Transmission Lines in the Frequency Domain

Similar documents
EECS 117 Lecture 3: Transmission Line Junctions / Time Harmonic Excitation

1.3 Sinusoidal Steady State

Berkeley. The Smith Chart. Prof. Ali M. Niknejad. U.C. Berkeley Copyright c 2017 by Ali M. Niknejad. September 14, 2017

ECE 604, Lecture 13. October 16, 2018

EE Lecture 7. Finding gamma. Alternate form. I i. Transmission line. Z g I L Z L. V i. V g - Z in Z. z = -l z = 0

TRANSMISSION LINES AND MATCHING

Scattering Parameters

Complex Numbers, Phasors and Circuits

Transmission Line Theory

ECE 5260 Microwave Engineering University of Virginia. Some Background: Circuit and Field Quantities and their Relations

Sinusoids and Phasors

ECE 107: Electromagnetism

ECE145A/218A Course Notes

How to measure complex impedance at high frequencies where phase measurement is unreliable.

Chapter 9 Objectives

Sinusoidal Steady-State Analysis

ECE357H1S ELECTROMAGNETIC FIELDS TERM TEST 1. 8 February 2016, 19:00 20:00. Examiner: Prof. Sean V. Hum

Transmission line equations in phasor form

Electric Circuit Theory

Chapter 1: Introduction: Waves and Phasors

Topic 5: Transmission Lines

Sinusoidal Steady State Analysis (AC Analysis) Part I

Imaginary Impedance Axis. Real Impedance Axis. Smith Chart. The circles, tangent to the right side of the chart, are constant resistance circles

II Transmitter and Receiver Design

Instructor s Guide Fundamentals of Applied Electromagnetics 2006 Media Edition Fawwaz T. Ulaby

EECS 117. Lecture 22: Poynting s Theorem and Normal Incidence. Prof. Niknejad. University of California, Berkeley

EE292: Fundamentals of ECE

Solutions to Problems in Chapter 6

Lecture 2 - Transmission Line Theory

Introduction to RF Design. RF Electronics Spring, 2016 Robert R. Krchnavek Rowan University

Chapter 10: Sinusoids and Phasors

Module 4. Single-phase AC Circuits

Contents. Notes based on Fundamentals of Applied Electromagnetics (Ulaby et al) for ECE331, PSU.

09/29/2009 Reading: Hambley Chapter 5 and Appendix A

ECE 391 supplemental notes - #11. Adding a Lumped Series Element

Phasors: Impedance and Circuit Anlysis. Phasors

Transmission Lines. Plane wave propagating in air Y unguided wave propagation. Transmission lines / waveguides Y. guided wave propagation

Phasor mathematics. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

Microwave Circuit Design I

arxiv: v1 [physics.acc-ph] 19 Jan 2012

Name. Section. Short Answer Questions. 1. (20 Pts) 2. (10 Pts) 3. (5 Pts) 4. (10 Pts) 5. (10 Pts) Regular Questions. 6. (25 Pts) 7.

Berkeley. Matching Networks. Prof. Ali M. Niknejad. U.C. Berkeley Copyright c 2016 by Ali M. Niknejad

Transmission lines. Shouri Chatterjee. October 22, 2014

Sinusoidal Steady-State Analysis

RLC Circuit (3) We can then write the differential equation for charge on the capacitor. The solution of this differential equation is

Name: Lab: M8 M2 W8 Th8 Th11 Th2 F8. cos( θ) = cos(θ) sin( θ) = sin(θ) sin(θ) = cos. θ (radians) θ (degrees) cos θ sin θ π/6 30

EE 40: Introduction to Microelectronic Circuits Spring 2008: Midterm 2

Some of the different forms of a signal, obtained by transformations, are shown in the figure. jwt e z. jwt z e

1 Phasors and Alternating Currents

EE292: Fundamentals of ECE

Phasor Diagram. Figure 1: Phasor Diagram. A φ. Leading Direction. θ B. Lagging Direction. Imag. Axis Complex Plane. Real Axis

CIRCUIT ANALYSIS II. (AC Circuits)

Chapter 5 Steady-State Sinusoidal Analysis

Lecture 05 Power in AC circuit

1 Chapter 8 Maxwell s Equations

SCHOOL OF MATHEMATICS MATHEMATICS FOR PART I ENGINEERING. Self-paced Course

Microwave Phase Shift Using Ferrite Filled Waveguide Below Cutoff

EE221 Circuits II. Chapter 14 Frequency Response

ECE 3300 Standing Waves

ECE 497 JS Lecture -03 Transmission Lines

LINEAR CIRCUIT ANALYSIS (EED) U.E.T. TAXILA 09

Chapter 33. Alternating Current Circuits

ECE357H1F ELECTROMAGNETIC FIELDS FINAL EXAM. 28 April Examiner: Prof. Sean V. Hum. Duration: hours

Module 4. Single-phase AC Circuits. Version 2 EE IIT, Kharagpur 1

ANTENNAS and MICROWAVES ENGINEERING (650427)

Resonant Matching Networks

Uniform Plane Waves Page 1. Uniform Plane Waves. 1 The Helmholtz Wave Equation

Radio Frequency Electronics

An op amp consisting of a complex arrangement of resistors, transistors, capacitors, and diodes. Here, we ignore the details.

f = 1 T 6 a.c. (Alternating Current) Circuits Most signals of interest in electronics are periodic : they repeat regularly as a function of time.

y(d) = j

High Speed Communication Circuits and Systems Lecture 4 Generalized Reflection Coefficient, Smith Chart, Integrated Passive Components

SINUSOIDAL STEADY STATE CIRCUIT ANALYSIS

Transmission and Distribution of Electrical Power

PHY3128 / PHYM203 (Electronics / Instrumentation) Transmission Lines

Under guidance of Joydeep Sengupta sir VNIT BT14ECE031 CHARAN SAI KATAKAM

Sinusoidal Steady-State Analysis

General Appendix A Transmission Line Resonance due to Reflections (1-D Cavity Resonances)

Prof. Anyes Taffard. Physics 120/220. Voltage Divider Capacitor RC circuits

Lecture 9 Time Domain vs. Frequency Domain

3.1 The Helmoltz Equation and its Solution. In this unit, we shall seek the physical significance of the Maxwell equations, summarized

Chapter 10: Sinusoidal Steady-State Analysis

TECHNO INDIA BATANAGAR

Review of 1 st Order Circuit Analysis

Lecture Outline. Scattering at an Impedance Discontinuity Power on a Transmission Line Voltage Standing Wave Ratio (VSWR) 8/10/2018

Circuit Analysis-III. Circuit Analysis-II Lecture # 3 Friday 06 th April, 18

4/27 Friday. I have all the old homework if you need to collect them.

REACTANCE. By: Enzo Paterno Date: 03/2013

EE221 Circuits II. Chapter 14 Frequency Response

MODULE-4 RESONANCE CIRCUITS

ECE 6340 Intermediate EM Waves. Fall Prof. David R. Jackson Dept. of ECE. Notes 7

I. Impedance of an R-L circuit.

EEE161 Applied Electromagnetics Practical Laboratory 1

Kimmo Silvonen, Transmission lines, ver

Refresher course on Electrical fundamentals (Basics of A.C. Circuits) by B.M.Vyas

Oscillations and Electromagnetic Waves. March 30, 2014 Chapter 31 1

Electric Circuits II Sinusoidal Steady State Analysis. Dr. Firas Obeidat

04-Electric Power. ECEGR 452 Renewable Energy Systems

) Rotate L by 120 clockwise to obtain in!! anywhere between load and generator: rotation by 2d in clockwise direction. d=distance from the load to the

Guided Waves. Daniel S. Weile. Department of Electrical and Computer Engineering University of Delaware. ELEG 648 Guided Waves

Transcription:

Berkeley Transmission Lines in the Frequency Domain Prof. Ali M. Niknejad U.C. Berkeley Copyright c 2016 by Ali M. Niknejad August 30, 2017 1 / 38

Why Sinusoidal Steady-State? 2 / 38

Time Harmonic Steady-State Compared with general transient case, sinusoidal case is very easy t jω Sinusoidal steady state has many important applications for RF/microwave circuits At high frequency, T-lines are like interconnect for distances on the order of λ Shorted or open T-lines are good resonators T-lines are useful for impedance matching 3 / 38

Why Sinusoidal Steady-State? Typical RF system modulates a sinusoidal carrier (either frequency or phase) If the modulation bandwidth is much smaller than the carrier, the system looks like it s excited by a pure sinusoid Cell phones are a good example. The carrier frequency is about 1 GHz and the voice digital modulation is about 200 khz(gsm) or 1.25 MHz(CDMA), less than a 0.1% of the bandwidth/carrier Even a system like WiFi grabbing multiple channels might be 80 MHz wide, so over a 5 GHz carrier, it s still a small fractional bandwidth 4 / 38

Generalized Distributed Circuit Model Z Z Z Z Z Y Y Y Y Y Z : impedance per unit length (e.g. Z = jωl + R ) Y : admittance per unit length (e.g. Y = jωc + G ) A lossy T-line might have the following form (but we ll analyze the general case) L R L R L R L R G C G C G C G C 5 / 38

Telegrapher s Eq. Again Applying KCL and KVL to a infinitesimal section v(z + δz) v(z) = Z δzi(z) i(z + δz) i(z) = Y δzv(z) Taking the limit as before (δz 0) dv dz = Zi(z) di dz = Yv(z) 6 / 38

Sin. Steady-State Voltage/Current Taking derivatives (notice z is the only variable) we arrive at d 2 v di = Z dz2 dz = YZv(z) = γ2 v(z) d 2 i dv = Y dz2 dz = YZi(z) = γ2 i(z) Where the propagation constant γ is a complex function γ = α + jβ = (R + jωl )(G + jωc ) The general solution to D 2 G γ 2 G = 0 is e ±γz 7 / 38

Lossless Lines 8 / 38

Lossless Line for Sinusoidal Steady State v(z) = V + e γz + V e γz i(z) = V + e γz V e γz Z 0 Z 0 The voltage and current are related (just as before, but now easier to derive). Z 0 = Z Y is the characteristic impedance of the line (function of frequency with loss). For a lossless line we discussed before, Z = jωl and Y = jωc. Propagation constant is imaginary γ = jωl jωc = j L C ω The characteristic impedance is real L Z 0 = C β is like the spatial frequency, also known as the wave number You might prefer to think of it in terms of wavelength λ, β = 2π λ 9 / 38

Back to Time-Domain Recall that the real voltages and currents are the R and I parts of v(z, t) = e ±γz e jωt = e jωt±βz Thus the voltage/current waveforms are sinusoidal in space and time Sinusoidal source voltage is transmitted unaltered onto T-line (with delay) If there is loss, then γ has a real part α, and the wave decays or grows on the T-line e ±γz = e ±αz e ±jβz The first term represents amplitude response of the T-line 10 / 38

Passive T-Line/Wave Speed For a passive line, we expect the amplitude to decay due to loss on the line The speed of the wave is derived as before. In order to follow a constant point on the wavefront, you have to move with velocity d (ωt ± βz = constant) dt Or, v = dz dt = ± ω β = ± 1 L C 11 / 38

Lossless T-Line Termination Z 0, β Z L z = l z =0 Okay, lossless line means γ = jβ (α = 0), and I(Z 0 ) = 0 (real characteristic impedance independent of frequency) The voltage/current phasors take the standard form v(z) = V + e γz + V e γz i(z) = V + Z 0 e γz V Z 0 e γz 12 / 38

Lossless T-Line Termination (cont) At load Z L = v(0) i(0) = V + +V V + V Z 0 The reflection coefficient has the same form Can therefore write ρ L = Z L Z 0 Z L + Z 0 v(z) = V + ( e jβz + ρ L e jβz) i(z) = V + Z 0 ( e jβz ρ L e jβz) 13 / 38

Standing Waves and VSWR 14 / 38

Power on T-Line (I) Let s calculate the average power dissipation on the line at point z Or using the general solution Z 0 P av (z) = 1 2 R [v(z)i(z) ] P av (z) = 1 V + 2 R ((e jβz + ρ L e jβz) ( e jβz ρ L 2 e jβz)) The product in the R terms can be expanded into four terms Notice that a a = 2jI(a) 1 + ρ L e 2jβz ρ L }{{ e 2jβz ρ } L 2 a a 15 / 38

Power on T-Line (II) The average power dissipated at z is therefore P av = V + 2 2Z 0 ( 1 ρl 2) Power flow is constant (independent of z) along line (lossless) No power flows if ρ L = 1 (open or short) Even though power is constant, voltage and current are not! 16 / 38

Voltage along T-Line When the termination is matched to the line impedance Z L = Z 0, ρ L = 0 and thus the voltage along the line v(z) = V + is constant. Otherwise v(z) = V + 1 + ρ L e 2jβz = V + 1 + ρ L e 2jβl The voltage magnitude along the line can be written as v( l) = V + 1 + ρ L e j(θ 2βl) The voltage is maximum when the 2βl is a equal to θ + 2kπ, for any integer k; in other words, the reflection coefficient phase modulo 2π V max = V + (1 + ρ L ) 17 / 38

Voltage Standing Wave Ratio (SWR) Similarly, minimum when θ + kπ, where k is an integer k 0 V min = V + (1 ρ L ) The ratio of the maximum voltage to minimum voltage is an important metric and commonly known as the voltage standing wave ratio, VSWR (sometimes pronounced viswar), or simply the standing wave ratio SWR VSWR = V max = 1 + ρ L V min 1 ρ L It follows that for a shorted or open transmission line the VSWR is infinite, since ρ L = 1. 18 / 38

SWR Location Physically the maxima occur when the reflected wave adds in phase with the incoming wave, and minima occur when destructive interference takes place. The distance between maxima and minima is π in phase, or 2βδx = π, or δx = π 2β = λ 4 VSWR is important because it can be deduced with a relative measurement. Absolute measurements are difficult at microwave frequencies. By measuring VSWR, we can readily calculate ρ L. 19 / 38

VSWR Impedance Measurement By measuring the location of the voltage minima from an unknown load, we can solve for the load reflection coefficent phase θ ψ min = θ 2βl min = ±π Note that v( l min ) = V + 1 + ρ L e jψ min Thus an unknown impedance can be characterized at microwave frequencies by measuring VSWR and l min and computing the load reflection coefficient. This was an important measurement technique that has been largely supplanted by a modern network analyzer with built-in digital calibration and correction. 20 / 38

VSWR Example Consider a transmission line terminated in a load impedance Z L = 2Z 0. The reflection coefficient at the load is purely real ρ L = z L 1 z L + 1 = 2 1 2 + 1 = 1 3 Since 1 + ρ L = 4/3 and 1 ρ L = 2/3, the VSWR is equal to 2. Since the load is real, the voltage minima will occur at a distance of λ/4 from the load 21 / 38

Impedance of T-Lines ( Ohm s Law in Freq Domain ) 22 / 38

Impedance of T-Line (I) We have seen that the voltage and current along a transmission line are altered by the presence of a load termination. At an arbitrary point z, wish to calculate the input impedadnce, or the ratio of the voltage to current relative to the load impdance Z L Z in ( l) = v( l) i( l) It shall be convenient to define an analogous reflection coefficient at an arbitrary position along the line ρ( l) = V e jβl V + e jβl = ρ L e 2jβl 23 / 38

Impedance of T-Line (II) ρ(z) has a constant magnitude but a periodic phase. From this we may infer that the input impedance of a transmission line is also periodic (relation between ρ and Z is one-to-one) Z in ( l) = Z 0 1 + ρ L e 2jβl 1 ρ L e 2jβl The above equation is of paramount important as it expresses the input impedance of a transmission line as a function of position l away from the termination. 24 / 38

Impedance of T-Line (III) This equation can be transformed into another more useful form by substituting the value of ρ L ρ L = Z L Z 0 Z L + Z 0 Z in ( l) = Z 0 Z L (1 + e 2jβl ) + Z 0 (1 e 2jβl ) Z 0 (1 + e 2jβl ) + Z L (1 e 2jβl ) Using the common complex expansions for sine and cosine, we have tan(x) = sin(x) cos(x) = (ejx e jx )/2j (e jx + e jx )/2 25 / 38

Impedance of T-Line (IV) The expression for the input impedance is now written in the following form Z in ( l) = Z 0 Z L + jz 0 tan(βl) Z 0 + jz L tan(βl) This is the most important equation of the lecture, known sometimes as the transmission line equation 26 / 38

Shorted Line I/V The shorted transmission line has infinite VSWR and ρ L = 1. Thus the minimum voltage V min = V + (1 ρ L ) = 0, as expected. At any given point along the transmission line v(z) = V + (e jβz e jβz ) = 2jV + sin(βz) whereas the current is given by or i(z) = V + Z 0 (e jβz + e jβz ) i(z) = 2V + Z 0 cos(βz) 27 / 38

Shorted Line Impedance (I) The impedance at any point along the line takes on a simple form Z in ( l) = v( l) i( l) = jz 0 tan(βl) This is a special case of the more general transmision line equation with Z L = 0. Note that the impedance is purely imaginary since a shorted lossless transmission line cannot dissipate any power. We have learned, though, that the line stores reactive energy in a distributed fashion. 28 / 38

Shorted Line Impedance (II) A plot of the input impedance as a function of z is shown below 10 Z in (λ/4) Z in (z) Z 0 8 6 4 2 Z in (λ/2) -1-0.8-0.6 z -0.4-0.2 0 λ The tangent function takes on infinite values when βl approaches π/2 modulo 2π 29 / 38

Shorted Line Impedance (III) Shorted transmission line can have infinite input impedance! This is particularly surprising since the load is in effect transformed from a short of Z L = 0 to an infinite impedance. A plot of the voltage/current as a function of z is shown below v/v + 2 v( λ/4) 1. 5 v(z) i(z) Z 0 1 i( λ/4) 0. 5 0-1 -0.8-0.6-0.4-0.2 0 z/λ 30 / 38

Shorted Line Reactance l λ/4 inductor l < λ/4 inductive reactance l = λ/4 open (acts like resonant parallel LC circuit) l > λ/4 but l < λ/2 capacitive reactance And the process repeats... jx(z) 10 7. 5 2. 5 0-2.5-5 -7.5 5.25.5.75 1.0 1.25 z λ 31 / 38

Open Line I/V The open transmission line has infinite VSWR and ρ L = 1. At any given point along the transmission line v(z) = V + (e jβz + e jβz ) = 2V + cos(βz) whereas the current is given by or i(z) = V + Z 0 (e jβz e jβz ) i(z) = 2jV + Z 0 sin(βz) 32 / 38

Open Line Impedance (I) The impedance at any point along the line takes on a simple form Z in ( l) = v( l) i( l) = jz 0 cot(βl) This is a special case of the more general transmision line equation with Z L =. Note that the impedance is purely imaginary since an open lossless transmission line cannot dissipate any power. We have learned, though, that the line stores reactive energy in a distributed fashion. 33 / 38

Open Line Impedance (II) A plot of the input impedance as a function of z is shown below Z in (λ/2) 10 8 Z in (z) Z 0 6 4 2 Z in (λ/4) -1-0.8-0.6 z -0.4-0.2 0 λ The cotangent function takes on zero values when βl approaches π/2 modulo 2π 34 / 38

Open Line Impedance (III) Open transmission line can have zero input impedance! This is particularly surprising since the open load is in effect transformed from an open A plot of the voltage/current as a function of z is shown below v/v + 2 i( λ/4) 1. 5 v(z) i(z)z 0 1 v( λ/4) 0. 5 0-1 -0.8-0.6-0.4-0.2 0 z/λ 35 / 38

Open Line Reactance l λ/4 capacitor l < λ/4 capacitive reactance l = λ/4 short (acts like resonant series LC circuit) l > λ/4 but l < λ/2 inductive reactance And the process repeats... 10 7. 5 5 2. 5 jx(z) 0-2.5-5 -7.5.25.5.75 1.0 1.25 z λ 36 / 38

λ/2 Transmission Line Plug into the general T-line equaiton for any multiple of λ/2 Z in ( mλ/2) = Z 0 Z L + jz 0 tan( βλ/2) Z 0 + jz L tan( βλ/2) βλm/2 = 2π λm λ 2 = πm tan mπ = 0 if m Z Z Z in ( λm/2) = Z L 0 Z 0 = Z L Impedance does not change... it s periodic about λ/2 (not λ) 37 / 38

λ/4 Transmission Line Plug into the general T-line equaiton for any multiple of λ/4 λm βλm/4 = 2π λ 4 = π 2 m tan m π 2 = if m is an odd integer Z in ( λm/4) = Z 2 0 Z L λ/4 line transforms or inverts the impedance of the load 38 / 38