Accurate Quantification of Cadmium, Chromium, Mercury and Lead in Plastics for RoHS Compliance using the Agilent 7500ce ICP-MS

Similar documents
Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Examples of Method Validation Studies Conducted in Different Economies

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

Analysis of trace elements in polymer samples to ensure compliance with WEEE-RoHS standards using the Thermo Scientific icap 7200 ICP-OES

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

Analysis of domestic sludge using the Agilent 4200 MP-AES

Quantitative analysis of high purity metals using laser ablation coupled to an Agilent 7900 ICP-MS

Analysis of Arsenic, Selenium and Antimony in Seawater by Continuous-Flow Hydride ICP-MS with ISIS

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Simple and Reliable Soil Analysis using the Agilent 7800 ICP-MS with ISIS 3

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

February 20, Joe Cerniglia The International Group for Historic Aircraft Recovery (TIGHAR) Job Number: S0CHG688. Dear Joe:

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES

High-Throughput Semiquantitative Screening of Ambient Air Samples by ORS-ICP-MS and Integrated Sample Introduction System (ISIS) Application

China Soil Pollution Survey: Elemental Analysis of Soil and Sediment Digests by ICP-MS

Application note. Accurate determination of sulfur in biodiesel using Isotope Dilution-Triple Quadrupole ICP-MS (ID-ICP-QQQ) Petrochemical

Samples compliant with the WATER

á233ñ ELEMENTAL IMPURITIES PROCEDURES

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

Accurate Analysis of Trace Mercury in Cosmetics using the Agilent 8900 ICP-QQQ

DISCLAIMER: This method:

On-line isotope dilution analysis with the 7700 Series ICP-MS: Analysis of trace elements in high matrix samples

Lead isotope analysis: Removal of 204 Hg isobaric interference from 204 Pb using ICP-QQQ in MS/MS mode

Elemental analysis of river sediment using the Agilent 4200 MP-AES

Application of the Agilent 7900 ICP-MS with Method Automation function for the routine determination of trace metallic components in food CRMs

Ultra trace measurement of potassium and other elements in ultrapure water using the Agilent 8800 ICP-QQQ in cool plasma reaction cell mode

ICP-OES Application Note Number 35

Real World Analysis of Trace Metals in Drinking Water Using the Agilent 7500ce ICP-MS with Enhanced ORS Technology. Application. Authors.

Pharmacopeial Forum Vol. 36(1) [Jan. Feb. 2010] 1

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS

Rapid determination of five arsenic species in polished rice using HPLC-ICP-MS

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

Single particle analysis using the Agilent 7700x ICP-MS

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Accurate analysis of neptunium 237 in a uranium matrix, using ICP-QQQ with MS/MS

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Traceability, validation and measurement uncertainty 3 pillars for quality of measurement results. David MILDE

NATIONAL ASSOCIATION OF TESTING AUTHORITIES (NATA) REQUIREMENTS FOR ACCREDITATION OF ICP-MS TECHNIQUES

Application. Determination of Trace Metal Impurities in Semiconductor-Grade Hydrofluoric Acid. Authors. Introduction. Abstract.

A basic introduction to reference materials. POPs Strategy

Direct Analysis of Photoresist Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Application

Determination of Phosphorus and Sulfur with Dynamic Reaction Cell ICP-MS

Preparation and Certification of IRMM-081a and IRMM-086 Spike Isotopic Reference Materials

CCQM-K45: Sn in tomato paste key comparison

Direct Measurement of Trace Metals in Edible Oils by 7500cx ICP-MS with Octopole Reaction System

Autenticity control, provenance testing and fraud detection using mass spectrometry

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Agilent G2350A Atomic Emission Detector (AED)

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

Agilent ICP-MS. Fundamentals of ICP-MS Analysis and Its Applications for Low Level Elemental Determination in Cannabis

The Investigation of Fertilizer Analyses Using Microwave Digestion and the Agilent 720-ES

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

Proficiency Test Report

Techniques for the Analysis of Organic Chemicals by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

Results of the 18 th and 19 th Needle/Leaf Interlaboratory Comparison Tests

Implementing EPA Method 6020 with the Agilent ICP-MS Portfolio

Performance of the Agilent 7900 ICP-MS with UHMI for high salt matrix analysis

The Role of Proficiency Tests in the Estimation of Measurement Uncertainty of PCDD/PCDF and PCB Determination by Isotope Dilution Methods

Test Method: CPSC-CH-E

Method Validation and Accreditation

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Determination of Cadmium, Chromium and Lead in Polymers by ICP-OES Using a High Pressure Asher (HPA)

A Statistical Approach to Reporting Uncertainty

U.S. EPA SW-846 Method 6010C using the Prodigy High Dispersion ICP

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Validating performance of an Agilent 7800 ICP MS for USP <232>/<233> & ICH Q3D/Q2(R1): Elemental Impurity Analysis in Pharmaceuticals

Determination of Butyltin Compounds in Environmental Samples by Isotope Dilution GC-MS. Application. Authors. Abstract. Introduction.

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

Uncertainty of Measurement (Analytical) Maré Linsky 14 October 2015

Validation and Standardization of (Bio)Analytical Methods

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

Application of a selective extraction method. for methylmercury compound specific stable. isotope analysis (MeHg CSIA) in biological.

Rapid Detection of Americium-241 in Food by Inductively-Coupled Plasma Mass Spectrometry

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

International interlaboratory study of forensic ethanol standards

OPTIMIZING METALS SAMPLE PREP

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Transcription:

Accurate Quantification of Cadmium, Chromium, Mercury and Lead in Plastics for RoHS Compliance using the Agilent 7500ce ICP-MS Application note Environmental Author Sarah Hill and Rebeca Santamaria-Fernandez LGC Ltd. Queens Road Teddington, Middlesex, TW11 0LY UK Abstract This application note describes the quantification of cadmium, chromium, lead and mercury in plastic materials by external calibration using the Agilent 7500ce ICP-MS system equipped with an Octopole Reaction System (ORS). Isotope dilution analysis with ICP-MS was used as a confirmatory technique. Good agreement of the results obtained by the two calibration approaches was achieved. The sample digestion methodology, tuning considerations, results and uncertainty estimations are discussed. The method validated with IDMS results has potential as a fast analytical tool for compliance testing laboratories.

Introduction The Restriction of Hazardous Substances (RoHS) Directive (2002/95/EC) became influential in 2006 and places restrictions on the maximum allowable quantity of cadmium (0.01%), hexavalent chromium (0.1%), lead (0.1%) and mercury (0.1%) in all new electrical and electronic equipment [1]. The implementation of this recent EU legislation and public concern over the potential for toxic elements to be present in imported toys has put the heavy metal content of plastics into the limelight. Several other countries such as China, Japan and some states in the USA have followed the EU s lead and have introduced similar legislation. In order to facilitate international trade, there is the need for accurate methods of quantification for these regulated elements to enable importing and exporting across borders. Such methods will also help ensure that goods comply with written specifications and legal requirements. The capability of making comparable measurements in different countries is necessary to remove any technical barrier to international trade. In order to achieve this recognition of comparable measurements, National Metrology Institutes (NMIs) and designated laboratories participate in comparison studies to prove their capabilities and to provide traceability to the International System of Units (SI). NMIs and associated reference laboratories provide links to the SI for field laboratories through the availability of certified reference materials (CRMs), calibration standards and other calibration services such as reference values for proficiency testing or quality assurance schemes. In this work, an Agilent 7500ce ICP-MS has been used for the accurate quantification of chromium, cadmium, mercury and lead in plastics by external calibration following microwave acid sample digestion. Confirmation values have been obtained by isotope dilution mass spectrometry (IDMS), a highly accurate and precise method which is traceable to the SI. The results obtained by IDMS were used to validate the external calibration method, which can then be used by field laboratories. The uncertainty associated with the results of both approaches was estimated according to ISO/GUM [2] and Eurachem/CITAC [3] guidelines. Furthermore, the IDMS results were used in an international interlaboratory comparison exercise, where excellent agreement was found between the participants. Experimental Standards and Reagents High purity primary standards were used for both external calibration and IDMS, specifically: Cr NIST SRM 3112a, Cd NIST SRM 3108, Hg NIST SRM 3133 and Pb NIST SRM 981 (National Institute of Standards and Technology, Gaithersburg, USA). They were used to prepare a multielement stock standard solution in 6% nitric acid (Aristar, BDH, UK), which was diluted appropriately and used for both calibration methods, as subsequently described. All work was performed gravimetrically to ensure maximum accuracy. For external calibration, the multi-element standard stock solution containing 999.6 ng/g Cr, 74.9 ng/g Cd, 250.0 ng/g Hg and 1101.4 ng/g Pb in nitric acid was diluted to give three calibration standards plus a blank which covered the expected range for the samples and CRMs. No problems with the stability of Hg in standard nitric acid solutions were observed over the time of the study. Calibration standards were prepared from the main stock solution on the day of analysis. Moreover, sample digests were measured within a week of preparation to minimize the effect of any potential losses. Quality Control In order to assess the accuracy of the methodology, two plastic (polyethylene) CRMs were used in this work, namely BCR 680 and ERM EC681k (LGC Standards, UK). The certified values and the expanded uncertainties for these materials are given in Table 1. Additionally, a QC standard prepared from high purity metals or salts, sourced from Alfa Aesar (Heysham, UK) and Spex CertiPrep (Stanmore, UK), was prepared in 6% nitric acid at levels that matched the CRMs. Table 1 Certified Concentrations of the CRMs (µg/g ± expanded uncertainty, k=2) Cr Cd Hg Pb BCR 680 114.6 ± 2.6 140.8 ± 2.5 25.3 ± 1.0 107.6 ± 2.8 ERM EC681k 100 ± 5 137 ± 4 23.7 ± 0.8 98 ± 6 Sample Preparation Microwave digestion was employed (Multiwave 3000, Anton Paar Ltd, UK) to ensure complete dissolution of the interlaboratory comparison sample (polypropylene) and CRMs. Approximately, 0.1 g of the plastic material was weighed into a quartz weighing boat and the boat was inserted into the quartz digestion vessel. Then 6 ml of concentrated nitric acid and 2 ml hydrogen peroxide (SuperPurity, Romil, UK) were added. The microwave program used is detailed in Table 2. A 2

digested calibration standard and blank were included in each batch. After digestion, the samples were made up to 100 g with high purity water (18 MW cm, Elga-Maxima, UK). For IDMS, after weighing the sample, an appropriate amount of isotopically enriched spike was added to the boat (0.50 g for the interlaboratory comparison sample, 0.35 g for CRM) to give a gravimetric ratio of 1, before inserting into the microwave vessel and continuing as above. Table 2 The Multiwave 3000 Microwave Conditions Stage Power (W) Ramp (min) Hold (min) 1 600 5 15 2 1400 10 10 Allow to cool to room temperature 3 1400 15 30 4 0 10 10 Instrumentation An Agilent 7500ce ICP-MS instrument equipped with an Octopole Reaction System (ORS) and Integrated Sample Introduction System (ISIS) was used in this study. The Integrated Sample Introduction System (ISIS) was used in high sample throughput mode with constant flow nebulization set at 0.1 rps during the analysis and washout in order to minimize overloading of the sample introduction system and the plasma with matrix components. The effect of 40 Ar 12 C on 52 Cr, 37 Cl 16 O on 53 Cr, and 95 Mo 16 O/ 97 Mo 16 O/ 98 Mo 16 O on 111 Cd/ 113 Cd/ 114 Cd respectively were checked to ensure removal and correction of interferences. In the case of Mo, neither the samples nor CRMs contained any detectable levels, therefore mathematical correction or the use of collision gas was not necessary for the determination of Cd. As a result, Cr was measured in helium mode and Cd, Hg and Pb were monitored in standard mode. Additionally, gold was added to the rinse solution (approximately 5 µg/g) and to the internal standard used for external calibration. The use of gold shortens Hg washout time considerably, reducing the possibility of carryover. The typical instrumental operating conditions are given in Table 3. Table 3 Typical ICP-MS Operating Conditions Parameter Cr, Cd, Hg, Pb RF Power (W) 1520 Carrier gas (l/min) 0.88 Makeup gas (l/min) 0.27 Nebulizer Glass concentric, MicroMist Spray chamber Quartz, Scott Double Pass, cooled to 2 C Cones Ni Parameter Cr Cd, Hg and Pb Cell gas He None Cell gas flow rate 4.0 - (ml/min) Extract 1 (V) 2.1 2.1 KED 3 3 External Calibration Parameter Cr Cd, Hg, Pb Isotopes monitored 52 Cr, 53 Cr, 73 Ge 95 Mo, 97 Mo, 98 Mo, 103 Rh, 111 Cd, Cd, 114 Cd, 195 Pt, 199 Hg, 200 Hg, Hg, 202 Hg, 206 Pb, 207 Pb, 208 Pb Points per peak 3 3 Integration time/ 1.5 0.3 (Hg 0.6) mass (s) Repetitions 4 4 Total acquisition 100 100 time (s) IDMS Parameter Cr Cd, Hg, Pb Isotopes monitored 52 Cr, 53 Cr 98 Mo, 111 Cd, 113 Cd, 114 Cd, 199 Hg, Hg, 202 Hg, 206 Pb, 207 Pb, 208 Pb Points per peak 3 3 Integration time/ 0.3 0.3 mass (s) Repetitions 10 10 Total acquisition 402 402 time (s) For external calibration, after measuring the calibration standards, every eight samples were bracketed by blank, middle calibration standard, blank to monitor signal drift. Additionally, the calibration was repeated at the end of sample analysis. For IDMS, each sample blend was bracketed before and after with a calibration blend in the following way; reagent blanks, calibration blend, sample 1, calibration blend, sample 2, and so forth. 3

Data Treatment For external calibration, 52 Cr and 114 Cd were used for quantification whereas the isotopes were summed for both Hg and Pb. In the case of Hg, this was to improve the counting statistics due to the low ionization efficiency of this element (Equation 1). For Pb, this approach helps minimize any errors caused by variations in the natural isotopic pattern which is often observed (Equation 2). Equation 1 202 Hg = 1 199 Hg + 1 200 Hg + 1 201 Hg + 1 202 Hg Equation 2 208 Pb = 1 206 Pb + 1 207 Pb + 1 208 Pb Internal standard corrected calibrations at the beginning and end of the sequence were averaged. Regression coefficients of > 0.999 were obtained for all the elements. Method Validation by IDMS The IDMS method involves the use of an isotopically enriched standard (spike) which is added to the sample in known quantities. Typically, this is measured against the most abundant natural isotope and the spike is added in order to give a ratio of the natural isotope to the spiked isotope of 1. The concentration in the material is calculated using a calibration standard prepared in the same way as the sample. This technique is called exact matching double IDMS and LGC has developed its own protocol [4]. It has been successfully applied to a variety of elements and matrices, such as lead in wine [5], selenium in yeast supplements [6] and iodine in food products [7]. For IDMS analysis, the primary NIST standards described above were combined into one solution in 6% nitric acid to give concentrations matched to the interlaboratory comparison sample at 251.2 µg/g Cr, 32.9 µg/g Cd, 390.2 µg/g Hg and 465.2 µg/g Pb. Another mixed calibration solution was also prepared which was matched to the concentrations in the CRMs at 100.1 µg/g Cr, 137.0 µg/g Cd, 23.7 µg/g Hg and 98.6 µg/g Pb. The following enriched metals were used to prepare the spike solutions: 53 Cr at 95.74% enrichment (Oakridge National Laboratory, USA), 111 Cd at 96.5% enrichment (Oakridge National Laboratory, USA), 199 Hg enriched to 91.95% (Oakridge National Laboratory, USA) and 206 Pb NIST SRM 983 at 92.1497% enrichment (NIST, Gaithersburg, USA). The following isotope pairs were used for quantification by IDMS: 52 Cr/ 53 Cr, 114 Cd/ 111 Cd, 200 Hg/ 199 Hg and 208 Pb/ 206 Pb. The raw intensity data was exported into Excel, corrected for either the standard or procedural blank and the concentrations were calculated using the protocol described by Catterick and others [4]. As mentioned previously, natural variations in Pb isotope ratios are a source of error when using IDMS; therefore natural Pb ratios were measured in the sample, CRMs and QC standard using a multicollector ICP- MS. These experimental ratio values with their associated uncertainties were used in the IDMS calculations. Results External Calibration The results calculated using typical external calibration in accordance with UKAS accredited in-house procedures are shown in Table 4 with the estimated expanded uncertainties using a coverage factor of k = 2. This provides a level of confidence of approximately 95%. The uncertainty components include estimations of the short term precision, isotope specificity and recovery. Additionally, the instrumental limit of detection (LOD), calculated as the mean blank concentration plus three times the standard deviation (n 10), and overall method limit of quantification (LOQ), which included all dilution factors, were determined. These values are summarized in Table 4, with quality control data, presented as % recoveries, given in Table 5. Table 4. External Calibration Results for the Interlaboratory Comparison Plastic Sample, n = 3 External calibration (µg/g) 252.3 36.6 399.7 469.5 Expanded uncertainty (k=2) (µg/g) 15.1 2.9 44.0 42.3 Rel. Expanded uncertainty % (k=2) 6 8 11 9 Instrumental LOD (ng/g) 0.06 0.01 0.10 0.02 Method LOQ (µg/g) 3.7 0.8 17.2 1.3 Table 5. External Calibration Results for the Quality Control Samples (%recovery ± expanded uncertainty, k = 2) BCR 680 (n=1) 98.8 ± 5.9 101.3 ± 8.1 108.2 ± 12 99.1 ± 8.9 ERM EC681k (n=1) - 102.1 ± 8.2 107.3 ± 12 99.4 ± 8.9 Independent QC 99.6 ± 6.0 101.5 ± 8.1 102.3 ± 11 103.5 ± 10 Standard (n=1) Standard addition 100.1 ± 6.0 99.3 ± 7.9 107.9 ± 12 98.0 ± 8.8 on interlaboratory comparison sample (n=2) The results for the quality control samples by external calibration show good recoveries with respect to either certified values (Table 1) or expected concentrations and are within overlapping uncertainty ranges. 4

Validation using IDMS For the interlaboratory comparison, LGC submitted the average of nine results (three batches in triplicate) using IDMS analysis. These values, along with the expanded uncertainties (incorporating all factors from the entire procedure), are presented in Table 6. Typically the largest uncertainty contributions are attributed to the instrumental measurement of the calibration and sample blends. This was taken as the %RSD of the 10 replicate ratio measurements, which were obtained by utilizing the Custom Database function in the ChemStation software [8]. In order to calculate the contribution from the blend-to-blend variation, the standard deviation of the mean of the nine replicate samples was taken. The average recoveries of the CRMs (BCR 680 and ERM EC681k), the independent QC standard, and the standard additions are given in Table 7. Table 6. Mass Fraction Results (in µg/g) for the Interlaboratory Comparison Sample by IDMS Mean 254.5 36.00 392.0 460.4 Mean measurement uncertainty 1.8 0.36 8.3 2.5 Blend-to-blend variation 1.5 0.10 4.3 0.6 Combined standard uncertainty 2.4 0.37 9.4 2.6 Expanded uncertainty (k=2) 4.8 0.75 18.7 5.1 Expanded uncertainty % (k=2) 1.9 2.1 4.8 1.1 Table 7. Average Quality Control Results (%recovery ± expanded uncertainty, k=2) BCR 680 (n=4) 98.7 ± 3.0 100.1 ± 1.6 103.6 ± 6.5 96.9 ± 2.0 ERM EC681k (n=4) - 100.6 ± 1.5 101.4 ± 7.1 98.9 ± 2.2 Independent QC 99.0 ± 1.3 99.5 ± 1.2 99.7 ± 7.2 100.1 ± 1.9 Standard (n=4) Standard addition 99.4 ± 1.8 100.0 ± 2.0 103.1 ± 4.9 101.1 ± 1.3 on interlaboratory comparison sample (n = 2) The results for the CRMs show excellent agreement with the certified values and any deviations from 100% are within the uncertainty limits for the material and measurement uncertainty. Additionally, recoveries obtained from analysis of the QC standard (in absence of matrix) using the proposed methodology, ranged between 99.0 and 100.1%. The standard addition results suggested that there is no matrix-induced bias (within the measurement uncertainty). In order to compare the two calibration methodologies, the results for the interlaboratory comparison sample were plotted with their respective uncertainties and are presented in Figure 1. There is excellent agreement between mean values obtained using external calibration and IDMS; as expected, IDMS results showed smaller uncertainties than when using external calibration. 600 500 External calibration IDMS Furthermore, the results for the interlaboratory comparison study were collated by the organizing institute and were reported using the median and the mean absolute deviation, MADe, (where MADe=Median ( x i -X ) / 0.6745, where x i = each result; X = median of all results) due to the presence of outliers. The results are summarized in Table 8. Concentration (µg/g) 400 300 200 100 Table 8. Interlaboratory Comparison Study Results (µg/g) LGC submitted 254.5 36.00 392.0 460.4 results Study Median 252.5 36.12 387.0 466.2 Study RSD% 12.7 3.1 5.4 5.3 n 25 24 22 18 % difference 0.8 0.3 1.3 1.3 0 Figure 1. Cr Cd Hg Pb Comparison of external calibration and IDMS for the inter-laboratory comparison sample, with their respective expanded uncertainties (k=2). As it can be seen in Table 8, LGC s results showed excellent agreement with the median of the study, providing validation of the IDMS method employed at the highest level. In turn, this also shows how external calibration can be used to provide accurate results for Cr, Cd, Hg and Pb in plastics. 5

Conclusions This work has shown how the Agilent 7500ce ICP-MS with ORS can be used to obtain highly accurate and reproducible results by two different measurement approaches for the testing of RoHS compliance. The comparison between IDMS and external calibration showed excellent agreement for Cr, Cd, Hg and Pb in the plastic material. This demonstrates the equivalence of the two calibration methodologies while providing traceability to SI and international comparability. Additionally, it also proves that external calibration is sufficient for the purpose of compliance testing laboratories. Although IDMS is the method of choice for NMIs, it is an expensive and time consuming technique due to the cost of the enriched spike materials, the number of blends prepared, and the iterations performed per analyte. Furthermore, the use of the Octopole Reaction System with helium collision gas was demonstrated to remove the 40 Ar 12 C interference on 52 Cr effectively, providing highly accurate results. Acknowledgements The work described in this note was partly funded by the UK Government National Measurement Office as part of the National Measurement System Chemical & Biological Metrology Knowledge Base Programme. References 1. Directive 2002/95/EC The restriction of the use of certain hazardous substances in electrical and electronic equipment (http://eurlex.europa.eu/lexuriserv/lexuriserv.do?uri=oj:l:2003:0 37:0019:0023:EN:PDF) 2. International Standards Organisation, Guide to Expression of Uncertainty in Measurement, ISO, Geneva, 1995. 3. Eurachem/CITAC Guide: Quantifying Uncertainty in Analytical Measurement, 2nd Edition, Editors: S.L.R. Ellison, M. Rosslein & A. Williams, 2000. 4. T. Catterick, B. Fairman & C.F. Harrington; J. Anal. At. Spectrom., 1998, 13, 1009. 5. R. Hearn, R. Santamaria-Fernandez & M. Sargent; Metrologia, 2008, 45, 08001. 6. H. Goenaga-Infante, R. Sturgeon, J. Turner, R. Hearn, M. Sargent & et al.; Anal. Bioanal. Chem., 2008, 290, 629. 7. R. Santamaria-Fernandez, P. Evans, C.S.J. Wolff-Briche & R. Hearn; J. Anal. At. Spectrom., 2006, 21, 413. 8. J. Turner, Agilent ICP-MS Journal, 2007, 30, 6. Publication no: 5989-6273EN. www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., 2009 Printed in the USA December 8, 2009 5990-5059EN