1 ) once, display will show zero value & a " REL " symbol appear on the LCD. 15

2) The new measured frequency values will deduct above memorized " Last measured values " automatically. 3) It will cancel the relative measurement function if press the " REL Button " once again, at same time the " REL " marker will disappear. Considering : When making the " Data Hold " & " Data Record " measurement, the Relative function is prohibited. 7-4 LCD Back-light Press the " Back Light Button " ( 3-5, Fig. 1 ) continuously for at least 2 seconds. The " Back-light " of LCD will light 10 seconds approximately then off automatically. 7-5 Auto Power Off disable The instrument build-in " Auto Power Shut-off " in order to prolong battery life. The meter will switch off automatically if none of the buttons are pressed within approx. 10 minutes. To disable this feature, Select the memory record function during measurement, by pressing the " REC Button " ( 3-6, Fig. 1 ). 16

8. BATTERY REPLACEMENT 1) When the left top corner of LCD display show " ", it is necessary to replace the battery. However within specification measurement may still be made for several hours after low battery indicator appears before the instrument become inaccurate. 2) Open the " Battery Cover " ( 3-10, Fig. 1 ) away from the instrument and remove the battery. 3) Install a 9 V battery ( Alkaline or Heavy duty type ) and replace the cover. 9. RS232 PC SERIAL INTERFACE The instrument features an RS232 output via 3.5 mm Terminal ( 3-9, Fig. 1 ). The connector output is a 16 digit data stream which can be utilized to the user's specific application. A RS232 lead with the following connection will be required to link the instrument with the PC serial input. Meter PC (3.5 mm jack plug) (9W 'D" Connector) Center Pin... Pin 4 Pin 2 2.2 K Ground/shield...Pin 2 Pin 5 resister 17

The 16 digit data stream will be displayed in the following format : D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 Each digit indicate the following status : D0 End Word D1 & D8 Display reading, D1 = LSD, D8 = MSD For example : If the display reading is 1234, then D8 to D1 is : 00001234 D9 Decimal Point(DP), position from right to the left 0 = No DP, 1= 1 DP, 2 = 2 DP, 3 = 3 DP D10 Polarity 0 = Positive 1 = Negative D11 & D12 Annunciator for Display = 01 = 02 D13 1 D14 4 D15 Start Word RS232 FORMAT : 9600, N, 8, 1 10. OPTIONAL ACCESSORIES & PROBES PT-100 ohm Model : TP-100 Probe * -50 to 400 (-58 to 752 ), DIN plug, 4 pins/4 wires, Class A, Cooperate with an 0.00385 alpha coefficient, * Meet DIN IEC 751. * Accuracy : (0.15 + (0.002 x T)) * Dimension Sensing head - 152 mm tube Probe length : 245 mm. 18

Thermocouple Model : TP-01 Probe * Measure Rage : -40 to 250, -40 ( Type K ) to 482. * Ultra fast response naked-bead thermocouple, general purpose application. Thermocouple Model : TP-02A Probe * Measure Range : -50 to 900, -50 ( Type K ) to 1650. * Dimension: 10 cm tube, 3.2 mm Dia. Thermocouple Model : TP-04 Probe * Measure Range : -50 to 400, -50 ( Type K ) to 752. Surface Probe * Dimension: 10 cm tube, 8 mm Dia. Thermocouple Model : TP-03 Probe * Measure Range : -50 to 1200, -50 to 2200. ( Type K ) * Size : Temp. sensing head - 15 mm Dia. Probe length : 120 mm. RS232 cable Model : UPCB-02 * RS232 cable for connecting between the meter & the computer. Software Model : SW-U101-WIN, Windows version. * Software apply as the performance of data logging system & data recorder... Carrying Case Model : CA-03, Vinyl soft carrying case. Carrying Case Model : CA-06, Hard carrying case. 19 0011-TM-2000